622 resultados para Reductive elution


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sunflower oil is one of the vegetable oils most susceptible to oxidative reaction. Therefore the presence of natural (tocopherol) and/or synthetic (TBHQ) antioxidants is a prerequisite to secure the stability of this oil during its shelf life, especially with the increased use of PET packaging. On determining the total tocopherol content in 10 samples of deodorized sunflower oils, high losses in total tocopherol during deodorization were identified. In order to facilitate researche involving oxidative stability of vegetable oils, a method for isolated quantification of TBHQ using the isocratic elution system was developed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of the present study was determining the main organic acids in pulp and juices, as well as evaluating their stability, after opening the package, by liquid chromatography in a C18 column with isocratic elution and UV detection. In açaí pulp tartaric, malic and citric acids were found. Cashew samples presented all of the organic acids evaluated, besides high concentrations of ascorbic and malic acids. Acerola pulp had the highest ascorbic acid concentration. A small decrease in organic acid content during storage was observed. Malic and citric acids seem to be more stable than tartaric and ascorbic acids.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple liquid chromatographic method for the simultaneous determination of creatinine, hippuric acid, mandelic acid, phenylglyoxylic acid and o, m and p-methylhippuric acids was developed and validated. Sample preparation was only dilution with water (1:10), followed by centrifugation. Analysis was performed in a reversed phase column (Lichrospher RP 8ec), 250 x 4.0 mm, with isocratic elution with phosphate buffer pH 2.3 and acetonitrile (90:10, v/v). The method presents adequate linearity, precision and accuracy and allows the simultaneous determination of the biomarkers of exposure to toluene, xylene and styrene together with creatinine, reducing cost and laboratory time.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes an experiment to teach the principles of gas chromatography exploring the boiling points and polarities to explain the elution order of a series of alcohols, benzene and n-propanone, as well as to teach the response factor concept and the internal standard addition method. Retention times and response factors are used for qualitative identification and quantitative analysis of a hypothetical contamination source in a simulated water sample. The internal standard n-propanol is further used for quantification of benzene and n-butanol in the water sample. This experiment has been taught in the instrumental analysis course offered to chemistry and oceanography students.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this study, different solutions to extract vitamin C were tested. High-performance liquid chromatography was chosen and the conditions were based on isocratic elution in reverse phase column. Dehydroascorbic acid was determined indirectly after its reduction using dithiothreitol. The use of metaphosphoric acid to stabilize the vitamin C was shown to be required and it was necessary to neutralize the pH of the extract to apply dithiothreitol. The average recovery was 90% in collard and tomato samples. The presence of oil did not interfere in extraction and the methodology can be used to analyze stir fried vegetables.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes the development and validation of simple and selective analytical method for determination of 3.4-methylenedioxymethamphetamine (MDMA) in Ecstasy tablets, using high performance liquid chromatography with fluorescence detection. Analysis was performed in a reversed phase column (LiChrospher 100 C18, 150 x 4.6 mm, 5 µm), isocratic elution with phosphate buffer 25 mmol/L pH 3.0 and acetonitrile (95:5, v/v). The method presents adequate linearity, selectivity, precision and accuracy. MDMA concentration in analyzed tablets showed a remarkable variability (from 8.5 to 59.5 mg/tablet) although the tablet weights were uniform, indicating poor manufacturing control thus imposing additional health risks to the users.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work the potentiality of reductive-oxidative processes based on zero-valent iron was studied aiming the degradation of nitroaromatic compounds and the remediation of residues from the explosive industry. The reductive process was applied as a continuous treatment system, using steel-wool as zero-valent iron source. The process permitted an almost total degradation of nitrobenzene, nitrophenol, nitrotoluene, dinitrotoluene and trinitrotoluene, probably with generation of the respective amine-derivative. The yellow-water residue, containing soluble trinitrotoluene, was notably modified by the reductive process, a fact that permitted a substantial enhancement of its biodegradability. Furthermore, the subsequent photo-Fenton process allowed TOC removal of about 80%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A method using ultrasonication extraction for the determination of 17 polycyclic aromatic hydrocarbons (PAHs), selected by the USEPA and NIOSH as "consent decree" priority pollutants, in soil by High Performance Liquid Chromatography (HPLC) was studied. Separation and detection were completed in 20 min with a C18 columm, acetonitrile-water gradient elution and ultraviolet absorption and fluorescence detections. The detection limits, for a 10 µL of solution injection, were less than 9,917 ng/g in UV detection and less than 1,866 ng/g in fluorescence detection. Several organic solvents were tested for extraction of the 17 PAHs from soils. Acetone was the best solvent among the three solvents tested, and the order of the extraction efficiencies was: acetone>methanol>acetonitrile. Ultrasonication using acetone as solvent extraction was used to evaluate the biodegradation of those compounds in contaminated soil during a vermicomposting process.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple ultra-performance liquid chromatographic method for the simultaneous determination of sildenafil citrate and tadalafil was developed and validated. Sample preparation was dissolution in methanol, followed by centrifugation and dilution (1:10) with methanol. Analysis was performed in an Acquity® UPLC system with Acquity® BEH C18 column (2.1 x 50 mm, with 1.7 μm particles). The elution was isocratic with phosphate buffer pH 2.3 and acetonitrile (65:35, v/v) at a flow rate of 0.7 mL/min. The method presented adequate specificity, linearity, precision and accuracy and allowed the determination of the drugs in seized forensic samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work the treatment of textile dyeing baths by a sequential reductive-oxidative process was evaluated, aiming its utilization in new dyeing process. The results demonstrated that reactive dyes can be easily degraded by reductive processes mediated by zero-valent iron, a fact that induces decolorizations of about 80%. Sequential photo-Fenton processes permit almost total removal of the residual color with elimination of 90% of the COD content. The reuse of treated residues permits the achievement of materials that attend practically all textile specifications, with exception of the color difference parameter (ΔE), which is unsatisfactory toward the importation standards, but adequate for the national market.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Reduction of camphor to a mixture of borneol and isoborneol was performed using NaBH4 as the reducing agent under suitable conditions. Although more effective reduction was accomplished using toxic methanol, an alternative non-toxic ethanolic system is described. This experiment is important to introduce undergraduate students in reductive procedures, and can be used to show details on stereoselective procedures on carbonyl moieties (facial diastereoselectivity, Bürgi-Dunitz trajectory, diastereomeric excess).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present work describes a novel stability-indicating reversed-phase ultra performance liquid chromatography method for the separation and quantification of rosuvastatin (RSV) and its related impurities in the pharmaceutical dosage forms under forced degradation conditions. An unknown degradation impurity detected in the acid degradation was identified by using quadrupole time-of-flight mass spectrometry. The chromatographic separation was carried out on C-18 column (100 x 2.1 mm, 1.7 μm) using isocratic elution with methanol and 0.1% trifluoroacetic acid (50:50). The total run time was 12 min within which RSV as well as all related impurities and degradation products were separated. The developed method was validated for RSV and related impurities in pharmaceutical dosage forms.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We optimized a method for the determination of three main folate isoforms in leafy vegetables. Analysis was carried out by HPLC, using gradient of elution and fluorescence detection. Limits of quantification were 2 ng/mL; 2 ng/mL and 28 ng/mL for tetrahydrofolate (THF), 5-methyltetrahydrofolate (5-MTHF) and 5-formyltetrahydrofolate (5-FTHF), respectively. Recovery rates of THF, 5-MTHF and 5-FTHF varied from 87.86 to 100.64%; 88.12-94.22% and 89.82-106.69%, respectively. Test of repeatability showed relative standard deviation for peak areas lower than 10%. Tests for linearity showed high coefficients of determination. The results showed advances in folates extraction and analysis in raw and cooked leafy vegetables.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work presents simple routes to recover iodine compounds from oxidized laboratory chemicals and aqueous solutions (HI and KI) used in laboratory chemistry classes. These routes are based on the oxidation of iodide ions (I-) to iodine (I2) by an oxidant (H2O2) or reduction of oxidized iodine by red phosphorus or hydrazine. Both routes presented high yields. The oxidative route is of general use whereas the reductive one is appropriate for restoring original iodine reagents. Final wastes were generated in low amounts. This work is appropriate for teaching many laboratory techniques (e.g., distillation, titration and filtration) in the chemical laboratory.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We investigated the biological decolourisation of dyes with different molecular structures. The kinetic constant values (k1) achieved with azo dye Reactive Red 120 were 7.6 and 10.1 times higher in the presence of RM (redox mediators) AQDS and riboflavin, respectively, than the assays lacking RM. The kinetic constant achieved with the azo dye Congo Red was 42 times higher than that obtained with the anthraquinone dye Reactive Blue 4. The effect of RM on dye reduction was more evident for azo dyes resistant to reductive processes, and ineffective for anthraquinone dyes because of the structural stability of the latter.