919 resultados para Multi-method evaluation


Relevância:

40.00% 40.00%

Publicador:

Resumo:

This study aimed to describe the behavior of oviposition traps for Aedes aegypti over time, to compare it with the larval survey and to investigate the association with climatic variables. It was conducted in São José do Rio Preto city, São Paulo. Daily climatic data and fortnightly measurements for oviposition traps and larval infestation were collected from October 2003 to September 2004. Three different periods were identified in the behavior of oviposition traps' positivity and mean number of eggs: increase, plateau and decrease in values. These measurements followed the variation of climatic data from the first and third periods. High correlation was obtained between the positivity and the mean number of eggs. The oviposition traps showed higher capacity to detect the vector than did larval survey. It was observed that the first (October to December) and third (May to September) periods were considered to be the most suitable to use oviposition traps than larval surveys.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We address the problem of scheduling a multi-station multiclassqueueing network (MQNET) with server changeover times to minimizesteady-state mean job holding costs. We present new lower boundson the best achievable cost that emerge as the values ofmathematical programming problems (linear, semidefinite, andconvex) over relaxed formulations of the system's achievableperformance region. The constraints on achievable performancedefining these formulations are obtained by formulatingsystem's equilibrium relations. Our contributions include: (1) aflow conservation interpretation and closed formulae for theconstraints previously derived by the potential function method;(2) new work decomposition laws for MQNETs; (3) new constraints(linear, convex, and semidefinite) on the performance region offirst and second moments of queue lengths for MQNETs; (4) a fastbound for a MQNET with N customer classes computed in N steps; (5)two heuristic scheduling policies: a priority-index policy, anda policy extracted from the solution of a linear programmingrelaxation.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Spatial evaluation of Culicidae (Diptera) larvae from different breeding sites: application of a geospatial method and implications for vector control. This study investigates the spatial distribution of urban Culicidae and informs entomological monitoring of species that use artificial containers as larval habitats. Collections of mosquito larvae were conducted in the São Paulo State municipality of Santa Bárbara d' Oeste between 2004 and 2006 during house-to-house visits. A total of 1,891 samples and nine different species were sampled. Species distribution was assessed using the kriging statistical method by extrapolating municipal administrative divisions. The sampling method followed the norms of the municipal health services of the Ministry of Health and can thus be adopted by public health authorities in disease control and delimitation of risk areas. Moreover, this type of survey and analysis can be employed for entomological surveillance of urban vectors that use artificial containers as larval habitat.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this paper, an extension of the multi-scale finite-volume (MSFV) method is devised, which allows to Simulate flow and transport in reservoirs with complex well configurations. The new framework fits nicely into the data Structure of the original MSFV method,and has the important property that large patches covering the whole well are not required. For each well. an additional degree of freedom is introduced. While the treatment of pressure-constraint wells is trivial (the well-bore reference pressure is explicitly specified), additional equations have to be solved to obtain the unknown well-bore pressure of rate-constraint wells. Numerical Simulations of test cases with multiple complex wells demonstrate the ability of the new algorithm to capture the interference between the various wells and the reservoir accurately. (c) 2008 Elsevier Inc. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The MIT-Scan-T2 device is marketed as a non-destructive way to determine pavement thickness on both HMA and PCC pavements. PCC pavement thickness determination is an important incentivedisincentive measurement for the Iowa DOT and contractors. The thickness incentive can be as much as 3% of the concrete contact unit price and the disincentive can be as severe as remove and replace. This study evaluated the potential of the MIT device for PCC pavement thickness quality assurance. The limited testing indicates the unit is sufficiently repeatable and accurate enough to replace core drilling as the thickness measurement method. Further study is needed to statistically establish the single user and multi-user/device precision as well as establish an appropriate sampling protocol and PWL specification.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

False identity documents constitute a potential powerful source of forensic intelligence because they are essential elements of transnational crime and provide cover for organized crime. In previous work, a systematic profiling method using false documents' visual features has been built within a forensic intelligence model. In the current study, the comparison process and metrics lying at the heart of this profiling method are described and evaluated. This evaluation takes advantage of 347 false identity documents of four different types seized in two countries whose sources were known to be common or different (following police investigations and dismantling of counterfeit factories). Intra-source and inter-sources variations were evaluated through the computation of more than 7500 similarity scores. The profiling method could thus be validated and its performance assessed using two complementary approaches to measuring type I and type II error rates: a binary classification and the computation of likelihood ratios. Very low error rates were measured across the four document types, demonstrating the validity and robustness of the method to link documents to a common source or to differentiate them. These results pave the way for an operational implementation of a systematic profiling process integrated in a developed forensic intelligence model.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A number of claims have been made that polymer modified asphalt cements, multi-grade asphalt cements, and other modifications of the liquid asphalt will prevent rutting and other deterioration of asphalt mixes, thereby, extending the service life of asphalt pavements. This laboratory study evaluates regular AC-20 asphalt cement, PAC-30 polymer modified asphalt cement and AC-10-30 multi-grade asphalt cement. PAC-30 was also evaluated with 15% Gilsonite and 15% Witcurb in a 75% crushed stone - 25% sand mix. These mixtures were evaluated for all Marshall properties along with indirect tensile, resilient modulus, and creep resistance.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The main objective of this work was to compare two methods to estimate the deposition of pesticide applied by aerial spraying. Hundred and fifty pieces of water sensitive paper were distributed over an area of 50 m length by 75 m width for sampling droplets sprayed by an aircraft calibrated to apply a spray volume of 32 L/ha. The samples were analysed by visual microscopic method using NG 2 Porton graticule and by an image analyser computer program. The results reached by visual microscopic method were the following: volume median diameter, 398±62 mum; number median diameter, 159±22 mum; droplet density, 22.5±7.0 droplets/cm² and estimated deposited volume, 22.2±9.4 L/ha. The respective ones reached with the computer program were: 402±58 mum, 161±32 mum, 21.9±7.5 droplets/cm² and 21.9±9.2 L/ha. Graphs of the spatial distribution of droplet density and deposited spray volume on the area were produced by the computer program.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

There are many known examples of multiple semi-independent associations at individual loci; such associations might arise either because of true allelic heterogeneity or because of imperfect tagging of an unobserved causal variant. This phenomenon is of great importance in monogenic traits but has not yet been systematically investigated and quantified in complex-trait genome-wide association studies (GWASs). Here, we describe a multi-SNP association method that estimates the effect of loci harboring multiple association signals by using GWAS summary statistics. Applying the method to a large anthropometric GWAS meta-analysis (from the Genetic Investigation of Anthropometric Traits consortium study), we show that for height, body mass index (BMI), and waist-to-hip ratio (WHR), 3%, 2%, and 1%, respectively, of additional phenotypic variance can be explained on top of the previously reported 10% (height), 1.5% (BMI), and 1% (WHR). The method also permitted a substantial increase (by up to 50%) in the number of loci that replicate in a discovery-validation design. Specifically, we identified 74 loci at which the multi-SNP, a linear combination of SNPs, explains significantly more variance than does the best individual SNP. A detailed analysis of multi-SNPs shows that most of the additional variability explained is derived from SNPs that are not in linkage disequilibrium with the lead SNP, suggesting a major contribution of allelic heterogeneity to the missing heritability.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper presents a customizable system used to develop a collaborative multi-user problem solving game. It addresses the increasing demand for appealing informal learning experiences in museum-like settings. The system facilitates remote collaboration by allowing groups of learners tocommunicate through a videoconferencing system and by allowing them to simultaneously interact through a shared multi-touch interactive surface. A user study with 20 user groups indicates that the game facilitates collaboration between local and remote groups of learners. The videoconference and multitouch surface acted as communication channels, attracted students’ interest, facilitated engagement, and promoted inter- and intra-group collaboration—favoring intra-group collaboration. Our findings suggest that augmentingvideoconferencing systems with a shared multitouch space offers newpossibilities and scenarios for remote collaborative environments and collaborative learning.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The objective of this work was to test a simple method for root hair evaluation of 21 common bean (Phaseolus vulgaris) genotypes, most of them used in breeding programs in Brazil. Hairs of basal and primary roots of 5-day old seedlings, produced on germination paper with no phosphorus addition, were visually evaluated by a rating scale after staining with 0.05% trypan blue. The method reveals variability among the genotypes, and the standard error of the mean is relatively low.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

PURPOSE: To assess the technical feasibility of multi-detector row computed tomographic (CT) angiography in the assessment of peripheral arterial bypass grafts and to evaluate its accuracy and reliability in the detection of graft-related complications, including graft stenosis, aneurysmal changes, and arteriovenous fistulas. MATERIALS AND METHODS: Four-channel multi-detector row CT angiography was performed in 65 consecutive patients with 85 peripheral arterial bypass grafts. Each bypass graft was divided into three segments (proximal anastomosis, course of the graft body, and distal anastomosis), resulting in 255 segments. Two readers evaluated all CT angiograms with regard to image quality and the presence of bypass graft-related abnormalities, including graft stenosis, aneurysmal changes, and arteriovenous fistulas. The results were compared with McNemar test with Bonferroni correction. CT attenuation values were recorded at five different locations from the inflow artery to the outflow artery of the bypass graft. These findings were compared with the findings at duplex ultrasonography (US) in 65 patients and the findings at conventional digital subtraction angiography (DSA) in 27. RESULTS: Image quality was rated as good or excellent in 250 (98%) and in 252 (99%) of 255 bypass segments, respectively. There was excellent agreement both between readers and between CT angiography and duplex US in the detection of graft stenosis, aneurysmal changes, and arteriovenous fistulas (kappa = 0.86-0.99). CT angiography and duplex US were compared with conventional DSA, and there was no statistically significant difference (P >.25) in sensitivity or specificity between CT angiography and duplex US for both readers for detection of hemodynamically significant bypass stenosis or occlusion, aneurysmal changes, or arteriovenous fistulas. Mean CT attenuation values ranged from 232 HU in the inflow artery to 281 HU in the outflow artery of the bypass graft. CONCLUSION: Multi-detector row CT angiography may be an accurate and reliable technique after duplex US in the assessment of peripheral arterial bypass grafts and detection of graft-related complications, including stenosis, aneurysmal changes, and arteriovenous fistulas.