580 resultados para Placido disks
Resumo:
The one-fluid magnetohydrodynamic (MHD) theory of magnetorotational instability (MRI) in an ideal plasma is presented. The theory predicts the possibility of MRI for arbitrary 0, where 0 is the ratio of the plasma pressure to the magnetic field pressure. The kinetic theory of MRI in a collisionless plasma is developed. It is demonstrated that as in the ideal MHD, MRI can occur in such a plasma for arbitrary P. The mechanism of MRI is discussed; it is shown that the instability appears because of a perturbed parallel electric field. The electrodynamic description of MRI is formulated under the assumption that the dispersion relation is expressed in terms of the permittivity tensor; general properties of this tensor are analyzed. It is shown to be separated into the nonrotational and rotational parts. With this in mind, the first step for incorporation of MRI into the general theory of plasma instabilities is taken. The rotation effects on Alfven waves are considered.
Resumo:
The purpose of this study was to evaluate the effectiveness of different light-curing units on the bond strength (push-out) of glass fiber posts in the different thirds of the root (cervical, middle and apical) with different adhesive luting resin systems (dual-cure total-etch; dual-cured and self-etch bonding system; and dual-cure self-adhesive cements), Disks of the samples (n = 144) were used, with approximately 1 mm of thickness of 48 bovine roots restored with glass fiber posts, that were luted with resin cements photo-activated by halogen LCU (QTH, Optilux 501) and blue LED (Ultraled), with power densities of 600 and 550 mW/cm(2), respectively. A universal testing machine (MTS 810 Material Test System) was used with a 1 mm diameter steel rod at cross-head speed of 0.5 mm/min until post extrusion, with load cell of 50 kg, for evaluation of the push-out strength in the different thirds of each sample. The push-out strength values in kgf were converted to MPa and analyzed through Analysis of Variance and Tukey`s test, at significance level of 5%. The results showed that there were no statistical differences between the QTH and LED LCUs. The self-adhesive resin cement had lower values of retention. The total-etch and self-adhesive system resin cements seem to be a possible alternative for glass fiber posts cementation into the radicular canal and the LED LCU can be applied as an alternative to halogen light on photo-activation of dual-cured resin cements.
Resumo:
Titanium alloys, alloys, especially beta-type alloys containing beta-stabilizing elements, constitute a highly versatile category of metallic materials that have been under constant development for application in orthopedics and dentistry. This type of alloy generally presents a high mechanical strength-to-weight ratio, excellent corrosion resistance and low elastic modulus. The purpose of this study is to evaluate the cytotoxicity and adhesion of fibroblast cells on titanium alloy substrates containing Nb, Ta, Zr, Cu, Sn and Mo alloying elements. Cells cultured on polystyrene were used as controls. In vitro results with Vero cells demonstrated that the tested materials, except Cu-based alloy, presented high viability in short-term testing. Adhesion of cells cultured on disks showed no differences between the materials and reference except for the Ti-Cu alloy, which showed reduced adhesion attributed to poor metabolic activity. Titanium alloys with the addition of Nb, Ta, Zr, Sn and Mo elements show a promising potential for biomedical applications. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
A resistência aos antibióticos dos patógenos mais comuns do trato respiratório está aumentando mundialmente. Recentemente, Streptococcus pneumoniae resistente à penicilina tem sido isolado em diversos países, e a freqüência dessas cepas tem elevado de modo alarmante. O aumento da resistência, com conseqüentes implicações terapêuticas, tem levado a uma reavaliação do uso dos antibióticos ß-lactâmicos para o tratamento de infecções pneumocócicas. No presente trabalho, um total de 107 amostras de Streptococcus pneumoniae, obtidas de materiais provenientes de pacientes adultos ambulatoriais e hospitalizados, em dois centros médicos de duas cidades do Rio Grande do Sul (Porto Alegre e Caxias do Sul), os quais apresentavam quadro clínico-radiológico de infecção pulmonar, foram analisadas com o objetivo de estudar-se a resistência do germe à penicilina. As amostras constituídas de escarro (80,4%), lavado brônquico (13,5%) e aspirado traqueal (6,6%) foram coletadas no período compreendido entre Julho de 1998 e Julho de 1999. O material foi semeado em meio de Agar sangue e as colônias suspeitas de Streptococcus pneumoniae foram transferidas para meio de Mueller-Hinton para teste de optoquina e de sensibilidade à penicilina com discos de oxacilina. Um halo de inibição da oxacilina menor do que 20 mm indicava a realização de teste para determinação da concentração inibitória mínima (MIC) com E-test. Um total de nove cepas foi identificado como tendo resistência intermediária à penicilina (MIC 0,1-1,0μg/ml) e nenhuma cepa resistente (resistência elevada: MIC > 2,0 μg/ml) foi identificada. Uma monitorização local das cepas quanto à resistência antimicrobiana é de grande importância para os clínicos no manejo de infecções pneumocócicas.
Resumo:
Commercially pure Titanium (cp Ti) is a material largely used in orthopedic and dental implants due to its biocompatibility properties. Changes in the surface of cp Ti can determine the functional response of the cells such as facilitating implant fixation and stabilization, and increased roughness of the surface has been shown to improve adhesion and cellular proliferation. Various surface modification methods have been developed to increase roughness, such as mechanical, chemical, electrochemical and plasma treatment. An argon plasma treatment generates a surface that has good mechanical proprieties without chemical composition modification. Besides the topography, biological responses to the implant contribute significantly to its success. Oxidative stress induced by the biomaterials is considered one of the major causes of implant failure. For this reason the oxidative potential of titanium surfaces subjected to plasma treatment was evaluated on this work. CHO-k1 cells were cultivated on smooth or roughed Ti disks, and after three days, the redox balance was investigated measuring reactive oxygen species (ROS) generation, total antioxidant capacity and biomarkers of ROS attack. The results showed cells grown on titanium surfaces are subjected to intracellular oxidative stress due to hydrogen peroxide generation. Titanium discs subjected to the plasma treatment induced less oxidative stress than the untreated ones, which resulted in improved cellular ability. Our data suggest that plasma treated titanium may be a more biocompatible biomaterial.
Influência das espécies ativas na absorção de intersticiais durante a carbonitretação a plasma do TI
Resumo:
Physical-chemical properties of Ti are sensible to the presence of interstitial elements. In the case of thermochemical treatments plasma assisted, the influence of different active species is not still understood. In order to contribute for such knowledge, this work purposes a study of the role played by the active species atmosphere into the Ar N2 CH4 carbonitriding plasma. It was carried out a plasma diagnostic by OES (Optical Emission Spectroscopy) in the z Ar y N2 x CH4 plasma mixture, in which z, y and x indexes represent gas flow variable from 0 to 4 sccm (cm3/min). The diagnostic presents abrupt variations of emission intensities associated to the species in determined conditions. Therefore, they were selected in order to carry out the chemical treatment and then to investigate their influences. Commercial pure Ti disks were submitted to plasma carbonitriding process using pre-established conditions from the OES measurements while some parameters such as pressure and temperature were maintained constant. The concentration profiles of interstitial elements (C and N atoms) were determined by Resonant Nuclear Reaction Analysis (NRA) resulting in a depth profile plots. The reactions used were 15N(ρ,αγ)12C and 12C(α,α)12C. GIXRD (Grazing Incidence X-Ray Diffraction) analysis was used in order to identify the presence of phases on the surface. Micro-Raman spectroscopy was used in order to qualitatively study the carbon into the TiCxN1 structure. It has been verified which the density species effectively influences more the diffusion of particles into the Ti lattice and characteristics of the layer formed than the gas concentration. High intensity of N2 + (391,4 nm) and CH (387,1 nm) species promotes more diffusion of C and N. It was observed that Hα (656,3 nm) species acts like a catalyzer allowing a deeper diffusion of nitrogen and carbon into the titanium lattice.
Resumo:
The titanium and titanium alloys are widely used as biomaterial in biomedical device and so research have been developed aiming to improve and/or better to understand interaction biomaterial/biological environment. The process for manufacturing of this titanium implants usually involves a series of thermal and mechanical processes which have consequence on the final product. The heat treatments are usually used to obtain different properties for each application. In order to understand the influence of these treatments on the biological response of the surface, it was done, in this work, different heat treatments in titanium and analyzed their influence on the morphology, adhesion and proliferation of the pre-osteoblastic cells (MC3T3-E1). For such heat-treated titanium disks were characterized by optical microscopy, contact angle, surface energy, roughness, microhardness, X-ray diffraction and scanning through the techniques (BSE, EDS and EBSD). For the analysis of biological response were tested by MTT proliferation, adhesion by crystal violet and β1 integrin expression by flow cytometry. It was found that the presence of a microstructure very orderly, defined by a chemical attack, cells tend to stretch in the same direction of orientation of the material microstructure. When this order does not happen, the most important factor influencing cell proliferation is the residual stress, indicated by the hardness of the material. This way the disks with the highest level state of residual stress also showed increased cell proliferation
Resumo:
O Eucalyptus grandis é uma das espécies mais cultivadas no Brasil devido à sua produtividade e qualidade da madeira. Avaliaram-se o efeito da aplicação de lodo de esgoto tratado (0 a 40 t ha-1 base seca) e uma dose de adubo mineral nos atributos físicos e químicos da madeira de Eucalyptus grandis de árvores com cinco anos de idade, no Município de Itatinga, São Paulo, Brasil. O tipo de solo foi caracterizado como Latossolo Vermelho-Amarelo Distrófico (argila = 120 g kg-1 na camada de 0-20 cm) e o clima, como mesotérmico úmido (Cwa), segundo a classificação de Köeppen. O delineamento experimental foi o de blocos ao acaso, com seis tratamentos e quatro repetições. O diâmetro à altura do peito (DAP), a altura das árvores e o volume de madeira foram obtidos em todas as parcelas de oito árvores com DAP na classe de maior freqüência. As caracterizações físicas e químicas da madeira foram realizadas de acordo com as normas da ABTCP, TAPPI e ABNT. O lodo de esgoto diminuiu a densidade básica da madeira, mas não afetou os teores de celulose, lignina, extrativos e o poder calorífico da madeira. O decréscimo de densidade da madeira pela adubação com lodo de esgoto foi compensado pela maior produtividade de madeira.
Resumo:
The science of Dentistry wishes obtains the ideal solution for the dental plaque chemical control. This research evaluated antimicrobial action capacity in calcium hydroxide and tergentol various solutions starting for the CHD 20, a root canals irrigating solution with a reason of 80% calcium hydroxide saturated solution and 20% tergentol detergent with the aim of evaluate this drug mouth rinse indication with prevention or combat objective for dental caries and periodontal diseases. Antibiogram disks and biofilm tests were accomplished for the microorganisms: Streptococcus mutans, Streptococcus sanguis, Streptococcus sobrinus and Lactobacillus casei. Different reasons of detergent for the calcium hydroxide saturated solution, tergentol and distillated water solution, 0,12% clorhexydine digluconate solution was positive control and distillated water was negative control. The results showed better performance of clorhexydine in relation to calcium hydroxide directing to not accept this (CHD20) as mouth rinse solution
Resumo:
Recent years have seen a significant growth in surface modifications in titanium implants, resulting in shorter healing times in regions with low bone density. Among the different techniques, subtraction by chemical agents to increase oxidation has been applied for surface treatment of dental implants. However, this technique is generally unable to remove undesirable oxides, formed spontaneously during machining of titanium parts, raising costs due to additional decontamination stages. In order to solve this problem, the present study used plasma as an energy source to both remove these oxides and oxidize the titanium surface. In this respect, Ti disks were treated by hollow cathode discharge, using a variable DC power supply and vacuum system. Samples were previously submitted to a cleaning process using an atmosphere of Ar, H2 and a mixture of both, for 20 and 60 min. The most efficient cleaning condition was used for oxidation in a mixture of argon (60%) and oxygen (40%) until reaching a pressure of 2.2 mbar for 60 min at 500°C. Surfaces were characterized by scanning electron microscopy (SEM), X-ray diffraction (XRD), atomic force microscopy (AFM), adhesion and cell proliferation. SEM showed less cell spreading and a larger number of projections orfilopodia in the treated samples compared to the control sample. AFM revealed surface defects in the treated samples, with varied geometry between peaks and valleys. Biological assays showed no significant difference in cell adhesion between treated surfaces and the control. With respect to cell proliferation, the treated surface exhibited improved performance when compared to the control sample. We concluded that the process was efficient in removing primary oxides as well as in oxidizing titanium surfaces
Resumo:
This laboratory study involves the participation of a group with professionals from different areas that had contributed to the construction of a multidisciplinary knowledge, about biological response of titanium surfaces modified through thermochemical treatment by plasma. Thus, the crystalline phase was previously characterized in relation to the topography, roughness, molhability and nitrogen concentration in the samples surface. It s indispensable that materials implanted can influence in a good cellular response as well as promotes a bacteria action. Surfaces modified by plasma were exposed to different cultures such as: cellular (human osteoblastic) and bacteria (Staphylococcus epidermidis ATCC35984 and Pseudomonas aeruginosa ATCC 27853) in order to evaluate the biological response. It was evaluated the adhesion, proliferation, morphology and cellular preference of human ostheoblastic cells (HOST), as well as the formation of a biofilm and bacteria proliferation. It was still analyzed the bacteria selectivity ability in relation to the surfaces. The software Image Pro Plus was used to the counting of cells and bacteria adhered to the surface of disks. The results were submitted to the variance analysis (ANOVA), and then, by the Kruskal-Wallis test, using GraphPad Instat ® software, version 3.5 to Windows. The nitrided samples in spite of show a higher roughness and molhability showed a smaller bacteria growing and higher cellular proliferation, when compared to non treated samples, indicating that the treated material present a high efficiency to biomedical implants
Resumo:
Studies on packaging accessibility are still incipient in Brazil. Many of these packagings can represent a challenge to users, whether due to non-informative labels, tricky tabs or seals, or even those that need strength to open. This paper brings a simple test to determine the necessary torque force to open PET bottles, and to predict the amount of users that could not open it. The findings suggest that a considerable amount of users could not open it or would have some difficulties to exert the necessary force.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)