954 resultados para Partial oxalate method
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A lectin from Cymbosema roseum seeds (CRL) was purified, characterized and crystallized. The best crystals grew in a month and were obtained by the vapour-diffusion method using a precipitant solution consisting of 0.1 M Tris-HCl pH 7.8, 8% (w/v) PEG 3350 and 0.2 M proline at a constant temperature of 293 K. A data set was collected to 1.77 angstrom resolution at a synchrotron-radiation source. CRL crystals are orthorhombic, belonging to space group P2(1)2(1)2(1). Crystallographic refinement and full amino-acid sequence determination are in progress.
Multivariate quality control studies applied to Ca(II) and Mg(II) determination by a portable method
Resumo:
A portable or field test method for simultaneous spectrophotometric determination of calcium and magnesium in water using multivariate partial least squares (PLS) calibration methods is proposed. The method is based on the reaction between the analytes and methylthymol blue at pH 11. The spectral information was used as the X-block, and the Ca(II) and Mg(II) concentrations obtained by a reference technique (ICP-AES) were used as the Y-block. Two series of analyses were performed, with a month's difference between them. The first series was used as the calibration set and the second one as the validation set. Multivariate statistical process control (MSPC) techniques, based on statistics from principal component models, were used to study the features and evolution with time of the spectral signals. Signal standardization was used to correct the deviations between series. Method validation was performed by comparing the predictions of the PLS model with the reference Ca(II) and Mg(II) concentrations determined by ICP-AES using the joint interval test for the slope and intercept of the regression line with errors in both axes. (C) 1998 John Wiley & Sons, Ltd.
Resumo:
A method is presented in which light-polymerized composite material is used to obtain retention for a removable partial denture when usable natural tooth undercuts are unavailable. The desired contour is waxed on a diagnostic cast with the use of a surveyor, captured in a light-polymerizing temporary restorative material, and reproduced in composite resin on the abutment teeth.
Resumo:
The quantitative structure-activity relationship of a set of 19 flavonoid compounds presenting antioxidant activity was studied by means of PLS (Partial Least Squares) regression. The optimization of the structures and calculation of electronic properties were done by using the semiempirical method AMI. A reliable model (r(2) = 0.806 and q(2) = 0.730) was obtained and from this model it was possible to consider some aspects of the structure of the flavonoid compounds studied that are related with their free radical scavenging ability. The quality of the PLS model obtained in this work indicates that it can be used in order to design new flavonoid compounds that present ability to scavenge free radicals.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A new methodology for soluble oxalic acid determination in grass samples was developed using a two enzyme reactor in an FIA system. The reactor consisted of 3 U of oxalate oxidase and 100 U of peroxidase immobilized on Sorghum vulgare seeds activated with glutaraldehyde. The carbon dioxide was monitored spectrophotometrically, after reacting with an acid-base indicator (Bromocresol Purple) after it permeated through a PTFE membrane. A linear response range was observed between 0.25 and 1.00mmol l-1 of oxalic acid; the data was fit by the equation A=-0.8(±1.5)+ 57.2(±2.5)[oxalate], with a correlation coefficient of 0.9971 and a relative standard deviation of 2% for n=5. The variance for a 0.25 mmol l-1 oxalic acid standard solution was lower than 4% for 11 measurements. The FIA system allows analysis of 20 samples per hour without prior treatment. The proposed method showed a good correlation with that of the Sigma Kit.
Resumo:
A flow-injection (FI) method was developed for the determination of oxalate in urine. It was based on the use of oxalate oxidase (E.C. 1.2.3.4) immobilized on ground seeds of the BR-303 Sorghum vulgare variety. A reactor was filled with this activated material, and the samples (200 μL) containing oxalate were passed through it, carried by a deionized water flow. The carbon dioxide produced by the enzyme reaction permeated through a microporous PTFE membrane, and was received in a water acceptor stream, promoting conductivity changes proportional to the oxalate concentration in the sample. The results obtained showed a useful linear range from 0.05 to 0.50 mmol dm-3. The proposed method, when compared with the Sigma enzymatic procedure, showed good correlation (Y = 0.006(±0.016) + 0.98(±0.019)X; r = 0.9995, Y = conductivity in μS, and X = concentration in mmol dm-3), selectivity, and sensitivity. The new immobilization approach promotes greater stability, allowing oxalate determination for 6 months. About 13 determinations can be performed per hour. The precision of the proposed method is about ± 3.2 % (r.s.d).
Resumo:
We update the indirect bounds on anomalous triple gauge couplings coming from the non-universal one-loop contributions to the Z → bb width. These bounds, which are independent of the Higgs boson mass, are in agreement with the standard model predictions for the gauge boson self-couplings since the present value of R(b) agrees fairly well with the theoretical estimates. Moreover, these indirect constraints on Δg(Z)/1 and g(Z)/5 are most stringent than the present direct bounds on these quantities, while the indirect limit on λ(Z) is weaker than the available experimental data.
Resumo:
The soft stadium is defined by a monomial potential with exponent α as a parameter, such that α → ∞ corresponds to the billiard. The practical use of the quantum section method depends only on the partial separability of the system on both sides of the section, which holds for all α's. In particular, for α = 1.0, the system becomes globally separable, allowing for a general test of the method. For various values of the parameter, we also tested the use of the asymptotic WKB-type approximation in the construction of Green's functions and asymptotic overlap integrals to obtain higher energy eigenvalues. We show these approximations to be reliable. © 2000 Elsevier Science B.V. All rights reserved.
Resumo:
The effects of propofol on intraocular pressure (IOP) and end tidal CO2 (ETCO2) were studied because an elevation in the latter may alter IOP. Twenty dogs were divided into two groups (G1 and G2). G1 dogs were induced with 10 mg/kg (IV) of propofol followed by a 0.4 mg/kg/min continuous infusion of the same agent diluted in a 0.2% dextrose solution for 1 h. G(CAPS) 2 dogs served as the control group, where only dextrose solution was administered, under the same time intervals as in G1. Applanation tonometry (Tono-Pen) was used to determine IOP and ETCO2 as a method to determine partial CO2 pressure. Measurements were taken every 15 min for 1 h, with M1 occurring immediately before IV administration. IOP and ETCO2 were not statistically significant in either groups. Based on the results, it may be concluded that propofol does not alter IOP and ETCO2.
Resumo:
A study of concentrated attention patterns in epileptic patients was conducted with the objectives: characterization of the patients' epileptic condition; assessment of the concentrated attention levels in epileptic and nonepileptic individuals; comparison of the attention levels of the two groups. An evaluation was performed of 50 adult outpatients with complex partial seizures and 20 non-epileptic individuals (comparative group) at the Neuroepilepsy Ambulatory Unit, State University of Campinas SP, Brazil. Method: characterization of seizure types, frequency and duration; concentrated attention assessment (Concentrated Attention Test - Toulouse-Piéron); comparison of the epileptic with non-epileptic individuals. Results: A statistically significant difference was observed between the groups with regard to Correct Response, Wrong Response and No Response. A difference was observed in relation to Time, but it was statistically insignificant. The epileptic patients presented inferior cognitive performance in relation to concentrated attention when compared with the non-epileptic individuals, findings compatible with the clinical complaints.
Resumo:
Objective: To compare the performance of patients with complex partial epilepsy with the normal controls in the subtests of an instrument used to assess intelligence function. Method: Fifty epileptic patients, whose ages ranged from 19 to 49 years and 20 normal controls without any neuropsychiatric disorders. The Wechsler-Bellevue adult intelligence test was applied in groups, epileptic patients and control subjects. This test is composed of several subtests that assess specific cognitive functions. A statistical analysis was performed using non-parametric tests. Results: All the Wechsler-Bellevue subtests revealed that the intelligence functions of the patients were significantly inferior to that of the controls (p<0.05). This performance was supported by the patient's complaints in relation to their cognitive performance. Conclusion: Patients with complex partial epilepsy presented poorer results in the intelligence test when compared with individuals without neuropsychiatric disorders.