979 resultados para Respiratory Tract


Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE To compare the effectiveness of two speech therapy interventions, vocal warm-up and breathing training, focusing on teachers’ voice quality.METHODS A single-blind, randomized, parallel clinical trial was conducted. The research included 31 20 to 60-year old teachers from a public school in Salvador, BA, Northeasatern Brazil, with minimum workloads of 20 hours a week, who have or have not reported having vocal alterations. The exclusion criteria were the following: being a smoker, excessive alcohol consumption, receiving additional speech therapy assistance while taking part in the study, being affected by upper respiratory tract infections, professional use of the voice in another activity, neurological disorders, and history of cardiopulmonary pathologies. The subjects were distributed through simple randomization in groups vocal warm-up (n = 14) and breathing training (n = 17). The teachers’ voice quality was subjectively evaluated through the Voice Handicap Index (Índice de Desvantagem Vocal, in the Brazilian version) and computerized voice analysis (average fundamental frequency, jitter, shimmer, noise, and glottal-to-noise excitation ratio) by speech therapists.RESULTS Before the interventions, the groups were similar regarding sociodemographic characteristics, teaching activities, and vocal quality. The variations before and after the intervention in self-assessment and acoustic voice indicators have not significantly differed between the groups. In the comparison between groups before and after the six-week interventions, significant reductions in the Voice Handicap Index of subjects in both groups were observed, as wells as reduced average fundamental frequencies in the vocal warm-up group and increased shimmer in the breathing training group. Subjects from the vocal warm-up group reported speaking more easily and having their voices more improved in a general way as compared to the breathing training group.CONCLUSIONS Both interventions were similar regarding their effects on the teachers’ voice quality. However, each contribution has individually contributed to improve the teachers’ voice quality, especially the vocal warm-up.TRIAL RECORD NCT02102399, “Vocal Warm-up and Respiratory Muscle Training in Teachers”.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

ABSTRACT OBJECTIVE To analyze the impact of air pollution on respiratory and cardiovascular morbidity of children and adults in the city of Vitoria, state of Espirito Santo. METHODS A study was carried out using time-series models via Poisson regression from hospitalization and pollutant data in Vitoria, ES, Southeastern Brazil, from 2001 to 2006. Fine particulate matter (PM10), sulfur dioxide (SO2), and ozone (O3) were tested as independent variables in simple and cumulative lags of up to five days. Temperature, humidity and variables indicating weekdays and city holidays were added as control variables in the models. RESULTS For each increment of 10 µg/m3 of the pollutants PM10, SO2, and O3, the percentage of relative risk (%RR) for hospitalizations due to total respiratory diseases increased 9.67 (95%CI 11.84-7.54), 6.98 (95%CI 9.98-4.17) and 1.93 (95%CI 2.95-0.93), respectively. We found %RR = 6.60 (95%CI 9.53-3.75), %RR = 5.19 (95%CI 9.01-1.5), and %RR = 3.68 (95%CI 5.07-2.31) for respiratory diseases in children under the age of five years for PM10, SO2, and O3, respectively. Cardiovascular diseases showed a significant relationship with O3, with %RR = 2.11 (95%CI 3.18-1.06). CONCLUSIONS Respiratory diseases presented a stronger and more consistent relationship with the pollutants researched in Vitoria. A better dose-response relationship was observed when using cumulative lags in polynomial distributed lag models.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction: Lower Respiratory Tract Infections (LRTIs) are highly prevalent in institutionalised people with dementia, constituting an important cause of morbidity and mortality. Computerised auscultation of Adventitious Lung Sounds (ALS) has shown to be objective and reliable to assess and monitor respiratory diseases, however its application in people with dementia is unknown. Aim: This study characterised ALS (crackles and wheezes) in institutionalised people with dementia. Methods: An exploratory descriptive study, including 6 long-term care institutions was conducted. The sample included a dementia group (DG) of 30 people with dementia and a match healthy group (HG) of 30 elderly people. Socio-demographic and anthropometric data, cognition, type and severity of dementia, cardio-respiratory parameters, balance, mobility and activities and participation were collected. Lung sounds were recorded with a digital stethoscope following Computerised Respiratory Sound Analysis (CORSA) guidelines. Crackles’ location, number (N), frequency (F), two-cycle duration (2CD), initial deflection width (IDW) and largest deflection width (LDW) and wheezes’ number (N), ratio (R) and frequency (F) were analysed per breathing phase. Statistical analyses were performed using PASW Statistics(v.19). Results: There were no significant differences between the two groups in relation to the mean N of crackles during inspiration and expiration in both trachea and thorax. DG trachea crackles had significant higher F during inspiration and lower IDW, 2CD and LDW during expiration when compared with HG. At the thorax, the LDW during inspiration was also significantly lower in the DG. A significant higher N of inspiratory wheezes was found in the HG. Both groups had a low ratio of high frequency wheezes. Conclusion: Computerised analyses of ALS informed on the respiratory system and function of people with dementia and elderly people. Hence, this could be the step towards prevention, early diagnosis and continuous monitoring of respiratory diseases in people with cognitive impairment.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

RESUMO Nos últimos anos têm sido identificados vários factores de risco para asma brônquica em crianças com sibilância recorrente, não se encontrando clara a importância da avaliação funcional respiratória nestas crianças. De igual modo, têm sido documentados resultados contraditórios na avaliação imunológica das populações de células reguladoras bem como na expressão de polimorfismos para a asma. O objectivo deste estudo consistiu na avaliação e comparação de parâmetros de avaliação funcional respiratória, imunológica e de polimorfismos genéticos em crianças entre 8 e 20 meses de idade, com três ou mais episódios de sibilância (n=50), sem qualquer terapêutica anti-inflamatória prévia, diagnosticados por um médico, com e sem factores de risco para asma brônquica (história de asma parental ou história pessoal de eczema ou pelo menos dois dos seguintes: história pessoal de rinite alérgica, sibilância fora do contexto infeccioso e contagem de eosinófilos no sangue periférico > 4%), comparados com um grupo controlo (n=30). Nestas crianças foram efectuadas provas de função respiratória em volume corrente e em volume aumentado através de técnicas de compressão torácica, avaliação de populações celulares por citometria de fluxo, expressão de citocinas por mARN em culturas de células estimuladas com PMA (leitura às 24 horas) e com extractos de ácaros do pó doméstico (leitura ao 7º dia) e expressão de polimorfismos para alguns genes associados a asma (ADAM 33, DPP10, GPRA). Na comparação entre as crianças com sibilância recorrente em relação ao grupo controlo foram observadas reduções significativas nos Z-scores para FVC (diferença média [95% IC]: -0,7 [-1,2; -0,1], p=0,01), FEV0.5 (-1,0 [-1,5; -0,5], p=0,0001), FEF75 (-0,6 [-1,0; -0,2], p=0,0001) e FEF25-75 (-0,8 [-1,2; -0,4], p=0,0001), bem como valores significativamente mais baixos para a quantificação do número absoluto de CD4+CD25forte (-47,9 [-89,6; -6,1], p=0,03), do número absoluto e percentual de CD4+CD25+CTLA-4 (p=0,0001) e da expressão de CTLA-4 (p=0,03) e IFN-

Relevância:

60.00% 60.00%

Publicador:

Resumo:

RESUMO - A exposição a formaldeído é reconhecidamente um dos mais importantes factores de risco presente nos laboratórios hospitalares de anatomia patológica. Neste contexto ocupacional, o formaldeído é utilizado em solução, designada comummente por formol. Trata-se de uma solução comercial de formaldeído, normalmente diluída a 10%, sendo pouco onerosa e, por esse motivo, a eleita para os trabalhos de rotina em anatomia patológica. A solução é utilizada como fixador e conservante do material biológico, pelo que as peças anatómicas a serem processadas são previamente impregnadas. No que concerne aos efeitos para a saúde do formaldeído, os efeitos locais parecem apresentar um papel mais importante comparativamente com os efeitos sistémicos, devido à sua reactividade e rápido metabolismo nas células da pele, tracto gastrointestinal e pulmões. Da mesma forma, a localização das lesões correspondem principalmente às zonas expostas às doses mais elevadas deste agente químico, ou seja, o desenvolvimento dos efeitos tóxicos dependerá mais da intensidade da dose externa do que da duração da exposição. O efeito do formaldeído no organismo humano mais facilmente detectável é a acção irritante, transitória e reversível sobre as mucosas dos olhos e aparelho respiratório superior (naso e orofaringe), o que acontece em geral para exposições frequentes e superiores a 1 ppm. Doses elevadas são citotóxicas e podem conduzir a degenerescência e necrose das mucosas e epitélios. No que concerne aos efeitos cancerígenos, a primeira avaliação efectuada pela International Agency for Research on Cancer data de 1981, actualizada em 1982, 1987, 1995 e 2004, considerando-o como um agente cancerígeno do grupo 2A (provavelmente carcinogénico). No entanto, a mais recente avaliação, em 2006, considera o formaldeído no Grupo 1 (agente carcinogénico) com base na evidência de que a exposição a este agente é susceptível de causar cancro nasofaríngeo em humanos. Constituiu objectivo principal deste estudo caracterizar a exposição profissional a formaldeído nos laboratórios hospitalares de anatomia patológica Portugueses. Pretendeu-se, ainda, descrever os fenómenos ambientais da contaminação ambiental por formaldeído e explorar eventuais associações entre variáveis. Considerou-se uma amostra de 10 laboratórios hospitalares de anatomia patológica, avaliada a exposição dos três grupos profissionais por comparação com os dois referenciais de exposição e, ainda, conhecidos os valores de concentração máxima em 83 actividades. Foram aplicados simultaneamente dois métodos distintos de avaliação ambiental: um dos métodos (Método 1) fez uso de um equipamento de leitura directa com o princípio de medição por Photo Ionization Detection, com uma lâmpada de 11,7 eV e, simultaneamente, realizou-se o registo da actividade. Este método disponibilizou dados para o referencial de exposição da concentração máxima; o outro método (Método 2) traduziu-se na aplicação do método NIOSH 2541, implicando o uso de bombas de amostragem eléctricas de baixo caudal e posterior processamento analítico das amostras por cromatografia gasosa. Este método, por sua vez, facultou dados para o referencial de exposição da concentração média ponderada. As estratégias de medição de cada um dos métodos e a definição dos grupos de exposição existentes neste contexto ocupacional, designadamente os Técnicos de Anatomia Patológica, os Médicos Anatomo-Patologistas e os Auxiliares, foram possíveis através da informação disponibilizada pelas técnicas de observação da actividade da análise (ergonómica) do trabalho. Estudaram-se diversas variáveis independentes, nomeadamente a temperatura ambiente e a humidade relativa, a solução de formaldeído utilizada, as condições de ventilação existentes e o número médio de peças processadas por dia em cada laboratório. Para a recolha de informação sobre estas variáveis foi preenchida, durante a permanência nos laboratórios estudados, uma Grelha de Observação e Registo. Como variáveis dependentes seleccionaram-se três indicadores de contaminação ambiental, designadamente o valor médio das concentrações superiores a 0,3 ppm em cada laboratório, a Concentração Média Ponderada obtida para cada grupo de exposição e o Índice do Tempo de Regeneração de cada laboratório. Os indicadores foram calculados e definidos através dos dados obtidos pelos dois métodos de avaliação ambiental aplicados. Baseada no delineado pela Universidade de Queensland, foi ainda aplicada uma metodologia de avaliação do risco de cancro nasofaríngeo nas 83 actividades estudadas de modo a definir níveis semi-quantitativos de estimação do risco. Para o nível de Gravidade considerou-se a informação disponível em literatura científica que define eventos biológicos adversos, relacionados com o modo de acção do agente químico e os associa com concentrações ambientais de formaldeído. Para o nível da Probabilidade utilizou-se a informação disponibilizada pela análise (ergonómica) de trabalho que permitiu conhecer a frequência de realização de cada uma das actividades estudadas. A aplicação simultânea dos dois métodos de avaliação ambiental resultou na obtenção de resultados distintos, mas não contraditórios, no que concerne à avaliação da exposição profissional a formaldeído. Para as actividades estudadas (n=83) verificou-se que cerca de 93% dos valores são superiores ao valor limite de exposição definido para a concentração máxima (VLE-CM=0,3 ppm). O “exame macroscópico” foi a actividade mais estudada e onde se verificou a maior prevalência de resultados superiores ao valor limite (92,8%). O valor médio mais elevado da concentração máxima (2,04 ppm) verificou-se no grupo de exposição dos Técnicos de Anatomia Patológica. No entanto, a maior amplitude de resultados observou-se no grupo dos Médicos Anatomo-Patologistas (0,21 ppm a 5,02 ppm). No que respeita ao referencial da Concentração Média Ponderada, todos os valores obtidos nos 10 laboratórios estudados para os três grupos de exposição foram inferiores ao valor limite de exposição definido pela Occupational Safety and Health Administration (TLV-TWA=0,75 ppm). Verificou-se associação estatisticamente significativa entre o número médio de peças processadas por laboratório e dois dos três indicadores de contaminação ambiental utilizados, designadamente o valor médio das concentrações superiores a 0,3 ppm (p=0,009) e o Índice do Tempo de Regeneração (p=0,001). Relativamente à temperatura ambiente não se observou associação estatisticamente significativa com nenhum dos indicadores de contaminação ambiental utilizados. A humidade relativa apresentou uma associação estatisticamente significativa apenas com o indicador de contaminação ambiental da Concentração Média Ponderada de dois grupos de exposição, nomeadamente com os Médicos Anatomo-Patologistas (p=0,02) e os Técnicos de Anatomia Patológica (p=0,04). A aplicação da metodologia de avaliação do risco nas 83 actividades estudadas permitiu verificar que, em cerca de dois terços (35%), o risco foi classificado como (pelo menos) elevado e, ainda, constatar que 70% dos laboratórios apresentou pelo menos 1 actividade com a classificação de risco elevado. Da aplicação dos dois métodos de avaliação ambiental e das informações obtidas para os dois referenciais de exposição pode concluir-se que o referencial mais adequado é a Concentração Máxima por estar associado ao modo de actuação do agente químico. Acresce, ainda, que um método de avaliação ambiental, como o Método 1, que permite o estudo das concentrações de formaldeído e simultaneamente a realização do registo da actividade, disponibiliza informações pertinentes para a intervenção preventiva da exposição por permitir identificar as actividades com a exposição mais elevada, bem como as variáveis que a condicionam. As peças anatómicas apresentaram-se como a principal fonte de contaminação ambiental por formaldeído neste contexto ocupacional. Aspecto de particular interesse, na medida que a actividade desenvolvida neste contexto ocupacional e, em particular na sala de entradas, é centrada no processamento das peças anatómicas. Dado não se perspectivar a curto prazo a eliminação do formaldeído, devido ao grande número de actividades que envolvem ainda a utilização da sua solução comercial (formol), pode concluir-se que a exposição a este agente neste contexto ocupacional específico é preocupante, carecendo de uma intervenção rápida com o objectivo de minimizar a exposição e prevenir os potenciais efeitos para a saúde dos trabalhadores expostos. ---------------- ABSTRACT - Exposure to formaldehyde is recognized as one of the most important risk factors present in anatomy and pathology laboratories from hospital settings. In this occupational setting, formaldehyde is used in solution, typically diluted to 10%, and is an inexpensive product. Because of that, is used in routine work in anatomy and pathology laboratories. The solution is applied as a fixative and preservative of biological material. Regarding formaldehyde health effects, local effects appear to have a more important role compared with systemic effects, due to his reactivity and rapid metabolism in skin, gastrointestinal tract and lungs cells. Likewise, lesions location correspond mainly to areas exposed to higher doses and toxic effects development depend more on external dose intensity than exposure duration. Human body formaldehyde effect more easily detectable is the irritating action, transient and reversible on eyes and upper respiratory tract (nasal and throat) membranes, which happen in general for frequent exposure to concentrations higher than 1 ppm. High doses are cytotoxic and can lead to degeneration, and also to mucous membranes and epithelia necrosis. With regard to carcinogenic effects, first assessment performed by International Agency for Research on Cancer in 1981, updated in 1982, 1987, 1995 and 2004, classified formaldehyde in Group 2A (probably carcinogenic). However, most recent evaluation in 2006, classifies formaldehyde carcinogenic (Group 1), based on evidence that exposure to this agent is likely to cause nasopharyngeal cancer in humans. This study principal objective was to characterize occupational exposure to formaldehyde in anatomy and pathology hospital laboratories, as well to describe formaldehyde environmental contamination phenomena and explore possible associations between variables. It was considered a sample of 10 hospital pathology laboratories, assessed exposure of three professional groups for comparison with two exposure metrics, and also knows ceiling concentrations in 83 activities. Were applied, simultaneously, two different environmental assessment methods: one method (Method 1) using direct reading equipment that perform measure by Photo Ionization Detection, with 11,7 eV lamps and, simultaneously, make activity description and film. This method provided data for ceiling concentrations for each activity study (TLV-C). In the other applied method (Method 2), air sampling and formaldehyde analysis were performed according to NIOSH method (2541). This method provided data average exposure concentration (TLV-TWA). Measuring and sampling strategies of each methods and exposure groups definition (Technicians, Pathologists and Assistants) was possible by information provided by activities (ergonomic) analysis. Several independent variables were studied, including temperature and relative humidity, formaldehyde solution used, ventilation conditions, and also anatomic pieces mean value processed per day in each laboratory. To register information about these variables was completed an Observation and Registration Grid. Three environmental contamination indicators were selected has dependent variables namely: mean value from concentrations exceeding 0,3 ppm in each laboratory, weighted average concentration obtained for each exposure group, as well each laboratory Time Regeneration Index. These indicators were calculated and determined through data obtained by the two environmental assessment methods. Based on Queensland University proposal, was also applied a methodology for assessing nasopharyngeal cancer risk in 83 activities studied in order to obtain risk levels (semi-quantitative estimation). For Severity level was considered available information in scientific literature that defines biological adverse events related to the chemical agent action mode, and associated with environment formaldehyde concentrations. For Probability level was used information provided by (ergonomic) work analysis that helped identifies activity frequency. Environmental assessment methods provide different results, but not contradictory, regarding formaldehyde occupational exposure evaluation. In the studied activities (n=83), about 93% of the values were above exposure limit value set for ceiling concentration in Portugal (VLE-CM = 0,3 ppm). "Macroscopic exam" was the most studied activity, and obtained the higher prevalence of results superior than 0,3 ppm (92,8%). The highest ceiling concentration mean value (2,04 ppm) was obtain in Technicians exposure group, but a result wider range was observed in Pathologists group (0,21 ppm to 5,02 ppm). Concerning Method 2, results from the three exposure groups, were all lower than limit value set by Occupational Safety and Health Administration (TLV-TWA=0,75ppm). There was a statistically significant association between anatomic pieces mean value processed by each laboratory per day, and two of the three environmental contamination indicators used, namely average concentrations exceeding 0,3 ppm (p=0,009) and Time Regeneration Index (p=0,001). Temperature was not statistically associated with any environmental contamination used indicators. Relative humidity had a statistically significant association only with one environmental contamination indicator, namely weighted average concentration, particularly with Pathologists group (p=0,02) and Technicians group (p=0,04). Risk assessment performed in the 83 studied activities showed that around two thirds (35%) were classified as (at least) high, and also noted that 70% of laboratories had at least 1 activity with high risk rating. The two environmental assessment methods application, as well information obtained from two exposure metrics, allowed to conclude that most appropriate exposure metric is ceiling concentration, because is associated with formaldehyde action mode. Moreover, an environmental method, like Method 1, which allows study formaldehyde concentrations and relates them with activity, provides relevant information for preventive information, since identifies the activity with higher exposure, as well variables that promote exposure. Anatomic pieces represent formaldehyde contamination main source in this occupational setting, and this is of particular interest because all activities are focused on anatomic pieces processing. Since there is no prospect, in short term, for formaldehyde use elimination due to large number of activities that still involve solution use, it can be concluded that exposure to this agent, in this particular occupational setting, is preoccupant, requiring an rapid intervention in order to minimize exposure and prevent potential health effects in exposed workers.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Nosocomial infection among male patients in a public psychiatric hospital was studied and the definitions for use in long-term care facilities were employed for diagnosis. The overall nosocomial infection rate was 6.7 per 1,000 day inpatients; 55.6% of these infections were identified in the respiratory tract, 50% of them being respiratory viral diseases; 38.9% of the nosocomial infections involved the eyes, ears, nose, throat and mouth, and 5.6% involved the skin and soft tissues. The epidemiological characteristics and the main clinical alterations of these inpatients were also identified.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Trypsin is required in the hemagglutinin (HA) cleavage to in vitro influenza viruses activation. This HA cleavage is necessary for virus cell entry by receptor-mediated endocytosis. Bacteria in the respiratory tract are potential sources of proteases that could contribute to the cleavage of influenza virus in vivo. From 47 samples collected from horses, pigs, and from humans, influenza presence was confirmed in 13 and these samples demonstrated co-infection of influenza with flagellated bacteria, Stenotrophomonas maltophilia from the beginning of the experiments. Despite treatment with antibiotics, the bacteria remained resistant in several of the co-infected samples (48.39%). These bacteria, considered opportunistic invaders from environmental sources, are associated with viral infections in upper respiratory tract of hosts. The protease (elastase), secreted by Stenotrophomonas maltophilia plays a role in the potentiation of influenza virus infection. Proteolytic activity was detected by casein agar test. Positive samples from animals and humans had either a potentiated influenza infectivity or cytopathic effect (CPE) in MDCK and NCI H292 cells, Stenotrophomonas maltophilia were always present. Virus and bacteria were observed ultrastructurally. These in vitro findings show that microbial proteases could contribute to respiratory complications by host protease activity increasing inflammation or destroying endogenous cell protease inhibitors.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction: Rhinoscleroma is a rare, chronic, granulomatous disease that most frequently affects the upper respiratory tract, especially the nasal cavity and sometimes extends through the lower respiratory tract. Is associated with Klebsiella rhinoscleromatis, which is endemic in certain geographic regions namely Central America. The pathogenesis and risk factors remain unclear. Clinical case: We report a five years Old Portuguese boy, previously healthy, brought to the Emergency Department with epistaxis, without other accompanying signs or symptoms. The Otorhinolaryngologist (ORL) performed rhinoscopy and identified an intranasal bleeding mass. The MRI revealed an intranasal mass with extension to the ethmoid bone sinus, and performed biopsy. The histopathology was vital, making the diagnosis of Rhinoscleroma. The child had traveled abroad for the first time on vacations a year before to Dominican Republic. The bacteriologic exam identified a Klebsiella spp. sensible to the association of amoxicillin and clavulanic acid. Blood test performed excluded association of immunodeficiency. Since it’s a rare disease genetic study are under course. Monthly evaluation by ORL and pediatrician was performed which documented progressive reduction until total disappearing of the macro and microscopic lesion, and negative bacteriologic exam. Six months of antibiotic therapy were completed without any known secondary effects. The child remained asymptomatic up to the last visit, 3 months following treatment and has shown no evidence of recurrence. Conclusion: Globalization and free transit of people to areas far from origin countries here some rare diseases are endemic brings a new challenge to modern medicine. Sometimes vacations bring more than memories.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A thesis submitted in fulfilment of the requirements for the degree of Masters in Molecular Genetics and Biomedicine

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The enzyme-linked immunosorbent assay (ELISA) is the most widely used tool to detect anti-Toxocara IgG antibodies for both serodiagnostic and seroepidemiological surveys on human toxocariasis. In the last eight years a high prevalence of toxocariasis (32.2-56.0%) has been reported in children attending public health units from municipalities in the state of Paraná, Brazil. Therefore, the aim of this work was to compare the frequency found among the general child population with that of children attending a public pneumology service in Maringá, Paraná, Brazil and describe the laboratorial, clinical and epidemiological findings. The research was conducted at the Consórcio Público Intermunicipal de Saúde do Setentrião Paranaense (CISAMUSEP) from July 2009 to July 2010 among children aged between one and 15 years. From a total of 167 children studied, only 4.2% (7/167) tested positive for anti-Toxocara spp. IgG antibodies and presented mild eosinophilia (2/7), increased serum IgE levels (6/7) and a positive allergy test for mites (5/7). The presence of pets (dogs or cats) at home did not correlate with the seroprevalence. In conclusion, cases of toxocariasis involving the respiratory tract are rare in children attending a public health pneumology unit in the northwestern region of Paraná State, despite the high prevalence of this type of toxocariasis among the infantile population attending Basic Health Units in the same geographical area.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introdução: Os serviços de urgência pediátrica são ambientes particularmente deletérios para os recém-nascidos. A identifica - ção precoce da doença neste grupo é fundamental, uma vez que o atraso diagnóstico pode estar associado a consequências graves. A maioria dos sistemas de triagem utilizados nos serviços de urgência pediátrica não possui algoritmos específicos para os recém-nascidos. Este estudo teve como objetivos caracterizar os recém-nascidos que recorreram ao serviço de urgência pediátrica, analisar a sua categorização pelo Sistema de Triagem de Manchester e identificar fatores de risco associados ao internamento. Métodos: Estudo retrospetivo efetuado pela análise dos dados de recém-nascidos admitidos no serviço de urgência pediátrica no ano de 2012. Resultados: Foram incluídos 779 recém-nascidos com idade média de 16,78 dias. Os principais diagnósticos de admissão foram as infeções respiratórias (21,9%) e a cólica do lactente (21%). Ficaram internados 22,2%, sendo os principais motivos as infe - ções respiratórias baixas (19,7%), os episódios de apparent life threatening event (15%) e as gastroenterites agudas (10,8%). A presença de hipoxemia e a realização de exames complementares no serviço de urgência pediátrica associaram-se a maior taxa de internamento (p = 0,001), assim como a atribuição de nível de prioridade “urgente”, “muito urgente” ou “emergente” pelo Sistema de Triagem de Manchester (p = 0,001). Discussão: O recurso dos recém-nascidos ao serviço de urgência pediátrica neste hospital ocorre maioritariamente por situa- ções de doença aguda. Os diagnósticos de admissão mais frequentes apresentam pouca gravidade clínica, já que contribuem pouco para o número de internamentos. Verifica-se uma correlação entre o nível de prioridade atribuído pelo Sistema de Triagem de Manchester e a necessidade de internamento neste grupo etário.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

RESUMO Tratando-se a asma de uma doença respiratória, desde há várias décadas que tem sido abordada a hipótese de que factores ambientais, nomeadamente os relacionados com a qualidade do ar inalado, possam contribuir para o seu agravamento. Para além dos aeroalergenos, outros factores ambientais como a poluição atmosférica estarão associados às doenças respiratórias. O ar respirado contém uma variedade de poluentes atmosféricos, provenientes quer de fontes naturais quer de origem antropogénica, nomeadamente de actividades industriais, domésticas ou das emissões de veículos. Estes poluentes, tradicionalmente considerados como um problema de foro ambiental, têm sido cada vez mais encarados como um problema de saúde pública. Também a qualidade do ar interior, tem sido associada a queixas respiratórias, não só em termos ocupacionais mas também em exposições domésticas. Dentro dos principais poluentes, encontramos a matéria particulada (como as PM10), o O3, NO2, e os compostos orgânicos voláteis (COVs). Se é verdade que os três primeiros têm como principais fontes de exposição a combustão fóssil associada aos veículos automóveis, já os COVs (como o benzeno, tolueno, xileno, etilbenzeno e formaldeído) são poluentes mais característicos do ar interior. Os mecanismos fisiopatológicos subjacentes à agressão dos poluentes do ar não se encontram convenientemente esclarecidos. Pensa-se que após a sua inalação, induzam um grau crescente de stress oxidativo que será responsável pelo desenvolvimento da inflamação das vias aéreas. A progressão do stress oxidativo e da inflamação, associarse- ão posteriormente a lesão local (pulmonar) e sistémica. Neste trabalho pretendeu-se avaliar os efeitos da exposição individual a diversos poluentes, do ar exterior e interior, sobre as vias aéreas, recorrendo a parâmetros funcionais, inflamatórios e do estudo do stress oxidativo. Neste sentido, desenvolveu-se um estudo de painel na cidade de Viseu, em que foram acompanhadas durante 18 meses, 51 crianças com história de sibilância, identificadas pelo questionário do estudo ISAAC. As crianças foram avaliadas em quatro Visitas (quatro medidas repetidas), através de diversos exames, que incluíram execução de espirometria com broncodilatação, medição ambulatória do PEF, medição de FENO e estudo do pH no condensado brônquico do ar exalado. O estudo dos 8-isoprostanos no condensado brônquico foi efectuado somente em duas Visitas, e o do doseamento de malonaldeído urinário somente na última Visita. Para além da avaliação do grau de infestação de ácaros do pó do colchão, para cada criança foi calculado o valor de exposição individual a PM10, O3, NO2, benzeno, tolueno, xileno, etilbenzeno e formaldeído, através de uma complexa metodologia que envolveu técnicas de modelação associadas a medições directas do ar interior (na casa e escola da criança) e do ar exterior. Para a análise de dados foram utilizadas equações de estimação generalizadas com uma matriz de correlação de trabalho uniforme, com excepção do estudo das associações entre poluentes, 8-isoprostanos e malonaldeído. Verificou-se na análise multivariável a existência de uma associação entre o agravamento dos parâmetros espirométricos e a exposição aumentada a PM10, NO2, benzeno, tolueno e etilbenzeno. Foram também encontradas associações entre diminuição do pH do EBC e exposição crescente a PM10, NO2, benzeno e etilbenzeno e associações entre valores aumentados de FENO e exposição a etilbenzeno e tolueno. O benzeno, o tolueno e o etilbenzeno foram associados com maior recurso a broncodilatador nos 6 meses anteriores à Visita e o tolueno com deslocações ao serviço de urgência. Os resultados dos modelos de regressão que incluíram o efeito do poluente ajustado para o grau de infestação de ácaros do pó foram, de uma forma geral, idênticos ao da análise multivariável anterior, com excepção das associações para com o FENO. Nos modelos de exposição com dois poluentes, com o FEV1 como variável resposta, somente o benzeno persistiu com significado estatístico. No modelo com dois poluentes tendo o pH do EBC como variável resposta, somente persistiram as PM10. Os 8-isoprostanos correlacionaram-se com alguns COVs, designadamente etilbenzeno, xileno, tolueno e benzeno. Os valores de malonaldeído urinário não se correlacionaram com os valores de poluentes. Verificou-se no entanto que de uma forma geral, e em particular mais uma vez para os COVs, as crianças mais expostas a poluentes, apresentaram valores superiores de malonaldeído na urina. Verificou-se que os poluentes do ar em geral, e os COVs em particular, se associaram com uma deterioração das vias aéreas. A exposição crescente a poluentes associou-se não só com obstrução brônquica, mas também com FENO aumentado e maior acidez das vias aéreas. A exposição crescente a COVs correlacionou-se com um maior stress oxidativo das vias aéreas (medido pelos 8-isoprostanos). As crianças com exposição superior a COVs apresentaram maiores valores de malonaldeído urinário. Este trabalho sugere uma associação entre exposição a poluentes, inflamação das vias aéreas e stress oxidativo. Vem reforçar o interesse dos poluentes do ar, nomeadamente os associados a ambientes interiores, frequentemente esquecidos e que poderão ser explicativos do agravamento duma criança com sibilância.-----------ABSTRACT: Asthma is a chronic respiratory disease that could be influenced by environmental factors, as allergens and air pollutants. The air breathed contains a diversity of air pollutants, both from natural or anthropogenic sources. Atmospheric pollution, traditionally considered an environmental problem, is nowadays looked as an important public health problem. Indoor air pollutants are also related with respiratory diseases, not only in terms of occupational exposures but also in domestic activities. Particulate matter (such as PM10), O3, NO2 and volatile organic compounds (VOCs) are the main air pollutants. The main source for PM10, O3, NO2 exposure is traffic exhaust while for VOCs (such as benzene, toluene, xylene, ethylbenzene and phormaldehyde) the main sources for exposure are located in indoor environments. The pathophysiologic mechanisms underlying the aggression of air pollutants are not properly understood. It is thought that after inhalation, air pollutants could induce oxidative stress, which would be responsible for airways inflammation. The progression of oxidative stress and airways inflammation, would contribute for the local and systemic effects of the air pollutants. The present study aimed to evaluate the effects of individual exposure to various pollutants over the airways, through lung function tests, inflammatory and oxidative stress biomarkers. In this sense, we developed a panel study in the city of Viseu, that included 51 children with a history of wheezing. Those children that were identified by the ISAAC questionnaire, were followed for 18 months. Children were assessed four times (four repeated measures) through the following tests: spirometry with bronchodilation test, PEF study, FENO evaluation and exhaled breath condensate pH measurement. 8-isoprostane in the exhaled breath condensate were also measured but only in two visits. Urinary malonaldehyde measurement was performed only in the last visit. Besides the assessment of the house dust mite infestation, we calculated for each child the value of individual exposure to a wide range of pollutants: PM10, O3, NO2, benzene, toluene, xylene, ethyl benzene and formaldehyde. This strategy used a complex methodology that included air pollution modelling techniques and direct measurements indoors (homes and schools) and outdoors. Generalized estimating equations with an exchangeable working correlation matrix were used for the analysis of the data. Exceptions were for the study of associations between air pollutants, malonaldehyde and 8-isoprostanes. In the multivariate analysis we found an association between worsening of spirometric outcomes and increased exposure to PM10, NO2, benzene, toluene and ethylbenzene. In the multivariate analysis we found also negative associations between EBC pH and exposure to PM10, NO2, benzene, ethylbenzene and positive associations between FENO and exposure to ethylbenzene and toluene. Benzene, toluene and ethylbenzene were associated with increased use of bronchodilator in the 6 months prior to the visit and toluene with emergency department visits. Results of the regression models that included also the effect of the pollutant adjusted for the degree of infestation to house dust mites, were identical to the previous models. Exceptions were for FENO associations. In the two-pollutant models, with the FEV1 as dependent variable, only benzene persisted with statistical significance. In the two pollutant model with pH of EBC as dependent variable, only PM10 persisted. 8-isoprostanes were well correlated with some VOCs, namely with ethylbenzene, xylene, toluene and benzene. Urinary malonaldehyde did not present any correlation with air pollutants exposure. However, those children more exposed to air pollutants (namely to VOCs), presented higher values of malonaldehyde. It was found that air pollutants in general, and namely VOCs, were associated with deterioration of the airways. The increased exposure to air pollutants was associated not only with airways obstruction, but also with increased FENO and higher acidity of the airways. The increased exposure to VOCs was correlated with increased airways oxidative stress (measured by 8-isoprostane). Children with higher levels of exposure to VOCs had higher values of urinary malonaldehyde. This study suggests a relation between air pollution, airways inflammation and oxidative stress. It suggests also that attention should be dedicated to air quality as air pollutants could cause airways deterioration.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Influenza surveillance is usually based on nationally organized sentinel networks of physicians and on hospital reports. This study aimed to test a different report system, based on parents' phone contact to the research team and in home collection of samples by a dedicated team. The identification of influenza and other respiratory viruses in children who attended a Hospital Emergency Department was also recorded. Real-time PCR and reverse transcription PCR were performed for influenza A and B, parainfluenza 1-4, adenovirus, human metapneumovirus, respiratory syncytial virus A and B, rhinovirus, enterovirus, group 1 coronaviruses, group 2 coronaviruses, and human bocavirus. One hundred children were included, 64 from the day care centers and 36 from the Hospital. Overall, 79 samples were positive for at least one respiratory virus. Influenza A (H3) was the virus most frequently detected: 25 cases, 20 of these in children under 5 years of age (ten from day care centers and ten who went to the hospital) which was higher than those reported by the National Influenza Surveillance Programme for this age. CONCLUSION: The results obtained in this study suggest that a surveillance system based on parents' reports could complement the implanted system of the National Influenza Surveillance Programme.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

RESUMO: Os vírus respiratórios continuam a ocupar um papel relevante na morbilidade e mortalidade infantil, tendo na última década sido alargado o espectro de vírus potencialmente causadores das infeções respiratórias. O diagnóstico destas infeções pode ser efetuado por várias metodologias, sendo as técnicas de biologia molecular consideradas as mais sensíveis para este fim. No âmbito do Projeto Ambiente e Saúde em Creches e Infantários (ENVIRH) foi efetuada uma comparação da prevalência dos principais vírus respiratórios em crianças em idade pré-escolar, com critérios de infeção respiratória, recorrendo a técnicas de biologia molecular, em duas populações: crianças que se encontravam na escola/domicilio e crianças que recorreram a uma urgência hospitalar. O estudo decorreu em dois períodos, de Fevereiro a Maio de 2011 e de Outubro de 2011 a Abril de 2012. Foram efetuadas duas colheitas de zaragatoas, uma nasal e outra orofaríngea. A metodologia utilizada para a identificação viral nas amostras foi a PCR e RT-PCR multiplex em tempo real. Os vírus pesquisados foram: Influenza A e B, Parainfluenza 1-4, Metapneumovirus humano, Vírus Sincicial respiratório (VSR), Rinovírus, Enterovírus, Coronavírus e Bocavirus. Foram realizadas 100 colheitas em crianças com idades compreendidas entre os 5 meses e os 5 anos. Foram obtidas 64 amostras dos infantários/domicílios, das quais 47 foram positivas. Da urgência Hospitalar obtiveram-se 36 amostras, em que 32 foram positivas. O vírus da gripe A (H3) foi o mais frequentemente detetado nas duas populações, mas apenas durante o surto de 2012. O VSR e os adenovírus foram mais frequentes nas crianças que recorreram ao hospital, ao contrário dos enterovirus e dos coronavírus, que não foram detetados nesta população. Os bocavirus nunca foram detetados isoladamente. Este estudo reforça a importância de se utilizarem técnicas de biologia molecular para o diagnóstico etiológico das infeções respiratórias, devido à elevada sensibilidade das mesmas, o que se reflete na elevada percentagem de amostras positivas. O facto de se utilizarem técnicas “multiplex”, que permitem a pesquisa simultânea de vários vírus, facilita a deteção de um maior espectro destes agentes. A elevada prevalência de Influenza A H3N2 deveu-se ao facto de grande parte do estudo ter coincidido com um período de surto por este vírus. O sistema de alerta montado durante o projeto ENVIRH pareceu promissor para uma eventual utilização futura em períodos de atividade gripal.--------------ABSTRACT: In the last decade, as respiratory viruses keep representing a relevant factor in child morbidity and mortality, the spectrum of viruses that may potentially cause respiratory infections has been widened. Within the several methodologies that may be applied in the diagnosis of these types of infections, the ones that use molecular biology are considered to be the most sensitive. The Environment and Health in Daycares and Nurseries Project (ENVIRH) arranged for a study, by means of molecular biology techniques, on the main respiratory viruses' influence in pre-school aged children with respiratory infection symptoms. This study compared children in two different populations: children at school or at home and children that were taken to a hospital emergency service. The study was conducted in two different time periods, one from February to May 2011 and the other from October 2011 to April 2012. During this time, two swab collections were held, one nasal and one oropharyngeal. PCR and RT-PCR multiplex in real time techniques were used for viral identification of the samples, searching for the viruses Influenza A and B, Parainfluenza 1-4, human Metapneumovirus, Respiratory Sincytial Virus (RSV), Rhinovirus, Enterovirus, Coronavirus and Bocavirus. One hundred (100) collections were held in children between the ages of 5 months and 5 years, sixty-four (64) at home/school and thirty-six (36) at the hospital's emergency service. From a total of seventy-nine (79) positive samples, forty-seven (47) were obtained at home/school and thirty-two (32) at the hospital. The virus detected the most in both populations was the Influenza A (H3), but only during the outbreak of 2012. Unlike the enteroviruses and coronaviruses, that were not detected within this population, the RSV and the adenoviruses were most common within the children at the hospital. Bocaviruses were never detected isolated from other viruses. The high percentage of positive samples reinforces the significance of using molecular biology techniques for the etiological diagnosis of respiratory infections. The use of multiplex techniques, that make the simultaneous search for multiple viruses possible, enhances the detection of a larger spectrum of such agents. Most of the study coincided with an outbreak of the Influenza A H3N2 virus, thus explaining the high number of its cases identified. The alert system set up during the ENVIRH project looked promising enough for eventual periods of flu activity in the future.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

RESUMO - O ozono é o principal componente da poluição fotoquímica do ar. Como agente irritante do aparelho respiratório, os seus efeitos sobre a saúde caracterizam-se, essencialmente, por tosse, dispneia, desconforto torácico e alterações da função pulmonar, encontrando-se também associadas à exposição ambiental a O3 tanto uma maior frequência e gravidade de crises de asma como a ocorrência de quadros clínicos de irritação conjuntival. É sobretudo a partir dos anos 50, com a descoberta de concentrações elevadas de ozono em ambientes de trabalho respeitantes à actividade de soldadura «a arco», que aquele gás passa a ser encarado como factor profissional de risco. No início dos anos 60 surgem os primeiros estudos de exposição a O3 em cabinas de avião, suscitados pela ocorrência, em tripulantes e passageiros, de queixas clínicas de irritação do tracto respiratório. Esta sintomatologia era, até então, atribuída à acção de outros factores, designadamente o sistema de ventilação e o baixo teor de humidade do ar. Posteriormente, alguns estudos revelaram que, em voos comerciais subsónicos, os teores elevados de O3 observados no interior das cabinas poderiam ser provocados pela sua insuficiente destruição nos sistemas de entrada de ar.O presente estudo, efectuado em voos de longo curso realizados em aeronaves Airbus A340-300 numa única rota comercial, teve por objectivo avaliar a exposição a ozono no ar interior em cabina de avião. Os teores médios de concentração de ozono observados foram inferiores aos valores susceptíveis de provocarem efeitos adversos sobre o aparelho respiratório. Como valor máximo instantâneo, foi atingida a concentração de 152 ppb. Adicionalmente, foi constatada a influência das estações do ano nos teores de O3. O conjunto dos resultados obtidos permite concluir que as concentrações de ozono no ar interior nas cabinas de avião estudadas são inferiores às correspondentes concentrações máximas admissíveis, tendo, em todos os voos, sido observado o cumprimento da norma da FAA respeitante à protecção da exposição ao ozono em cabinas de aeronaves de aviação comercial.