919 resultados para Quality levels
Resumo:
The present study arose from the need to determine inorganic arsenic (iAs) at low levels in cereal-based food. Validated methods with a low limit of detection (LOD) are required to analyse these kinds of food. An analytical method for the determination of iAs, methylarsonic acid (MA) and dimethylarsinic acid (DMA) in cereal-based food and infant cereals is reported. The method was optimised and validated to achieve low LODs. Ion chromatography-inductively coupled plasma mass spectrometry (LC-ICPMS) was used for arsenic speciation. The main quality parameters were established. To expand the applicability of the method, different cereal products were analysed: bread, biscuits, breakfast cereals, wheat flour, corn snacks, pasta and infant cereals. The total and inorganic arsenic content of 29 cereal-based food samples ranged between 3.7-35.6 and 3.1-26.0 microg As kg-1, respectively. The present method could be considered a valuable tool for assessing inorganic arsenic contents in cereal-based foods.
Resumo:
A gas chromatography-mass spectrometry method is presented which allows the simultaneous determination of the plasma concentrations of the selective serotonin reuptake inhibitors citalopram, paroxetine, sertraline, and their pharmacologically active N-demethylated metabolites (desmethylcitalopram, didesmethylcitalopram, and desmethylsertraline) after derivatization with the reagent N-methyl-bis(trifluoroacetamide). No interferences from endogenous compounds are observed following the extraction of plasma samples from six different human subjects. The standard curves are linear over a working range of 10-500 ng/mL for citalopram, 10-300 ng/mL for desmethylcitalopram, 5-60 ng/mL for didesmethylcitalopram, 20-400 ng/mL for sertraline and desmethylsertraline, and 10-200 ng/mL for paroxetine. Recoveries measured at three concentrations range from 81 to 118% for the tertiary amines (citalopram and the internal standard methylmaprotiline), 73 to 95% for the secondary amines (desmethylcitalopram, paroxetine and sertraline), and 39 to 66% for the primary amines (didesmethylcitalopram and desmethylsertraline). Intra- and interday coefficients of variation determined at three concentrations range from 3 to 11% for citalopram and its metabolites, 4 to 15% for paroxetine, and 5 to 13% for sertraline and desmethylsertraline. The limits of quantitation of the method are 2 ng/mL for citalopram and paroxetine, 1 ng/mL for sertraline, and 0.5 ng/mL for desmethylcitalopram, didesmethylcitalopram, and desmethylsertraline. No interferences are noted from 20 other psychotropic drugs. This sensitive and specific method can be used for single-dose pharmacokinetics. It is also useful for therapeutic drug monitoring of these three drugs and could possibly be adapted for the quantitation of the two other selective serotonin reuptake inhibitors on the market, namely fluoxetine and fluvoxamine.
Resumo:
A noise wall was investigated to assess its effect on snow accumulation and air quality. Wind tunnel studies were undertaken to evaluate (a) possible snow accumulations and (b) the dispersion of particulate concentrations (dust, smoke, and lead particles) and carbon monoxide. Full-scale monitoring of particulate concentrations and carbon monoxide was performed both before and after the noise wall was constructed. The wind tunnel experiments for snow accumulation were conducted on a model wall located in a flat, unobstructed area. A separated flow zone existed upwind of the wall and snow immediately began to accumulate over most of the separated zone. Having the noise wall in an aerodynamically rough area, such as in an urban area as this one was, substantially decreased the amount of snow collected, compared with in the wind tunnel studies, because of turbulence reducing the separation zone. The snow accumulation has not been significantly greater with the noise wall in place than it was before construction and has proven to be of no concern to date. Monitoring for particulate concentrations has shown that the noise wall has had a beneficial effect because the amount of material collected was reduced. With the noise wall in place, monitoring for carbon monoxide has indicated that (a) for equivalent emissions under conditions of high atmospheric stability and low wind speeds, the carbon monoxide levels would be lower; and (b) under conditions of low atmospheric stability and high wind speeds, the carbon monoxide levels would be higher than expected without the wall in place.
Resumo:
PURPOSE: EOS (EOS imaging S.A, Paris, France) is an x-ray imaging system that uses slot-scanning technology in order to optimize the trade-off between image quality and dose. The goal of this study was to characterize the EOS system in terms of occupational exposure, organ doses to patients as well as image quality for full spine examinations. METHODS: Occupational exposure was determined by measuring the ambient dose equivalents in the radiological room during a standard full spine examination. The patient dosimetry was performed using anthropomorphic phantoms representing an adolescent and a five-year-old child. The organ doses were measured with thermoluminescent detectors and then used to calculate effective doses. Patient exposure with EOS was then compared to dose levels reported for conventional radiological systems. Image quality was assessed in terms of spatial resolution and different noise contributions to evaluate the detector's performances of the system. The spatial-frequency signal transfer efficiency of the imaging system was quantified by the detective quantum efficiency (DQE). RESULTS: The use of a protective apron when the medical staff or parents have to stand near to the cubicle in the radiological room is recommended. The estimated effective dose to patients undergoing a full spine examination with the EOS system was 290μSv for an adult and 200 μSv for a child. MTF and NPS are nonisotropic, with higher values in the scanning direction; they are in addition energy-dependent, but scanning speed independent. The system was shown to be quantum-limited, with a maximum DQE of 13%. The relevance of the DQE for slot-scanning system has been addressed. CONCLUSIONS: As a summary, the estimated effective dose was 290μSv for an adult; the image quality remains comparable to conventional systems.
Treatment intensification and risk factor control: toward more clinically relevant quality measures.
Resumo:
BACKGROUND: Intensification of pharmacotherapy in persons with poorly controlled chronic conditions has been proposed as a clinically meaningful process measure of quality. OBJECTIVE: To validate measures of treatment intensification by evaluating their associations with subsequent control in hypertension, hyperlipidemia, and diabetes mellitus across 35 medical facility populations in Kaiser Permanente, Northern California. DESIGN: Hierarchical analyses of associations of improvements in facility-level treatment intensification rates from 2001 to 2003 with patient-level risk factor levels at the end of 2003. PATIENTS: Members (515,072 and 626,130; age >20 years) with hypertension, hyperlipidemia, and/or diabetes mellitus in 2001 and 2003, respectively. MEASUREMENTS: Treatment intensification for each risk factor defined as an increase in number of drug classes prescribed, of dosage for at least 1 drug, or switching to a drug from another class within 3 months of observed poor risk factor control. RESULTS: Facility-level improvements in treatment intensification rates between 2001 and 2003 were strongly associated with greater likelihood of being in control at the end of 2003 (P < or = 0.05 for each risk factor) after adjustment for patient- and facility-level covariates. Compared with facility rankings based solely on control, addition of percentages of poorly controlled patients who received treatment intensification changed 2003 rankings substantially: 14%, 51%, and 29% of the facilities changed ranks by 5 or more positions for hypertension, hyperlipidemia, and diabetes, respectively. CONCLUSIONS: Treatment intensification is tightly linked to improved control. Thus, it deserves consideration as a process measure for motivating quality improvement and possibly for measuring clinical performance.
Resumo:
RATIONALE:We investigated the impact of canakinumab, a fully human anti-interleukin-1b monoclonal antibody on inflammation and HRQoL in gouty arthritis patients.METHODS: In this 8-week, single-blind, dose-ranging study, patients with acute gouty arthritis flares, unresponsive/intolerant or contraindicated to NSAIDs and/or colchicine were randomized to single subcutaneous canakinumab (10, 25, 50, 90, or 150mg, N5143) or single intramuscular triamcinolone acetonide (TA, 40mg, N557). Patients assessed pain (Likert scale), physicians assessed clinical signs of joint inflammation, and HRQoL was recorded using SF-36.RESULTS: At baseline, 98% patients had moderate-to-extreme pain, 85% had moderate/severe joint swelling, 64-79% had elevated inflammatory markers and HRQoL scores indicated impaired physical function. Percentage of patients with no/mild pain was numerically greater in most canakinumab groups vs. TA, 24-72h post-dose; difference significant for 150mg group at these time-points (P<0.05). Canakinumab 150mg was associated with significantly lower Likert scores for tenderness [OR, 3.2; 95% CI, 1.27-7.89; P50.014] and swelling (OR, 2.7; 95% CI, 1.09-6.50, P50.032) at 72h vs. TA; erythema was not different. Median CRP and SAA levels normalized by 7 days post-dose in most canakinumab groups, but remained elevated in TA. Physical function improved at 7 days postdose in all groups, highest improvement for canakinumab 150mg. SF-36 scores for physical functioning and bodily pain with canakinumab 150mg approached US general population scores by 7 days post-dose and exceeded normal values by 8 weeks post-dose.CONCLUSION: Canakinumab 150mg produced significantly greater and rapid pain-relief and improvements in HRQoL vs. TAin acute gouty arthritis patients.
Resumo:
Aims: The psychometric properties of the EORTC QLQ-BN20, a brain cancer-specific HRQOL questionnaire, have been previously determined in an English-speaking sample of patients. This study examined the validity and reliability of the questionnaire in a multi-national, multi-lingual study. Methods: QLQ-BN20 data were selected from two completed phase III EORTC/NCIC clinical trials in brain cancer (N=891), including 12 languages. Experimental treatments were surgery followed by radiotherapy (RT) and adjuvant PCV chemotherapy or surgery followed by concomitant RT plus temozolomide (TMZ) chemotherapy and adjuvant TMZ chemotherapy. Standard treatment consisted of surgery and postoperative RT alone. The psychometrics of the QLQ-BN20 were examined by means of multi-trait scaling analyses, reliability estimation, known groups validity testing, and responsiveness analysis. Results: All QLQ-BN20 items correlated more strongly with their own scale (r>0.70) than with other QLQ-BN20 scales. Internal consistency reliability coefficients were high (all alpha0.70). Known-groups comparisons yielded positive results, with the QLQ-BN20 distinguishing between patients with differing levels of performance status and mental functioning. Responsiveness of the questionnaire to changes over time was acceptable. Conclusion: The QLQ-BN20 demonstrates adequate psychometric properties and can be recommended for use in conjunction with the QLQ-C30 in assessing the HRQOL of brain cancer patients in international studies.
Resumo:
BACKGROUND: Assessment of the proportion of patients with well controlled cardiovascular risk factors underestimates the proportion of patients receiving high quality of care. Evaluating whether physicians respond appropriately to poor risk factor control gives a different picture of quality of care. We assessed physician response to control cardiovascular risk factors, as well as markers of potential overtreatment in Switzerland, a country with universal healthcare coverage but without systematic quality monitoring, annual report cards on quality of care or financial incentives to improve quality. METHODS: We performed a retrospective cohort study of 1002 randomly selected patients aged 50-80 years from four university primary care settings in Switzerland. For hypertension, dyslipidemia and diabetes mellitus, we first measured proportions in control, then assessed therapy modifications among those in poor control. "Appropriate clinical action" was defined as a therapy modification or return to control without therapy modification within 12 months among patients with baseline poor control. Potential overtreatment of these conditions was defined as intensive treatment among low-risk patients with optimal target values. RESULTS: 20% of patients with hypertension, 41% with dyslipidemia and 36% with diabetes mellitus were in control at baseline. When appropriate clinical action in response to poor control was integrated into measuring quality of care, 52 to 55% had appropriate quality of care. Over 12 months, therapy of 61% of patients with baseline poor control was modified for hypertension, 33% for dyslipidemia, and 85% for diabetes mellitus. Increases in number of drug classes (28-51%) and in drug doses (10-61%) were the most common therapy modifications. Patients with target organ damage and higher baseline values were more likely to have appropriate clinical action. We found low rates of potential overtreatment with 2% for hypertension, 3% for diabetes mellitus and 3-6% for dyslipidemia. CONCLUSIONS: In primary care, evaluating whether physicians respond appropriately to poor risk factor control, in addition to assessing proportions in control, provide a broader view of the quality of care than relying solely on measures of proportions in control. Such measures could be more clinically relevant and acceptable to physicians than simply reporting levels of control.
Resumo:
Yield and physical and chemical characteristics of 'Paluma' guava fruit were evaluated as a function of the harvest at different maturity stages, under influence of nitrogen and potassium fertilization, in Petrolina, State of Pernambuco, Brazil. Fertilizer rates were 67 kg N + 33 kg K2O, 133 kg N + 67 kg K2O, 200 kg N + 100 kg K2O and 267 kg N + 133 kg K2O per hectare. Fruits were evaluated at maturity stages 2, 3, 4 and 5, established according to peel color. Higher doses of N and K induced higher yields. Nevertheless, fertilization with 200 kg of N + 100 kg of K per hectare improved fruit quality, delaying ascorbic acid breakdown and conserving pulp firmness. Main changes took place at maturity stages 4 and 5, when the fruit should present ideal conditions for consumption, namely the increase on soluble solids and soluble sugars content.
Resumo:
OBJECTIVES: Regarding recent progress, musculoskeletal ultrasound (US) will probably soon be integrated in standard care of patient with rheumatoid arthritis (RA). However, in daily care, quality of US machines and level of experience of sonographers are varied. We conducted a study to assess reproducibility and feasibility of an US scoring for RA, including US devices of different quality and rheumatologist with various levels of expertise in US as it would be in daily care. METHODS: The Swiss Sonography in Arthritis and Rheumatism (SONAR) group has developed a semi-quantitative score using OMERACT criteria for synovitis and erosion in RA. The score was taught to 108 rheumatologists trained in US. One year after the last workshop, 19 rheumatologists participated in the study. Scans were performed on 6 US machines ranging from low to high quality, each with a different patient. Weighted kappa was calculated for each pair of readers. RESULTS: Overall, the agreement was fair to moderate. Quality of device, experience of the sonographers and practice of the score before the study improved substantially the agreement. Agreement assessed on higher quality machine, among sonographers with good experience in US increased to substantial (median kappa for B-mode and Doppler: 0.64 and 0.41 for erosion). CONCLUSIONS: This study demonstrated feasibility and reproducibility of the Swiss US SONAR score for RA. Our results confirmed importance of the quality of US machine and the training of sonographers for the implementation of US scoring in the routine daily care of RA.
Resumo:
BACKGROUND: There are limited data on the composition and smoke emissions of 'herbal' shisha products and the air quality of establishments where they are smoked. METHODS: Three studies of 'herbal' shisha were conducted: (1) samples of 'herbal' shisha products were chemically analysed; (2) 'herbal' and tobacco shisha were burned in a waterpipe smoking machine and main and sidestream smoke analysed by standard methods and (3) the air quality of six waterpipe cafes was assessed by measurement of CO, particulate and nicotine vapour content. RESULTS: We found considerable variation in heavy metal content between the three products sampled, one being particularly high in lead, chromium, nickel and arsenic. A similar pattern emerged for polycyclic aromatic hydrocarbons. Smoke emission analyses indicated that toxic byproducts produced by the combustion of 'herbal' shisha were equivalent or greater than those produced by tobacco shisha. The results of our air quality assessment demonstrated that mean PM2.5 levels and CO content were significantly higher in waterpipe establishments compared to a casino where cigarette smoking was permitted. Nicotine vapour was detected in one of the waterpipe cafes. CONCLUSIONS: 'Herbal' shisha products tested contained toxic trace metals and PAHs levels equivalent to, or in excess of, that found in cigarettes. Their mainstream and sidestream smoke emissions contained carcinogens equivalent to, or in excess of, those of tobacco products. The content of the air in the waterpipe cafes tested was potentially hazardous. These data, in aggregate, suggest that smoking 'herbal' shisha may well be dangerous to health.
Resumo:
The present study arose from the need to determine inorganic arsenic (iAs) at low levels in cereal-based food. Validated methods with a low limit of detection (LOD) are required to analyse these kinds of food. An analytical method for the determination of iAs, methylarsonic acid (MA) and dimethylarsinic acid (DMA) in cereal-based food and infant cereals is reported. The method was optimised and validated to achieve low LODs. Ion chromatography-inductively coupled plasma mass spectrometry (LC-ICPMS) was used for arsenic speciation. The main quality parameters were established. To expand the applicability of the method, different cereal products were analysed: bread, biscuits, breakfast cereals, wheat flour, corn snacks, pasta and infant cereals. The total and inorganic arsenic content of 29 cereal-based food samples ranged between 3.7-35.6 and 3.1-26.0 microg As kg-1, respectively. The present method could be considered a valuable tool for assessing inorganic arsenic contents in cereal-based foods.
Resumo:
The objective of this study was to evaluate the effects of foundation and leaf fertilization with micronutrients on fruit size and quality of pineapple cv. Vitória under the environmental conditions of the Baixo Acaraú irrigated perimeter in Northern Ceará State, Brazil, under two covers (bagana and black plastic) of the sandy soil of low fertility. The experimental design was a randomized split blocks one with four levels of soil dressing and four levels of foliar fertilization, with five replications. Micronutrient soil dressing was studied as FTE-12 at doses of 0, 60, 120 and 180 kg ha-1. The four levels of foliar fertilization were: LF0 (without fertilizer), LF 1 (15 leaf fertilization, using the amount of 1158.75 g Fe ha-1, 844.65 g Mn ha-1, 391.5 g ha-1 Zn, 322.65 g ha-1 Cu and 216 g ha-1 B), LF2 (15 leaf fertilization, using twice the quantities of level LF1) and LF3 (15 leaf fertilization, using three times the amount of level LF1). At 13 months after planting the micropropagated plantlets was carried out the floral induction treatment and five months later the fruit harvest determining the following variables: fruit weight and median diameter, soluble solids content (SS) and titratable acidity (TA). Both fruit weight and diameter increased with increasing doses of micronutrients applied to the soil and to the leaves, of plants grown both on bagana soil cover and plastic mulch. On the other hand fruit pulp quality was little affected by the treatments studied. There were a small increase of SS contents for plants grown on bagana soil cover and a small decrease of titratable acidity for those grown on plastic mulch, in both cases just in response to micronutrient foliar application.
Resumo:
BACKGROUND & AIMS: Trace elements (TE) are involved in the immune and antioxidant defences which are of particular importance during critical illness. Determining plasma TE levels is costly. The present quality control study aimed at assessing the economic impact of a computer reminded blood sampling versus a risk guided on-demand monitoring of plasma concentrations of selenium, copper, and zinc. METHODS: Retrospective analysis of 2 cohorts of patients admitted during 6 months periods in 2006 and 2009 to the ICU of a University hospital. INCLUSION CRITERIA: to receive intravenous micronutrient supplements and/or to have a TE sampling during ICU stay. The TE samplings were triggered by computerized reminder in 2006 versus guided by nutritionists in 2009. RESULTS: During the 2 periods 636 patients met the inclusion criteria out of 2406 consecutive admissions, representing 29.7% and 24.9% respectively of the periods' admissions. The 2009 patients had higher SAPS2 scores (p = 0.02) and lower BMI compared to 2006 (p = 0.007). The number of laboratory determinations was drastically reduced in 2009, particularly during the first week, despite the higher severity of the cohort, resulting in à 55% cost reduction. CONCLUSIONS: The monitoring of TE concentrations guided by a nutritionist resulted in a reduction of the sampling frequency, and targeting on the sickest high risk patients, requiring a nutritional prescription adaptation. This control leads to cost reduction compared to an automated sampling prescription.
Resumo:
This study aimed to evaluate the effect of substrate on growth, emergence, nutrition, and quality of Anacardium othonianum Rizz. (cerrado cashew tree) seedlings. The experiment was conducted in a greenhouse at the Plant Tissue Culture Laboratory on the Rio Verde campus. The following substrates were used: 1) Bioplant®, 2) Mecplant® (MP) + carbonized rice husk (CRH) (7:3), 3) fine-grained vermiculite (FGV), 4) FGV+CRH (3:1), 5) FGV+CRH (1:1), 6) FGV+CRH (1:3), and 7) sugarcane bagasse (SB) + sugarcane mill filter cake (FC) (3:2). Emerged seedlings were counted at 2-day intervals for 38 days following emergence of the first seedling. At 39, 64, and 89 days after seeding (DAS), the following variables were measured: stem length (SL), stem diameter (SD), and number of leaves (NL). Accumulated dry weight, quality indices, and leaf macro- and micronutrient levels were determined at 89 DAS. Plants grown in the FGV and FGV+CFH (1:3) substrates had shorter stem lengths than the plants grown in other substrates. Increases in seedling growth were smaller between 64 and 89 DAS compared to the initial period of the experiment. The highest leaf N concentrations were found in the SB+FC substrate treatment group; P and K concentrations were higher for the MP+CRH (7:3), SB+FC, and Bioplant® treatments; and Ca levels were higher for the SB+FC and MP+CRH (7:3) substrate treatments. The MP+CRH (7:3) substrate treatment group had the highest leaf B and Mn micronutrient concentrations, and plants from the Bioplant® substrate group had the highest leaf B micronutrient content. Mg, S, Cu, Zn, and Fe concentrations did not differ among the different substrates. The plant traits that differed most among the treatments included stem length for the FGV and FGV+CRH (1:3) substrate groups and leaf nutrient concentrations, which were higher for the SB+FC group followed by the MP+CRH and Bioplant® treatments.