275 resultados para PCBs
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The goal of this work was to establish comparisons among environmental degradation in different areas from Southern Spain (Gulf of Cadiz) and Brazil (Santos and Sao Vicente estuary), by using principal component analyses (PCA) to integrate sediment toxicity (amphipods mortality) and chemical-physical data (Zn, Cd, Pb; Cu, Ni, Co, V, PCBs, PAHs concentrations, OC and fines contents). The results of PCA extraction of Spanish data showed that Bay of Cadiz, CA-1 did not present contamination or degradation; CA-2 exhibited contamination by PCBs, however it was not related to the amphipods mortality. Ria of Huelva was the most impacted site, showing contamination caused principally by hydrocarbons, in HV-1 and HV-2, but heavy metals were also important contaminants at HV-1, HV-2 and HV-3. Algeciras Bay was considered as not degraded in GR-3 and -4, but in GR-3' high contamination by PAHs was found. In the Brazilian area, the most degraded sediments were found in the stations situated at the inner parts of the estuary (SSV-2, SSV-3, and SSV-4), followed by SSV-6, which is close to the Submarine Sewage Outfall of Santos - SSOS. Sediments from SSV-1 and SSV-5 did not present chemical contamination, organic contamination or significant amphipod mortality. The results, of this investigation showed that both countries present environmental degradation related to PAHs: in Spain, at Ria of Huelva and Gudarranque river's estuary areas; and in Brasil, in the internal portion of the Santos and Sao Vicente estuary. The same situation is found for heavy metals, since all of the identified metals are related to toxicity in the studied areas, with few exceptions (V for both Brazil and Spain, and Cd and Co for Brazilian areas). The contamination by PCBs is more serious for Santos and Sao Vicente estuary than for the investigated areas in Gulf of Cadiz, where such compound did not relate to the toxicity. (c) 2006 Elsevier Ltd. All rights reserved.
Resumo:
A simple and efficient method for the simultaneous gas chromatographic determination of ten organochlorine pesticides (alpha-HCH, beta-HCH, gamma-HCH, p,p'-DDT, o,p'-DDT, p,p'-DDD, p,p'-DDE, aldrin, endrin, and dieldrin) and six congeners of PCBs (PCB 28, 52, 118, 138, 153, and 180) in municipal solid waste compost is described. The procedure involves a solid-phase dispersion matrix using celite as dispersant sorbent, alumina as clean up sorbent and hexane-dichloromethane (7:3, v/v) mixture as eluting solvent. An additional purification step with copper was necessary to eliminate sulphur. Analysis of the sample was performed by GC-ECD. The method was validated with fortified samples at two concentration levels (0.025 and 0.05 mg kg(-1)). Average recovery ranged from 77 to 121% with relative standard deviation between 1 and 18%. The detection limits, which ranged from 0.003 to 0.01 mg kg-1, were lower than those established by the Baden-Wurttemberg directive (0.033 mg kg(-1)).
Resumo:
A rapid, robust and economical method for the analysis of persistent halogenated organic compounds in small volumes of human serum and umbilical cord blood is described. The pollutants studied cover a broad range of molecules of contemporary epidemiological and legislative concern, including polychlorobiphenyls (PCBs), polychlorobenzenes (CBs), hexachlorocyclohexanes (HCHs), DDTs, polychlorostyrenes (PCSs) and polybromodiphenyl ethers (PBDEs). Extraction and clean-up with n-hexane and concentrated sulphuric acid was followed with analysis by gas chromatography coupled to electron capture (GC-ECD) and GC coupled to negative ion chemical ionisation mass spectrometry (GC-NICI-MS). The advantages of this method rest in the broad range of analytes and its simplicity and robustness, while the use of concentrated sulphuric acid extraction/clean-up destroys viruses that may be present in the samples. Small volumes of reference serum between 50 and 1000 μL were extracted and the limits of detection/quantification and repeatability were determined. Recoveries of spiked compounds for the extraction of small volumes (≥300 μL) of the spiked reference serum were between 90% and 120%. The coefficients of variation of repeatability ranged from 0.1-14%, depending on the compound. Samples of 4-year-old serum and umbilical cord blood (n = 73 and 40, respectively) from a population inhabiting a village near a chloro-alkali plant were screened for the above-mentioned halogenated pollutants using this method and the results are briefly described. © 2010 Springer-Verlag.
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Pós-graduação em Ciências Sociais - FFC
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Ciências Biológicas (Microbiologia Aplicada) - IBRC
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Química - IQ
Resumo:
The degradation of polychlorinated biphenyls (PCBs) was investigated under fermentativemethanogenic conditions for up to 60 days in the presence of anaerobic biomass from a full-scale UASB reactor. The low methane yields in the PCBs-spiked batch reactors suggested that the biomass had an inhibitory effect on the methanogenic community. Reactors containing PCBs and co-substrates (ethanol/ sodium formate) exhibited substantial PCB reductions from 0.7 to 0.2 mg mL-1 . For the Bacteria domain, the PCBs-spiked reactors were grouped with the PCB-free reactors with a similarity of 55 %, which suggested the selection of a specific population in the presence of PCBs. Three genera of bacteria were found exclusively in the PCB-spiked reactors and were identified using pyrosequencing analysis, Sedimentibacter, Tissierela and Fusibacter. Interestingly, the Sedimentibacter, which was previously correlated with the reductive dechlorination of PCBs, had the highest relative abundance in the RCS-PCB (7.4 %) and RCS-PCB-PF (12.4 %) reactors. Thus, the anaerobic sludge from the UASB reactor contains bacteria from the Firmicutes phylum that are capable of degrading PCBs.
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Persistent Organic Pollutants (POPs) are chemical substances extraordinarily toxic and persistent in the environment. Due to these properties, POPs are targets of the Stockholm Convention which aims to provide means to eliminate production and use by encouraging the reduction and, where possible, eliminating the release of these contaminants to the environment. One of the articles of this _Convention aims to assess the basal levels of such substances in the environment to monitor both the reduction of release to the environment, and to assess human exposure, using analyzes of milk and air for example. Although efforts to control POPs production and release to the environment have been made, data about their levels in Brazil are still scarce, mainly in the atmosphere or indoor environment. Considering the permanence of people inside its house, this study presents a method for POP extraction from XAD-2 sorbent employed in indoor air sampling, with identification and quantification by GC-ECD. GC-ECD linear range of the studied analytes, congeners of polychlorinated biphenyls (PCB) (28, 52, 101, 118, 138, 153 and 180), DDTs and their metabolites (DDDs, DDEs) and endosullan (isomers c - and 13 - and metabolite endosulfan sulfate) ranged between 0.5 and 16.0 ng mL-I with r2 > 0.967. The method developing consist of selecting the extraction solvent system by agitation (90 rpm, 1 hour) with n-hexan,e (2 mL) or n-hexane:acetone (1:1, v/v) (2 mL), concentration the extract with a gentle N2 stream, and evaluation of breakthrough with passage or air through the fortified XAD-2 cartridge before extraction, employing a low volume air suction pump (Pump Model 224 universal-PCXR8; 5-5000 mL min-1, SKC Inc., Eighty Four, PA, USA), Calibrator Dry-Cal DC-Lite (BIOS, Butler, NJ, USA)). Two fortification levels were employed, 15 and 30 ng. After selecting n-hexane as extraction solvent, with accuracy and precision ranging...