972 resultados para Maximum Bending Stress
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Mesembryanthemum crystallinum L. (Aizoaceae) is a facultative annual halophyte and a C-3-photosynthesis/crassulacean acid metabolism intermediate species currently used as a model plant in stress physiology. Both salinity and high light irradiance stress are known to induce CAM in this species. The present study was performed to provide a diagnosis of alterations at the photosystem 11 level during salinity and irradiance stress. Plants were subjected for up to 13 days to either 0.4M NaCl salinity or high irradiance of 1000 mu mol m(-2) s(-1), as well as to both stress factors combined (LLSA = low light plus salt; HLCO = high light of 1000 mu mol m(-2)s(-1), no salt; HLSA = high light plus salt). A control of LLCO = low light of 200 mu mol m(-2) s(-1), no salt was used. Parameters of chlorophyll a fluorescence of photosystem 11 (PSII) were measured with a pulse amplitude modulated fluorometer. HLCO and LLSA conditions induced a weak degree of CAM with day/night changes of malate levels (Delta malate) of similar to 12 mM in the course of the experiment, while HLSA induced stronger CAM of Delta malate similar to 20mM. Effective quantum yield of PSII, Delta F/F'(m), was only slightly affected by LLSA, somewhat reduced during the course of the experiment by HLCO and clearly reduced by HLSA. Potential quantum efficiency of PSII, F-v/F-m, at predawn times was not affected by any of the conditions, always remaining at >= 0.8, showing that there was no acute photoinhibition. During the course of the days HL alone (HLCO) also did not elicit photoinhibition; salt alone (LLSA) caused acute photoinhibition which was amplified by the combination of the two stresses (HLSA). Non-photochemical, NPQ, quenching remained low (< 0.5) under LLCO, LLSA and HLCO and increased during the course of the experiment under HLSA to 1-2. Maximum apparent photosynthetic electron transport rates, ETRmax, declined during the daily courses and were reduced by LLSA and to a similar extent by HLSA. It is concluded that A crystallinum expresses effective stress tolerance mechanisms but photosynthetic capacity is reduced by the synergistic effects of salinity and tight irradiance stress combined. (c) 2006 Elsevier GmbH. All rights reserved.
Resumo:
A finite element analysis was carried out to study the role of prefabricated threaded split shaft post (Flexi-Post) on dentinal stress in pulpless tooth. Three dimensional plane strain model of mesio-distal section of a human maxillary central incisor without restoration was analysed with the MSC/NASTRAN (MacNeal/ Schwendler) general purpose finite analysis program was executed on a microcomputer. The model as discretized into 48.954 axisymmetric finite elements defined by 10.355 nodes. Each element was assigned unique elastic properties to represent the materials modeled. Homogeneity, isotropy and linear elasticity were assume for all material. A simulation of static load of 100N was applied to the incisal edge of the post; vertical. Maximal principal stresses and von Mises equivalent stress were calculated. Using the element analysis model employed in this study, the following can be concluded concerning threaded split shaft post (Flexi-Post): Maximum principal stresses in dentin were located at cervical place and at the post apex. The apical threads of the post not redirecting stresses away from the root.
Resumo:
High critical temperature superconductors are evolving from a scientific research subject into large-scale application devices. In order to meet this development demand they must withstand high current capacity under mechanical loads arising from thermal contraction during cooling from room temperature down to operating temperature (usually 77 K) and due to the electromagnetic forces generated by the current and the induced magnetic field. Among the HTS materials, the Bi2Sr2Ca2Cu3Ox, compound imbedded in an Ag/AgMg sheath has shown the best results in terms of critical current at 77 K and tolerance against mechanical strain. Aiming to evaluate the influence of thermal stress induced by a number of thermal shock cycles we have evaluated the V-I characteristic curves of samples mounted onto semicircular holders with different curvature radius (9.75 to 44.5 mm). The most deformed sample (epsilon = 1.08%) showed the largest reduction of critical current (40%) compared to the undeformed sample and the highest sensitivity to thermal stress (I-c/I-c0 = 0.5). The V-I characteristic curves were also fitted by a potential curve displaying n-exponents varying from 20 down to 10 between the initial and last thermal shock cycle.
Resumo:
Treatment of urinary stress incontinence (USI) by intravaginal electrical stimulation (IES) and pelvic floor physiotherapy represents an alternative to other therapies. The purpose of this work was to evaluate the effectiveness of this treatment inpatients with urinary incontinence. From January 1998 to May 2000, 30 women (mean age 54 years) were studied. All patients had USI and 70% urge incontinence; average follow-up was 7 months. Selection criteria were based on clinical history, objective evaluation of perineal musculature by perineometry, and urodynamics. The treatment protocol consisted of three sessions of IES per week for 14 weeks using INNOVA equipment. Physiotherapy was initiated in the fifth week of IES. A significant decrease in the number of micturitions and urgency was observed after treatment (P<0.01). The pad test showed a reduction in urinary leakage from 13.9 to 5.9 g after treatment (P<0.01). Objective evaluation of perineal muscle strength showed a significant improvement in all patients after treatment (P<0.01). A positive correlation was observed between maximum flow rate (Q(max)) and all three variables: urethral pressure profile at rest and on straining (stop test), and abdominal leak-point pressure (ALPP). A positive correlation was also observed between ALPP and the stop test. Over 100 different surgical and conservative treatments have been tried to manage USI. The majority of these procedures reveal that despite progress already made in this area, there is no ideal treatment. Satisfactory results can be achieved with this method, especially with patients who are reluctant to undergo surgery because of personal or clinical problems.
Resumo:
Objectives. Evaluate the flexural strength (sigma) and subcritical crack growth (SCG) under cyclic loading of glass-infiltrated alumina-based (IA, In-Ceram Alumina) and zirconia-reinforced (IZ, In-Ceram Zirconia) ceramics, testing the hypothesis that wet environment influences the SCG of both ceramics when submitted to cyclic loading.Methods. Bar-shaped specimens of IA (n = 45) and IZ ( n = 45) were fabricated and loaded in three-point bending (3P) in 37 degrees C artificial saliva (IA(3P) and IZ(3P)) and cyclic fatigued (F) in dry (D) and wet (W) conditions (IA(FD), IA(FW), IZ(FD), IZ(FW)). The initial sigma and the number of cycles to fracture were obtained from 3P and F tests, respectively. Data was examined using Weibull statistics. The SCG behavior was described in terms of crack velocity as a function of maximum stress intensity factor (K(Imax)).Results. The Weibull moduli (m = 8) were similar for both ceramics. The characteristic strength (sigma(0)) of IA and IZ was and 466 MPa 550 MPa, respectively. The wet environment significantly increased the SCG of IZ, whereas a less evident effect was observed for IA. In general, both ceramics were prone to SCG, with crack propagation occurring at K(I) as low as 43-48% of their critical K(I). The highest sigma of IZ should lead to longer lifetimes for similar loading conditions.Significance. Water combined with cyclic loading causes pronounced SCG in IZ and IA materials. The lifetime of dental restorations based on these ceramics is expected to increase by reducing their direct exposure to wet conditions and/or by using high content zirconia ceramics with higher strength. (C) 2010 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Resumo:
Ross male broiler chicks (n = 480) on new litter were used in a randomized block design with two blocks (environmental rooms) and four treatments having four replicate pens (1.0 × 2.5 m; 15 chicks) each to evaluate dietary electrolyte balance (DEB; P < 0.05). Two rooms were 1) thermoneutral (Weeks 1 through 6, with decreasing maximum from 32 to 25°C and minimum from 28 to 19°C; relative humidity 49 to 58%) and 2) cyclic daily heat stress (Weeks 1 and 2, thermoneutral; Weeks 2 through 6, maximum temperatures 35, 35, 33, and 33°C, respectively; and minimum temperatures 23, 20, 19, and 19°C, respectively; relative humidity 51 to 54%). The DEB treatments (0, 140, 240, or 340 mEq Na + K - Cl/kg) had NaHCO3 plus NH4Cl, or KHCO3, or both added to corn-soybean meal mash basal diets with 0.30% salt (NaCl). In the thermoneutral room, DEB 240 increased 42-d weight gain and 44-d lymphocyte percentage and decreased heterophil percentage and heterophil to lymphocyte ratio compared to the DEB 40 treatment. The DEB 240 diets had 0.35 and 0.35% Na and 0.37% and 0.29% Cl in starter (0.75% K) and grower (0.67% K) diets, respectively. No DEB treatment differences were found in the heat stress room. For combined rooms, 42-d feed intake was higher for DEB 240 than for DEB 40. The 21-d weight gain was higher for DEB 240 than for DEB 40 or 140; and 21-d feed/gain was lower for DEB 40 than for DEB 340. The predicted maximum point of inflection for 21- and 42-d weight gains were DEB 250 and 201, with highest 42-d feed intake at 220.
Resumo:
Catecholamines act as neurotransmitters and hormones. Studies conducted to understand the synthesis and metabolism of these monoamines during stress have been the main concern of many authors. This work proposes to investigate the time course of changes in epinephrine and norepinephrine concentration in adrenal gland obtained from rats submitted to acute immobilization stress. The results of the present study indicate that acute immobilization stress during 5 and 15min did not provoke changes in epinephrine and norepinephrine concentrations in adrenal gland in relation to the control group. Such results are justified due to the short time of the stress, showing that the stress did not provoke physiological alteration. The epinephrine and norepinephrine concentrations in adrenal gland increased significantly after the immobilization session in stressed groups during 30 and 50min as compared to control group. This increase probably is due to the emotional component of the immobilization stress. In this way, we suggested that the immobilization stress provoke increase in the biosynthesis of catecholamines in the adrenal gland from rats. However, the results shows that a maximum increase is reached at 30min of immobilization stress and then a decrement of catecholamines levels starts at 50min of the experimental design. This decline in catecholamines level may be consequence of adaptation to stress situations, an increase of the activity of the uptake systems and/or metabolization of catecholamines. In conclusion, these results suggest an effective participation of the adrenal glands to maintain the homeostasis of organism to the stressful conditions. © 2003 Elsevier Ltd. All rights reserved.
Resumo:
Individually caged male Cobb broilers (24), 44 d of age, were used to evaluate effects of heat stress (1 d of data collection) and dietary electrolyte balance (DEB; Na + K - Cl, mEq/kg from 1 d of age). During summer rearing, mortality was variable, but DEB 240 improved growth, feed conversion ratio, water intake, and waterrfeed ratio vs. DEB 0. The temperature sequence for heat stress was 24 to 32°C in 30 min, 32 to 36°C in 30 min, 36 to 37°C in 15 min, and 37 to 41°C in 45 min. Maximum temperature was held for 15, 60, 90, or 360 min for data collection (relative humidity averaged 42 ± 7%). Results from the same room before and after heat stress were analyzed by DEB (1-factor ANOVA) and before vs. after heat stress compared across DEB (2-sample t-test). Heat stress decreased blood Na, K, and pCO2, and lymphocytes but increased heterophils. Blood HCO3 rose, Cl declined, and hematocrit gave a concave pattern (lowest at DEB 120) as DEB increased. After heat stress, DEB O decreased blood Na and K, and DEB O and 120 levels decreased blood HCO3. After heat stress blood pCO2 and hemoglobin decreased with DEB 240, but it had highest pCO2, a key factor. The DEB 120 gave longest times to panting and prostration with DEB O and 240 results lower but similar statistically. In heat stress, DEB 360 was excessive, DEB 120 and 240 were favorable, and DEB 0 was intermediate based on hematology, panting, and prostration responses.
Resumo:
The level of stress during acute or chronic exercise is important since higher levels of stress may impair homeostasis. The adrenal gland is an essential stress-responsive organ involved in the hypothalamic-pituitary-adrenal axis. The aim of the study was to analyze the sensitivity of different stress biomarkers of the adrenal gland during acute treadmill running at different intensities. Adult rats performed three 25 min running tests at velocities of 15, 20 and 25 m/min, for determination of maximum lactate steady state (MLSS). After obtaining individual MLSS animals were assigned to two groups: M, sacrificed after 25 minutes of exercise at MLSS, and AM, sacrificed after exercise at 25% above MLSS. For comparison, a control group C was sacrificed at rest. Blood corticosterone concentrations, as well, adrenal gland cholesterol and ascorbic acid concentrations were used as biomarkers. Serum corticosterone concentrations were higher after exercise in both M (1802,74±700,42) and AM (2027,96±724,94) groups when compared C group (467,11±262,12), but were not different as a function of exercise intensity. No difference in adrenal ascorbic acid (M=2,37±0,66; AM=2,11±0,50 and C=2,54±0,53) and cholesterol (M=1,04±0,12; AM=0,91±0,31 and C=1,15±0,40) levels were observed when the three groups were compared. Serum corticosterone concentrations showed to be sensitive to acute treadmill exercise intensity. On the other hand, ascorbic acid and cholesterol concentrations in adrenal were biomarkers not adequate to evaluate exercise stress in rats.
Resumo:
Aim To assess the dimensional characteristics, flexibility and torsional behaviour of nickel-titanium retreatment instruments. Methodology Using image analysis software and high-resolution digital images, the instrument length, tip angle, diameter at 3mm from the tip and the distance between the blades (pitch length) of the following eight instruments were measured (n=12 for each measurement parameter): the ProTaper Universal retreatment (PTU-R) D1, D2 and D3 instruments; the R-Endo R1, R2 and R3 retreatment instruments; and the Mtwo retreatment (Mtwo-R) sizes 25 and 15 retreatment instruments. Maximum torque and the angular deflection at fracture as well as the bending moment at 45° were measured (n=12) according to the International Standards Organisation (ISO) specification number 3630-1. Data were analysed using the analysis of variance (α=0.05). Results The length of the active part of the instruments was found to vary according to the depth of the canal into which they were designed to reach. The pitch length also increased along the active length. The PTU-R D1 and the Mtwo-R instruments had active tips. Measurements of the bending moment at 45° revealed that the Mtwo-R 15 instrument was the most flexible, whereas the PTU-R D1 was the least flexible. The maximum torque tended to increase as the instrument diameter at 3mm from the tip increased, whereas the angular deflection at fracture varied in the opposite direction. Conclusions The geometrical characteristics of the retreatment instruments and their flexibility and torsion behaviour were consistent with their intended clinical application. © 2011 International Endodontic Journal.
Resumo:
Purpose: To evaluate the stress distribution in peri-implant bone by simulating the effect of an implant with microthreads and platform switching on angled abutments through tridimensional finite element analysis. The postulated hypothesis was that the presence of microthreads and platform switching would reduce the stress concentration in the cortical bone. Methods: Four mathematical models of a central incisor supported by an implant (5.0mm×13mm) were created in which the type of thread surface in the neck portion (microthreaded or smooth) and the diameter of the angled abutment connection (5.0 and 4.1mm) were varied. These models included the RM (regular platform and microthreads), the RS (regular platform and smooth neck surface), the SM (platform switching and microthreads), and the SS (platform switching and smooth neck). The analysis was performed using ANSYS Workbench 10.0 (Swanson Analysis System). An oblique load (100N) was applied to the palatine surface of the central incisor. The bone/implant interface was considered to be perfectly integrated. Values for the maximum (σmax) and minimum (σmin) principal stress, the equivalent von Mises stress (σvM), and the maximum principal elastic strain (e{open}max) for cortical and trabecular bone were obtained. Results: For the cortical bone, the highest σmax (MPa) were observed for the RM (55.1), the RS (51.0), the SM (49.5), and the SS (44.8) models. The highest σvM (MPa) were found for the RM (45.4), the SM (42.1), the RS (38.7), and the SS models (37). The highest values for σmin were found for the RM, SM, RS and SS models. For the trabecular bone, the highest σmax values (MPa) were observed in the RS model (6.55), followed by the RM (6.37), SS (5.6), and SM (5.2) models. Conclusion: The hypothesis that the presence of microthreads and a switching platform would reduce the stress concentration in the cortical bone was partially rejected, mainly because the microthreads increased the stress concentration in cortical bone. Only platform switching reduced the stress in cortical bone. © 2012 Japan Prosthodontic Society.
Resumo:
A finite element analysis was used to compare the effect of different designs of implant-retained overdentures and fixed full-arch implant-supported prosthesis on stress distribution in edentulous mandible. Four models of an human mandible were constructed. In the OR (O'ring) group, the mandible was restored with an overdenture retained by four unsplinted implants with O'ring attachment; in the BC (bar-clip) -C and BC groups, the mandibles were restored with overdentures retained by four splinted implants with bar-clip anchor associated or not with two distally placed cantilevers, respectively; in the FD (fixed denture) group, the mandible was restored with a fixed full-arch four-implant-supported prosthesis. Models were supported by the masticatory muscles and temporomandibular joints. A 100-N oblique load was applied on the left first molar. Von Mises (σvM), maximum (σmax) and minimum (σmin) principal stresses (in MPa) analyses were obtained. BC-C group exhibited the highest stress values (σvM=398.8, σmax=580.5 and σmin=-455.2) while FD group showed the lowest one (σvM=128.9, σmax=185.9 and σmin=-172.1). Within overdenture groups, the use of unsplinted implants reduced the stress level in the implant/prosthetic components (59.4% for σvM, 66.2% for σmax and 57.7% for σmin versus BC-C group) and supporting tissues (maximum stress reduction of 72% and 79.5% for σmax, and 15.7% and 85.7% for σmin on the cortical and trabecular bones, respectively). Cortical bone exhibited greater stress concentration than the trabecular bone for all groups. The use of fixed implant dentures and removable dentures retained by unsplinted implants to rehabilitate edentulous mandible reduced the stresses in the periimplant bone tissue, mucosa and implant/prosthetic components. © 2013 Elsevier Ltd.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)