994 resultados para Internal logistics flow
Resumo:
The aim of this investigation was to compare the skeletal stability of three different rigid fixation methods after mandibular advancement. Fifty-five class II malocclusion patients treated with the use of bilateral sagittal split ramus osteotomy and mandibular advancement were selected for this retrospective study. Group 1 (n = 17) had miniplates with monocortical screws, Group 2 (n = 16) had bicortical screws and Group 3 (n = 22) had the osteotomy fixed by means of the hybrid technique. Cephalograms were taken preoperatively, 1 week within the postoperative care period, and 6 months after the orthognathic surgery. Linear and angular changes of the cephalometric landmarks of the chin region were measured at each period, and the changes at each cephalometric landmark were determined for the time gaps. Postoperative changes in the mandibular shape were analyzed to determine the stability of fixation methods. There was minimum difference in the relapse of the mandibular advancement among the three groups. Statistical analysis showed no significant difference in postoperative stability. However, a positive correlation between the amount of advancement and the amount of postoperative relapse was demonstrated by the linear multiple regression test (p < 0.05). It can be concluded that all techniques can be used to obtain stable postoperative results in mandibular advancement after 6 months.
Resumo:
Response surface methodology based on Box-Behnken (BBD) design was successfully applied to the optimization in the operating conditions of the electrochemical oxidation of sanitary landfill leachate aimed for making this method feasible for scale up. Landfill leachate was treated in continuous batch-recirculation system, where a dimensional stable anode (DSA(©)) coated with Ti/TiO2 and RuO2 film oxide were used. The effects of three variables, current density (milliampere per square centimeter), time of treatment (minutes), and supporting electrolyte dosage (moles per liter) upon the total organic carbon removal were evaluated. Optimized conditions were obtained for the highest desirability at 244.11 mA/cm(2), 41.78 min, and 0.07 mol/L of NaCl and 242.84 mA/cm(2), 37.07 min, and 0.07 mol/L of Na2SO4. Under the optimal conditions, 54.99 % of chemical oxygen demand (COD) and 71.07 ammonia nitrogen (NH3-N) removal was achieved with NaCl and 45.50 of COD and 62.13 NH3-N with Na2SO4. A new kinetic model predicted obtained from the relation between BBD and the kinetic model was suggested.
Resumo:
An HPLC-PAD method using a gold working electrode and a triple-potential waveform was developed for the simultaneous determination of streptomycin and dihydrostreptomycin in veterinary drugs. Glucose was used as the internal standard, and the triple-potential waveform was optimized using a factorial and a central composite design. The optimum potentials were as follows: amperometric detection, E1=-0.15V; cleaning potential, E2=+0.85V; and reactivation of the electrode surface, E3=-0.65V. For the separation of the aminoglycosides and the internal standard of glucose, a CarboPac™ PA1 anion exchange column was used together with a mobile phase consisting of a 0.070 mol L(-1) sodium hydroxide solution in the isocratic elution mode with a flow rate of 0.8 mL min(-1). The method was validated and applied to the determination of streptomycin and dihydrostreptomycin in veterinary formulations (injection, suspension and ointment) without any previous sample pretreatment, except for the ointments, for which a liquid-liquid extraction was required before HPLC-PAD analysis. The method showed adequate selectivity, with an accuracy of 98-107% and a precision of less than 3.9%.
Resumo:
We reported here for the first time that triboelectric charges on PET sheets can be used to seal and control the flow rate in paper-based devices. The proposed method exhibits simplicity and low cost, provides reversible sealing and minimizes the effect of sample evaporation.
Resumo:
The aim of this present study was to investigate on the effects of concurrent training with blood flow restriction (BFR-CT) and concurrent training (CT) on the aerobic fitness, muscle mass and muscle strength in a cohort of older individuals. 25 healthy older adults (64.7±4.1 years; 69.33±10.8 kg; 1.6±0.1 m) were randomly assigned to experimental groups: CT (n=8, endurance training (ET), 2 days/week for 30-40 min, 50-80% VO2peak and RT, 2 days/week, leg press with 4 sets of 10 reps at 70-80% of 1-RM with 60 s rest), BFR-CT (n=10, ET, similar to CT, but resistance training with blood flow restriction: 2 days/week, leg press with 1 set of 30 and 3 sets of 15 reps at 20-30% 1-RM with 60 s rest) or control group (n=7). Quadriceps cross-sectional area (CSAq), 1-RM and VO2peak were assessed pre- and post-examination (12 wk). The CT and BFR-CT showed similar increases in CSAq post-test (7.3%, P<0.001; 7.6%, P<0.0001, respectively), 1-RM (38.1%, P<0.001; 35.4%, P=0.001, respectively) and VO2peak (9.5%, P=0.04; 10.3%, P=0.02, respectively). The BFR-CT promotes similar neuromuscular and cardiorespiratory adaptations as CT.
Resumo:
Nitric oxide (NO)-mediated vasodilation plays a key role in gastric mucosal defense, and NO-donor drugs may protect against diseases associated with gastric mucosal blood flow (GMBF) deficiencies. In this study, we used the ex vivo gastric chamber method and Laser Doppler Flowmetry to characterize the effects of luminal aqueous NO-donor drug S-nitroso-N-acetylcysteine (SNAC) solution administration compared to aqueous NaNO2 and NaNO3 solutions (pH 7.4) on GMBF in Sprague-Dawley rats. SNAC solutions (600 μM and 12 mM) led to a rapid threefold increase in GMBF, which was maintained during the incubation of the solutions with the gastric mucosa, while NaNO2 or NaNO3 solutions (12 mM) did not affect GMBF. SNAC solutions (600 μM and 12 mM) spontaneously released NO at 37 °C at a constant rate of 0.3 or 14 nmol·mL-1·min-1, respectively, while NaNO2 (12 mM) released NO at a rate of 0.06 nmol·mL-1·min-1 and NaNO3 (12 mM) did not release NO. These results suggest that the SNAC-induced GMBF increase is due to their higher rates of spontaneous NO release compared to equimolar NaNO2 solutions. Taken together, our data indicate that oral SNAC administration is a potential approach for gastric acid-peptic disorder prevention and treatment.
Resumo:
To develop Y-shaped plates with different thicknesses to be used in simulated fractures of the mandibular condyle. Ten plates were developed in Y shape, containing eight holes, and 30 synthetic polyurethane mandible replicas were developed for the study. The load test was performed on an Instron Model 4411 universal testing machine, applying load in the mediolateral and anterior-posterior positions on the head of the condyle. Two-way ANOVA with Tukey testing with a 5% significance level was used. It was observed that when the load was applied in the medial-lateral plate of greater thickness (1.5 mm), it gave the highest strength, while in the anteroposterior direction, the plate with the highest resistance was of the lesser thickness (0.6 mm). A plate with a thickness of 1.5 mm was the one with the highest average value for all displacements. In the anteroposterior direction, the highest values of resistance were seen in the displacement of 15 mm. After comparing the values of the biomechanical testing found in the scientific literature, it is suggested that the use of Y plates are suitable for use in subcondylar fractures within the limitations of the study.
Saphenous vein graft bypass in the treatment of giant cavernous sinus aneurysms: report of two cases
Resumo:
Two cases of giant intracavernous aneurysms treated by high flow bypass with saphenous vein graft between the external carotid artery (ECA) and branches of the middle cerebral artery (MCA) are presented. Very often these aneurysms are unclippable because they are fusiform or have a large neck. Occlusion of the internal carotid artery (ICA) is the treatment of choice in many cases. This procedure has however a high risk of brain infarction. Revascularization of the brain by extra-intracranial anastomosis between the superficial temporal artery (STA) and branches of the MCA is frequently performed. This procedure provides however a low flow bypass and brain infarction may occur. We report two cases of giant cavernous sinus aneurysms treated by high flow bypass and endovascular balloon occlusion of the ICA. Immediate high flow revascularization of MCA branches was achieved and the patients showed no ischemic events. Follow-up of 8 and 14 months after operation shows patency of the venous graft and no neurological deficits. Angiographic control examination showed complete aneurysm occlusion in both cases.
Resumo:
A flow injection method for the quantitative analysis of ketoconazole in tablets, based on the reaction with iron (III) ions, is presented. Ketoconazole forms a red complex with iron ions in an acid medium, with maximum absorbance at 495 nm. The detection limit was estimated to be 1×10--4 mol L-1; the quantitation limit is about 3×10--4 mol L-1 and approximately 30 determinations can be performed in an hour. The results were compared with those obtained with a reference HPLC method. Statistical comparisons were done using the Student's t procedure and the F test. Complete agreement was found at the 0.95 significance level between the proposed flow injection and the HPLC procedures. The two methods present similar precision, i.e., for HPLC the mean relative standard deviation was ca. 1.2% and for FIA ca. 1.6%.
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
FUNDAMENTOS: O tratamento da hanseníase é definido pela classificação de pacientes em paucibacilares (PB) e multibacilares (MB). A OMS (Organização Mundial de Saúde) classifica os doentes de acordo com o número de lesões, mas Ridley-Jopling (R&J) utiliza também exames complementares, porém é de difícil utilização fora dos serviços de referência. Em 2003 foi desenvolvido um teste denominado ML-Flow, uma alternativa à sorologia por ELISA para auxiliar na classificação de pacientes em PB e MB e auxiliar na decisão terapêutica. OBJETIVOS: Observar a concordância entre o teste de ML-Flow e baciloscopia de linfa, exame já consagrado para detecção de MB. Analisar a utilidade do teste de ML-Flow em campo. MATERIAL E MÉTODOS: Estudo retrospectivo avaliando prontuário de 55 pacientes virgens de tratamento, diagnosticados como PB ou MB por R&J. Submetidos à baciloscopia e ao teste de ML-Flow. RESULTADOS: Nos MB, a baciloscopia foi positiva em 80% dos casos, o ML-flow foi positivo em 82,5%. Entre os PB, o ML-Flow foi positivo em 37,5% e a baciloscopia do esfregaço foi negativa em 100% dos casos. A concordância entre os resultados da baciloscopia do esfregaço e ML-Flow foi de 87,5%, kappa=0,59, p<0,001. CONCLUSÃO: Nenhum teste laboratorial é 100% sensível e específico para a correta classificação de todas as formas de hanseníase. O ML-Flow é um teste rápido, de fácil manuseio em campo, menos invasivo que a baciloscopia podendo ser útil para auxiliar na decisão terapêutica em locais de difícil acesso a serviços de referência.
Resumo:
This study evaluated the influence of internal tooth bleaching with 38% hydrogen peroxide (H2O2) on the permeability of the coronal dentin in maxillary anterior teeth and premolars. Seventy teeth (14 per group) were used: central incisors (CI), lateral incisor (LI), canines (C), first premolars (1PM) and second premolars (2PM). Pulp chamber access and transversal sectioning at 2 mm from the cementoenamel junction were performed and the specimens were divided into 2 groups (n= 7): a) no treatment and b) bleaching with 38% H2O2. The bleaching agent was applied to the buccal surface and to the pulp chamber for 10 min. This procedure was repeated 3 times. The specimens were processed histochemically with copper sulfate and rubeanic acid, sectioned longitudinally, and digitalized in a scanner. The area of stained dentin was measured using Image Tool software. Data were analyzed statistically by ANOVA and Tukey's HSD test (?=0.05). There was statistically significant difference (p<0.001) among the untreated groups, CI (0.23 ± 0.26) having the lowest permeability and LI (10.14 ± 1.89) the highest permeability. Among the bleached groups, dentin permeability was increased in all groups of teeth except for 2PM. It may be concluded that bleaching with 38% H2O2 affected dentin permeability near the pulp chamber in maxillary anterior teeth and in first and second premolars.