946 resultados para Monitoring methods


Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the relationship between 24-hour ambulatory arterial blood pressure monitoring and the prognosis of patients with advanced congestive heart failure. METHODS: We studied 38 patients with NYHA functional class IV congestive heart failure, and analyzed left ventricular ejection fraction, diastolic diameter, and ambulatory blood pressure monitoring data. RESULTS: Twelve deaths occurred. Left ventricular ejection fraction (35.2±7.3%) and diastolic diameter (72.2±7.8mm) were not correlated with the survival. The mean 24-hour (SBP24), waking (SBPw), and sleeping (SBPs) systolic pressures of the living patients were higher than those of the deceased patients and were significant for predicting survival. Patients with mean SBP24, SBPv, and SBPs > or = 105mmHg had longer survival (p=0.002, p=0.01 and p=0.0007, respectively). Patients with diastolic blood pressure sleep decrements (dip) and patients with mean blood pressure dip <=6mmHg had longer survival (p=0.04 and p=0.01, respectively). In the multivariate analysis, SBPs was the only variable with an odds ratio of 7.61 (CI: 1.56; 3704) (p=0.01). Patients with mean SBP<105mmHg were 7.6 times more likely to die than those with SBP > or = 105 mmHg CONCLUSION: Ambulatory blood pressure monitoring appears to be a useful method for evaluating patients with congestive heart failure.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: The importance of measuring blood pressure before morning micturition and in the afternoon, while working, is yet to be established in relation to the accuracy of home blood pressure monitoring (HBPM). Objective: To compare two HBPM protocols, considering 24-hour ambulatory blood pressure monitoring (wakefulness ABPM) as gold-standard and measurements taken before morning micturition (BM) and in the afternoon (AM), for the best diagnosis of systemic arterial hypertension (SAH), and their association with prognostic markers. Methods: After undergoing 24-hour wakefulness ABPM, 158 participants (84 women) were randomized for 3- or 5-day HBPM. Two variations of the 3-day protocol were considered: with measurements taken before morning micturition and in the afternoon (BM+AM); and with post-morning-micturition and evening measurements (PM+EM). All patients underwent echocardiography (for left ventricular hypertrophy - LVH) and urinary albumin measurement (for microalbuminuria - MAU). Result: Kappa statistic for the diagnosis of SAH between wakefulness-ABPM and standard 3-day HBPM, 3-day HBPM (BM+AM) and (PM+EM), and 5-day HBPM were 0.660, 0.638, 0.348 and 0.387, respectively. The values of sensitivity of (BM+AM) versus (PM+EM) were 82.6% × 71%, respectively, and of specificity, 84.8% × 74%, respectively. The positive and negative predictive values were 69.1% × 40% and 92.2% × 91.2%, respectively. The comparisons of intraclass correlations for the diagnosis of LVH and MAU between (BM+AM) and (PM+EM) were 0.782 × 0.474 and 0.511 × 0.276, respectively. Conclusions: The 3 day-HBPM protocol including measurements taken before morning micturition and during work in the afternoon showed the best agreement with SAH diagnosis and the best association with prognostic markers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: Incomplete compliance is one of several possible causes of uncontrolled hypertension. Yet, non-compliance remains largely unrecognized and is falsely interpreted as treatment resistance, because it is difficult to confirm or exclude objectively. The goal of this study was to evaluate the potential benefits of electronic monitoring of drug compliance in the management of patients with resistant hypertension. METHODS: Forty-one hypertensive patients resistant to a three-drug regimen (average blood pressure 156/ 106 +/- 23/11 mmHg, mean +/- SD) were studied prospectively. They were informed that for the next 2 months, their presently prescribed drugs would be provided in electronic monitors, without any change in treatment, so as to provide the treating physician with a measure of their compliance. Thereafter, patients were offered the possibility of prolonging the monitoring of compliance for another 2 month period, during which treatment was adapted if necessary. RESULTS: Monitoring of compliance alone was associated with a significant improvement of blood pressure at 2 months (145/97 +/- 20/15 mmHg, P < 0.01). During monitoring, blood pressure was normalized (systolic < 140 mmHg or diastolic < 90 mmHg) in one-third of the patients and insufficient compliance was unmasked in another 20%. When analysed according to tertiles of compliance, patients with the lowest compliance exhibited significantly higher achieved diastolic blood pressures (P = 0.04). In 30 patients, compliance was monitored up to 4 months and drug therapy was adapted whenever necessary. In these patients, a further significant decrease in blood pressure was obtained (from 150/100 +/- 18/15 to 143/94 +/- 22/11 mmHg, P = 0.04/0.02). CONCLUSIONS: These results suggest that objective monitoring of compliance using electronic devices may be a useful step in the management of patients with refractory hypertension, as it enables physicians to take rational decisions based on reliable and objective data of drug compliance and hence to improve blood pressure control.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION: Although long-term video-EEG monitoring (LVEM) is routinely used to investigate paroxysmal events, short-term video-EEG monitoring (SVEM) lasting <24 h is increasingly recognized as a cost-effective tool. Since, however, relatively few studies addressed the yield of SVEM among different diagnostic groups, we undertook the present study to investigate this aspect. METHODS: We retrospectively analyzed 226 consecutive SVEM recordings over 6 years. All patients were referred because routine EEGs were inconclusive. Patients were classified into 3 suspected diagnostic groups: (1) group with epileptic seizures, (2) group with psychogenic nonepileptic seizures (PNESs), and (3) group with other or undetermined diagnoses. We assessed recording lengths, interictal epileptiform discharges, epileptic seizures, PNESs, and the definitive diagnoses obtained after SVEM. RESULTS: The mean age was 34 (±18.7) years, and the median recording length was 18.6 h. Among the 226 patients, 127 referred for suspected epilepsy - 73 had a diagnosis of epilepsy, none had a diagnosis of PNESs, and 54 had other or undetermined diagnoses post-SVEM. Of the 24 patients with pre-SVEM suspected PNESs, 1 had epilepsy, 12 had PNESs, and 11 had other or undetermined diagnoses. Of the 75 patients with other diagnoses pre-SVEM, 17 had epilepsy, 11 had PNESs, and 47 had other or undetermined diagnoses. After SVEM, 15 patients had definite diagnoses other than epilepsy or PNESs, while in 96 patients, diagnosis remained unclear. Overall, a definitive diagnosis could be reached in 129/226 (57%) patients. CONCLUSIONS: This study demonstrates that in nearly 3/5 patients without a definitive diagnosis after routine EEG, SVEM allowed us to reach a diagnosis. This procedure should be encouraged in this setting, given its time-effectiveness compared with LVEM.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Questions: A multiple plot design was developed for permanent vegetation plots. How reliable are the different methods used in this design and which changes can we measure? Location: Alpine meadows (2430 m a.s.l.) in the Swiss Alps. Methods: Four inventories were obtained from 40 m(2) plots: four subplots (0.4 m(2)) with a list of species, two 10m transects with the point method (50 points on each), one subplot (4 m2) with a list of species and visual cover estimates as a percentage and the complete plot (40 m(2)) with a list of species and visual estimates in classes. This design was tested by five to seven experienced botanists in three plots. Results: Whatever the sampling size, only 45-63% of the species were seen by all the observers. However, the majority of the overlooked species had cover < 0.1%. Pairs of observers overlooked 10-20% less species than single observers. The point method was the best method for cover estimate, but it took much longer than visual cover estimates, and 100 points allowed for the monitoring of only a very limited number of species. The visual estimate as a percentage was more precise than classes. Working in pairs did not improve the estimates, but one botanist repeating the survey is more reliable than a succession of different observers. Conclusion: Lists of species are insufficient for monitoring. It is necessary to add cover estimates to allow for subsequent interpretations in spite of the overlooked species. The choice of the method depends on the available resources: the point method is time consuming but gives precise data for a limited number of species, while visual estimates are quick but allow for recording only large changes in cover. Constant pairs of observers improve the reliability of the records.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

RESUME Durant les dernières années, les méthodes électriques ont souvent été utilisées pour l'investigation des structures de subsurface. L'imagerie électrique (Electrical Resistivity Tomography, ERT) est une technique de prospection non-invasive et spatialement intégrée. La méthode ERT a subi des améliorations significatives avec le développement de nouveaux algorithmes d'inversion et le perfectionnement des techniques d'acquisition. La technologie multicanale et les ordinateurs de dernière génération permettent la collecte et le traitement de données en quelques heures. Les domaines d'application sont nombreux et divers: géologie et hydrogéologie, génie civil et géotechnique, archéologie et études environnementales. En particulier, les méthodes électriques sont souvent employées dans l'étude hydrologique de la zone vadose. Le but de ce travail est le développement d'un système de monitorage 3D automatique, non- invasif, fiable, peu coûteux, basé sur une technique multicanale et approprié pour suivre les variations de résistivité électrique dans le sous-sol lors d'événements pluvieux. En raison des limitations techniques et afin d'éviter toute perturbation physique dans la subsurface, ce dispositif de mesure emploie une installation non-conventionnelle, où toutes les électrodes de courant sont placées au bord de la zone d'étude. Le dispositif le plus approprié pour suivre les variations verticales et latérales de la résistivité électrique à partir d'une installation permanente a été choisi à l'aide de modélisations numériques. Les résultats démontrent que le dispositif pôle-dipôle offre une meilleure résolution que le dispositif pôle-pôle et plus apte à détecter les variations latérales et verticales de la résistivité électrique, et cela malgré la configuration non-conventionnelle des électrodes. Pour tester l'efficacité du système proposé, des données de terrain ont été collectées sur un site d'étude expérimental. La technique de monitorage utilisée permet de suivre le processus d'infiltration 3D pendant des événements pluvieux. Une bonne corrélation est observée entre les résultats de modélisation numérique et les données de terrain, confirmant par ailleurs que le dispositif pôle-dipôle offre une meilleure résolution que le dispositif pôle-pôle. La nouvelle technique de monitorage 3D de résistivité électrique permet de caractériser les zones d'écoulement préférentiel et de caractériser le rôle de la lithologie et de la pédologie de manière quantitative dans les processus hydrologiques responsables d'écoulement de crue. ABSTRACT During the last years, electrical methods were often used for the investigation of subsurface structures. Electrical resistivity tomography (ERT) has been reported to be a useful non-invasive and spatially integrative prospecting technique. The ERT method provides significant improvements, with the developments of new inversion algorithms, and the increasing efficiency of data collection techniques. Multichannel technology and powerful computers allow collecting and processing resistivity data within few hours. Application domains are numerous and varied: geology and hydrogeology, civil engineering and geotechnics, archaeology and environmental studies. In particular, electrical methods are commonly used in hydrological studies of the vadose zone. The aim of this study was to develop a multichannel, automatic, non-invasive, reliable and inexpensive 3D monitoring system designed to follow electrical resistivity variations in soil during rainfall. Because of technical limitations and in order to not disturb the subsurface, the proposed measurement device uses a non-conventional electrode set-up, where all the current electrodes are located near the edges of the survey grid. Using numerical modelling, the most appropriate arrays were selected to detect vertical and lateral variations of the electrical resistivity in the framework of a permanent surveying installation system. The results show that a pole-dipole array has a better resolution than a pole-pole array and can successfully follow vertical and lateral resistivity variations despite the non-conventional electrode configuration used. Field data are then collected at a test site to assess the efficiency of the proposed monitoring technique. The system allows following the 3D infiltration processes during a rainfall event. A good correlation between the results of numerical modelling and field data results can be observed since the field pole-dipole data give a better resolution image than the pole-pole data. The new device and technique makes it possible to better characterize the zones of preferential flow and to quantify the role of lithology and pedology in flood- generating hydrological processes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: The FIFA has implemented an important antidoping programme for the 2014 FIFA World Cup. AIM: To perform the analyses before and during the World Cup with biological monitoring of blood and urine samples. METHODS: All qualified players from the 32 teams participating in the World Cup were tested out-of-competition. During the World Cup, 2-8 players per match were tested. Over 1000 samples were collected in total and analysed in the WADA accredited Laboratory of Lausanne. RESULTS: The quality of the analyses was at the required level as described in the WADA technical documents. The urinary steroid profiles of the players were stable and consistent with previously published papers on football players. During the competition, amphetamine was detected in a sample collected on a player who had a therapeutic use exemption for attention deficit hyperactivity disorder. The blood passport data showed no significant difference in haemoglobin values between out-of-competition and postmatch samples. CONCLUSIONS: Logistical issues linked to biological samples collection, and the overseas shipment during the World Cup did not impair the quality of the analyses, especially when used as the biological passport of football players.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To reach a consensus on the clinical use of ambulatory blood pressure monitoring (ABPM). METHODS: A task force on the clinical use of ABPM wrote this overview in preparation for the Seventh International Consensus Conference (23-25 September 1999, Leuven, Belgium). This article was amended to account for opinions aired at the conference and to reflect the common ground reached in the discussions. POINTS OF CONSENSUS: The Riva Rocci/Korotkoff technique, although it is prone to error, is easy and cheap to perform and remains worldwide the standard procedure for measuring blood pressure. ABPM should be performed only with properly validated devices as an accessory to conventional measurement of blood pressure. Ambulatory recording of blood pressure requires considerable investment in equipment and training and its use for screening purposes cannot be recommended. ABPM is most useful for identifying patients with white-coat hypertension (WCH), also known as isolated clinic hypertension, which is arbitrarily defined as a clinic blood pressure of more than 140 mmHg systolic or 90 mmHg diastolic in a patient with daytime ambulatory blood pressure below 135 mmHg systolic and 85 mmHg diastolic. Some experts consider a daytime blood pressure below 130 mmHg systolic and 80 mmHg diastolic optimal. Whether WCH predisposes subjects to sustained hypertension remains debated. However, outcome is better correlated to the ambulatory blood pressure than it is to the conventional blood pressure. Antihypertensive drugs lower the clinic blood pressure in patients with WCH but not the ambulatory blood pressure, and also do not improve prognosis. Nevertheless, WCH should not be left unattended. If no previous cardiovascular complications are present, treatment could be limited to follow-up and hygienic measures, which should also account for risk factors other than hypertension. ABPM is superior to conventional measurement of blood pressure not only for selecting patients for antihypertensive drug treatment but also for assessing the effects both of non-pharmacological and of pharmacological therapy. The ambulatory blood pressure should be reduced by treatment to below the thresholds applied for diagnosing sustained hypertension. ABPM makes the diagnosis and treatment of nocturnal hypertension possible and is especially indicated for patients with borderline hypertension, the elderly, pregnant women, patients with treatment-resistant hypertension and patients with symptoms suggestive of hypotension. In centres with sufficient financial resources, ABPM could become part of the routine assessment of patients with clinic hypertension. For patients with WCH, it should be repeated at annual or 6-monthly intervals. Variation of blood pressure throughout the day can be monitored only by ABPM, but several advantages of the latter technique can also be obtained by self-measurement of blood pressure, a less expensive method that is probably better suited to primary practice and use in developing countries. CONCLUSIONS: ABPM or equivalent methods for tracing the white-coat effect should become part of the routine diagnostic and therapeutic procedures applied to treated and untreated patients with elevated clinic blood pressures. Results of long-term outcome trials should better establish the advantage of further integrating ABPM as an accessory to conventional sphygmomanometry into the routine care of hypertensive patients and should provide more definite information on the long-term cost-effectiveness. Because such trials are not likely to be funded by the pharmaceutical industry, governments and health insurance companies should take responsibility in this regard.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The recent advances in sequencing technologies have given all microbiology laboratories access to whole genome sequencing. Providing that tools for the automated analysis of sequence data and databases for associated meta-data are developed, whole genome sequencing will become a routine tool for large clinical microbiology laboratories. Indeed, the continuing reduction in sequencing costs and the shortening of the 'time to result' makes it an attractive strategy in both research and diagnostics. Here, we review how high-throughput sequencing is revolutionizing clinical microbiology and the promise that it still holds. We discuss major applications, which include: (i) identification of target DNA sequences and antigens to rapidly develop diagnostic tools; (ii) precise strain identification for epidemiological typing and pathogen monitoring during outbreaks; and (iii) investigation of strain properties, such as the presence of antibiotic resistance or virulence factors. In addition, recent developments in comparative metagenomics and single-cell sequencing offer the prospect of a better understanding of complex microbial communities at the global and individual levels, providing a new perspective for understanding host-pathogen interactions. Being a high-resolution tool, high-throughput sequencing will increasingly influence diagnostics, epidemiology, risk management, and patient care.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Patient adherence is often poor for hypertension and dyslipidaemia. A monitoring of drug adherence might improve these risk factors control, but little is known in ambulatory care. We conducted a randomised controlled study in networks of community-based pharmacists and physicians in the canton of Fribourg to examine whether monitoring drug adherence with an electronic monitor (MEMS) would improve risk factor control among treated, but uncontrolled hypertensive and dyslipidemic patients. The results indicate that MEMS achieve a better blood pressure control and lipid profile, although its implementation requires considerable resources. The study also shows the value of collaboration between physicians and pharmacists in the field of patient adherence to improve ambulatory care of patients with cardiovascular risk factors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND/AIMS: One of the causes of uncontrolled secondary hyperparathyroidism (sHPT) is patient's poor drug adherence. We evaluated the clinical benefits of an integrated care approach on the control of sHPT by cinacalcet. METHODS: Prospective, randomized, controlled, multicenter, open-label study. Fifty hemodialysis patients on a stable dose of cinacalcet were randomized to an integrated care approach (IC) or usual care approach (UC). In the IC group, cinacalcet adherence was monitored using an electronic system. Results were discussed with the patients in motivational interviews, and drug prescription adapted accordingly. In the UC group, drug adherence was monitored, but results were not available. RESULTS: At six months, 84% of patients in the IC group achieved recommended iPTH targets versus 55% in the UC group (P = 0.04). The mean cinacalcet taking adherence improved by 10.8% in the IC group and declined by 5.3% in the UC group (P = 0.02). Concomitantly, the mean dose of cinacalcet was reduced by 7.2 mg/day in the IC group and increased by 6.4 mg/day in the UC group (P = 0.03). CONCLUSIONS: The use of a drug adherence monitoring program in the management of sHPT in hemodialysis patients receiving cinacalcet improves drug adherence and iPTH control and allows a reduction in the dose of cinacalcet.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The diagnosis of trypanosomosis in animals with low parasitaemia is hampered by low diagnostic sensitivity of traditional detection methods. An immunodiagnostic method based on a direct sandwich enzyme-linked immunosorbent assay (ELISA), using monoclonal antibodies, has been examined in a number of African laboratories for its suitability for monitoring tsetse control and eradication programmes. Generally, the direct sandwich ELISAs for the detection of trypanosomal antigens in serum samples have proved to be unsatisfactory with respect to diagnostic sensitivity when compared with traditional parasitological methods such as the dark ground/phase contrast buffy-coat technique. Consequently, antigen-detection systems exploiting various other direct, indirect and sandwich ELISA systems and sets of reagents are being developed to improve diagnosis. In addition, an existing indirect ELISA for the detection of antibodies has been improved and is being evaluated in the field in order to detect cattle that are or have been recently infected with trypanosomes. Developments and advantages of other diagnostic techniques, such as dip-stick assay and tests based on the polymerase chain reaction are also considered.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Heart transplantation remains the best therapeutic option for the treatment of end-stage heart failure. However, good survival rates can be obtained only if patients are closely monitored, particularly for their immunosuppressive regimens. Currently, a triple-drug regimen usually based on calcineurin-inhibitors (cyclosporin A or tacrolimus), anti-proliferative agents and steroids is used in most recipients. New agents such as the mTOR inhibitors, a more recently developed class of immunosuppressive drugs, can also be used in some patients. The aim of this article is to review currently used immunosuppressive regimens after heart transplantation, and to propose some individualized options depending on specific patient characteristics and recent pharmacological developments in the field.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective Biomonitoring of solvents using the unchanged substance in urine as exposure indicator is still relatively scarce due to some discrepancies between the results reported in the literature. Based on the assessment of toluene exposure, the aim of this work was to evaluate the effects of some steps likely to bias the results and to measure urinary toluene both in volunteers experimentally exposed and in workers of rotogravure factories. Methods Static headspace was used for toluene analysis. o-Cresol was also measured for comparison. Urine collection, storage and conservation conditions were studied to evaluate possible loss or contamination of toluene in controlled situations applied to six volunteers in an exposure chamber according to four scenarios with exposure at stable levels from 10 to 50 ppm. Kinetics of elimination of toluene were determined over 24 h. A field study was then carried out in a total of 29 workers from two rotogravure printing facilities. Results Potential contamination during urine collection in the field is confirmed to be a real problem but technical precautions for sampling, storage and analysis can be easily followed to control the situation. In the volunteers at rest, urinary toluene showed a rapid increase after 2 h with a steady level after about 3 h. At 47.1 ppm the mean cumulated excretion was about 0.005% of the amount of the toluene ventilated. Correlation between the toluene levels in air and in end of exposure urinary sample was excellent (r = 0.965). In the field study, the median personal exposure to toluene was 32 ppm (range 3.6-148). According to the correlations between environmental and biological monitoring data, the post-shift urinary toluene (r = 0.921) and o-cresol (r = 0.873) concentrations were, respectively, 75.6 mu g/l and 0.76 mg/g creatinine for 50 ppm toluene personal exposure. The corresponding urinary toluene concentration before the next shift was 11 mu g/l (r = 0.883). Conclusion Urinary toluene was shown once more time a very interesting surrogate to o-cresol and could be recommended as a biomarker of choice for solvent exposure. [Authors]

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The study of natural T cell responses against pathogens or tumors, as well as the assessment of new immunotherapy strategies aimed at boosting these responses, requires increasingly precise ex vivo analysis of blood samples. For practical reasons, studies are often performed using purified PBMC samples, usually cryopreserved. Here, we report on FACS analyses of peripheral blood T cells, performed by direct antibody staining of non-purified total blood. For comparison, fresh PBMC, purified by Ficoll, were analysed. Our results show that the latter method can induce a bias in subpopulation distribution, in particular of CD8+ T cells, and sometimes lead to inaccurate measurement of antigen specific CD8+ T cell responses. Direct analysis of total blood can be applied to longitudinal immuno-monitoring of T cell-based therapy. While the need to purify and cryopreserve PBMC for subsequent studies is obvious, the use of whole blood has the advantage of providing unbiased results and only small amounts of blood are used.