906 resultados para Luminescent device


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This report describes a simple, inexpensive and highly effective instructional model based on the use of a tablet device to enable the real-time projection of the instructor's digitally handwritten annotations to teach chemistry in undergraduate courses. The projection of digital handwriting allows the instructor to build, present and adapt the class contents in a dynamic fashion and to save anything that is annotated or displayed on the screen for subsequent sharing with students after each session. This method avoids the loss of continuity and information that often occurs when instructors switch between electronic slides and white/chalk board during lessons. Students acknowledged that this methodology allows them to follow the instructor's cognitive process and the progressive development of contents during lectures as the most valuable aspect of the implemented instructional model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Pacemaker implantation (PMI) may predispose to venous thromboembolism (VTE) and obstruction (VO). This prospective study aimed at quantifying changes in venous calibers, and at determining the incidence of symptomatic and asymptomatic VTE/VO after PMI. Further goals included an assessment of the role of transesophageal echocardiography (TEE) in the diagnosis of lead-related central venous thrombi (CVT), and determination of predictors for VTE/VO. Methods: 150 (mean age 67; 61% male) consecutive patients with first PMI were enrolled and followed for 6 months. Contrast venography was performed at baseline and 6 months after PMI to measure venous diameters, and to detect stenosis, total occlusions and thrombi. TEE was conducted in 66 patients. Based on clinical suspicion, work-up for pulmonary embolism (PE) or acute deep vein thrombosis (DVT) were performed as needed. A total of 50 cases underwent longer-term (mean 2.4 years) follow-up venography. All cases with VTE/VO during the initial 6 months, and their matched controls, were selected for a case-control study focused on possible predictive role of laboratory and patient-related factors for the development of VTE/VO. Results: 10 (7 %) patients were found to have baseline venous abnormalities (e.g. 8 obstructions). Mean venous diameters diminished significantly during the first 6 months, but no further reduction occurred in late follow-up. New VO was discovered in 19 patients (14 %; 14 stenosis, 5 total occlusions; all asymptomatic). Small non-obstructive thrombi were found in 20/140 (14 %) 6-month venograms. TEE at 6 months disclosed CVT in 6 (9 %) patients. One (0.7 %) patient had acute symptomatic upper-extremity DVT, and PE was discovered in 5/150 (3.3 %) patients during the first 6 months with no further cases thereafter. At 6 months, the total number of cases with VTE/VO amounted to 47 (31.3 %). Additionally, the later 2-year venograms (n=50) disclosed 4 (8 %) total occlusions and 1 (2 %) stenosis. In the case-control study, no parameter was predictive of venous end-points as a single variable, but there appeared to be significant clustering of traditional VTE risk-factors among the cases. Laboratory parameters showed a definite acute hypercoagulative state induced by PMI, but its degree did not predict subsequent development of VTE/VO. Conclusions: This study shows that VTE/VO is relatively common after PMI with an overall incidence of at least 30 %. Although the majority of the lesions are asymptomatic and clinically benign, cases of PE were also encountered, and totally occluded veins may hamper future upgrading or replacement of pacing system. Venous complications seem difficult to prognosticate as firm predictors were not identified from a wide range of parameters analyzed in this study, although clustering of classic VTE risk factors may be a predisposing factor. Parameters related to implantation procedure or pacing systems and the severity of implantation-induced trauma did not emerge as predictors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The subject being analyzed of this Master’s Thesis is a development of a service that is used to define a current location of a mobile device. The service utilized data that is obtained from own GPS receiver in some possible cases and as well data from mobile devices which can be afforded for the current environment for acquisition of more precise position of the device. The computation environment is based on context of a mobile device. The service is implemented as an application for communicator series Nokia N8XX. The Master’s Thesis presents theoretical concept of the method and its practical implementation, architecture of the application, requirements and describes a process of its functionality. Also users’ work with application is presented and recommendations for possible future improvements are made.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recently most of the mobile phone manufacturer companies started to pay extra attention to their websites. This research investigates the sources of value creation on the mobile phone manufacturers’ website and the affect visiting the manufacturers’ website has on brand loyalty and brand satisfaction. The results show a correlation between positive website usage experience, brand loyalty and brand satisfaction. Moreover there is a relation between Novelty, Efficiency, Lock-in and the perceived usefulness the manufacturers’ website has on the mobile phone device. And finally the main reason behind Finnish student’s mobile phone brand loyalty is its country of origin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diplomityön tavoitteena oli kehittää Wipak Oy:n valmistamille sterilointipakkauksille tulevaisuuden pakkauskonsepti. Sterilointipakkaukset luokitellaan lääkelaitedirektiivin mukaan lisätarvikkeiksi luokan 1 lääkelaitteille, ja tämä näkökulma oli vahvasti mukana konseptin kehityksessä. Lähtökohtana pakkauskonseptin suunnittelulle oli tuotteiden arvoketjussa, eli pakata tuotteet siten että pakkausten avulla voidaan tuottaa lisäarvoa arvoketjun toimijoille. Tavoitteena oli parantaa pakkausten viestintää, toimivuutta/tehokkuutta toimitusketjussa sekä vahvistaa brändin imagoa myynti- ja kuljetuspakkauksen avulla. Lääkinnälliset laitteet ja tarvikkeet ovat lainsäädännön ja normien avulla tarkasti säädeltyjä. Näiden normien vaatimukset asettavat perusteet myynti- ja kuljetuspakkausten kehittämiselle. Tämän lisäksi suunnittelussa on huomioitu asiakkaiden toiveet ja kehitystarpeet. Kirjallisuusosuudessa on keskitytty lääkinnällisten laitteiden pakkausyksiköiden toimintoihin sekä niiden kehitysnäkymiin. Pääpaino on ollut pakkausmerkintöjen ja jäljitettävyyden kehittämisellä, koska tietojen automaattisen tunnistuksen hyödyntäminen lääkintälaitteiden pakkausten arvoketjussa on kasvava trendi. Manuaalisesti tehtävät tuotevirtojen kirjaukset ketjun eri toimijoiden osalta lisäävät riskejä jäljitettävyyden kannalta ja aiheuttavat lisätyötä ja – kustannuksia ketjun kaikille osapuolille. Ehdotus uudesta pakkauskonseptista on kehitetty näiden tietojen pohjalta. Ehdotuksessa on huomioitu lainsäädännöstä ja ketjun toimijoilta tulevat tarpeet, sekä alan tulevaisuuden kehitysnäkymät. Ehdotetun pakkauskonseptin avulla saadaan lisättyä myynti- ja kuljetuspakkausten tehokkuutta, parannettua jäljitettävyyttä ja helpotettu arvoketjun alavirran toimijoiden työtä lisäämällä erillinen sisäpakkaus myyntiyksikön sisälle. Työssä on lisäksi selvitetty pakkauskonseptin kustannusvaikutukset tuotteiden hintaan. Lopussa on ehdotettu jatkotoimenpiteet suunnitelman implementoimisesta käytäntöön.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Due to the importance of the environment on animal production and thus environmental control, the study aims to build a system for monitoring and control the meteorological variables, temperature and relative humidity, low cost, which can be associated with an evaporative cooling system (ECS). The system development included all the stages of assembly, test and laboratory calibration, and later the validation of the equipment carried in the field. The validation step showed results which allowed concluding that the system can be safely used in the monitoring of these variables. The controller was efficient in management of the microclimate in the waiting corral and allowed the maintenance of the air temperature within the comfort range for dairy cattle in pre-milking with averaged 25.09 ºC during the afternoon. The equipment showed the lower cost (R$ 325.76) when compared to other middle market (R$ 450.00).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: to present our experience with scheduled reoperations in 15 patients with intra-abdominal sepsis. METHODS: we have applied a more effective technique consisting of temporary abdominal closure with a nylon mesh sheet containing a zipper. We performed reoperations in the operating room under general anesthesia at an average interval of 84 hours. The revision consisted of debridement of necrotic material and vigorous lavage of the involved peritoneal area. The mean age of patients was 38.7 years (range, 15 to 72 years); 11 patients were male, and four were female. RESULTS: forty percent of infections were due to necrotizing pancreatitis. Sixty percent were due to perforation of the intestinal viscus secondary to inflammation, vascular occlusion or trauma. We performed a total of 48 reoperations, an average of 3.2 surgeries per patient. The mesh-zipper device was left in place for an average of 13 days. An intestinal ostomy was present adjacent to the zipper in four patients and did not present a problem for patient management. Mortality was 26.6%. No fistulas resulted from this technique. When intra-abdominal disease was under control, the mesh-zipper device was removed, and the fascia was closed in all patients. In three patients, the wound was closed primarily, and in 12 it was allowed to close by secondary intent. Two patients developed hernia; one was incisional and one was in the drain incision. CONCLUSION: the planned reoperation for manual lavage and debridement of the abdomen through a nylon mesh-zipper combination was rapid, simple, and well-tolerated. It permitted effective management of severe septic peritonitis, easy wound care and primary closure of the abdominal wall.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors present a especially constructed, lightweight, collapsible, portable and low cost model device for skills training in laparoscopic.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lanthanides represent the chemical elements from lanthanum to lutetium. They intrinsically exhibit some very exciting photophysical properties, which can be further enhanced by incorporating the lanthanide ion into organic or inorganic sensitizing structures. A very popular approach is to conjugate the lanthanide ion to an organic chromophore structure forming lanthanide chelates. Another approach, which has quickly gained interest, is to incorporate the lanthanide ions into nanoparticle structures, thus attaining improved specific activity and binding capacity. The lanthanide-based reporters usually express strong luminescence emission, multiple narrow emission lines covering a wide wavelength range, and exceptionally long excited state lifetimes enabling timeresolved detection. Because of these properties, the lanthanide-based reporters have found widespread applications in various fields of life. This study focuses on the field of bioanalytical applications. The aim of the study was to demonstrate the utility of different lanthanide-based reporters in homogeneous Förster resonance energy transfer (FRET)-based bioaffinity assays. Several different model assays were constructed. One was a competitive bioaffinity assay that utilized energy transfer from lanthanide chelate donors to fluorescent protein acceptors. In addition to the conventional FRET phenomenon, a recently discovered non-overlapping FRET (nFRET) phenomenon was demonstrated for the first time for fluorescent proteins. The lack of spectral overlap in the nFRET mechanism provides sensitivity and versatility to energy transfer-based assays. The distance and temperature dependence of these phenomena were further studied in a DNA-hybridization assay. The distance dependence of nFRET deviated from that of FRET, and unlike FRET, nFRET demonstrated clear temperature dependence. Based on these results, a possible excitation mechanism operating in nFRET was proposed. In the study, two enzyme activity assays for caspase-3 were also constructed. One of these was a fluorescence quenching-based enzyme activity assay that utilized novel inorganic particulate reporters called upconverting phosphors (UCPs) as donors. The use of UCPs enabled the construction of a simple, rather inexpensive, and easily automated assay format that had a high throughput rate. The other enzyme activity assay took advantage of another novel reporter class, the lanthanidebinding peptides (LBPs). In this assay, energy was transferred from a LBP to a green fluorescent protein (GFP). Using the LBPs it was possible to avoid the rather laborious, often poorly repeatable, and randomly positioned chemical labeling. In most of the constructed assays, time-resolved detection was used to eliminate the interfering background signal caused by autofluorescence. The improved signal-to-background ratios resulted in increased assay sensitivity, often unobtainable in homogeneous assay formats using conventional organic fluorophores. The anti-Stokes luminescence of the UCPs, however, enabled the elimination of autofluorescence even without time-gating, thus simplifying the instrument setup. Together, the studied reporters and assay formats pave the way for increasingly sensitive, simple, and easily automated bioanalytical applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis is devoted to understanding and improving technologically important III-V compound semiconductor (e.g. GaAs, InAs, and InSb) surfaces and interfaces for devices. The surfaces and interfaces of crystalline III-V materials have a crucial role in the operation of field-effect-transistors (FET) and highefficiency solar-cells, for instance. However, the surfaces are also the most defective part of the semiconductor material and it is essential to decrease the amount of harmful surface or interface defects for the next-generation III-V semiconductor device applications. Any improvement in the crystal ordering at the semiconductor surface reduces the amount of defects and increases the material homogeneity. This is becoming more and more important when the semiconductor device structures decrease to atomic-scale dimensions. Toward that target, the effects of different adsorbates (i.e., Sn, In, and O) on the III-V surface structures and properties have been investigated in this work. Furthermore, novel thin-films have been synthesized, which show beneficial properties regarding the passivation of the reactive III-V surfaces. The work comprises ultra-high-vacuum (UHV) environment for the controlled fabrication of atomically ordered III-V(100) surfaces. The surface sensitive experimental methods [low energy electron diffraction (LEED), scanning tunneling microscopy/spectroscopy (STM/STS), and synchrotron radiation photoelectron spectroscopy (SRPES)] and computational density-functionaltheory (DFT) calculations are utilized for elucidating the atomic and electronic properties of the crucial III-V surfaces. The basic research results are also transferred to actual device tests by fabricating metal-oxide-semiconductor capacitors and utilizing the interface sensitive measurement techniques [capacitance voltage (CV) profiling, and photoluminescence (PL) spectroscopy] for the characterization. This part of the thesis includes the instrumentation of home-made UHV-compatible atomic-layer-deposition (ALD) reactor for growing good quality insulator layers. The results of this thesis elucidate the atomic structures of technologically promising Sn- and In-stabilized III-V compound semiconductor surfaces. It is shown that the Sn adsorbate induces an atomic structure with (1×2)/(1×4) surface symmetry which is characterized by Sn-group III dimers. Furthermore, the stability of peculiar ζa structure is demonstrated for the GaAs(100)-In surface. The beneficial effects of these surface structures regarding the crucial III-V oxide interface are demonstrated. Namely, it is found that it is possible to passivate the III-V surface by a careful atomic-scale engineering of the III-V surface prior to the gate-dielectric deposition. The thin (1×2)/(1×4)-Sn layer is found to catalyze the removal of harmful amorphous III-V oxides. Also, novel crystalline III-V-oxide structures are synthesized and it is shown that these structures improve the device characteristics. The finding of crystalline oxide structures is exploited by solving the atomic structure of InSb(100)(1×2) and elucidating the electronic structure of oxidized InSb(100) for the first time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this master’s thesis was to specify a system requiring minimal configuration and providing maximal connectivity in the vein of Skype but for device management purposes. As peer-to-peer applications are pervasive and especially as Skype is known to provide this functionality, the research was focused on these technologies. The resulting specification was a hybrid of a tiered hierarchical network structure and a Kademlia based DHT. A prototype was produced as a proof-of-concept for the hierarchical topology, demonstrating that the specification was feasible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of the thesis is to examine how a medical device manufacturer can exploit social networking sites as a part of its everyday marketing communications. The ultimate goal is to create an ideal process of developing marketing communications in social networking sites as a medical device manufacturer with the help of theoretical knowledge and hands-on experience. Theoretical part examines the traditional process of developing marketing communications, defines social networking sites and presents marketing activities carried out on these sites as well as introduces the characteristics of healthcare technology industry. Empirical part is collected through participation in medical device manufacturer’s marketing operations and by observing effects of different factors and actions on social media marketing. In addition, completed interviews and a meeting with company’s personnel have been utilized for data collection. This part offers comprehensive information on the examined company’s current marketing operations, industry, and activities carried out on social networking sites. As a result of the thesis a comprehensive process description of integrating and using social networking sites as a part of company’s marketing communications was formed. With the help of the process description factors and actions which have an effect on marketing operations in social networking sites are presented and methods for further developing these activities are introduced.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tässä diplomityössä tutkittiin vaihtoehtoja tehoelektroniikkalaitteiden kotelointiluokan kehittämiseksi. Haasteena paremman suojauksen suunnittelussa on laitteiden tuottama suuri määrä lämpöä, joka vaatii tehokkaan jäähdytyksen. Työn tuloksena saatu prototyyppi IP33 luokkaa varten täyttää standardissa SFS-EN 60529+A1 asetetut vaatimukset kyseiselle kotelointiluokalle. Rakenteessa ja valmistettavuudessa havaittiin muutama ongelma, jotka ovat korjattavissa pienillä muutoksilla. Korkeampia suojausluokkia varten testattiin IP54-luokiteltujen filtterituulettimien vaikutusta laitteen jäähdytykseen. Testien perusteella jäähdytysteho on riittävä ja filtterituulettimet todettiin toimivaksi ratkaisuksi korkeammille suojausluokille. Työn perusteella voidaan todeta, että nykyiset laitteet voidaan muokata vastaamaan IP33 luokan vaatimuksia kohtuullisen pienillä muutoksilla. Tätä korkeammat suojausluokat vaatisivat niin suuria muutoksia designiin, että todennäköisesti täysin uuden laitteen suunnittelu olis kannattavin vaihtoehto.