901 resultados para Multidimensional Variable


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present study was to investigate to what extent interstitial lung disease (ILD) in common variable immunodeficiency disorder (CVID)-associated granulomatous disease (GD) is similar to pulmonary sarcoidosis 20 patients with CVID/GD were included in a retrospective study conducted by the Groupe Sarcoïdose Francophone. Medical records were centralised. Patients were compared with 60 controls with sarcoidosis. Clinical examination showed more frequent crackles in patients than controls (45% versus 1.7%, respectively; p<0.001). On thoracic computed tomography scans, nodules (often multiple and with smooth margins), air bronchograms and halo signs were more frequent in patients than controls (80% versus 42%, respectively; p=0.004) as well as bronchiectasis (65% versus 23%, respectively; p<0.001). The micronodule distribution was perilymphatic in 100% of controls and in 42% of patients (p<0.001). Bronchoalveolar lavage analysis showed lower T-cell CD4/CD8 ratios in patients than in controls (mean±sd 1.6±1.1 versus 5.3±4, respectively; p<0.01). On pathological analysis, nodules and consolidations corresponded to granulomatous lesions with or without lymphocytic disorders in most cases. Mortality was higher in patients than controls (30% versus 0%, respectively) and resulted from common variable immunodeficiency complications. ILD in CVID/GD presents a specific clinical picture and evolution that are markedly different from those of sarcoidosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To characterize the clinical, psychophysical, and electrophysiological phenotypes in a five-generation Swiss family with dominantly inherited retinitis pigmentosa caused by a T494M mutation in the Precursor mRNA-Processing factor 3 (PRPF3) gene, and to relate the phenotype to the underlying genetic mutation. METHODS: Eleven affected patients were ascertained for phenotypic and genotypic characterization. Ophthalmologic evaluations included color vision testing, Goldmann perimetry, and digital fundus photography. Some patients had autofluorescence imaging, Optical Coherence Tomography, and ISCEV-standard full-field electroretinography. All affected patients had genetic testing. RESULTS: The age of onset of night blindness and the severity of the progression of the disease varied between members of the family. Some patients reported early onset of night blindness at age three, with subsequent severe deterioration of visual acuity, which was 0.4 in the best eye after their fifties. The second group of patients had a later onset of night blindness, in the mid-twenties, with a milder disease progression and a visual acuity of 0.8 at age 70. Fundus autofluorescence imaging and electrophysiological and visual field abnormalities also showed some degree of varying phenotypes. The autofluorescence imaging showed a large high-density ring bilaterally. Myopia (range: -0.75 to -8) was found in 10/11 affected subjects. Fundus findings showed areas of atrophy along the arcades. A T494M change was found in exon 11 of the PRPF3 gene. The change segregates with the disease in the family. CONCLUSIONS: A mutation in the PRPF3 gene is rare compared to other genes causing autosomal dominant retinitis pigmentosa (ADRP). Although a T494M change has been reported, the family in our study is the first with variable expressivity. Mutations in the PRPF3 gene can cause a variable ADRP phenotype, unlike in the previously described Danish, English, and Japanese families. Our report, based on one of the largest affected pedigree, provides a better understanding as to the phenotype/genotype description of ADRP caused by a PRPF3 mutation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We construct a weighted Euclidean distance that approximates any distance or dissimilarity measure between individuals that is based on a rectangular cases-by-variables data matrix. In contrast to regular multidimensional scaling methods for dissimilarity data, the method leads to biplots of individuals and variables while preserving all the good properties of dimension-reduction methods that are based on the singular-value decomposition. The main benefits are the decomposition of variance into components along principal axes, which provide the numerical diagnostics known as contributions, and the estimation of nonnegative weights for each variable. The idea is inspired by the distance functions used in correspondence analysis and in principal component analysis of standardized data, where the normalizations inherent in the distances can be considered as differential weighting of the variables. In weighted Euclidean biplots we allow these weights to be unknown parameters, which are estimated from the data to maximize the fit to the chosen distances or dissimilarities. These weights are estimated using a majorization algorithm. Once this extra weight-estimation step is accomplished, the procedure follows the classical path in decomposing the matrix and displaying its rows and columns in biplots.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present I-band deep CCD exposures of the fields of galactic plane radio variables. An optical counterpart, based on positional coincidence, has been found for 15 of the 27 observed program objects. The Johnson I magnitude of the sources identified is in the range 18-21.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A considerable fraction of the -ray sources discovered with the Energetic Gamma-Ray Experiment Telescope (EGRET) remain unidentified. The EGRET sources that have been properly identified are either pulsars or variable sources at both radio and gamma-ray wavelengths. Most of the variable sources are strong radio blazars. However, some low galactic-latitude EGRET sources, with highly variable -ray emission, lack any evident counterpart according to the radio data available until now. Aims. The primary goal of this paper is to identify and characterise the potential radio counterparts of four highly variable -ray sources in the galactic plane through mapping the radio surroundings of the EGRET confidence contours and determining the variable radio sources in the field whenever possible. Methods. We have carried out a radio exploration of the fields of the selected EGRET sources using the Giant Metrewave Radio Telescope (GMRT) interferometer at 21 cm wavelength, with pointings being separated by months. Results. We detected a total of 151 radio sources. Among them, we identified a few radio sources whose flux density has apparently changed on timescales of months. Despite the limitations of our search, their possible variability makes these objects a top-priority target for multiwavelength studies of the potential counterparts of highly variable, unidentified gamma-ray sources.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes the development and applications of a super-resolution method, known as Super-Resolution Variable-Pixel Linear Reconstruction. The algorithm works combining different lower resolution images in order to obtain, as a result, a higher resolution image. We show that it can make significant spatial resolution improvements to satellite images of the Earth¿s surface allowing recognition of objects with size approaching the limiting spatial resolution of the lower resolution images. The algorithm is based on the Variable-Pixel Linear Reconstruction algorithm developed by Fruchter and Hook, a well-known method in astronomy but never used for Earth remote sensing purposes. The algorithm preserves photometry, can weight input images according to the statistical significance of each pixel, and removes the effect of geometric distortion on both image shape and photometry. In this paper, we describe its development for remote sensing purposes, show the usefulness of the algorithm working with images as different to the astronomical images as the remote sensing ones, and show applications to: 1) a set of simulated multispectral images obtained from a real Quickbird image; and 2) a set of multispectral real Landsat Enhanced Thematic Mapper Plus (ETM+) images. These examples show that the algorithm provides a substantial improvement in limiting spatial resolution for both simulated and real data sets without significantly altering the multispectral content of the input low-resolution images, without amplifying the noise, and with very few artifacts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Microquasars are binary star systems with relativistic radio-emitting jets. They are potential sources of cosmic rays and can be used to elucidate the physics of relativistic jets. We report the detection of variable gamma-ray emission above 100 gigaelectron volts from the microquasar LS I 61 + 303. Six orbital cycles were recorded. Several detections occur at a similar orbital phase, which suggests that the emission is periodic. The strongest gamma-ray emission is not observed when the two stars are closest to one another, implying a strong orbital modulation of the emission or absorption processes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Document en què es proposen una sèrie d'activitats pràctiques ordenades i agrupades en sessions, per tal de treballar la creativitat i la improvisació musical amb els alumnes de secundària.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Common variable immunodeficiency (CVID), is a disease that is characterized by hypogammaglobulinemia as well as a defect in T, B and dendritic cells. This leads to recurrent bacterial infection mainly caused by Streptococcus pneumoniae, Klebsiella pneumoniae and Haemophilus influenzae, as well as inflammatory manifestations, i.e. granulomateous disease, gastro-intestinal disorders and chronic lung disease. Intravenous Immunoglobulin (IVIg) therapy reduces CVID susceptibility to bacterial infections to some extend. We analyzed clinical aspects of patients from our database. We recently showed that bacteria-specific CD4 T cells of CVID patients were impaired. We therefor postulated that CVID patients may harbor an acquired T-cell deficiency also called exhaustion. To test this hypothesis, we performed a comprehensive investigation of the functional profiles of bacteria-specific CD4 T cells isolated from 31 healthy individuals and 30 CVID patients. In the present study, we demonstrated that bacteria-specific but not virus-specific CD4 T cells in CVID patients harbored reduced proliferation capacity and expressed high level of PD-1. Interestingly, the blockade of PD-1/PD-1 ligands interactions restored partially bacteria but not virus-specific CD4 T-cell proliferation. Finally, we showed that 1) the level of endotoxins inversely correlates with IgG concentration, 2) IVIG treated CVID patients harbored reduced endotoxemia and 3) IgG concentration exceeding 7 mg/mL strongly reduces both the proportion of CVID patients with detectable endotoxemia and the concentration of endotoxins in plasma. Taken together our observations, suggest that primary B-cell defect(s) in CVID patients leads to recurrent bacterial infections that are associated to an acquired (secondary) impairment of CD4 T cells which may in turn exacerbate the lack of protection against extracellular bacteria.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Variable-rate nitrogen fertilization (VRF) based on optical spectrometry sensors of crops is a technological innovation capable of improving the nutrient use efficiency (NUE) and mitigate environmental impacts. However, studies addressing fertilization based on crop sensors are still scarce in Brazilian agriculture. This study aims to evaluate the efficiency of an optical crop sensor to assess the nutritional status of corn and compare VRF with the standard strategy of traditional single-rate N fertilization (TSF) used by farmers. With this purpose, three experiments were conducted at different locations in Southern Brazil, in the growing seasons 2008/09 and 2010/11. The following crop properties were evaluated: above-ground dry matter production, nitrogen (N) content, N uptake, relative chlorophyll content (SPAD) reading, and a vegetation index measured by the optical sensor N-Sensor® ALS. The plants were evaluated in the stages V4, V6, V8, V10, V12 and at corn flowering. The experiments had a completely randomized design at three different sites that were analyzed separately. The vegetation index was directly related to above-ground dry matter production (R² = 0.91; p<0.0001), total N uptake (R² = 0.87; p<0.0001) and SPAD reading (R² = 0.63; p<0.0001) and inversely related to plant N content (R² = 0.53; p<0.0001). The efficiency of VRF for plant nutrition was influenced by the specific climatic conditions of each site. Therefore, the efficiency of the VRF strategy was similar to that of the standard farmer fertilizer strategy at sites 1 and 2. However, at site 3 where the climatic conditions were favorable for corn growth, the use of optical sensors to determine VRF resulted in a 12 % increase in N plant uptake in relation to the standard fertilization, indicating the potential of this technology to improve NUE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Generally, in tropical and subtropical agroecosystems, the efficiency of nitrogen (N) fertilization is low, inducing a temporal variability of crop yield, economic losses, and environmental impacts. Variable-rate N fertilization (VRF), based on optical spectrometry crop sensors, could increase the N use efficiency (NUE). The objective of this study was to evaluate the corn grain yield and N fertilization efficiency under VRF determined by an optical sensor in comparison to the traditional single-application N fertilization (TSF). With this purpose, three experiments with no-tillage corn were carried out in the 2008/09 and 2010/11 growing seasons on a Hapludox in South Brazil, in a completely randomized design, at three different sites that were analyzed separately. The following crop properties were evaluated: aboveground dry matter production and quantity of N uptake at corn flowering, grain yield, and vegetation index determined by an N-Sensor® ALS optical sensor. Across the sites, the corn N fertilizer had a positive effect on corn N uptake, resulting in increased corn dry matter and grain yield. However, N fertilization induced lower increases of corn grain yield at site 2, where there was a severe drought during the growing period. The VRF defined by the optical crop sensor increased the apparent N recovery (NRE) and agronomic efficiency of N (NAE) compared to the traditional fertilizer strategy. In the average of sites 1 and 3, which were not affected by drought, VRF promoted an increase of 28.0 and 41.3 % in NAE and NRE, respectively. Despite these results, no increases in corn grain yield were observed by the use of VRF compared to TSF.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple, low-cost accessory (patent pending) with only two flat mirrors and a new variable-angle mechanism has been developed for infrared specular reflectance measurements. The system allows the angles of incidence to be varied continuously from 15° (near normal incidence) to 85° (near grazing angle) without losing the alignment of the accessory. The reflectivity of boron nitride thin films deposited on metallic substrates has been measured at different angles of incidence to demonstrate the utility of this accessory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, we report the first ever large-scale environmental validation of a microbial reporter-based test to measure arsenic concentrations in natural water resources. A bioluminescence-producing arsenic-inducible bacterium based on Escherichia coli was used as the reporter organism. Specific protocols were developed with the goal to avoid the negative influence of iron in groundwater on arsenic availability to the bioreporter cells. A total of 194 groundwater samples were collected in the Red River and Mekong River Delta regions of Vietnam and were analyzed both by atomic absorption spectroscopy (AAS) and by the arsenic bioreporter protocol. The bacterial cells performed well at and above arsenic concentrations in groundwater of 7 microg/L, with an almost linearly proportional increase of the bioluminescence signal between 10 and 100 microg As/L (r2 = 0.997). Comparisons between AAS and arsenic bioreporter determinations gave an overall average of 8.0% false negative and 2.4% false positive identifications for the bioreporter prediction at the WHO recommended acceptable arsenic concentration of 10 microg/L, which is far betterthan the performance of chemical field test kits. Because of the ease of the measurement protocol and the low application cost, the microbiological arsenic test has a great potential in large screening campaigns in Asia and in other areas suffering from arsenic pollution in groundwater resources.