935 resultados para Power to decide process


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertation submitted in partial fulfillment of the requirements for the Degree of Master of Science in Geospatial Technologies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Breast cancer is the most common type of cancer among women all over the world. An important issue that is not commonly addressed in breast cancer imaging literature is the importance of imaging the underarm region—where up to 80% of breast cancer cells can metastasise to. The first axillary lymph nodes to receive drainage from the primary tumour in the breast are called Sentinel Node. If cancer cells are found in the Sentinel Node, there is an increased risk of metastatic breast cancer which makes this evaluation crucial to decide what follow-up exams and therapy to follow. However, non-invasive detection of cancer cells in the lymph nodes is often inconclusive, leading to the surgical removal of too many nodes which causes adverse side-effects for patients. Microwave Imaging is one of the most promising non-invasive imaging modalities for breast cancer early screening and monitoring. This novel study tests the feasibility of imaging the axilla region by means of the simulation of an Ultra-Wideband Microwave Imaging system. Simulations of such system are completed in several 2D underarm models that mimic the axilla. Initial imaging results are obtained by means of processing the simulated backscattered signals by eliminating artefacts caused by the skin and beamforming the processed signals in order to time-align all the signals recorded at each antenna. In this dissertation several image formation algorithms are implemented and compared by visual inspection of the resulting images and through a range of performance metrics, such as Signal-to-Clutter Ratio and FullWidth Half Maximum calculations. The results in this study showed that Microwave Imaging is a promising technique that might allow to identify the presence and location of metastasised cancer cells in axillary lymph nodes, enabling the non-invasive evaluation of breast cancer staging.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

RESUMO: Introdução: A obstrução da via aérea central (OVAC) refere-se a um processo patológico que conduz a limitação do fluxo de ar ao nível do espaço glótico e subglótico, traqueia e brônquios principais. O seu correcto diagnóstico e tratamento constituem um território de interesse e preocupação para os profissionais de saúde, e requerem um profundo conhecimento da sua etiologia, fisiologia, diagnóstico e opções terapêuticas dado o potencial em originar significativa morbilidade e mortalidade. A avaliação da OVAC abrange múltiplas vertentes, entre as quais se salienta o componente clínico (sinais e sintomas), a repercussão fisiopatológica (função respiratória) e o estudo imagiológico (TC do tórax e broncoscopia). A compilação destes dados associada à etiologia, constituem factores importantes para estabelecer o prognóstico, determinar a necessidade de tratamento ou delinear uma futura intervenção terapêutica. A broncoscopia é o Gold Standard de avaliação desta condição, mas desde há cerca de 40 anos a curva de débito-volume constitui uma ferramenta não invasiva de detecção de OVAC. Apesar deste método ser utilizado até os nossos dias, poucos têm sido os estudos com o objectivo de verificar a sensibilidade e especificidade da curva de débito-volume na detecção de OVAC, bem como averiguar a relação entre as alterações morfológicas e quantitativas da mesma com a localização, o tipo e o grau da obstrução. Material e Métodos: Entre 1 de Novembro de 2009 e 30 de Abril de 2010, os doentes com indicação para a realização de broncoscopia diagnóstica ou terapêutica na Unidade de Técnicas Invasivas Pneumológicas (UTIP) do Centro Hospitalar Lisboa Norte – Hospital Pulido Valente (CHLN – HPV) foram seleccionados de forma consecutiva de acordo com os critérios de inclusão e exclusão. As avaliações (broncoscopia, curva de débito-volume e avaliação da dispneia) realizaram-se com um intervalo de tempo máximo de sete dias. A broncoscopia flexível foi realizada segundo as normas da British Thoracic Society e as curvas de débito-volume segundo as normas da ATS/ERS TaskForce 2005. Para a avaliação da dispneia recorreu-se à escala de dispneia MRC (Medical Research Council). Um painel de peritos realizou a avaliação da morfologia da curva de débito-volume (sugestiva ou não de OVAC) e um elemento independente a verificação dos critérios quantitativos e morfológicos (variáveis intra e extratorácica e fixa) da curva. O estudo foi aprovado pela Comissão de Ética para a Saúde do CHLN e todos os doentes assinaram um consentimento informado de participação. Resultados: Estudaram-se 82 doentes, 36 (44%) dos quais com OVAC. A predominância foi do género masculino, em relação ao feminino. A sensibilidade e especificidade dos critérios quantitativos da curva de débito-volume na detecção de OVAC foi de 91.3% e 88.9% respectivamente. Quando se utilizaram os critérios morfológicos da curva de débito-volume os valores foram de 93.5% e 30.6%. A agregação dos critérios morfológicos e quantitativos permitiu alcançar uma sensibilidade de 95.7% e especificidade de 86.1%. Nesta amostra, o critério quantitativo com maior ocorrência foi o FEF50/FIF50≥1 (83% dos doentes com OVAC). Este mostrou relacionar-se com todas as localizações de obstrução excepto o terço médio da traqueia. Mostrou, ainda, ter uma relação forte e positiva com o grau e tipo de obstrução (intra e extraluminal). O segundo foi o FEV1/PEF≥8, presente em 36% dos casos de OVAC. Relacionou-se com as obstruções no terço inferior da traqueia e brônquio principal direito (BPD). Também apresentou relação forte e positiva com o grau de obstrução e com os tipos de obstrução anteriormente descritos. Quanto à sintomatologia foi possível associar o grau de obstrução com o de dispneia e a presença de estridor com o grau e localização da obstrução na traqueia. Conclusões: Os resultados deste estudo demonstram que os critérios quantitativos da curva de débito-volume têm elevada sensibilidade e especificidade na detecção de OVAC. O critério FEV50/FIF50≥1 tem um bom poder discriminativo na detecção dessa condição, tendo sido relacionado com a localização, o grau e o tipo de obstrução. O critério FEV1/PEF≥8, embora com menor poder discriminativo, também se relaciona com o grau, a localização e o tipo de obstrução. A morfologia da curva tem uma boa sensibilidade mas baixa especificidade na detecção de OVAC, mas a agregação entre os critérios morfológicos e quantitativos aumenta a sensibilidade e especificidade. A dispneia e o estridor foram relacionados com o grau de obstrução e o último com a localização ao nível da traqueia.-------------ABSTRACT: Introduction: Central airway obstruction (CAO) refers to a pathological process that leads to restriction of airflow at the level of the glottis and subglottis, trachea and main bronchi. It’s proper diagnosis and treatment is an area of interest and concern to health professionals, and requires a deep knowledge of its etiology, physiology, diagnosis and treatment options, concerning the potential to cause significant morbidity and mortality. The evaluation of CAO covers multiple aspects: the clinical component (signs and symptoms), the pathophysiological effect (lung function) and the imaging study (bronchoscopy and chest CT). The compilation of this data associated with the etiology, are important for establishing prognosis, determine the need for treatment or outline a future therapeutic intervention. Bronchoscopy is the gold standard for evaluating this condition, but for the last 40 years the flow-volume loop has been used as a noninvasive tool for detecting CAO. Although this method is still in use, only few studies were made in order to verify its sensitivity and specificity in detecting CAO, and investigate the relation between morphological and quantitative changes of the curve to location, type and degree of obstruction. Methods: Between 1st November 2009 and 30th April 2010, patients with indication to perform diagnostic or therapeutic bronchoscopy in Interventional Pulmonology Unit - Hospital Pulido Valente (CHLN - HPV), were selected consecutively according to the inclusion and exclusion criteria. All assessments (bronchoscopy, flow-volume loop and dyspnea) were carried out within a period of seven days. The flexible bronchoscopy was performed according to the standards of the British Thoracic Society and the flow-volume loops in accordance with the standards of the ATS / ERS Taskforce 2005. For the evaluation of dyspnea was used to MRC dyspnea scale (Medical Research Council). A panel of experts evaluated the morphology of flow-volume loop (suggestive or non-suggestive of CAO) and an independent element established the quantitative criteria and morphological (intra and extrathoracic variables and fixed) of the curve. This study was approved by the Ethics Committee for Health CHLN and all the patients signed an informed consent to participate. Results: We’ve studied 82 patients, 36 (44%) of those with CAO. The majority of the patients were males, compared to females. The sensitivity and specificity of the quantitative criteria of the flow-volume curve in detecting CAO was 91.3% and 88.9% respectively. When we used the morphological criteria of flow-volume loop these values were 93.5% and 30.6%. The combination of quantitative and morphological criteria produced values of 95.7% sensitivity and 86.1% specificity. FEF50/FIF50≥1 was the most representative quantitative criterion (83% of patients with CAO) and it was correlated with all sites of obstruction except in the middle third of the trachea. It has shown a strong and positive association with the degree and type of obstruction (intra and extraluminal). The second was the FEV1/PEF ≥ 8, present in 36% of cases of CAO. It could be correlated with the obstruction in the lower third of the trachea and right main bronchus. It also showed a strong positive relation with the degree and types of obstruction described above. Regarding symptoms, we found a link between the degree of obstruction and dyspnea. The presence of stridor was correlated with the location and the degree of obstruction in the trachea. Conclusion: The results of this study demonstrate that the quantitative criteria of the flow-volume loop have a high sensitivity and specificity in detecting CAO. The criterion FEV50/FIF50 ≥ 1 has a good discriminative power to detect this condition and was related to the location, degree and type of obstruction. The criterion FEV1/PEF ≥ 8, although with a weaker discriminative power, also relates to the degree, location and type of obstruction. The morphology of the curve has a good sensitivity but low specificity in detecting CAO although the combination between the morphological and quantitative criteria increases sensitivity and specificity. Dyspnea and stridor were related to the degree of obstruction and the last one with its location in the trachea.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In cataract surgery, the eye’s natural lens is removed because it has gone opaque and doesn’t allow clear vision any longer. To maintain the eye’s optical power, a new artificial lens must be inserted. Called Intraocular Lens (IOL), it needs to be modelled in order to have the correct refractive power to substitute the natural lens. Calculating the refractive power of this substitution lens requires precise anterior eye chamber measurements. An interferometry equipment, the AC Master from Zeiss Meditec, AG, was in use for half a year to perform these measurements. A Low Coherence Interferometry (LCI) measurement beam is aligned with the eye’s optical axis, for precise measurements of anterior eye chamber distances. The eye follows a fixation target in order to make the visual axis align with the optical axis. Performance problems occurred, however, at this step. Therefore, there was a necessity to develop a new procedure that ensures better alignment between the eye’s visual and optical axes, allowing a more user friendly and versatile procedure, and eventually automatizing the whole process. With this instrument, the alignment between the eye’s optical and visual axes is detected when Purkinje reflections I and III are overlapped, as the eye follows a fixation target. In this project, image analysis is used to detect these Purkinje reflections’ positions, eventually automatically detecting when they overlap. Automatic detection of the third Purkinje reflection of an eye following a fixation target is possible with some restrictions. Each pair of detected third Purkinje reflections is used in automatically calculating an acceptable starting position for the fixation target, required for precise measurements of anterior eye chamber distances.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Modern fully integrated transceivers architectures, require circuits with low area, low cost, low power, and high efficiency. A key block in modern transceivers is the power amplifier, which is deeply studied in this thesis. First, we study the implementation of a classical Class-A amplifier, describing the basic operation of an RF power amplifier, and analysing the influence of the real models of the reactive components in its operation. Secondly, the Class-E amplifier is deeply studied. The different types of implementations are reviewed and theoretical equations are derived and compared with simulations. There were selected four modes of operation for the Class-E amplifier, in order to perform the implementation of the output stage, and the subsequent comparison of results. This led to the selection of the mode with the best trade-off between efficiency and harmonics distortion, lower power consumption and higher output power. The optimal choice was a parallel circuit containing an inductor with a finite value. To complete the implementation of the PA in switching mode, a driver was implemented. The final block (output stage together with the driver) got 20 % total efficiency (PAE) transmitting 8 dBm output power to a 50 W load with a total harmonic distortion (THD) of 3 % and a total consumption of 28 mW. All implementations are designed using standard 130 nm CMOS technology. The operating frequency is 2.4 GHz and it was considered an 1.2 V DC power supply. The proposed circuit is intended to be used in a Bluetooth transmitter, however, it has a wider range of applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of the work presented in this thesis was the development of an innovative approach for the separation of enantiomers of secondary alcohols, combining the use of an ionic liquid (IL) - both as solvent for conducting enzymatic kinetic resolution and as acylating agent - with the use of carbon dioxide (CO2) as solvent for extraction. Menthol was selected for testing this reaction/separation approach due to the increasing demand for this substance, which is widely used in the pharmaceutical, cosmetics and food industries. With a view to using an ionic ester as acylating agent, whose conversion led to the release of ethanol, and due to the need to remove this alcohol so as to drive reaction equilibrium forward, a phase equilibrium study was conducted for the ehtanol/(±)-menthol/CO2 system, at pressures between 8 and 10 MPa and temperatures between 40 and 50 oC. It was found that CO2 is more selective towards ethanol, especially at the lowest pressure and highest temperature tested, leading to separation factors in the range 1.6-7.6. The pressure-temperature-composition data obtained were correlated with the Peng-Robinson equation of state and the Mathias-Klotz-Prausnitz mixing rule. The model fit the experimental results well, with an average absolute deviation (AAD) of 3.7 %. The resolution of racemic menthol was studied using two lipases, namely lipase from Candida rugosa (CRL) and immobilized lipase B from Candida antarctica (CALB), and two ionic acylating esters. No reaction was detected in either case. (R,S)-1-phenylethanol was used next, and it was found that with CRL low, nonselective, conversion of the alcohol took place, whereas CALB led to an enantiomeric excess (ee) of the substrate of 95%, at 30% conversion. Other acylating agents were tested for the resolution of (±)-menthol, namely vinyl esters and acid anhydrides, using several lipases and varying other parameters that affect conversion and enantioselectivity, such as substrate concentration, solvent and temperature. One such acylating agent was propionic anhydride. It was thus performed a phase equilibrium study on the propionic anhydride/CO2 system, at temperatures between 35 and 50 oC. This study revealed that, at 35 oC and pressures from 7 MPa, the system is monophasic for all compositions. The enzymatic catalysis studies carried out with propionic anhydride revealed that the extent of noncatalyzed reaction was high, with a negative effect on enantioselectivity. These studies showed also that it was possible to reduce considerably the impact of the noncatalyzed reaction relative to the reaction catalyzed by CRL by lowering temperature to 4 oC. Vinyl decanoate was shown to lead to the best results at conditions amenable to a process combining the use of supercritical CO2 as agent for post-reaction separation. The use of vinyl decanoate in a number of IL solvents, namely [bmim][PF6], [bmim][BF4], [hmim][PF6], [omim][PF6], and [bmim][Tf2N], led to an enantiomeric excess of product (eep) values of over 96%, at about 50% conversion, using CRL. In n-hexane and supercritical CO2, reaction progressed more slowly.(...)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pharmaceuticals and personal care products (PPCPs) are widely used on a daily basis. After their usage they reach the wastewater treatment plants (WWTPs). These compounds have different physico-chemical characteristics, which makes them difficult to completely remove in the WWTPs, througth conventional treatments. Currently, there is no legislation regarding PPCPs thresholds in effluent discharge. But, even at vestigial concentrations, these compounds enclose environmental risks due to, e.g., endocrine disruption potential. There is a need of alternative techniques for their removal in WWTPs. The main goal of this work was to assess the use of electrodialytic (ED) process to remove PPCPs from the effluent to be discharged. A two-compartment ED cell was used testing (i) the effluent position in the cell (anode and cathode compartment); (ii) the use of anion (AEM) and cation exchange membrane (CEM); (iii) the treatment period (6, 12 and 24 hours); (iv) effluent recirculation and current steps; (v) the feasibility of sequential treatments. Phosphorus (P) removal from effluent and energetic costs associated to the process were also evaluated. Five PPCPs were studied – caffeine (CAF), bisphenol A (BPA), 17 β-estradiol (E2), ethinyl estradiol (EE2) and oxybenzone (MBPh). The ED process showed to be effective in the removal when effluent is in the anode compartment. Oxidation is suggested to be the main removal process, which was between 88 and 96%, for all the compounds, in 6 hours. Nevertheless, the presence of intermediates and/or by-products was also observed in some cases. Effluent recirculation should have a retention time in the ED cell big enough to promote removal whereas the current steps (effluent in anode compartment) slightly increased removal efficiencies (higher than 80% for all PPCPs). The sequential set of ED treatment (effluent in anode compartment) showed to be effective during both periods with a removal percentage between 80 and 95% and 73 to 88% in the case of AEM and CEM, respectively. Again, the main removal process is strongly suggested to be oxidation in the anode compartment. However, there was an increase of BOD5 and COD, which might be explained by effluent spiking, these parameters limiting the effluent discharge. From these treatments, the use of AEM, enhanced the P removal from effluent to minimize risk of eutrophication. Energetic costs of the best set-up (6 hours) are approximately 0,8€/m3 of wastewater, a value considered low, attending to the prices of other treatment processes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação de mestrado em Direito dos Contratos e da Empresa

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação de mestrado em Ciência Política

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We survey results about exact cylindrically symmetric models of gravitational collapse in General Relativity. We focus on models which result from the matching of two spacetimes having collapsing interiors which develop trapped surfaces and vacuum exteriors containing gravitational waves. We collect some theorems from the literature which help to decide a priori about eventual spacetime matchings. We revise, in more detail, some toy models which include some of the main mathematical and physical issues that arise in this context, and compute the gravitational energy flux through the matching boundary of a particular collapsing region. Along the way, we point out several interesting open problems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia e Gestão de Sistemas de Informação

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia Mecânica

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A teoria institucional constituiu o enquadramento no qual foi suportada a pergunta geral desta investigação: como e porquê a Normalização da Contabilidade de Gestão (NCG) nos hospitais públicos portugueses surgiu e evoluiu? O objetivo geral foi compreender de forma profunda o surgimento e a mudança nas regras de NCG dos hospitais públicos portugueses no período histórico 1954-2011. Face ao enquadramento institucional que justificou uma investigação interpretativa, foi usado como método de investigação um estudo de caso explanatório. A evidência sobre o caso da NCG nos hospitais públicos portugueses foi recolhida em documentos e através de 58 entrevistas realizadas em 47 unidades de análise (nos serviços centrais de contabilidade do Ministério da Saúde e em 46 hospitais públicos, num total de 53 existentes). Quanto aos principais resultados obtidos, no período 1954-1974, as regras criadas pelo poder político para controlo dos gastos públicos e a contabilidade orçamental de base de caixa estiveram na génese dos primeiros conceitos de Contabilidade de Gestão (CG) para os serviços públicos de saúde portugueses. A transição de um regime ditatorial para um regime democrático (25 de Abril de 1974), a criação do Plano Oficial de Contabilidade (POC/77) e a implementação de um estado social com Serviço Nacional de Saúde (SNS) criaram a conjuntura crítica necessária para o surgimento de um Plano Oficial de Contabilidade para os Serviços de Saúde (POCSS/80) que incluiu regras de CG. A primeira edição do Plano de Contabilidade Analítica dos Hospitais (PCAH), aprovada em 1996, não foi uma construção de raiz, mas antes uma adaptação para os hospitais das regras de CG incluídas no POCSS/91 que havia revisto o POCSS/80. Após o início da implementação do PCAH, em 1998, ocorreram sequências de autorreforço institucionalizadoras destas normas, no período 1998-2011, por influência de pressões isomórficas coercivas que delinearam um processo de evolução incremental cujo resultado foi uma reprodução por adaptação, num contexto de dependência de recursos. Vários agentes internos e externos pressionaram, no período 2003-2011, através de sequências reativas para a desinstitucionalização do PCAH em resposta ao persistente fenómeno de loose coupling. Mas o PCAH só foi descontinuado nos hospitais com privatização da governação e rejeição dos anteriores sistemas de informação. Ao nível da extensão da teoria, este estudo de caso adotou o institucionalismo histórico na investigação em CG, quanto se sabe pela primeira vez, que se mostra útil na interpretação dos processos e dos resultados da criação e evolução de instituições de CG num determinado contexto histórico. Na condição de dependência de recursos, as sequências de autorreforço, via isomorfismo coercivo, tendem para uma institucionalização com fenómeno de loose coupling. Como resposta a este fenómeno, ocorrem sequências reativas no sentido da desinstitucionalização. Perante as pressões (políticas, funcionais, sociais e tecnológicas) desinstitucionalizadoras, o fator governação privada acelera o processo de desinstitucionalização, enquanto o fator governação pública impede ou abranda esse processo.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Doctoral Dissertation for PhD degree in Industrial and Systems Engineering

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tese de Doutoramento em Ciência e Engenharia de Polímeros e Compósitos