859 resultados para Rapid programming
Resumo:
Teaching and learning computer programming is as challenging as difficult. Assessing the work of students and providing individualised feedback to all is time-consuming and error prone for teachers and frequently involves a time delay. The existent tools and specifications prove to be insufficient in complex evaluation domains where there is a greater need to practice. At the same time Massive Open Online Courses (MOOC) are appearing revealing a new way of learning, more dynamic and more accessible. However this new paradigm raises serious questions regarding the monitoring of student progress and its timely feedback. This paper provides a conceptual design model for a computer programming learning environment. This environment uses the portal interface design model gathering information from a network of services such as repositories and program evaluators. The design model includes also the integration with learning management systems, a central piece in the MOOC realm, endowing the model with characteristics such as scalability, collaboration and interoperability. This model is not limited to the domain of computer programming and can be adapted to any complex area that requires systematic evaluation with immediate feedback.
Resumo:
Empreendimentos industriais requerem o acompanhamento completo e preciso de dados de máquinas em tempo real, integrando as atividades do chão de fábrica com a engenharia, suporte e negócios. É reconhecido que sistemas de monitorização são fundamentais para melhorar a qualidade do produto, reduzir os tempos e para a adaptação rápida às mudanças de produção. Os sensores de processos possuem custos altos, não são compactos e são de difícil implementação. Portanto, seria estratégico desenvolver sistemas de monitorização que usufruem ao máximo dos recursos já existentes nas máquinas e ferramentas e que não representem custos adicionais elevados e de difícil implementação. O uso de PLC nas indústrias é crescente. Estes mostram-se como ferramentas potenciais para atender a estas exigências. Os PLC possuem os recursos necessários para a aquisição de informações e controlo das máquinas, facilitando a interação com um sistema SCADA. O objetivo do presente trabalho é pesquisar soluções sobre sistemas de monitorização que possam substituir um sistema instalado antiquado e encontrar uma solução para o controlo de um processo de vazamento. Para tal, foram consideradas duas soluções: uma passaria por desenvolver um sistema de monitorização que controlasse o processo de vazamento, e outra que permitisse ser o PLC a fazer o controlo, adquirindo um HMI apenas para monitorização. Esta última solução revelou-se como a melhor, visto que um PLC tem mais durabilidade em relação a um PC, em termos de atualizações de hardware e software. Assim, foram criadas funções no PLC para fazer o controlo de vazamento e foi adquirido uma consola Beijer, e respetivo software de programação SCADA, para a criação do sistema de monitorização. Os resultados mostram que o PLC é capaz de executar o controlo, não sendo necessário investir em PC que são mais caros, bastando para isso adquirir sistemas SCADA simples e capazes.
Resumo:
Potentiometric detection with homemade polymeric membrane microelectrodes was coupled to a magnetic sandwich immunoassay for Salmonella typhimurium determination. Cadmium and sodium ion selective electrodes were used respectively as indicator and pseudo-reference electrodes and were prepared in pipette tips to allow potentiometric measurements in microliter sample volumes. In the proposed method, the concentration of S. typhimurium was proportional to the amount of cadmium released upon dissolution of a CdS nanoparticle labeled to the secondary detection antibody. The limit of detection was 2 cells per 100 μL. The immunomagnetic assay with potentiometric detection is suitable for sensitive and rapid (average total time per assay of 75 minutes) detection of S. typhimurium in milk samples. The proposed method is easy to perform, safe, sensitive, and low cost and has potential for in situ analysis.
Resumo:
A significant number of Brazilian gestational-age women are still not tested for HIV, representing a high risk of transmission to their newborns. The current study sought to identify the number of pregnant women with no previous testing or undocumented for HIV referred to the Gynecology and Obstetrics Department of a Regional Teaching Hospital and included diagnosis of HIV infection determined by a rapid test and perinatal transmission in pregnancy. Medical records of all pregnant women admitted to hospital from January 2001 to December 2005 were reviewed. Pregnant women without HIV results were submitted to a rapid HIV test. Those who tested positive were further tested by ELISA and confirmed by indirect immunofluorescence assay (IIA) or Western blot (WB). The viral load from babies born to HIV-infected mothers was assessed by bDNA. Of the 16,424 pregnant women analyzed (6.6%), 1,089 were undocumented for HIV. Eleven women were positive in rapid testing and 10 were confirmed by ELISA, IIA or WB, with 0.9% seropositivity. Mother/infant pairs received zidovudine monotherapy prophylaxis and infant viral load was lower than 50 copies/mL. A higher number of pregnant women previously tested for HIV during antenatal care was verified, compared to that obtained nationwide.
Resumo:
The aim of this study was to validate the rapid lateral flow Helicobacter pylori stool antigen test (One step H. pylori antigen test, ACON laboratories, San Diego, USA; Prime diagnostics, São Paulo), using 13C-Urea Breath Test as the gold standard for H. pylori infection diagnosis. A total of 98 consecutive patients, asymptomatic or dyspeptic, entered the study. Sixty-nine were women, with a mean age of 45.76 ± 14.59 years (14 to 79 years). In the H. pylori-positive group, the rapid stool antigen test detected H. pylori antigen in 44 of the 50 positive patients (sensitivity 88%; 95% CI: 75.7-95.5%), and six false-negative; and in the H. pylori-negative group 42 presented negative results (specificity 87.5%; 95% CI: 74.7-95.3%), and six false-positive, showing a substantial agreement (Kappa Index = 0.75; p < 0.0001; 95% CI: 0.6-0.9). Forty four of fifty patients that had positive stool antigen were H. pylori-positive, the PPV of the stool antigen test was 88% (95% CI: 75.7-95.5%), and 42 patients with negative stool antigen test were H. pylori-negative, the NPV of the stool antigen test was 87.5% (95% CI: 74.7-95.3%). We conclude that the lateral flow stool antigen test can be used as an alternative to breath test for H. pylori infection diagnosis especially in developing countries.
Resumo:
A new iterative algorithm based on the inexact-restoration (IR) approach combined with the filter strategy to solve nonlinear constrained optimization problems is presented. The high level algorithm is suggested by Gonzaga et al. (SIAM J. Optim. 14:646–669, 2003) but not yet implement—the internal algorithms are not proposed. The filter, a new concept introduced by Fletcher and Leyffer (Math. Program. Ser. A 91:239–269, 2002), replaces the merit function avoiding the penalty parameter estimation and the difficulties related to the nondifferentiability. In the IR approach two independent phases are performed in each iteration, the feasibility and the optimality phases. The line search filter is combined with the first one phase to generate a “more feasible” point, and then it is used in the optimality phase to reach an “optimal” point. Numerical experiences with a collection of AMPL problems and a performance comparison with IPOPT are provided.
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Biomédica
Resumo:
Trabalho de projecto apresentado como requisito parcial para obtenção do grau de Mestre em Estatística e Gestão de Informação
Resumo:
The use of cryotherapy as an adjunct to systemic antimonial therapy (Clucantime) was studied in 17 patients with a total of23 skin lesions of leishmaniasis in an area where L. braziliensis braziliensis is the species in circulation. Cryotherapy did not speed healing and has been discarded as an auxiliary therapeutic measure in our practice. However this technique may be suitable for species o/Leishmania causing more limited superficial lesions in man without the danger of metastasis.
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Informática
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Informática
Resumo:
Mycobaterium leprae infection was investigated in armadillos from the State of Espírito Santo, Brazil. The ML Flow test was performed on 37 nine-banded armadillos and positive results were found in 11 (29.7%). The ML Flow test may be used to identify possible sources of Mycobaterium leprae among wild armadillos.