922 resultados para Quadrants (Astronomical instruments)
Resumo:
Objective: Community-based care for mental disorders places considerable burden on families and carers. Measuring their experiences has become a priority, but there is no consensus on appropriate instruments. We aimed to review instruments carers consider relevant to their needs and assess evidence for their use. Method: A literature search was conducted for outcome measures used with mental health carers. Identified instruments were assessed for their relevance to the outcomes identified by carers and their psychometric properties. Results: Three hundred and ninety two published articles referring to 241 outcome measures were identified, 64 of which were eligible for review (used in three or more studies). Twenty-six instruments had good psychometric properties; they measured (i) carers' well-being, (ii) the experience of caregiving and (iii) carers' needs for professional support. Conclusion: Measures exist which have been used to assess the most salient aspects of carer outcome in mental health. All require further work to establish their psychometric properties fully.
Resumo:
Background Screening instruments for autistic-spectrum disorders have not been compared in the same sample. Aims To compare the Social Communication Questionnaire (SCQ), the Social Responsiveness Scale (SRS) and the Children's Communication Checklist (CCC). Method Screen and diagnostic assessments on 119 children between 9 and 13 years of age with special educational needs with and without autistic-spectrum disorders were weighted to estimate screen characteristics for a realistic target population. Results The SCQ performed best (area under receiver operating characteristic curve (AUC)=0.90; sensitivity. 6; specificity 0.78). The SRS had a lower AUC (0.77) with high sensitivity (0.78) and moderate specificity (0.67). The CCC had a high sensitivity but lower specificity (AUC=0.79; sensitivity 0.93; specificity 0.46). The AUC of the SRS and CCC was lower for children with IQ < 70. Behaviour problems reduced specificity for all three instruments. Conclusions The SCQ, SRS and CCC showed strong to moderate ability to identify autistic-spectrum disorder in this at-risk sample of school-age children with special educational needs.
Resumo:
The VISIR instrument for the European Southern Observatory (ESO) Very Large Telescope (VLT) is a thermal-infrared imager and spectrometer currently being developed by the French Service d'Astrophysique of CEA Saclay, and Dutch NFRA ASTRON Dwingeloo consortium. This cryogenic instrument will employ precision infrared bandpass filters in the N-( =7.5-14µm) and Q-( =16-28µm) band mid-IR atmospheric windows to study interstellar and circumstellar environments crucial for star and planetary formation theories. As the filters in these mid-IR wavelength ranges are of interest to many astronomical cryogenic instruments, a worldwide astronomical filter consortium was set up with participation from 12 differing institutes, each requiring instrument specific filter operating environments and optical metrology. This paper describes the design and fabrication methods used to manufacture these astronomical consortium filters, including the rationale for the selection of multilayer coating designs, temperature-dependant optical properties of the filter materials and FTIR spectral measurements showing the changes in passband and blocking performance on cooling to <50K. We also describe the development of a 7-14µm broadband antireflection coating deposited on Ge lenses and KRS-5 grisms for cryogenic operation at 40K
Resumo:
In order to make best use of the opportunities provided by space missions such as the Radiation Belt Storm Probes, we determine the response of complementary subionospheric radiowave propagation measurements (VLF), riometer absorption measurements (CNA), and GPS-produced total electron content (vTEC) to different energetic electron precipitation (EEP). We model the relative sensitivity and responses of these instruments to idealised monoenergetic beams of precipitating electrons, and more realistic EEP spectra chosen to represent radiation belts and substorm precipitation. In the monoenergetic beam case, we find riometers are more sensitive to the same EEP event occurring during the day than during the night, while subionospheric VLF shows the opposite relationship, and the change in vTEC is independent. In general, the subionospheric VLF measurements are much more sensitive than the other two techniques for EEP over 200 keV, responding to flux magnitudes two-three orders of magnitude smaller than detectable by a riometer. Detectable TEC changes only occur for extreme monoenergetic fluxes. For the radiation belt EEP case, clearly detectable subionospheric VLF responses are produced by daytime fluxes that are ~10 times lower than required for riometers, while nighttime fluxes can be 10,000 times lower. Riometers are likely to respond only to radiation belt fluxes during the largest EEP events and vTEC is unlikely to be significantly disturbed by radiation belt EEP. For the substorm EEP case both the riometer absorption and the subionospheric VLF technique respond significantly, as does the change in vTEC, which is likely to be detectable at ~3-4 TECu.
Resumo:
Two aircraft instruments for the measurement of total odd nitrogen (NOy) were compared side by side aboard a Learjet A35 in April 2003 during a campaign of the AFO2000 project SPURT (Spurengastransport in der Tropopausenregion). The instruments albeit employing the same measurement principle (gold converter and chemiluminescence) had different inlet configurations. The ECO-Physics instrument operated by ETH-Zürich in SPURT had the gold converter mounted outside the aircraft, whereas the instrument operated by FZ-Jülich in the European project MOZAIC III (Measurements of ozone, water vapour, carbon monoxide and nitrogen oxides aboard Airbus A340 in-service aircraft) employed a Rosemount probe with 80 cm of FEP-tubing connecting the inlet to the gold converter. The NOy concentrations during the flight ranged between 0.3 and 3 ppb. The two data sets were compared in a blind fashion and each team followed its normal operating procedures. On average, the measurements agreed within 7%, i.e. within the combined uncertainty of the two instruments. This puts an upper limit on potential losses of HNO3 in the Rosemount inlet of the MOZAIC instrument. Larger transient deviations were observed during periods after calibrations and when the aircraft entered the stratosphere. The time lag of the MOZAIC instrument observed in these instances is in accordance with the time constant of the MOZAIC inlet line determined in the laboratory for HNO3.
Resumo:
Combining SNPs into allele scores provides a more powerful instrument for MR analysis than a single SNP in isolation. Population stratification and the potential for pleiotropic effects need to be considered in MR studies on vitamin D.
Resumo:
We present the first comprehensive intercomparison of currently available satellite ozone climatologies in the upper troposphere/lower stratosphere (UTLS) (300–70 hPa) as part of the Stratosphere-troposphere Processes and their Role in Climate (SPARC) Data Initiative. The Tropospheric Emission Spectrometer (TES) instrument is the only nadir-viewing instrument in this initiative, as well as the only instrument with a focus on tropospheric composition. We apply the TES observational operator to ozone climatologies from the more highly vertically resolved limb-viewing instruments. This minimizes the impact of differences in vertical resolution among the instruments and allows identification of systematic differences in the large-scale structure and variability of UTLS ozone. We find that the climatologies from most of the limb-viewing instruments show positive differences (ranging from 5 to 75%) with respect to TES in the tropical UTLS, and comparison to a “zonal mean” ozonesonde climatology indicates that these differences likely represent a positive bias for p ≤ 100 hPa. In the extratropics, there is good agreement among the climatologies regarding the timing and magnitude of the ozone seasonal cycle (differences in the peak-to-peak amplitude of <15%) when the TES observational operator is applied, as well as very consistent midlatitude interannual variability. The discrepancies in ozone temporal variability are larger in the tropics, with differences between the data sets of up to 55% in the seasonal cycle amplitude. However, the differences among the climatologies are everywhere much smaller than the range produced by current chemistry-climate models, indicating that the multiple-instrument ensemble is useful for quantitatively evaluating these models.
Resumo:
Designing surgical instruments for robotic-assisted minimally-invasive surgery (RAMIS) is challenging due to constraints on the number and type of sensors imposed by considerations such as space or the need for sterilization. A new method for evaluating the usability of virtual teleoperated surgical instruments based on virtual sensors is presented. This method uses virtual prototyping of the surgical instrument with a dual physical interaction, which allows testing of different sensor configurations in a real environment. Moreover, the proposed approach has been applied to the evaluation of prototypes of a two-finger grasper for lump detection by remote pinching. In this example, the usability of a set of five different sensor configurations, with a different number of force sensors, is evaluated in terms of quantitative and qualitative measures in clinical experiments with 23 volunteers. As a result, the smallest number of force sensors needed in the surgical instrument that ensures the usability of the device can be determined. The details of the experimental setup are also included.
Resumo:
We establish a methodology for calculating uncertainties in sea surface temperature estimates from coefficient based satellite retrievals. The uncertainty estimates are derived independently of in-situ data. This enables validation of both the retrieved SSTs and their uncertainty estimate using in-situ data records. The total uncertainty budget is comprised of a number of components, arising from uncorrelated (eg. noise), locally systematic (eg. atmospheric), large scale systematic and sampling effects (for gridded products). The importance of distinguishing these components arises in propagating uncertainty across spatio-temporal scales. We apply the method to SST data retrieved from the Advanced Along Track Scanning Radiometer (AATSR) and validate the results for two different SST retrieval algorithms, both at a per pixel level and for gridded data. We find good agreement between our estimated uncertainties and validation data. This approach to calculating uncertainties in SST retrievals has a wider application to data from other instruments and retrieval of other geophysical variables.
Resumo:
A pilot study consisting of a parent questionnaire, four APD tests and an acceptability questionnaire were presented to normal hearing and cognitively developing children between the ages of 8-12 years. Responses to a standard and modified response format of the APD tests were obtained over two test sessions. Results indicated that the modified response formats of the four APD tests were acceptable, fairly reliable and three out of the four APD tests were valid.
Resumo:
Cosmic shear requires high precision measurement of galaxy shapes in the presence of the observational point spread function (PSF) that smears out the image. The PSF must therefore be known for each galaxy to a high accuracy. However, for several reasons, the PSF is usually wavelength dependent; therefore, the differences between the spectral energy distribution of the observed objects introduce further complexity. In this paper, we investigate the effect of the wavelength dependence of the PSF, focusing on instruments in which the PSF size is dominated by the diffraction limit of the telescope and which use broad-band filters for shape measurement. We first calculate biases on cosmological parameter estimation from cosmic shear when the stellar PSF is used uncorrected. Using realistic galaxy and star spectral energy distributions and populations and a simple three-component circular PSF, we find that the colour dependence must be taken into account for the next generation of telescopes. We then consider two different methods for removing the effect: (i) the use of stars of the same colour as the galaxies and (ii) estimation of the galaxy spectral energy distribution using multiple colours and using a telescope model for the PSF. We find that both of these methods correct the effect to levels below the tolerances required for per cent level measurements of dark energy parameters. Comparison of the two methods favours the template-fitting method because its efficiency is less dependent on galaxy redshift than the broad-band colour method and takes full advantage of deeper photometry.
Resumo:
We employ the recently installed near-infrared Multi-Conjugate Adaptive Optics demonstrator (MAD) to determine the basic properties of a newly identified, old and distant, Galactic open cluster (FSR 1415). The MAD facility remarkably approaches the diffraction limit, reaching a resolution of 0.07 arcsec (in K), that is also uniform in a field of similar to 1.8 arcmin in diameter. The MAD facility provides photometry that is 50 per cent complete at K similar to 19. This corresponds to about 2.5 mag below the cluster main-sequence turn-off. This high-quality data set allows us to derive an accurate heliocentric distance of 8.6 kpc, a metallicity close to solar and an age of similar to 2.5 Gyr. On the other hand, the deepness of the data allows us to reconstruct (completeness-corrected) mass functions (MFs) indicating a relatively massive cluster, with a flat core MF. The Very Large Telescope/MAD capabilities will therefore provide fundamental data for identifying/analysing other faint and distant open clusters in the Galaxy III and IV quadrants.