958 resultados para Rapid spectroscopic method


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mestrado em Medicina Nuclear.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A QuEChERS method has been developed for the determination of 14 organochlorine pesticides in 14 soils from different Portuguese regions with wide range composition. The extracts were analysed by GC-ECD (where GC-ECD is gas chromatography-electron-capture detector) and confirmed by GC-MS/MS (where MS/MS is tandem mass spectrometry). The organic matter content is a key factor in the process efficiency. An optimization was carried out according to soils organic carbon level, divided in two groups: HS (organic carbon>2.3%) and LS (organic carbon<2.3%). Themethod was validated through linearity, recovery, precision and accuracy studies. The quantification was carried out using a matrixmatched calibration to minimize the existence of the matrix effect. Acceptable recoveries were obtained (70–120%) with a relative standard deviation of ≤16% for the three levels of contamination. The ranges of the limits of detection and of the limits of quantification in soils HS were from 3.42 to 23.77 μg kg−1 and from 11.41 to 79.23 μg kg−1, respectively. For LS soils, the limits of detection ranged from 6.11 to 14.78 μg kg−1 and the limits of quantification from 20.37 to 49.27 μg kg−1. In the 14 collected soil samples only one showed a residue of dieldrin (45.36 μg kg−1) above the limit of quantification. This methodology combines the advantages of QuEChERS, GC-ECD detection and GC-MS/MS confirmation producing a very rapid, sensitive and reliable procedure which can be applied in routine analytical laboratories.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A flow-spectrophotometric method is proposed for the routine determination of tartaric acid in wines. The reaction between tartaric acid and vanadate in acetic media is carried out in flowing conditions and the subsequent colored complex is monitored at 475 nm. The stability of the complex and the corresponding formation constant are presented. The effect of wavelength and pH was evaluated by batch experiments. The selected conditions were transposed to a flowinjection analytical system. Optimization of several flow parameters such as reactor lengths, flow-rate and injection volume was carried out. Using optimized conditions, a linear behavior was observed up to 1000 µg mL-1 tartaric acid, with a molar extinction coefficient of 450 L mg-1 cm-1 and ± 1 % repeatability. Sample throughput was 25 samples per hour. The flow-spectrophotometric method was satisfactorily applied to the quantification of tartaric acid (TA) in wines from different sources. Its accuracy was confirmed by statistical comparison to the conventional Rebelein procedure and to a certified analytical method carried out in a routine laboratory.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A new procedure for determining eleven organochlorine pesticides in soils using microwave-assisted extraction (MAE) and headspace solid phase microextraction (HS-SPME) is described. The studied pesticides consisted of mirex, α- and γ-chlordane, p,p’-DDT, heptachlor, heptachlor epoxide isomer A, γ-hexachlorocyclohexane, dieldrin, endrin, aldrine and hexachlorobenzene. The HS-SPME was optimized for the most important parameters such as extraction time, sample volume and temperature. The present analytical procedure requires a reduced volume of organic solvents and avoids the need for extract clean-up steps. For optimized conditions the limits of detection for the method ranged from 0.02 to 3.6 ng/g, intermediate precision ranged from 14 to 36% (as CV%), and the recovery from 8 up to 51%. The proposed methodology can be used in the rapid screening of soil for the presence of the selected pesticides, and was applied to landfill soil samples.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Reporter genes are routinely used in every laboratory for molecular and cellular biology for studying heterologous gene expression and general cellular biological mechanisms, such as transfection processes. Although well characterized and broadly implemented, reporter genes present serious limitations, either by involving time-consuming procedures or by presenting possible side effects on the expression of the heterologous gene or even in the general cellular metabolism. Fourier transform mid-infrared (FT-MIR) spectroscopy was evaluated to simultaneously analyze in a rapid (minutes) and high-throughput mode (using 96-wells microplates), the transfection efficiency, and the effect of the transfection process on the host cell biochemical composition and metabolism. Semi-adherent HEK and adherent AGS cell lines, transfected with the plasmid pVAX-GFP using Lipofectamine, were used as model systems. Good partial least squares (PLS) models were built to estimate the transfection efficiency, either considering each cell line independently (R 2 ≥ 0.92; RMSECV ≤ 2 %) or simultaneously considering both cell lines (R 2 = 0.90; RMSECV = 2 %). Additionally, the effect of the transfection process on the HEK cell biochemical and metabolic features could be evaluated directly from the FT-IR spectra. Due to the high sensitivity of the technique, it was also possible to discriminate the effect of the transfection process from the transfection reagent on KEK cells, e.g., by the analysis of spectral biomarkers and biochemical and metabolic features. The present results are far beyond what any reporter gene assay or other specific probe can offer for these purposes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

With the objective of standardizing a Dot Enzyme-Linked Immunosorbent Assay (Dot-ELISA) to detect antigens of fecal bacterial enteropathogens, 250 children, aged under 36 months and of both sexes, were studied; of which 162 had acute gastroenteritis. The efficacy of a rapid screening assay for bacterial enteropathogens (enteropathogenic Escherichia coli "EPEC", enteroinvasive Escherichia coli "EIEC", Salmonella spp. and Shigella spp.) was evaluated. The fecal samples were also submitted to a traditional method of stool culture for comparison. The concordance index between the two techniques, calculated using the Kappa (k) index for the above mentioned bacterial strains was 0.8859, 0.9055, 0.7932 and 0.7829 respectively. These values express an almost perfect degree of concordance for the first two and substantial concordance for the latter two, thus enabling this technique to be applied in the early diagnosis of diarrhea in infants. With a view to increasing the sensitivity and specificity of this immunological test, a study was made of the antigenic preparations obtained from two types of treatment: 1) deproteinization by heating; 2) precipitation and concentration of the lipopolysaccharide antigen (LPS) using an ethanol-acetone solution, which was then heated in the presence of sodium EDTA

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In occupational accidents involving health professionals handling potentially contaminated material, the decision to start or to continue prophylactic medication against infection by Human Immunodeficiency Virus (HIV) has been based on the ELISA test applied to a blood sample from the source patient. In order to rationalize the prophylactic use of antiretroviral agents, a rapid serologic diagnostic test of HIV infection was tested by the enzymatic immunoabsorption method (SUDS HIV 1+2, MUREX®) and compared to conventional ELISA (Abbott HIV-1/ HIV-2 3rd Generation plus EIA®). A total of 592 cases of occupational accidents were recorded at the University Hospital of Ribeirão Preto from July 1998 to April 1999. Of these, 109 were simultaneously evaluated by the rapid test and by ELISA HIV. The rapid test was positive in three cases and was confirmed by ELISA and in one the result was inconclusive and later found to be negative by ELISA. In the 106 accidents in which the rapid test was negative no prophylactic medication was instituted, with an estimated reduction in costs of US$ 2,889.35. In addition to this advantage, the good correlation of the rapid test with ELISA, the shorter duration of stress and the absence of exposure of the health worker to the adverse effects of antiretroviral agents suggest the adoption of this test in Programs of Attention to Accidents with Potentially Contaminated Material.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study evaluated the whole blood immunochromatographic card test (ICT card test) in a survey performed in Northeastern Brazil. 625 people were examined by the thick blood film (TBF) and ICT card test. Residents of a non-endemic area were also tested by the whole blood card test and Og4C3. The sensitivity of the ICT card test was 94.7% overall, but lower in females than males, based on the reasonable assumption that TBF is 100% specific. However, since TBF and other methods have unknown sensitivity, the true specificity of the card test is unknown. Nevertheless, it is possible to estimate upper and lower limits for the specificity, and relate it to the prevalence of the disease. In the endemic area, the possible range of the specificity was from 72.4% to 100%. 29.6% of the card tests performed in the non-endemic area exhibited faint lines that were interpreted as positives. Characteristics of the method including high sensitivity, promptness and simplicity justify its use for screening of filariasis. However, detailed information about the correct interpretation in case of extremely faint lines is essential. Further studies designed to consider problems arising from imperfect standards are necessary, as is a sounder diagnostic definition for the card test.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Potentiometric detection with homemade polymeric membrane microelectrodes was coupled to a magnetic sandwich immunoassay for Salmonella typhimurium determination. Cadmium and sodium ion selective electrodes were used respectively as indicator and pseudo-reference electrodes and were prepared in pipette tips to allow potentiometric measurements in microliter sample volumes. In the proposed method, the concentration of S. typhimurium was proportional to the amount of cadmium released upon dissolution of a CdS nanoparticle labeled to the secondary detection antibody. The limit of detection was 2 cells per 100 μL. The immunomagnetic assay with potentiometric detection is suitable for sensitive and rapid (average total time per assay of 75 minutes) detection of S. typhimurium in milk samples. The proposed method is easy to perform, safe, sensitive, and low cost and has potential for in situ analysis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this study a citrate-buffered version of QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) method for determination of 14 organochlorine pesticides (OCPs) residues in tamarind peel, fruit and commercial pulp was optimized using gas chromatography (GC) coupled with electron-capture detector (ECD) and confirmation by GC tandem mass spectrometry (GC–MS/MS). Five procedures were tested based on the original QuEChERS method. The best one was achieved with increased time in ultrasonic bath. For the extract clean-up, primary secondary amine (PSA), octadecyl-bonded silica (C18) and magnesium sulphate (MgSO4) were used as sorbents for tamarind fruit and commercial pulp and for peel was also added graphitized carbon black (GCB). The samples mass was optimized according to the best recoveries (1.0 g for peel and fruit; 0.5 g for pulp). The method results showed the matrix-matched calibration curve linearity was r2 > 0.99 for all target analytes in all samples. The overall average recoveries (spiked at 20, 40 and 60 μg kg−1) have been considered satisfactory presenting values between 70 and 115% with RSD of 2–15 % (n = 3) for all analytes, with the exception of HCB (in peel sample). The ranges of limits of detection (LOD) and quantification (LOQ) for OCPs were for peel (LOD: 8.0–21 μg kg−1; LOQ: 27–98 μg kg−1); for fruit (LOD: 4–10 μg kg−1; LOQ: 15–49 μg kg−1) and for commercial pulp (LOD: 2–5 μg kg−1; LOQ: 7–27 μg kg−1). The method was successfully applied in tamarind samples being considered a rapid, sensitive and reliable procedure.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertation to obtain the Master Degree in Biotechnology

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction The early diagnosis of mycobacterial infections is a critical step for initiating treatment and curing the patient. Molecular analytical methods have led to considerable improvements in the speed and accuracy of mycobacteria detection. Methods The purpose of this study was to evaluate a multiplex polymerase chain reaction system using mycobacterial strains as an auxiliary tool in the differential diagnosis of tuberculosis and diseases caused by nontuberculous mycobacteria (NTM) Results Forty mycobacterial strains isolated from pulmonary and extrapulmonary origin specimens from 37 patients diagnosed with tuberculosis were processed. Using phenotypic and biochemical characteristics of the 40 mycobacteria isolated in LJ medium, 57.5% (n=23) were characterized as the Mycobacterium tuberculosis complex (MTBC) and 20% (n=8) as nontuberculous mycobacteria (NTM), with 22.5% (n=9) of the results being inconclusive. When the results of the phenotypic and biochemical tests in 30 strains of mycobacteria were compared with the results of the multiplex PCR, there was 100% concordance in the identification of the MTBC and NTM species, respectively. A total of 32.5% (n=13) of the samples in multiplex PCR exhibited a molecular pattern consistent with NTM, thus disagreeing with the final diagnosis from the attending physician. Conclusions Multiplex PCR can be used as a differential method for determining TB infections caused by NTM a valuable tool in reducing the time necessary to make clinical diagnoses and begin treatment. It is also useful for identifying species that were previously not identifiable using conventional biochemical and phenotypic techniques.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A pictorial field guide to the 30 species of sandfly most commonly encountered in Pará State is presented, based on the easily recognised external characters of the length of the 5th palpal segment, thoracic infuscation, abdominal colour and head and body size. In most cases this allows identification to the species. In others, especially with females, it gives an indication of the species, which may then be confirmed with data from more detailed taxanomix studies. This type of field guide helps in teaching, rapid sorting of flies prior to dissection and in acquainting visitors with the variety of species present in a given area.A rapid technique for the taxonomic sorting of unmounted, freshly killed female sandflies is required, prior to the dissection of large numbers of a particular species. Such a method is useful in areas where numerous species occur in studies on natural flagellate infections, age determination and for ecological studies. With the above points in mind a pictorial field guide has been designed that enables the identification of unmounted, unmacerated specimens of the 30 more commonly encountered species of phleboto-mine sandflies (***) in Pará State, North Brazil. It is based on the easily recognised external characters of the length of the 5th palpal segment, thoracic infuscation, ad-dominal colour and proboscis and body size.Taxonomy of male phlebotomine sandflies is based on the structure of the genitalia and, as most of this is external, a wholly external character key is readily made. Female taxonomy, however, is based on the internal character of the cibarium, pharynx and sperma thecae. In order to produce an external character key we therefore return to an unso phisticated "phlebotometry" (see Martins et al., 1978 p. 3 for review), using relative lengths of the proboscis, palpal segments and body, along with the degree of infuscation. Ihis idea is not new; indeed many sandfly specialists presently use external characters to separate certain species (H. Fraiha, R. P. Lane, P. D. Ready, D. G. Young and R. D. Ward personal communications 1983 & 1984).A key used to separate five anthropophillic sandflies by Biagi (1966), in Mexico, was based mainly on palpal segment length and infuscation. Floch and Abonnenc (1952) stressed the use of relative lengths of palpal segments in their keys to the sandflies of French Guiana, and four members of the shannoni group have been similarly separated according to the degree of infuscation by Morales et al. (1982). The use of thoracic infuscation as a reliable character seems to be gaining favour, having been used by young & Fairchild (1974) and Ready & Fraiha (1981). Indeed Chariotis 1974) showed the usefulness of thoracic infuscation to sepenate 7 anthropophillic species, during studies onvesicular stomatitis in Panama. Identification using external characters is essential for work on viral isolations from sandflies, where bulk samples of whole sandflies are used.Perhaps the major advantage of a simple visual guide is for teaching purposes. Technical staff in this lnstitute are able to identify most of the species they encounter without having to use the standard, more unwieldly (and in many cases unavailable) internal character keys, and the guides presented below have allowed rapid species sorting prior to the dissection of sandflies in our leismaniasis study areas (Ryan et at. ,1985).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Injectable biomaterials with in situ cross-linking reactions have been suggested to minimize the invasiveness associated with most implantation procedures. However, problems related with the rapid liquid-to-gel transition reaction can arise because it is difficult to predict the reliability of the reaction and its end products, as well as to mitigate cytotoxicity to the surrounding tissues. An alternative minimally invasive approach to deliver solid implants in vivo is based on injectable microparticles, which can be processed in vitro with high fidelity and reliability, while showing low cytotoxicity. Their delivery to the defect can be performed by injection through a small diameter syringe needle. We present a new methodology for the continuous, solvent- and oil-free production of photopolymerizable microparticles containing encapsulated human dermal fibroblasts. A precursor solution of cells in photo-reactive PEG-fibrinogen (PF) polymer was transported through a transparent injector exposed to light-irradiation before being atomized in a jet-in-air nozzle. Shear rheometry data provided the cross-linking kinetics of each PF/cell solution, which was then used to determine the amount of irradiation required to partially polymerize the mixture prior to atomization. The partially polymerized drops fell into a gelation bath for further polymerization. The system was capable of producing cell-laden microparticles with high cellular viability, with an average diameter of between 88.1 µm to 347.1 µm and a dispersity of between 1.1 and 2.4, depending on the parameters chosen.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The regular use of the computer in the office contributed to the appearance of many risk factors related with work-related musculoskeletal disorders (WRMSD) such as maintaining static sitting postures for long time and awkward postures of the head, neck and upper limbs, leading to increased muscle activity in the cervical spine and shoulders. The objective of this study was to evaluate the presence of risk factors for WRMSD in an office using the Rapid Assessment Office Strain method (ROSA). Based on the results of this ergonomic evaluation, an occupational gym program was designed and implemented. Thirty-eight workplaces were evaluated using the observation of the tasks and pictures records in order to characterize those tasks in more detail. The ROSA tool was applied by an observer, who selected the appropriate score based on the worker's posture as well as the time spent in each posture. Scores were recorded for the sections of the method, specifically Chair, Monitor and Mouse and Keyboard and Telephone. The scores were recorded in a sheet developed for the method. The mean ROSA final score was 3.61 ± 0.64, for Chair section was 3.45 ± 0.55, to Monitor and Telephone section was 3.11 ± 0.61, and to Mouse and Keyboard section was 2.11 ± 0.31. The results led to understand that the analyzed tasks represent situations of risk of discomfort and, according to the methods guidelines, further research and modifications of the workplace may be necessary. It should be emphasized that these scores may not be related to the poor available equipment but with the need to optimize their use by the workers. It was noticed also that the interaction of workers with the tasks and the adopted sitting posture at the computer throughout the day have effects at a muscular level, essentially for the cervical area and shoulders. ROSA tool is an useful and easy method to assess several risk factors associated with WRMSD, also allowing the design of specific occupational gym programs.