The following paper proposes a novel application of Skid-to-Turn maneuvers for fixed wing Unmanned Aerial Vehicles (UAVs) inspecting locally linear infrastructure. Fixed wing UAVs, following the design of manned aircraft, commonly employ Bank-to-Turn ma- neuvers to change heading and thus direction of travel. Whilst effective, banking an aircraft during the inspection of ground based features hinders data collection, with body fixed sen- sors angled away from the direction of turn and a panning motion induced through roll rate that can reduce data quality. By adopting Skid-to-Turn maneuvers, the aircraft can change heading whilst maintaining wings level flight, thus allowing body fixed sensors to main- tain a downward facing orientation. An Image-Based Visual Servo controller is developed to directly control the position of features as captured by onboard inspection sensors. This improves on the indirect approach taken by other tracking controllers where a course over ground directly above the feature is assumed to capture it centered in the field of view. Performance of the proposed controller is compared against that of a Bank-to-Turn tracking controller driven by GPS derived cross track error in a simulation environment developed to replicate the field of view of a body fixed camera.
Resumo:
Machine vision represents a particularly attractive solution for sensing and detecting potential collision-course targets due to the relatively low cost, size, weight, and power requirements of the sensors involved. This paper describes the development of detection algorithms and the evaluation of a real-time flight ready hardware implementation of a vision-based collision detection system suitable for fixed-wing small/medium size UAS. In particular, this paper demonstrates the use of Hidden Markov filter to track and estimate the elevation (β) and bearing (α) of the target, compares several candidate graphic processing hardware choices, and proposes an image based visual servoing approach to achieve collision avoidance
Resumo:
This paper examines The Mill Albion community history project, a diverse, multi-layered public history/art program that captures the social heritage of The Albion Flour Mill, as told through images produced as part of a research consultancy undertaken by QUT for FKP Property Group. The Albion Flour Mill was built in 1930 and continued operations for more than 72 years. After ceasing operation in 2005 the site was left to deteriorate. The FKP Property Group purchased the land to undertake a new urban redevelopment project. This paper reflects on the project and showcases some of the culturally creative ways this community’s history was told, using images.
Resumo:
Wireless Multi-media Sensor Networks (WMSNs) have become increasingly popular in recent years, driven in part by the increasing commoditization of small, low-cost CMOS sensors. As such, the challenge of automatically calibrating these types of cameras nodes has become an important research problem, especially for the case when a large quantity of these type of devices are deployed. This paper presents a method for automatically calibrating a wireless camera node with the ability to rotate around one axis. The method involves capturing images as the camera is rotated and computing the homographies between the images. The camera parameters, including focal length, principal point and the angle and axis of rotation can then recovered from two or more homographies. The homography computation algorithm is designed to deal with the limited resources of the wireless sensor and to minimize energy con- sumption. In this paper, a modified RANdom SAmple Consensus (RANSAC) algorithm is proposed to effectively increase the efficiency and reliability of the calibration procedure.
Resumo:
Organisations face increasing competition from new firms in emerging markets and their past superior products may no longer provide competitive advantage in markets based on different cost and value differentials. A shift in design practices from product solutions to health services which are accessible and affordable by all is required. This paper explores a design led approach to innovation to assist medical device companies develop new services and experiences and reshape their notions of the nature, development and deployment of health care services. This approach uses design tools and methodologies that are grounded in the authentic understandings of stakeholder experiences, to assist an organisation create a vision of likely future health care scenarios. Through this process, organisations can explore the complexities in the delivery of future health care services in new and emerging markets allowing them to tailor product and service solutions which focus on being accessible and affordable by all. The industry based case study for the design of health services in carried out in emerging economies. The contribution of this work in advancing research into design innovation and future research directions are also presented.
Resumo:
PURPOSE: To determine if participants with normal visual acuity, no ophthalmoscopically signs of age-related maculopathy (ARM) in both eyes and who are carriers of the CFH, LOC387715 and HRTA1 high-risk genotypes (“gene-positive”) have impaired rod- and cone-mediated mesopic visual function compared to persons who do not carry the risk genotypes (“gene-negative”).---------- METHODS: Fifty-three Caucasian study participants (mean 55.8 ± 6.1) were genotyped for CFH, LOC387715/ARMS2 and HRTA1 polymorphisms. We genotyped single nucleotide polymorphisms (SNPs) in the CFH (rs380390), LOC387715/ARMS2 (rs10490924) and HTRA1 (rs11200638) genes using Applied Biosystems optimised TaqMan assays. We determined the critical fusion frequency (CFF) mediated by cones alone (Long, Middle and Short wavelength sensitive cones; LMS) and by the combined activities of cones and rods (LMSR). The stimuli were generated using a 4-primary photostimulator that provides independent control of the photoreceptor excitation under mesopic light levels. Visual function was further assessed using standard clinical tests, flicker perimetry and microperimetry.---------- RESULTS: The mesopic CFF mediated by rods and cones (LMSR) was significantly reduced in gene-positive compared to gene-negative participants after correction for age (p=0.03). Cone-mediated CFF (LMS) was not significantly different between gene-positive and -negative participants. There were no significant associations between flicker perimetry and microperimetry and genotype.---------- CONCLUSIONS: This is the first study to relate ARM risk genotypes with mesopic visual function in clinically normal persons. These preliminary results could become of clinical importance as mesopic vision may be used to document sub-clinical retinal changes in persons with risk genotypes and to determine whether those persons progress into manifest disease.
Resumo:
Purpose. To investigate the effect of various presbyopic vision corrections on nighttime driving performance on a closed-road driving circuit. Methods. Participants were 11 presbyopes (mean age, 57.3 ± 5.8 years), with a mean best sphere distance refractive error of R+0.23±1.53 DS and L+0.20±1.50 DS, whose only experience of wearing presbyopic vision correction was reading spectacles. The study involved a repeated-measures design by which a participant's nighttime driving performance was assessed on a closed-road circuit while wearing each of four power-matched vision corrections. These included single-vision distance lenses (SV), progressive-addition spectacle lenses (PAL), monovision contact lenses (MV), and multifocal contact lenses (MTF CL) worn in a randomized order. Measures included low-contrast road hazard detection and avoidance, road sign and near target recognition, lane-keeping, driving time, and legibility distance for street signs. Eye movement data (fixation duration and number of fixations) were also recorded. Results. Street sign legibility distances were shorter when wearing MV and MTF CL than SV and PAL (P < 0.001), and participants drove more slowly with MTF CL than with PALs (P = 0.048). Wearing SV resulted in more errors (P < 0.001) and in more (P = 0.002) and longer (P < 0.001) fixations when responding to near targets. Fixation duration was also longer when viewing distant signs with MTF CL than with PAL (P = 0.031). Conclusions. Presbyopic vision corrections worn by naive, unadapted wearers affected nighttime driving. Overall, spectacle corrections (PAL and SV) performed well for distance driving tasks, but SV negatively affected viewing near dashboard targets. MTF CL resulted in the shortest legibility distance for street signs and longer fixation times.
Resumo:
PURPOSE: This study investigated the effects of simulated visual impairment on nighttime driving performance and pedestrian recognition under real-road conditions. METHODS: Closed road nighttime driving performance was measured for 20 young visually normal participants (M = 27.5 +/- 6.1 years) under three visual conditions: normal vision, simulated cataracts, and refractive blur that were incorporated in modified goggles. The visual acuity levels for the cataract and blur conditions were matched for each participant. Driving measures included sign recognition, avoidance of low contrast road hazards, time to complete the course, and lane keeping. Pedestrian recognition was measured for pedestrians wearing either black clothing or black clothing with retroreflective markings on the moveable joints to create the perception of biological motion ("biomotion"). RESULTS: Simulated visual impairment significantly reduced participants' ability to recognize road signs, avoid road hazards, and increased the time taken to complete the driving course (p < 0.05); the effect was greatest for the cataract condition, even though the cataract and blur conditions were matched for visual acuity. Although visual impairment also significantly reduced the ability to recognize the pedestrian wearing black clothing, the pedestrian wearing "biomotion" was seen 80% of the time. CONCLUSIONS: Driving performance under nighttime conditions was significantly degraded by modest visual impairment; these effects were greatest for the cataract condition. Pedestrian recognition was greatly enhanced by marking limb joints in the pattern of "biomotion," which was relatively robust to the effects of visual impairment.
Resumo:
This study examined whether the conspicuity of road workers at night can be enhanced by distributing retroreflective strips across the body to present a pattern of biological motion (biomotion). Twenty visually normal drivers (mean age = 40.3 years) participated in an experiment conducted at two open-road work sites (one suburban and one freeway) at night-time. At each site, four road workers walked in place wearing a standard road worker night vest either (a) alone, (b) with additional retroreflective strips on thighs, (c) with additional retroreflective strips on ankles and knees, or (d) with additional retroreflective strips on eight moveable joints (full biomotion). Participants, seated in stationary vehicles at three different distances (80 m, 160 m, 240 m), rated the relative conspicuity of the four road workers. Road worker conspicuity was maximized by the full biomotion configuration at all distances and at both sites. The addition of ankle and knee markings also provided significant benefits relative to the standard vest alone. The effects of clothing configuration were more evident at the freeway site and at shorter distances. Overall, the full biomotion configuration was ranked to be most conspicuous and the vest least conspicuous. These data provide the first evidence that biomotion effectively enhances conspicuity of road workers at open-road work sites.
Resumo:
Purpose. To investigate the clinical and subjective performance of asmofilcon A, a new third generation silicone hydrogel contact lens during 6-night extended wear (EW) over 6 months. Methods. A prospective, randomized, single-masked study was conducted. Sixty experienced daily wear soft contact lens wearers were randomly assigned to wear either asmofilcon A or senofilcon A contact lenses bilaterally for 6 months on an EW basis. Evaluations were conducted at contact lens delivery and after 1 week, 4 weeks, 3 and 6 months of EW. Results. Fifty subjects (83%) successfully completed the study. Two subjects experienced adverse events; one unilateral red eye with asmofilcon A and one asymptomatic infiltrate with senofilcon A. There were no significant differences in high or low contrast distance visual acuity between asmofilcon A and senofilcon A; however, low contrast distance visual acuity decreased significantly over time with both contact lens types (p < 0.05). The two lens types did not vary significantly with respect to any of the objective and subjective measures assessed (p > 0.05). Superior palpebral conjunctival injection showed a statistically significant increase over time with both lens types (p < 0.05). Both lens types were rated highly with respect to overall comfort, with subjects reporting 14 or 15 h of comfortable lens wearing time per day at each of the study visits (p > 0.05). Overall satisfaction ratings were also very high at all visits, with median scores of 95 (86 to 99) for asmofilcon A and 90 (85 to 96) for senofilcon A at 6 months (p > 0.05). Conclusions. Over 6 months of EW, the asmofilcon A contact lens performed in a similar manner to senofilcon A with respect to visual acuity, ocular health, and contact lens performance measures. Longer-term EW studies are required to investigate the changes over time observed with both lens types.
Resumo:
This paper reports on a six month longitudinal study exploring people’s personal and social emotional experience with health related portable interactive devices (PIDs). The focus is on emotions and how health PIDs mediate this experience in everyday contexts. The study reported here is an extension of a previous experiment conducted by the authors exploring media related PIDs [1]. The findings identified interesting aspects of health device interaction. Findings revealed people interact with health PIDs emotionally both at a personal and a social level. However, in contrast to media PIDs, participants reported significantly less social experiences than personal experiences. Nevertheless, the social level plays an important role such that negative social experiences had a significant influence on the perceived emotional experience over the course of six months. When no negative social experiences were reported the emotional experience over the course of six months became neutral. The findings are discussed in regards to their significance to the field of design, their implication for future health PID design and future research directions.
Resumo:
Aims: This study determined whether the visibility benefits of positioning retroreflective strips in biological motion configurations were evident at real world road worker sites. ---------- Methods: 20 visually normal drivers (M=40.3 years) participated in this study that was conducted at two road work sites (one suburban and one freeway) on two separate nights. At each site, four road workers walked in place wearing one of four different clothing options: a) standard road worker night vest, b) standard night vest plus retroreflective strips on thighs, c) standard night vest plus retroreflective strips on ankles and knees, d) standard night vest plus retroreflective strips on eight moveable joints (full biomotion). Participants seated in stationary vehicles at three different distances (80m, 160m, 240m) rated the relative conspicuity of the four road workers using a series of a standardized visibility and ranking scales. ---------- Results: Adding retroreflective strips in the full biomotion configuration to the standard night vest significantly (p<0.001) enhanced perceptions of road worker visibility compared to the standard vest alone, or in combination with thigh retroreflective markings. These visibility benefits were evident at all distances and at both sites. Retroreflective markings at the ankles and knees also provided visibility benefits compared to the standard vest, however, the full biomotion configuration was significantly better than all of the other configurations. ---------- Conclusions: These data provide the first evidence that the benefits of biomotion retroreflective markings that have been previously demonstrated under laboratory and closed- and open-road conditions are also evident at real work sites.
Resumo:
This paper argues that young people need to be given the opportunity to recognise the interaction between their own understandings of the world as it is now and the vision of what it might become. To support this argument, we discuss an urban planning project, known as the Lower Mill Site Project, which involved active participation of high school students from the local community. The outcomes of this project demonstrate the positive contributions young people can make to the process of urban redevelopment, the advantages of using a participatory design approach, and the utopian possibilities that can emerge when young people are invited to be part of an intergenerational community project.
Resumo:
In vitro cardiovascular device performance evaluation in a mock circulation loop (MCL) is a necessary step prior to in vivo testing.A MCL that accurately represents the physiology of the cardiovascular system accelerates the assessment of the device’s ability to treat pathological conditions. To serve this purpose, a compact MCL measuring 600 ¥ 600 ¥ 600 mm (L ¥ W¥ H) was constructed in conjunction with a computer mathematical simulation.This approach allowed the effective selection of physical loop characteristics, such as pneumatic drive parameters, to create pressure and flow, and pipe dimensions to replicate the resistance, compliance, and fluid inertia of the native cardiovascular system. The resulting five-element MCL reproduced the physiological hemodynamics of a healthy and failing heart by altering ventricle contractility, vascular resistance/compliance, heart rate, and vascular volume. The effects of interpatient anatomical variability, such as septal defects and valvular disease, were also assessed. Cardiovascular hemodynamic pressures (arterial, venous, atrial, ventricular), flows (systemic, bronchial, pulmonary), and volumes (ventricular, stroke) were analyzed in real time. The objective of this study is to describe the developmental stages of the compact MCL and demonstrate its value as a research tool for the accelerated development of cardiovascular devices.
Resumo:
This paper presents the development of a low-cost sensor platform for use in ground-based visual pose estimation and scene mapping tasks. We seek to develop a technical solution using low-cost vision hardware that allows us to accurately estimate robot position for SLAM tasks. We present results from the application of a vision based pose estimation technique to simultaneously determine camera poses and scene structure. The results are generated from a dataset gathered traversing a local road at the St Lucia Campus of the University of Queensland. We show the accuracy of the pose estimation over a 1.6km trajectory in relation to GPS ground truth.