990 resultados para Pb-210-method
Resumo:
Objective: To evaluate the biosecurity measures adopted in dental prosthesis laboratories of the city of João Pessoa, PB, Brazil with respect to prosthetic works sent by dentists. Method: Twenty-five dental prosthesis technicians (DPT) of the city of João Pessoa, PB, filled out a questionnaire referring to their knowledge of the biosecurity principles, disinfection of impressions and other prosthetic items, and the use of individual protection equipment (IPE). Results: Although 92% of the interviewees believed in the possible occurrence of cross-infection between dental prosthesis laboratories and dental offices, 64% declared that the prosthetic works received in their laboratories do not undergo any disinfection procedure. It was also observed that, for disinfection of impressions and stone casts, the chemical substances are not used as recommended by the manufacturers or are innocuous to microorganisms. Regarding the use of IPE, 60% of the DPT used mask, but only 4% used gowns. With respect to the measures taken regarding the impressions received from dental offices, 56% of the interviewees only wash them in running tap water, and 56% of the stone casts that arrive at the laboratory are not disinfected in any way. Conclusion: There is a need for more motivation and instructions to DPT regarding the prevention of cross-contamination during sending and receiving of prosthetic works between dental prosthesis laboratories and dental offices because the DPT evaluated in this study were found negligent with respect to disinfection procedures.
Resumo:
Structural, microstructural and ferroelectric properties of Pb0.90Ca0.10TiO3 (PCT10) thin films deposited using La0.50Sr0.50CoO3 (LSCO) thin films which serve only as a buffer layer were compared with properties of the thin films grown using a platinum-coated silicon substrate. LSCO and PCT10 thin films were grown using the chemical solution deposition method and heat-treated in an oxygen atmosphere at 700 °C and 650 °C in a tube oven, respectively. X-ray diffraction (XRD) and Raman spectroscopy results showed that PCT10 thin films deposited directly on a platinum-coated silicon substrate exhibit a strong tetragonal character while thin films with the LSCO buffer layer displayed a smaller tetragonal character. Surface morphology observations by atomic force microscopy (AFM) revealed that PCT10 thin films with a LSCO buffer layer had a smoother surface and smaller grain size compared with thin films grown on a platinum-coated silicon substrate. Additionally, the capacitance versus voltage curves and hysteresis loop measurement indicated that the degree of polarization decreased for PCT10 thin films on a LSCO buffer layer compared with PCT10 thin films deposited directly on a platinum-coated silicon substrate. This phenomenon can be described as the smaller shift off-center of Ti atoms along the c-direction 〈001〉 inside the TiO6 octahedron unit due to the reduction of lattice parameters. Remnant polarization (P r ) values are about 30 μC/cm2 and 12 μC/cm2 for PCT10/Pt and PCT10/LSCO thin films, respectively. Results showed that the LSCO buffer layer strongly influenced the structural, microstructural and ferroelectric properties of PCT10 thin films. © 2013 Elsevier Ltd and Techna Group S.r.l.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Química - IQ
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Agronomia (Ciência do Solo) - FCAV
Resumo:
ABSTRACT: Analytical procedures for U-Pb isotope dilution analyses at the Pará-Iso isotope geology laboratory of the Federal University of Pará (UFPA) are described in detail. The procedures are applied to zircon, titanite, rutile, apatite, columbite-tantalite and whole rock. Reagent preparation and chemical processing are done in clean-room conditions. Samples are dissolved using Teflon™ microcapsules in steel jacket Teflon™ Parr Instrument™ bomb or Teflon™ screw cap containers. U and Pb are separated using anion exchange AG 1x8 resin columns. Typical blanks for mineral sample amounts of 0.01 to 1.0 mg are less than 1 pg U and 20-30 pg Pb. Isotope analysis of the U and Pb from the same filament are carried out using a Finnigan MAT 262 mass-spectrometer in static and dynamic modes. The current analytical level is demonstrated on analyses of international standard zircon 91500 with three different 235U-205Pb and 235U-208Pb isotope tracers and whole rock standards. Results of analyses of two zircon samples are also presented.
Resumo:
O Nordeste do Brasil, em particular a região semi-árida do Estado da Paraíba, é muito castigada pelos períodos de grandes estiagens e escassez de recursos hídricos. A água de superfície não supre a demanda da região, portanto, a busca de água subterrânea e sua exploração é uma constante nos programas dos Governos Federal e Estadual. Nesta região, ocorrem geralmente apenas aquíferos aluviais rasos e aquíferos nas fraturas do embasamento cristalino. Tradicionalmente, as fraturas no cristalino são prospectados através de estudos aerofotogramétricos e geoestruturais, com média de 30% de furos secos. O dimensionamento dos aquíferos aluviais é feito através de perfurações sistemática do subsolo, que é uma metodologia muito demorosa e cara. O objetivo deste trabalho é mostrar que o emprego de métodos geofísicos, especialmente os métodos geoelétricos, são eficazes e econômicos para localizar e avaliar áreas promissoras de água subterrânea, tanto nos aquíferos aluviais como nos cristalinos. Neste trabalho, foram aplicados o convencional método da eletroresistividade e o método eletromagnético, ainda pouco usado na prospecção de água subterrânea, em três áreas selecionadas na região semi-árida de Patos - Pb, sendo duas representantes dos aquíferos aluviais e uma representante dos aquíferos cristalinos. Nos aquíferos aluviais, foi determinada a profundidade até o embasamento cristalino através de sondagens elétricas verticais (SEVs), e os respectivos limites laterais foram mapeados com perfilagens de eletroresistividade. Os resultados das SEVs são coerentes com as profundidades obtidas pelas sondagens mecânicas de confirmação mostrando, assim, a aplicabilidade desta metodologia na pesquisa deste tipo de aquífero. No aquífero cristalino, inicialmente determinou-se a orientação geral das zonas fraturadas do embasamento cristalino pela técnica modificada da sondagem elétrica vertical (SEV Radial) e, em seguida, a localização exata em planta das mesmas foram determinadas com perfilagens de eletroresistividade e eletromagnéticas no sistema horizontal coplanar nas frequências 880 Hz e 2640 Hz. Os resultados dos dois métodos utilizados foram satisfatórios, porém, a perfilagem eletromagnética é mais rápida, necessita de menos mão de obra, reduzindo assim os custos de prospecção de água subterrânea no embasamento cristalino.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Química - IQ
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)