932 resultados para Modified Direct Analysis Method


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to compare the efficacy of a direct clinical evaluation method with an indirect digital photographic method in assessing the quality of dental restorations. Seven parameters (color, occlusal marginal adaptation, anatomy form, roughness, occlusal marginal stain, luster, and secondary caries) were assessed in 89 Class I and Class II restorations from 36 adults using the modified US Public Health Service/Ryge criteria. Standardized photographs of the same restorations were digitally processed by Adobe Photoshop software, separated into the following four groups and assessed by two calibrated examiners: Group A: The original photograph displayed at 100%, without modifications (IMG100); Group B: Formed by images enlarged at 150% (IMG150); Group C: Formed by digital photographs displayed at 100% (mIMG100), with digital modifications (levels adjustment, shadow and highlight correction, color balance, unsharp Mask); and Group D: Formed by enlarged photographs displayed at 150% with modifications (mIMG150), with the same adjustments made to Group C. Photographs were assessed on a calibrated screen (Macbook) by two calibrated clinicians, and the results were statistically analyzed using Wilcoxon tests (SSPS 11.5) at 95% CI. Results: The photographic method produced higher reliability levels than the direct clinical method in all parameters. The evaluation of digital images is more consistent with clinical assessment when restorations present some moderate defect (Bravo) and less consistent when restorations are clinically classified as either satisfactory (Alpha) or in cases of severe defects (Charlie). Conclusion: The digital photographic method is a useful tool for assessing the quality of dental restorations, providing information that goes unnoticed with the visual-tactile clinical examination method. Additionally, when analyzing restorations using the Ryge modified criteria, the digital photographic method reveals a significant increase of defects compared to those clinically observed with the naked eye. Photography by itself, without the need for enlargement or correction, provides more information than clinical examination and can lead to unnecessary overtreatment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A comparative study using different proportions of CeO2/C (4%, 9% and 13% CeO2) was performed to produce H2O2, a reagent used in the oxidation of organic pollutants and in electro-Fenton reactions for the production of the hydroxyl radical (OH center dot), a strong oxidant agent used in the electrochemical treatment of aqueous wastewater. The CeO2/C materials were prepared by a modified polymeric precursor method (PPM). X-ray diffraction analysis of the CeO2/C prepared by the PPM identified two phases. CeO2 and CeO2. The average size of the crystallites in these materials was close to 7 nm. The kinetics of the oxygen reduction reaction (ORR) were evaluated by the rotating ring-disk electrode technique. The results showed that the 4% CeO2/C prepared by the PPM was the best composite for the production of H2O2 in a 1 mol L-1 NaOH electrolyte solution. For this material, the number of electrons transferred and the H2O2 percentage efficiency were 3.1 and 44%, respectively. The ring-current of the 4% CeO2/C was higher than that of Vulcan carbon, the reference material for H2O2 production, which produced 41% H2O2 and transferred 3.1 electrons per molecule of oxygen. The overpotential for this reaction on the ceria-based catalyst was substantially lower (approximately 200 mV), demonstrating the higher catalytic performance of this material. Gas diffusion electrodes (GDE) containing the catalyst were used to evaluate the real amount of H2O2 produced during exhaustive electrolysis. The 4% CeO2/C GDE produced 871 mg L-1 of H2O2, whereas the Vulcan carbon GDE produced a maximum amount of only 407 mg L-1. Thus, the 4% CeO2/C electrocatalyst prepared by the PPM is a promising material for H2O2 electrogeneration in alkaline media. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The importance of mechanical aspects related to cell activity and its environment is becoming more evident due to their influence in stem cell differentiation and in the development of diseases such as atherosclerosis. The mechanical tension homeostasis is related to normal tissue behavior and its lack may be related to the formation of cancer, which shows a higher mechanical tension. Due to the complexity of cellular activity, the application of simplified models may elucidate which factors are really essential and which have a marginal effect. The development of a systematic method to reconstruct the elements involved in the perception of mechanical aspects by the cell may accelerate substantially the validation of these models. This work proposes the development of a routine capable of reconstructing the topology of focal adhesions and the actomyosin portion of the cytoskeleton from the displacement field generated by the cell on a flexible substrate. Another way to think of this problem is to develop an algorithm to reconstruct the forces applied by the cell from the measurements of the substrate displacement, which would be characterized as an inverse problem. For these kind of problems, the Topology Optimization Method (TOM) is suitable to find a solution. TOM is consisted of an iterative application of an optimization method and an analysis method to obtain an optimal distribution of material in a fixed domain. One way to experimentally obtain the substrate displacement is through Traction Force Microscopy (TFM), which also provides the forces applied by the cell. Along with systematically generating the distributions of focal adhesion and actin-myosin for the validation of simplified models, the algorithm also represents a complementary and more phenomenological approach to TFM. As a first approximation, actin fibers and flexible substrate are represented through two-dimensional linear Finite Element Method. Actin contraction is modeled as an initial stress of the FEM elements. Focal adhesions connecting actin and substrate are represented by springs. The algorithm was applied to data obtained from experiments regarding cytoskeletal prestress and micropatterning, comparing the numerical results to the experimental ones

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper,we present a novel texture analysis method based on deterministic partially self-avoiding walks and fractal dimension theory. After finding the attractors of the image (set of pixels) using deterministic partially self-avoiding walks, they are dilated in direction to the whole image by adding pixels according to their relevance. The relevance of each pixel is calculated as the shortest path between the pixel and the pixels that belongs to the attractors. The proposed texture analysis method is demonstrated to outperform popular and state-of-the-art methods (e.g. Fourier descriptors, occurrence matrix, Gabor filter and local binary patterns) as well as deterministic tourist walk method and recent fractal methods using well-known texture image datasets.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this thesis, numerical methods aiming at determining the eigenfunctions, their adjoint and the corresponding eigenvalues of the two-group neutron diffusion equations representing any heterogeneous system are investigated. First, the classical power iteration method is modified so that the calculation of modes higher than the fundamental mode is possible. Thereafter, the Explicitly-Restarted Arnoldi method, belonging to the class of Krylov subspace methods, is touched upon. Although the modified power iteration method is a computationally-expensive algorithm, its main advantage is its robustness, i.e. the method always converges to the desired eigenfunctions without any need from the user to set up any parameter in the algorithm. On the other hand, the Arnoldi method, which requires some parameters to be defined by the user, is a very efficient method for calculating eigenfunctions of large sparse system of equations with a minimum computational effort. These methods are thereafter used for off-line analysis of the stability of Boiling Water Reactors. Since several oscillation modes are usually excited (global and regional oscillations) when unstable conditions are encountered, the characterization of the stability of the reactor using for instance the Decay Ratio as a stability indicator might be difficult if the contribution from each of the modes are not separated from each other. Such a modal decomposition is applied to a stability test performed at the Swedish Ringhals-1 unit in September 2002, after the use of the Arnoldi method for pre-calculating the different eigenmodes of the neutron flux throughout the reactor. The modal decomposition clearly demonstrates the excitation of both the global and regional oscillations. Furthermore, such oscillations are found to be intermittent with a time-varying phase shift between the first and second azimuthal modes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Das Ziel des Experiments NA48 am CERN ist die Messung des Parameters Re(epsilon'/epsilon) der direktenCP-Verletzung mit einer Genauigkeit von 2x10^-4. Experimentell zugänglich ist das DoppelverhältnisR, das aus den Zerfällen des KL und KS in zwei neutrale bzw. zwei geladene Pionengebildet wird. Für R gilt in guter Näherung: R=1-6Re(epsilon'/epsilon).
NA48 verwendet eine Wichtung der KL-Ereignisse zur Reduzierung der Sensitivität auf dieDetektorakzeptanz. Zur Kontrolle der bisherigen Standardanalyse wurde eine Analyse ohne Ereigniswichtung durchgeführt. Das Ergebnis derungewichteten Analyse wird in dieser Arbeit vorgestellt. Durch Verzicht auf die Ereigniswichtung kann derstatistische Anteil des Gesamtfehlers deutlich verringert werden. Da der limitierende Kanal der Zerfall deslanglebigen Kaons in zwei neutrale Pionen ist, ist die Verwendung der gesamten Anzahl derKL-Zerfälle ein lohnendes Ziel.Im Laufe dieser Arbeit stellte sich heraus, dass dersystematische Fehler der Akzeptanzkorrektur diesen Gewinn wieder aufhebt.

Das Ergebnis der Arbeit für die Daten aus den Jahren 1998und 1999 ohne Ereigniswichtung lautet
Re(epsilon'/epsilon)=(17,91+-4,41(syst.)+-1,36(stat.))x10^-4.
Damit ist eindeutig die Existenz der direkten CP-Verletzungbestätigt. Dieses Ergebnis ist mit dem veröffentlichten Ergebnis vonNA48 verträglichSomit ist der Test der bisherigen Analysestrategie bei NA48erfolgreich durchgeführt worden.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the present study, thin functional conducting polyaniline (PANI) films, either doped or undoped, patterned or unpatterned, were prepared by different approaches. The properties of the obtained PANI films were investigated in detail by a combination of electrochemistry with several other techniques, such as SPR, QCM, SPFS, diffraction, etc. The sensing applications (especially biosensing applications) of the prepared PANI films were explored. Firstly, the pure PANI films were prepared by the electropolymerisation method and their doping/dedoping properties in acidic conditions were investigated in detail by a combination of electrochemistry with SPR and QCM. Dielectric constants of PANI at different oxidation states were obtained quantitatively. The results obtained here laid a good foundation for the following investigations of PANI films in neutral pH conditions. Next, PANI multilayer films doped by a variety of materials were prepared by the layer-by-layer method in order to explore their biosensing applications, because of the loss of redox activity of pure PANI in neutral pH conditions. The dopants used include not only the traditionally used linear polyelectrolytes, but also, for the first tim, some other novel materials, like modified gold nanoparticles or modified carbon nanotubes. Our results showed that all the used dopants could form stable multilayer films with PANI. All the obtained PANI multilayer films showed good redox activity in a neutral pH environment, which makes them feasible for bioassays. We found that all the prepared PANI multilayer films can electrocatalyze the oxidation of NADH in neutral conditions at a low potential, although their catalytic efficiencies are different. Among them, PANI/carbon nanotube system showed the highest catalytic efficiency toward the oxidation of NADH, which makes it a good candidate as a NADH sensor. Besides, because some of the prepared PANI multilayer systems were end-terminated with –COOH groups (like PANI/Au nanoparticles system), which can be utilized to easily link biomolecules for biosensing applications. Here, we demonstrated, for the first time, to use the prepared PANI multilayer films for the DNA hybridisation detection. The detection event was monitored either by direct electrochemical method, or by enzyme-amplified electrochemical method, or by surface plasmon enhanced fluorescence spectroscopic method. All the methods can effectively differentiate non-complementary DNA from the complementary ones, even at the single-base mismatch level. It should also be noted that, our success in fabricating PANI multilayer films with modified Au nanoparticles or carbon nanotubes also offered another novel method for incorporating such novel materials into (conducting) polymers. Because of the unique electrochemical and optical properties of each component of the obtained PANI multilayer films, they should also find potential applications in many other fields such as microelectronics, or for electrochromic and photovoltaic devices. Finally, patterned PANI films were fabricated by the combination of several patterning techniques, such as the combination of electrocopolymerization with micromolding in capillaries (EP-MIMIC), the combination of microcontact printing with the layer-by-layer technique (µCP-LBL), and the polystyrene (PS) template induced electropolymerisation method. Using the obtained stripe-shaped PANI/PSS film, a redox-switchable polymer grating based on the surface-plasmon-enhanced mode was constructed and its application in the field of biosensing was explored. It was found that the diffraction efficiency (DE) of the grating was very sensitive to the applied potential (i.e. redox state of the film) as well as the pH environment of the dielectric medium. Moreover, the DE could also be effectively tuned by an electrocatalytic event, such as the electrocatalytic oxidation of NADH by the grating film. By using PS colloidal crystal assemblies as templates, well-ordered 3D interconnected macroporous PANI arrays (PANI inverse opals) were fabricated via electropolymerisation method. The quality of the obtained inverse opals was much higher than those reported by chemical synthesis method. By electrochemical method, the structures of the prepared inverse opals can be easily controlled. To explore the possible biosensing applications of PANI inverse opals, efforts were also done toward the fabrication of PANI composite inverse opals. By selecting proper dopants, high quality inverse opals of PANI composites were fabricated for the first time. And the obtained opaline films remained redox-active in neutral pH conditions, pointing to their possible applications for electrobioassays.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Im Juli 2009 wurde am Mainzer Mikrotron (MAMI) erstmal ein Experiment durchgeführt, bei dem ein polarisiertes 3He Target mit Photonen im Energiebereich von 200 bis 800 MeV untersucht wurde. Das Ziel dieses Experiments war die Überprüfung der Gerasimov-Drell-Hearn Summenregel am Neutron. Die Verwendung der Messdaten welche mit dem polarisierten 3He Target gewonnen wurden, geben - im Vergleich mit den bereits existieren Daten vom Deuteron - aufgrund der Spin-Struktur des 3He einen komplementären und direkteren Zugang zum Neutron. Die Messung des totalen helizitätsabhängigen Photoabsorptions-Wirkungsquerschnitts wurde mittels eines energiemarkierten Strahls von zirkular polarisierten Photonen, welcher auf das longitudinal polarisierte 3He Target trifft, durchgeführt. Als Produktdetektoren kamen der Crystal Ball (4π Raumabdeckung), TAPS (als ”Vorwärtswand”) sowie ein Schwellen-Cherenkov-Detektor (online Veto zur Reduktion von elektromagnetischen Ereignissen) zum Einsatz. Planung und Aufbau der verschiedenen komponenten Teile des 3He Experimentaufbaus war ein entscheidender Teil dieser Dissertation und wird detailliert in der vorliegenden Arbeit beschrieben. Das Detektorsystem als auch die Analyse-Methoden wurden durch die Messung des unpolarisierten, totalen und inklusiven Photoabsoprtions-Wirkungsquerschnitts an flüssigem Wasserstoff getestet. Hierbei zeigten die Ergebnisse eine gute Übereinstimmung mit bereits zuvor publizierten Daten. Vorläufige Ergebnisse des unpolarisierten totalen Photoabsorptions-Wirkungsquerschnitts sowie der helizitätsabhängige Unterschied zwischen Photoabsorptions-Wirkungsquerschnitten an 3He im Vergleich zu verschiedenen theoretischen Modellen werden vorgestellt.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

L’attuale rilevanza rappresentata dalla stretta relazione tra cambiamenti climatici e influenza antropogenica ha da tempo posto l’attenzione sull’effetto serra e sul surriscaldamento planetario così come sull’aumento delle concentrazioni atmosferiche dei gas climaticamente attivi, in primo luogo la CO2. Il radiocarbonio è attualmente il tracciante ambientale per eccellenza in grado di fornire mediante un approccio “top-down” un valido strumento di controllo per discriminare e quantificare il diossido di carbonio presente in atmosfera di provenienza fossile o biogenica. Ecco allora che ai settori applicativi tradizionali del 14C, quali le datazioni archeometriche, si affiancano nuovi ambiti legati da un lato al settore energetico per quanto riguarda le problematiche associate alle emissioni di impianti, ai combustibili, allo stoccaggio geologico della CO2, dall’altro al mercato in forte crescita dei cosiddetti prodotti biobased costituiti da materie prime rinnovabili. Nell’ambito del presente lavoro di tesi è stato quindi esplorato il mondo del radiocarbonio sia dal punto di vista strettamente tecnico e metodologico che dal punto di vista applicativo relativamente ai molteplici e diversificati campi d’indagine. E’ stato realizzato e validato un impianto di analisi basato sul metodo radiometrico mediante assorbimento diretto della CO2 ed analisi in scintillazione liquida apportando miglioramenti tecnologici ed accorgimenti procedurali volti a migliorare le performance del metodo in termini di semplicità, sensibilità e riproducibilità. Il metodo, pur rappresentando generalmente un buon compromesso rispetto alle metodologie tradizionalmente usate per l’analisi del 14C, risulta allo stato attuale ancora inadeguato a quei settori applicativi laddove è richiesta una precisione molto puntuale, ma competitivo per l’analisi di campioni moderni ad elevata concentrazione di 14C. La sperimentazione condotta su alcuni liquidi ionici, seppur preliminare e non conclusiva, apre infine nuove linee di ricerca sulla possibilità di utilizzare questa nuova classe di composti come mezzi per la cattura della CO2 e l’analisi del 14C in LSC.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In dieser Arbeit wird die bisher präziseste und erste direkte Hochpräzisionsmessung des g-Faktors eines einzelnen Protons präsentiert. Die Messung beruht auf der nicht-destruktiven Bestimmung der Zyklotronfrequenz und der Larmorfrequenz eines in einer Penning-Falle gespeicherten Protons. Zur Bestimmung der Larmorfrequenz wird die Spin-Flip-Wahrscheinlichkeit als Funktion einer externen Spin-Flip-Anregung aufgenommen. Zu diesem Zweck wird der kontinuierliche Stern-Gerlach Effekt verwendet, welcher zu einer Kopplung des Spin-Moments an die axiale Bewegung des Protons führt. Ein Spin-Flip zeigt sich dabei in einem Sprung der axialen Bewegungsfrequenz. Die Schwierigkeit besteht darin, diesen Frequenzsprung auf einem Hintergrund axialer Frequenzfluktuationen zu detektieren. Um diese Herausforderung zu bewältigen, wurden neuartige Methoden und Techniken angewandt. Zum einen wurden supraleitende Nachweise mit höchster Empfindlichkeit entwickelt, welche schnelle und damit präzise Frequenzmessungen erlauben. Zum anderen wurde eine auf dem statistischen Bayes Theorem basierende Spin-Flip-Analyse-Methode angewandt. Mit diesen Verbesserungen war es möglich, einzelne Spin-Flips eines einzelnen Protons zu beobachten. Dies wiederum ermöglichte die Anwendung der sogenannten Doppelfallen-Methode, und damit die eingangs erwähnte Messung des g-Faktors mit einer Präzision von 4.3 10^-9.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this clinical trial was to determine the active tactile sensibility of natural teeth and to obtain a statistical analysis method fitting a psychometric function through the observed data points. On 68 complete dentulous test persons (34 males, 34 females, mean age 45.9 ± 16.1 years), one pair of healthy natural teeth each was tested: n = 24 anterior teeth and n = 44 posterior teeth. The computer-assisted, randomized measurement was done by having the subjects bite on thin copper foils of different thickness (5-200 µm) inserted between the teeth. The threshold of active tactile sensibility was defined by the 50% value of correct answers. Additionally, the gradient of the sensibility curve and the support area (90-10% value) as a description of the shape of the sensibility curve were calculated. For modeling the sensibility curve, symmetric and asymmetric functions were used. The mean sensibility threshold was 14.2 ± 12.1 µm. The older the subject, the higher the tactile threshold (r = 0.42, p = 0.0006). The support area was 41.8 ± 43.3 µm. The higher the 50% threshold, the smaller the gradient of the curve and the larger the support area. The curves showing the active tactile sensibility of natural teeth demonstrate a tendency towards asymmetry, so that the active tactile sensibility of natural teeth can mathematically best be described by using the asymmetric Weibull function.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Craniosynostosis consists of a premature fusion of the sutures in an infant skull that restricts skull and brain growth. During the last decades, there has been a rapid increase of fundamentally diverse surgical treatment methods. At present, the surgical outcome has been assessed using global variables such as cephalic index, head circumference, and intracranial volume. However, these variables have failed in describing the local deformations and morphological changes that may have a role in the neurologic disorders observed in the patients. This report describes a rigid image registration-based method to evaluate outcomes of craniosynostosis surgical treatments, local quantification of head growth, and indirect intracranial volume change measurements. The developed semiautomatic analysis method was applied to computed tomography data sets of a 5-month-old boy with sagittal craniosynostosis who underwent expansion of the posterior skull with cranioplasty. Quantification of the local changes between pre- and postoperative images was quantified by mapping the minimum distance of individual points from the preoperative to the postoperative surface meshes, and indirect intracranial volume changes were estimated. The proposed methodology can provide the surgeon a tool for the quantitative evaluation of surgical procedures and detection of abnormalities of the infant skull and its development.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

It has been highlighted that RNA quality and appropriate reference gene selection is crucial for the interpretation of RT-qPCR results in human placental samples. In this context we investigated the effect of RNA degradation on the mRNA abundance of seven frequently used reference genes in 119 human placental samples. Combining RNA integrity measurements, RT-qPCR analysis and mathematical modeling we found major differences regarding the effect of RNA degradation on the measured expression levels between the different reference genes. Furthermore, we demonstrated that a modified RNA extraction method significantly improved RNA quality and consequently increased transcript levels of all reference genes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Assessment of lung volume (FRC) and ventilation inhomogeneities with ultrasonic flowmeter and multiple breath washout (MBW) has been used to provide important information about lung disease in infants. Sub-optimal adjustment of the mainstream molar mass (MM) signal for temperature and external deadspace may lead to analysis errors in infants with critically small tidal volume changes during breathing. METHODS: We measured expiratory temperature in human infants at 5 weeks of age and examined the influence of temperature and deadspace changes on FRC results with computer simulation modeling. A new analysis method with optimized temperature and deadspace settings was then derived, tested for robustness to analysis errors and compared with the previously used analysis methods. RESULTS: Temperature in the facemask was higher and variations of deadspace volumes larger than previously assumed. Both showed considerable impact upon FRC and LCI results with high variability when obtained with the previously used analysis model. Using the measured temperature we optimized model parameters and tested a newly derived analysis method, which was found to be more robust to variations in deadspace. Comparison between both analysis methods showed systematic differences and a wide scatter. CONCLUSION: Corrected deadspace and more realistic temperature assumptions improved the stability of the analysis of MM measurements obtained by ultrasonic flowmeter in infants. This new analysis method using the only currently available commercial ultrasonic flowmeter in infants may help to improve stability of the analysis and further facilitate assessment of lung volume and ventilation inhomogeneities in infants.