951 resultados para Plate Heat Exchanger
Resumo:
BTES (borehole thermal energy storage)systems exchange thermal energy by conduction with the surrounding ground through borehole materials. The spatial variability of the geological properties and the space-time variability of hydrogeological conditions affect the real power rate of heat exchangers and, consequently, the amount of energy extracted from / injected into the ground. For this reason, it is not an easy task to identify the underground thermal properties to use when designing. At the current state of technology, Thermal Response Test (TRT) is the in situ test for the characterization of ground thermal properties with the higher degree of accuracy, but it doesn’t fully solve the problem of characterizing the thermal properties of a shallow geothermal reservoir, simply because it characterizes only the neighborhood of the heat exchanger at hand and only for the test duration. Different analytical and numerical models exist for the characterization of shallow geothermal reservoir, but they are still inadequate and not exhaustive: more sophisticated models must be taken into account and a geostatistical approach is needed to tackle natural variability and estimates uncertainty. The approach adopted for reservoir characterization is the “inverse problem”, typical of oil&gas field analysis. Similarly, we create different realizations of thermal properties by direct sequential simulation and we find the best one fitting real production data (fluid temperature along time). The software used to develop heat production simulation is FEFLOW 5.4 (Finite Element subsurface FLOW system). A geostatistical reservoir model has been set up based on literature thermal properties data and spatial variability hypotheses, and a real TRT has been tested. Then we analyzed and used as well two other codes (SA-Geotherm and FV-Geotherm) which are two implementation of the same numerical model of FEFLOW (Al-Khoury model).
Resumo:
Il Test di Risposta Termica (Thermal Response Test-TRT) (Mogenson,1983) è il test esistente con il più alto grado di accuratezza per la caratterizzazione del reservoir geotermico superficiale. Il test consiste in una simulazione in situ del funzionamento di un sistema a circuito chiuso di sfruttamento dell’energia geotermica, per un periodo limitato di tempo, attraverso l’iniezione o estrazione di calore a potenza costante all’interno del geo-scambiatore (Borehole Heat Exchanger-BHE). Dall’analisi della variazione delle temperature del fluido circolante, è possibile avere una stima delle proprietà termiche medie del volume del reservoir geotermico interessato dal test. Le grandezze principali per la caratterizzazione di un serbatoio geotermico sono la conduttività termica (λ), la capacità termica volumetrica (c), la temperatura indisturbata del suolo (Tg) e la resistenza termica del pozzo (Rb); la loro determinazione è necessaria per il corretto progettazione degli geo-scambiatori. I risultati del TRT sono tuttavia sensibili alle condizioni al contorno spazio-temporali quali ad es.: variazione della temperatura del terreno, movimento d’acqua di falda, condizioni metereologiche, eventi stagionali, ecc. Questo lavoro vuole: i) introdurre uno studio sui problemi di caratterizzazione del reservoir geotermico superficiale, in particolare analizzando l’effetto che il movimento d’acqua di falda ha sui parametri termici; ii) analizzare la sensitività dei risultati del test alle variabilità dei parametri caratteristici del funzionamento delle attrezzature. Parte del lavoro della mia tesi è stata svolta in azienda per un periodo di 4 mesi presso la “Groenholland Geo Energy systems” che ha sede ad Amsterdam in Olanda. Tre diversi esperimenti sono stati realizzati sullo stesso sito (stratigrafia nota del terreno: argilla, sabbia fine e sabbia grossa) usando una sonda profonda 30 metri e diversi pozzi per l’estrazione d’acqua e per monitorare gli effetti in prossimità del geo scambiatore. I risultati degli esperimenti sono stati molto diversi tra di loro, non solo in termini di dati registrati (temperature del fluido termovettore), ma in termini dei valori dei parametri ottenuti elaborando i dati. In particolare non è sufficiente adottare il modello classico della sorgente lineare infinita (Infinite Line Source Solution- ILS) (Ingersoll and Plass, 1948), il quale descrive il trasferimento di calore per conduzione in un mezzo omogeneo indefinito a temperatura costante. Infatti, lo scambio di calore avviene anche tramite convezione causata dal movimento d’acqua di falda, non identificabile mediante gli approcci classici tipo CUSUM test (Cumulative Sum test) (Brown e altri,1975) Lo studio della tesi vuole dare un quadro di riferimento per correlare la variabilità dei risultati con la variabilità delle condizioni al contorno. L’analisi integra le metodologie classiche (ILS) con un approccio geostatistico utile a comprendere i fenomeni e fluttuazioni che caratterizzano il test. Lo studio delle principali variabili e parametri del test, quali temperatura in ingresso e uscita del fluido termovettore, portata del fluido e potenza iniettata o estratta, è stato sviluppato mediante: il variogramma temporale, ovvero la semivarianza dell’accrescimento, che esprime il tipo di autocorrelazione temporale della variabile in esame; la covarianza incrociata temporale, ovvero la covarianza fra due variabili del sistema, che ne definisce quantitativamente il grado di correlazione in funzionamento del loro sfasamento temporale. L’approccio geostatistico proposto considera la temperatura del fluido Tf come una funzione aleatoria (FA) non stazionaria nel tempo (Chiles, 1999), il cui trend è formalmente definito, ma deve essere identificato numericamente. Si considera quindi un classico modello a residuo; in cui la FA è modellizzata come la somma di un termine deterministico, la media (il valore atteso) m(t),coincidente col modello descritto dalla teoria della sorgente lineare infinità, e di un termine aleatorio, la fluttuazione, Y(t). Le variabili portata e potenza sono invece considerate delle funzioni aleatorie stazionarie nel tempo, ovvero a media costante. Da questo studio di Tesi si sono raggiunte delle conclusioni molto importanti per lo studio del TRT: Confronto tra gli esperimenti in estrazione di calore, con e senza movimento d’acqua di falda: si studia l’effetto indotto dalla falda sul TRT. E’ possibile caratterizzare quantitativamente l’incremento della conducibilità termica equivalente legata a fenomeni convettivi dovuti al movimento d’acqua di falda. Inoltre, i variogrammi sperimentali evidenziano periodicità simili nei due casi e legate al funzionamento della pompa di calore e della componentistica associata ed alla circolazione del fluido termovettore all’interno della sonda. Tuttavia, la componente advettiva ha un effetto di smorzamento sulle piccole periodicità dei variogrammi, ma di aumento dell’ampiezza delle periodicità maggiori a causa del funzionamento della pompa di calore che deve fornire maggiore energia al sistema per bilanciare le dispersioni dovute al movimento d’acqua di falda. Confronto fra estrazione ed iniezione di calore, con movimento d’acqua di falda: si studia la significatività dei risultati nei due casi. L’analisi delle variografie evidenzia significative differenze nella struttura dei variogrammi sperimentali. In particolare, nel test con iniezione di calore i variogrammi sperimentali delle temperature hanno valori sistematicamente inferiori, circostanza che assicura una migliore precisione nella stima dei parametri termici. Quindi eseguire il TRT in iniezione di calore risulta più preciso. Dall’analisi dei variogrammi sperimentali delle singole variabili quali temperatura del fluido in ingresso e uscita all’interno del geoscambiatore è stato confermato il fenomeno di smorzamento delle oscillazioni da parte del terreno. Dall’analisi delle singole variabili del test (temperature, potenza, portata) è stata confermata l’indipendenza temporale fra portate e temperature. Ciò è evidenziato dalle diverse strutture dei variogrammi diretti e dalle covarianze incrociate prossime a zero. Mediante correlogrami è stato dimostrato la possibilità di calcolare il tempo impiegato dal fluido termovettore per circolare all’interno della sonda. L’analisi geostatistica ha permesso quindi di studiare in dettaglio la sensitività dei risultati del TRT alle diverse condizioni al contorno, quelle legate al reservoir e quelle legate al funzionamento delle attrezzature
Resumo:
Die oberflächennahe Geothermie leistet im Bereich der Nutzung regenerativer Wärme einen wichtigen Beitrag zum Klima- und Umweltschutz. Um die technische Nutzung oberflächennaher Geothermie zu optimieren, ist die Kenntnis der Beschaffenheit des geologischen Untergrundes ausschlaggebend. Die vorliegende Dissertation befasst sich mit der Bestimmung verschiedener Untergrundparameter an einem Erdwärmesondenfeld. Es wurden Untersuchungen zur Bestimmung der Wärmeleitfähigkeit wie der enhanced Thermal Response Test (eTRT), sowie eine Untergrund-Temperaturüberwachung im ersten Betriebsjahr durchgeführt. Die Überwachung zeigte keine gegenseitige Beeinflussung einzelner Sonden. Ein Vergleich zwischen dem geplanten und dem tatsächlichem Wärmebedarf des ersten Betriebsjahres ergab eine Abweichung von ca. 35%. Dies zeigt, dass die Nutzungsparameter der Anlage deren Effizienz maßgeblich beeinflussen können. Der am Beispielobjekt praktisch durchgeführte eTRT wurde mittels numerischer Modellierung auf seine Reproduzierbarkeit hin überprüft. Bei einem rein konduktiven Wärmetransport im Untergrund betrug die maximale Abweichung der Messung selbst unter ungünstigen Bedingungen lediglich ca. 6% vom zu erwartenden Wert. Die Detektion von grundwasserdurchflossenen Schichten ist in den Modellen ebenfalls gut abbildbar. Problematisch bleibt die hohe Abhängigkeit des Tests von einer konstanten Wärmezufuhr. Lediglich die Bestimmung der Wärmeleitfähigkeit über das Relaxationsverhalten des Untergrundes liefert bei Wärmeeintragsschwankungen hinreichend genaue Ergebnisse. Die mathematische Nachbearbeitung von fehlerhaften Temperaturkurven bietet einen Einstiegspunkt für weiterführende Forschung.
Resumo:
Solar energy is the most abundant persistent energy resource. It is also an intermittent one available for only a fraction of each day while the demand for electric power never ceases. To produce a significant amount of power at the utility scale, electricity generated from solar energy must be dispatchable and able to be supplied in response to variations in demand. This requires energy storage that serves to decouple the intermittent solar resource from the load and enables around-the-clock power production from solar energy. Practically, solar energy storage technologies must be efficient as any energy loss results in an increase in the amount of required collection hardware, the largest cost in a solar electric power system. Storing solar energy as heat has been shown to be an efficient, scalable, and relatively low-cost approach to providing dispatchable solar electricity. Concentrating solar power systems that include thermal energy storage (TES) use mirrors to focus sunlight onto a heat exchanger where it is converted to thermal energy that is carried away by a heat transfer fluid and used to drive a conventional thermal power cycle (e.g., steam power plant), or stored for later use. Several approaches to TES have been developed and can generally be categorized as either thermophysical (wherein energy is stored in a hot fluid or solid medium or by causing a phase change that can later be reversed to release heat) or thermochemical (in which energy is stored in chemical bonds requiring two or more reversible chemical reactions).
Resumo:
A Probabilistic Safety Assessment (PSA) is being developed for a steam-methane reforming hydrogen production plant linked to a High-Temperature Gas Cooled Nuclear Reactor (HTGR). This work is based on the Japan Atomic Energy Research Institute’s (JAERI) High Temperature Test Reactor (HTTR) prototype in Japan. This study has two major objectives: calculate the risk to onsite and offsite individuals, and calculate the frequency of different types of damage to the complex. A simplified HAZOP study was performed to identify initiating events, based on existing studies. The initiating events presented here are methane pipe break, helium pipe break, and PPWC heat exchanger pipe break. Generic data was used for the fault tree analysis and the initiating event frequency. Saphire was used for the PSA analysis. The results show that the average frequency of an accident at this complex is 2.5E-06, which is divided into the various end states. The dominant sequences result in graphite oxidation which does not pose a health risk to the population. The dominant sequences that could affect the population are those that result in a methane explosion and occur 6.6E-8/year, while the other sequences are much less frequent. The health risk presents itself if there are people in the vicinity who could be affected by the explosion. This analysis also demonstrates that an accident in one of the plants has little effect on the other. This is true given the design base distance between the plants, the fact that the reactor is underground, as well as other safety characteristics of the HTGR. Sensitivity studies are being performed in order to determine where additional and improved data is needed.
Resumo:
Este proyecto trata sobre la gestión del boil-off gas, o BOG (vapor de gas natural que se produce en las instalaciones de gas natural licuado de las plantas de regasificación), generado en la planta de regasificación de Gas Natural Licuado de Cartagena, tanto en las situaciones en las que se opera por debajo del mínimo técnico, como en las cargas y descargas de buques, en las cuales se ha de gestionar una cantidad del boil-off adicional. Para recuperar el boil-off, las plantas cuentan con un relicuador (intercambiador de calor) en el que el BOG es relicuado por el GNL que se envía a los vaporizadores para ser regasificado y emitido a la red. De forma complementaria cuentan también con una antorcha/venteo donde se quema el exceso de boil-off que no puede ser tratado por el relicuador. Se procede a un análisis de la situación actual, y de cómo la baja demanda de regasificación dificulta la gestión del boil-off. Se simula el proceso de relicuación actual en distintas situaciones de operación. Ante la situación de baja demanda, ha aumentado considerablemente el número de días en los que las plantas españolas en general, y la planta de Cartagena en particular, operan por debajo del mínimo técnico, que es el nivel de producción mínimo para recuperar todo el boil-off generado en cualquier situación de operación al tiempo que mantiene en frío todas las instalaciones, y garantiza el 100% de disponibilidad inmediata del resto de los equipos en condiciones de seguridad de funcionamiento estable. Esta situación supone inconvenientes tanto operativos como medioambientales y acarrea mayores costes económicos, a los cuales da solución el presente proyecto, decidiendo qué alternativa técnica es la más adecuada y definiéndola. Abstract This project is about the management of the boil-off gas (BOG), natural vapour gas that is produced in liquefied natural gas (LNG) regasification plants. Specifically, the study is focused on the LNG regasification plant located in Cartagena, when it operates both below the technical minimum level of regasification and in the loading/unloading of LNG carriers, situations when it is needed to handle additional BOG. In order to make the most of BOG, the plants have a re-condenser (heat exchanger). Here, the BOG is re-liquefied by the LNG that is submitted to the vaporizers and delivered to the grid. The plants also have a flare/vent where the excess of BOG that cannot be treated by the re-condenser is burned. An analysis of the current situation of the demand is performed, evaluating how low markets demand for regasification difficult the BOG management. Besides, it is simulated the current re-liquefaction operating in different environments. Due to the reduction of the demand for natural gas, the periods when Spanish LNG regasification plants (and particularly the factory of Cartagena) are operating below the technical minimum level of regasification are more usual. This level is the minimum production to recover all the BOG generated in any operating situation while maintaining cold all facilities, fully guaranteeing the immediate availability from other equipment in a safely and stable operation. This situation carries both operational and environmental drawbacks, and leads to higher economic costs. This project aims to solve this problem, presenting several technical solutions and deciding which is the most appropriate.
Resumo:
Efficient high speed propulsion requires exploiting the cooling capability of the cryogenic fuel in the propulsion cycle. This paper presents the numerical model of a combined cycle engine while in air turbo-rocket configuration. Specific models of the various heat exchanger modules and the turbomachinery elements were developed to represent the physical behavior at off-design operation. The dynamic nature of the model allows the introduction of the engine control logic that limits the operation of certain subcomponents and extends the overall engine operational envelope. The specific impulse and uninstalled thrust are detailed while flying a determined trajectory between Mach 2.5 and 5 for varying throttling levels throughout the operational envelope.
Resumo:
Direct Steam Generation (DSG) in Linear Fresnel (LF) solar collectors is being consolidated as a feasible technology for Concentrating Solar Power (CSP) plants. The competitiveness of this technology relies on the following main features: water as heat transfer fluid (HTF) in Solar Field (SF), obtaining high superheated steam temperatures and pressures at turbine inlet (500ºC and 90 bar), no heat tracing required to avoid HTF freezing, no HTF degradation, no environmental impacts, any heat exchanger between SF and Balance Of Plant (BOP), and low cost installation and maintenance. Regarding to LF solar collectors, were recently developed as an alternative to Parabolic Trough Collector (PTC) technology. The main advantages of LF are: the reduced collector manufacturing cost and maintenance, linear mirrors shapes versus parabolic mirror, fixed receiver pipes (no ball joints reducing leaking for high pressures), lower susceptibility to wind damages, and light supporting structures allowing reduced driving devices. Companies as Novatec, Areva, Solar Euromed, etc., are investing in LF DSG technology and constructing different pilot plants to demonstrate the benefits and feasibility of this solution for defined locations and conditions (Puerto Errado 1 and 2 in Murcia Spain, Lidellin Newcastle Australia, Kogran Creek in South West Queensland Australia, Kimberlina in Bakersfield California USA, Llo Solar in Pyrénées France,Dhursar in India,etc). There are several critical decisions that must be taken in order to obtain a compromise and optimization between plant performance, cost, and durability. Some of these decisions go through the SF design: proper thermodynamic operational parameters, receiver material selection for high pressures, phase separators and recirculation pumps number and location, pipes distribution to reduce the amount of tubes (reducing possible leaks points and transient time, etc.), etc. Attending to these aspects, the correct design parameters selection and its correct assessment are the main target for designing DSG LF power plants. For this purpose in the recent few years some commercial software tools were developed to simulatesolar thermal power plants, the most focused on LF DSG design are Thermoflex and System Advisor Model (SAM). Once the simulation tool is selected,it is made the study of the proposed SFconfiguration that constitutes the main innovation of this work, and also a comparison with one of the most typical state-of-the-art configuration. The transient analysis must be simulated with high detail level, mainly in the BOP during start up, shut down, stand by, and partial loads are crucial, to obtain the annual plant performance. An innovative SF configurationwas proposed and analyzed to improve plant performance. Finally it was demonstrated thermal inertia and BOP regulation mode are critical points in low sun irradiation day plant behavior, impacting in annual performance depending on power plant location.
Resumo:
The supercritical Rankine power cycle offers a net improvement in plant efficiency compared with a subcritical Rankine cycle. For fossil power plants the minimum supercritical steam turbine size is about 450MW. A recent study between Sandia National Laboratories and Siemens Energy, Inc., published on March 2013, confirmed the feasibility of adapting the Siemens turbine SST-900 for supercritical steam in concentrated solar power plants, with a live steam conditions 230-260 bar and output range between 140-200 MWe. In this context, this analysis is focused on integrating a line-focus solar field with a supercritical Rankine power cycle. For this purpose two heat transfer fluids were assessed: direct steam generation and molten salt Hitec XL. To isolate solar field from high pressure supercritical water power cycle, an intermediate heat exchanger was installed between linear solar collectors and balance of plant. Due to receiver selective coating temperature limitations, turbine inlet temperature was fixed 550ºC. The design-point conditions were 550ºC and 260 bar at turbine inlet, and 165 MWe Gross power output. Plant performance was assessed at design-point in the supercritical power plant (between 43-45% net plant efficiency depending on balance of plantconfiguration), and in the subcritical plant configuration (~40% net plant efficiency). Regarding the balance of plant configuration, direct reheating was adopted as the optimum solution to avoid any intermediate heat exchanger. One direct reheating stage between high pressure turbine and intermediate pressure turbine is the common practice; however, General Electric ultrasupercritical(350 bar) fossil power plants also considered doubled-reheat applications. In this study were analyzed heat balances with single-reheat, double-reheat and even three reheating stages. In all cases were adopted the proper reheating solar field configurations to limit solar collectors pressure drops. As main conclusion, it was confirmed net plant efficiency improvements in supercritical Rankine line-focus (parabolic or linear Fresnel) solar plant configurations are mainly due to the following two reasons: higher number of feed-water preheaters (up to seven)delivering hotter water at solar field inlet, and two or even three direct reheating stages (550ºC reheating temperature) in high or intermediate pressure turbines. However, the turbine manufacturer should confirm the equipment constrains regarding reheating stages and number of steam extractions to feed-water heaters.
Resumo:
El consumo de energía es responsable de una parte importante de las emisiones a la atmósfera de CO2, que es uno de los principales causantes del efecto invernadero en nuestro planeta. El aprovechamiento de la energía solar para la producción de agua caliente, permite economizar energía y disminuir el impacto del consumo energético sobre el medio ambiente y por tanto un menor impacto medioambiental. El objetivo de la presente investigación consiste en estudiar el aprovechamiento solar para el calentamiento de los fangos en los digestores anaerobios mediante agua caliente circulando en el interior de un serpentín que rodea la superficie de dicho digestor, como apoyo a los métodos convencionales del calentamiento de fangos como la resistencia eléctrica o el intercambiador de calor mediante la energía obtenida por el gas metano producido en la digestión anaerobia. Para el estudio se utilizaron 3 digestores, dos delos cuales se calentaron con agua caliente en el interior de un serpentín (uno aislado mediante una capa de fibra de vidrio y poliuretano y otro sin aislar).El tercer digestor no tenía calentamiento exterior con el objetivo de observar su comportamiento y comparar su evolución con el resto de los digestores .La comparación de los digestores 1 y 2 nos permitió estudiar la conveniencia de proveer de aislamiento al digestor. La transferencia de calor mediante serpentín de cobre dio valores comprendidos entre 83 y 92%. La aplicación de la instalación a una depuradora a escala real para mantenimiento en el interior del digestor a T=32ºC en diferentes climas: climas templados, cálidos y fríos, consistió en el cálculo de la superficie de colectores solares y superficie de serpentín necesario para cubrir las necesidades energéticas anuales de dicho digestor, así como el estudio de rentabilidad de la instalación, dando los mejores resultados para climas cálidos con períodos de retorno de 12 años y una tasa interna de rentabilidad (TIR) del 16% obteniendo una cobertura anual del 79% de las necesidades energéticas con energía solar térmica. Energy consumption accounts for a significant part of the emissions of CO2, which is one of the main causes of the greenhouse effect on our planet. The use of solar energy for hot water production. can save energy and reduce the impact of energy consumption on the environment and therefore a reduced environmental impact. The objective of this research is to study the solar utilization for heating the sludge in anaerobic digesters by hot water circulating inside a coil surrounding the surface of digester, to support conventional heating methods sludge as the electrical resistance or heat exchanger by energy generated by the methane gas produced in the anaerobic digestion. To study 3 digesters used two models which are heated with hot water within a coil (one insulated by a layer of fiberglass and polyurethane and other uninsulated) .The third digester had no external heating in order to observe their behavior and compare their evolution with the rest of the .The comparison digesters digesters 1 and 2 allowed us to study the advisability of providing insulation to the digester. Heat transfer through copper coil gave values between 83 and 92%. The installation application to a treatment for maintaining full scale within the digester at T = 32ºC in different climates: temperate, warm and cold climates, consisted of calculating the surface area of solar collectors and coil required to cover the annual energy needs of the digester, and the study of profitability of the installation, giving the best results for hot climates with return periods of 12 years and an internal rate of return (IRR) of 16% achieving an annual coverage of 79 % of energy needs with solar energy.
Resumo:
In endotherms insects, the thermoregulatory mechanisms modulate heat transfer from the thorax to the abdomen to avoid overheating or cooling in order to obtain a prolonged flight performance. Scarabaeus sacer and S. cicatricosus, two sympatric species with the same habitat and food preferences, showed daily temporal segregation with S. cicatricosus being more active during warmer hours of the day in opposition to S. sacer who avoid it. In the case of S. sacer, their endothermy pattern suggested an adaptive capacity for thorax heat retention. In S. cicatricosus, an active ‘heat exchanger’ mechanism was suggested. However, no empirical evidence had been documented until now. Thermographic sequences recorded during flight performance showed evidence of the existence of both thermoregulatory mechanisms. In S. sacer, infrared sequences showed a possible heat insulator (passive thermal window), which prevents heat transfer from meso- and metathorax to the abdomen during flight. In S. cicatricosus, infrared sequences revealed clear and effective heat flow between the thorax and abdomen (abdominal heat transfer) that should be considered the main mechanism of thermoregulation. This was related to a subsequent increase in abdominal pumping (as a cooling mechanism) during flight. Computer microtomography scanning, anatomical dissections and internal air volume measurements showed two possible heat retention mechanisms for S. sacer; the abdominal air sacs and the development of the internal abdominal sternites that could explain the thermoregulation between thorax and abdomen. Our results suggest that interspecific interactions between sympatric species are regulated by very different mechanisms. These mechanisms create unique thermal niches for the different species, thereby preventing competition and modulating spatio-temporal distribution and the composition of dung beetle assemblages.
Resumo:
In this work, we propose a new methodology for the large scale optimization and process integration of complex chemical processes that have been simulated using modular chemical process simulators. Units with significant numerical noise or large CPU times are substituted by surrogate models based on Kriging interpolation. Using a degree of freedom analysis, some of those units can be aggregated into a single unit to reduce the complexity of the resulting model. As a result, we solve a hybrid simulation-optimization model formed by units in the original flowsheet, Kriging models, and explicit equations. We present a case study of the optimization of a sour water stripping plant in which we simultaneously consider economics, heat integration and environmental impact using the ReCiPe indicator, which incorporates the recent advances made in Life Cycle Assessment (LCA). The optimization strategy guarantees the convergence to a local optimum inside the tolerance of the numerical noise.
Resumo:
Minimal representations are known to have no redundant elements, and are therefore of great importance. Based on the notions of performance and size indices and measures for process systems, the paper proposes conditions for a process model being minimal in a set of functionally equivalent models with respect to a size norm. Generalized versions of known procedures to obtain minimal process models for a given modelling goal, model reduction based on sensitivity analysis and incremental model building are proposed and discussed. The notions and procedures are illustrated and compared on a simple example, that of a simple nonlinear fermentation process with different modelling goals and on a case study of a heat exchanger modelling. (C) 2004 Elsevier Ltd. All rights reserved.
Resumo:
A systematic goal-driven top-down modelling methodology is proposed that is capable of developing a multiscale model of a process system for given diagnostic purposes. The diagnostic goal-set and the symptoms are extracted from HAZOP analysis results, where the possible actions to be performed in a fault situation are also described. The multiscale dynamic model is realized in the form of a hierarchical coloured Petri net by using a novel substitution place-transition pair. Multiscale simulation that focuses automatically on the fault areas is used to predict the effect of the proposed preventive actions. The notions and procedures are illustrated on some simple case studies including a heat exchanger network and a more complex wet granulation process.
Resumo:
A novel apparatus, high-pressure/high-temperature nickel flow loop, was constructed to study the effect of the flow on the rate of erosion-corrosion of mild steel in hot caustic. It has been successfully used to measure the corrosion rate of 1020 steel in 2.75 M NaOH solution at a temperature of 160 degrees C and velocities of 0.32 and 2.5 m/s. In situ electrochemical methods were used to measure the corrosion rate such as the potentiodynamic sweep, the polarization resistance method, and electrochemical impedance spectroscopy (EIS). Also used were the weight-loss method and scanning electron microscopy (SEM). Eight electrodes/coupons were used to monitor the metal loss rate, four were placed at the low velocity section, while the other four were placed in the high velocity section. The first three coupons in each section were placed within the disturbed flow region, while the fourth was placed in a fully developed flow region. The corrosion rate of the coupons in the high velocity section was generally higher than that of the coupons in the low velocity section. One coupon in the disturbed flow region had a significantly higher corrosion rate than the others. (c) 2005 Elsevier Ltd. All rights reserved.