927 resultados para Interpolation accuracy
Resumo:
PURPOSE: To use measurement by cycling power meters (Pmes) to evaluate the accuracy of commonly used models for estimating uphill cycling power (Pest). Experiments were designed to explore the influence of wind speed and steepness of climb on accuracy of Pest. The authors hypothesized that the random error in Pest would be largely influenced by the windy conditions, the bias would be diminished in steeper climbs, and windy conditions would induce larger bias in Pest. METHODS: Sixteen well-trained cyclists performed 15 uphill-cycling trials (range: length 1.3-6.3 km, slope 4.4-10.7%) in a random order. Trials included different riding position in a group (lead or follow) and different wind speeds. Pmes was quantified using a power meter, and Pest was calculated with a methodology used by journalists reporting on the Tour de France. RESULTS: Overall, the difference between Pmes and Pest was -0.95% (95%CI: -10.4%, +8.5%) for all trials and 0.24% (-6.1%, +6.6%) in conditions without wind (<2 m/s). The relationship between percent slope and the error between Pest and Pmes were considered trivial. CONCLUSIONS: Aerodynamic drag (affected by wind velocity and orientation, frontal area, drafting, and speed) is the most confounding factor. The mean estimated values are close to the power-output values measured by power meters, but the random error is between ±6% and ±10%. Moreover, at the power outputs (>400 W) produced by professional riders, this error is likely to be higher. This observation calls into question the validity of releasing individual values without reporting the range of random errors.
Resumo:
PURPOSE: To prospectively evaluate the accuracy and reliability of "freehand" posttraumatic orbital wall reconstruction with AO (Arbeitsgemeinschaft Osteosynthese) titanium mesh plates by using computer-aided volumetric measurement of the bony orbits. METHODS: Bony orbital volume was measured in 12 patients from coronal CT scan slices using OsiriX Medical Image software. After defining the volumetric limits of the orbit, the segmentation of the bony orbital region of interest of each single slice was performed. At the end of the segmentation process, all regions of interest were grouped and the volume was computed. The same procedure was performed on both orbits, and thereafter the volume of the contralateral uninjured orbit was used as a control for comparison. RESULTS: In all patients, the volume data of the reconstructed orbit fitted that of the contralateral uninjured orbit with accuracy to within 1.85 cm3 (7%). CONCLUSIONS: This preliminary study has demonstrated that posttraumatic orbital wall reconstruction using "freehand" bending and placement of AO titanium mesh plates results in a high success rate in re-establishing preoperative bony volume, which closely approximates that of the contralateral uninjured orbit.
Resumo:
Tässä diplomityössä tutkitaan dispariteettikartan laskennan tehostamista interpoloimalla. Kolmiomittausta käyttämällä stereokuvasta muodostetaan ensin harva dispariteettikartta, jonka jälkeen koko kuvan kattava dispariteettikartta muodostetaan interpoloimalla. Kolmiomittausta varten täytyy tietää samaa reaalimaailman pistettä vastaavat kuvapisteet molemmissa kameroissa. Huolimatta siitä, että vastaavien pisteiden hakualue voidaan pienentää kahdesta ulottuvuudesta yhteen ulottuvuuteen käyttämällä esimerkiksi epipolaarista geometriaa, on laskennallisesti tehokkaampaa määrittää osa dispariteetikartasta interpoloimalla, kuin etsiä vastaavia kuvapisteitä stereokuvista. Myöskin johtuen stereonäköjärjestelmän kameroiden välisestä etäisyydestä, kaikki kuvien pisteet eivät löydy toisesta kuvasta. Näin ollen on mahdotonta määrittää koko kuvan kattavaa dispariteettikartaa pelkästään vastaavista pisteistä. Vastaavien pisteiden etsimiseen tässä työssä käytetään dynaamista ohjelmointia sekä korrelaatiomenetelmää. Reaalimaailman pinnat ovat yleisesti ottaen jatkuvia, joten geometrisessä mielessä on perusteltua approksimoida kuvien esittämiä pintoja interpoloimalla. On myöskin olemassa tieteellistä näyttöä, jonkamukaan ihmisen stereonäkö interpoloi objektien pintoja.
Resumo:
Objective: to assess the diagnostic accuracy of different anthropometric markers in defining low aerobic fitness among adolescents. Methods: cross-sectional study on 2,331 boys and 2,366 girls aged 10 - 18 years. Body mass index (BMI) was measured using standardized methods; body fat (BF) was assessed by bioelectrical impedance. Low aerobic fitness was assessed by the 20-meter shuttle run using the FITNESSGRAMR criteria. Waist was measured in a subsample of 1,933 boys and 1,897 girls. Overweight, obesity and excess fat were defined according to the International Obesity Task Force (IOTF) or FITNESSGRAMR criteria. Results: 38.5% of boys and 46.5% of girls were considered as unfit according to the FITNESSGRAMR criteria. In boys, the area under the ROC curve (AUC) and 95% confidence interval were 66.7 (64.1 - 69.3), 67.1 (64.5 - 69.6) and 64.6 (61.9 - 67.2) for BMI, BF and waist, respectively (P<0.02). In girls, the values were 68.3 (65.9 - 70.8), 63.8 (61.3 - 66.3) and 65.9 (63.4 - 68.4), respectively (P<0.001). In boys, the sensitivity and specificity to diagnose low fitness were 13% and 99% for obesity (IOTF); 38% and 86% for overweight + obesity (IOTF); 28% and 94% for obesity (FITNESSGRAMR) and 42% and 81% for excess fat (FITNESSGRAMR). For girls, the values were 9% and 99% for obesity (IOTF); 33% and 82% for overweight + obesity (IOTF); 22% and 94% for obesity (FITNESSGRAMR) and 26% and 90% for excess fat (FITNESSGRAMR). Conclusions: BMI, not body fat or waist, should be used to define low aerobic fitness. The IOTF BMI cut-points to define obesity have a very low screening capacity and should not be used.
Resumo:
The interpretation of fingerprint evidence depends on the judgments of fingerprint examiners. This study assessed the accuracy of different judgments made by fingerprint examiners following the Analysis, Comparison, and Evaluation (ACE) process. Each examiner was given five marks for analysis, comparison, and evaluation. We compared the experts' judgments against the ground truth and used an annotation platform to evaluate how Chinese fingerprint examiners document their comparisons during the identification process. The results showed that different examiners demonstrated different accuracy of judgments and different mechanisms to reach them.
Resumo:
Tutkielman tavoitteena oli tarkastella innovaatioiden leviämismallien ennustetarkkuuteen vaikuttavia tekijöitä. Tutkielmassa ennustettiin logistisella mallilla matkapuhelinliittymien leviämistä kolmessa Euroopan maassa: Suomessa, Ranskassa ja Kreikassa. Teoriaosa keskittyi innovaatioiden leviämisen ennustamiseen leviämismallien avulla. Erityisesti painotettiin mallien ennustuskykyä ja niiden käytettävyyttä eri tilanteissa. Empiirisessä osassa keskityttiin ennustamiseen logistisella leviämismallilla, joka kalibroitiin eri tavoin koostetuilla aikasarjoilla. Näin tehtyjä ennusteita tarkasteltiin tiedon kokoamistasojen vaikutusten selvittämiseksi. Tutkimusasetelma oli empiirinen, mikä sisälsi logistisen leviämismallin ennustetarkkuuden tutkimista otosdatan kokoamistasoa muunnellen. Leviämismalliin syötettävä data voidaan kerätä kuukausittain ja operaattorikohtaisesti vaikuttamatta ennustetarkkuuteen. Dataan on sisällytettävä leviämiskäyrän käännöskohta, eli pitkän aikavälin huippukysyntäpiste.
Resumo:
Free induction decay (FID) navigators were found to qualitatively detect rigid-body head movements, yet it is unknown to what extent they can provide quantitative motion estimates. Here, we acquired FID navigators at different sampling rates and simultaneously measured head movements using a highly accurate optical motion tracking system. This strategy allowed us to estimate the accuracy and precision of FID navigators for quantification of rigid-body head movements. Five subjects were scanned with a 32-channel head coil array on a clinical 3T MR scanner during several resting and guided head movement periods. For each subject we trained a linear regression model based on FID navigator and optical motion tracking signals. FID-based motion model accuracy and precision was evaluated using cross-validation. FID-based prediction of rigid-body head motion was found to be with a mean translational and rotational error of 0.14±0.21 mm and 0.08±0.13(°) , respectively. Robust model training with sub-millimeter and sub-degree accuracy could be achieved using 100 data points with motion magnitudes of ±2 mm and ±1(°) for translation and rotation. The obtained linear models appeared to be subject-specific as inter-subject application of a "universal" FID-based motion model resulted in poor prediction accuracy. The results show that substantial rigid-body motion information is encoded in FID navigator signal time courses. Although, the applied method currently requires the simultaneous acquisition of FID signals and optical tracking data, the findings suggest that multi-channel FID navigators have a potential to complement existing tracking technologies for accurate rigid-body motion detection and correction in MRI.
Resumo:
PURPOSE: The aim of this study was to systematically compare a comprehensive array of magnetic resonance (MR) imaging features in terms of their sensitivity and specificity to diagnose cervical lymph node metastases in patients with thyroid cancer. MATERIALS AND METHODS: The study included 41 patients with thyroid malignancy who underwent surgical excision of cervical lymph nodes and had preoperative MR imaging ≤4weeks prior to surgery. Three head and neck neuroradiologists independently evaluated all the MR images. Using the pathology results as reference, the sensitivity, specificity and interobserver agreement of each MR imaging characteristic were calculated. RESULTS: On multivariate analysis, no single imaging feature was significantly correlated with metastasis. In general, imaging features demonstrated high specificity, but poor sensitivity and moderate interobserver agreement at best. CONCLUSIONS: Commonly used MR imaging features have limited sensitivity at correctly identifying cervical lymph node metastases in patients with thyroid cancer. A negative neck MR scan should not dissuade a surgeon from performing a neck dissection in patients with thyroid carcinomas.
Resumo:
Thyroid fine-needle aspiration (FNA) cytology is a fast growing field. One of the most developing areas is represented by molecular tests applied to cytological material. Patients that could benefit the most from these tests are those that have been diagnosed as 'indeterminate' on FNA. They could be better stratified in terms of malignancy risk and thus oriented with more confidence to the appropriate management. Taking in to consideration the need to improve and keep high the yield of thyroid FNA, professionals from various fields (i.e. molecular biologists, endocrinologists, nuclear medicine physicians and radiologists) are refining and fine-tuning their diagnostic instruments. In particular, all these developments aim at increasing the negative predictive value of FNA to improve the selection of patients for diagnostic surgery. These advances involve terminology, the application of next-generation sequencing to thyroid FNA, the use of immunocyto- and histo-chemistry, the development of new sampling techniques and the increasing use of nuclear medicine as well as molecular imaging in the management of patients with a thyroid nodule. Herein, we review the recent advances in thyroid FNA cytology that could be of interest to the 'thyroid-care' community, with particular focus on the indeterminate diagnostic category.
Resumo:
There are two main objects in this study: First, to prove the importance of data accuracy to the business success, and second, create a tool for observing and improving the accuracy of ERP systems production master data. Sub-objective is to explain the need for new tool in client company and the meaning of it for the company. In the theoretical part of this thesis the focus is in stating the importance of data accuracy in decision making and it's implications on business success. Also basics of manufacturing planning are introduced in order to explain the key vocabulary. In the empirical part the client company and its need for this study is introduced. New master data report is introduced, and finally, analysing the report and actions based on the results of analysis are explained. The main results of this thesis are finding the interdependence between data accuracy and business success, and providing a report for continuous master data improvement in the client company's ERP system.
Resumo:
In diffusion MRI, traditional tractography algorithms do not recover truly quantitative tractograms and the structural connectivity has to be estimated indirectly by counting the number of fiber tracts or averaging scalar maps along them. Recently, global and efficient methods have emerged to estimate more quantitative tractograms by combining tractography with local models for the diffusion signal, like the Convex Optimization Modeling for Microstructure Informed Tractography (COMMIT) framework. In this abstract, we show the importance of using both (i) proper multi-compartment diffusion models and (ii) adequate multi-shell acquisitions, in order to evaluate the accuracy and the biological plausibility of the tractograms.
Resumo:
PURPOSE: Prostate cancer (PCa) diagnosis relies on clinical suspicion leading to systematic transrectal ultrasound-guided biopsy (TRUSGB). Multiparametric magnetic resonance imaging (mpMRI) allows for targeted biopsy of suspicious areas of the prostate instead of random 12-core biopsy. This method has been shown to be more accurate in detecting significant PCa. However, the precise spatial accuracy of cognitive targeting is unknown. METHODS: Consecutive patients undergoing mpMRI-targeted TRUSGB with cognitive registration (MRTB-COG) followed by robot-assisted radical prostatectomy were included in the present analysis. The regions of interest (ROIs) involved by the index lesion reported on mpMRI were subsequently targeted by two experienced urologists using the cognitive approach. The 27 ROIs were used as spatial reference. Mapping on radical prostatectomy specimen was used as reference to determine true-positive mpMRI findings. Per core correlation analysis was performed. RESULTS: Forty patients were included. Overall, 40 index lesions involving 137 ROIs (mean ROIs per index lesion 3.43) were identified on MRI. After correlating these findings with final pathology, 117 ROIs (85 %) were considered as true-positive lesions. A total of 102 biopsy cores directed toward such true-positive ROIs were available for final analysis. Cognitive targeted biopsy hit the target in 82 % of the cases (84/102). The only identified risk factor for missing the target was an anterior situated ROI (p = 0.01). CONCLUSION: In experienced hands, cognitive MRTB-COG allows for an accuracy of 82 % in hitting the correct target, given that it is a true-positive lesion. Anterior tumors are less likely to be successfully targeted.
Resumo:
BACKGROUND & AIMS: It is not clear whether symptoms alone can be used to estimate the biologic activity of eosinophilic esophagitis (EoE). We aimed to evaluate whether symptoms can be used to identify patients with endoscopic and histologic features of remission. METHODS: Between April 2011 and June 2014, we performed a prospective, observational study and recruited 269 consecutive adults with EoE (67% male; median age, 39 years old) in Switzerland and the United States. Patients first completed the validated symptom-based EoE activity index patient-reported outcome instrument and then underwent esophagogastroduodenoscopy with esophageal biopsy collection. Endoscopic and histologic findings were evaluated with a validated grading system and standardized instrument, respectively. Clinical remission was defined as symptom score <20 (range, 0-100); histologic remission was defined as a peak count of <20 eosinophils/mm(2) in a high-power field (corresponds to approximately <5 eosinophils/median high-power field); and endoscopic remission as absence of white exudates, moderate or severe rings, strictures, or combination of furrows and edema. We used receiver operating characteristic analysis to determine the best symptom score cutoff values for detection of remission. RESULTS: Of the study subjects, 111 were in clinical remission (41.3%), 79 were in endoscopic remission (29.7%), and 75 were in histologic remission (27.9%). When the symptom score was used as a continuous variable, patients in endoscopic, histologic, and combined (endoscopic and histologic remission) remission were detected with area under the curve values of 0.67, 0.60, and 0.67, respectively. A symptom score of 20 identified patients in endoscopic remission with 65.1% accuracy and histologic remission with 62.1% accuracy; a symptom score of 15 identified patients with both types of remission with 67.7% accuracy. CONCLUSIONS: In patients with EoE, endoscopic or histologic remission can be identified with only modest accuracy based on symptoms alone. At any given time, physicians cannot rely on lack of symptoms to make assumptions about lack of biologic disease activity in adults with EoE. ClinicalTrials.gov, Number: NCT00939263.
Resumo:
Objective To evaluate the accuracy of computed tomography for local and lymph node staging of Wilms' tumor. Materials and Methods Each case of Wilms' tumor was evaluated for the presence of abdominal lymph nodes by a radiologist. Signs of capsule and adjacent organ invasion were analyzed. Surgical and histopathological results were taken as the gold standard. Results Sensitivity was 100% for both mesenteric and retroperitoneal lymph nodes detection, and specificity was, respectively, 12% and 33%, with positive predictive value of 8% and 11% and negative predictive value of 100%. Signs of capsular invasion presented sensitivity of 87%, specificity of 77%, positive predictive value of 63% and negative predictive value of 93%. Signs of adjacent organ invasion presented sensitivity of 100%, specificity of 78%, positive predictive value of 37% and negative predictive value of 100%. Conclusion Computed tomography tumor showed low specificity and low positive predictive value in the detection of lymph node dissemination. The absence of detectable lymph nodes makes their presence unlikely, and likewise regarding the evaluation of local behavior of tumors.