909 resultados para Indirect ELISA


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We bring together two areas of terahertz (THz) technology that have benefited from recent advancements in research, i.e., graphene, a material that has plasmonic resonances in the THz frequency, and quantum cascade lasers (QCLs), a compact electrically driven unipolar source of THz radiation. We demonstrate the use of single-layer large-area graphene to indirectly modulate a THz QCL operating at 2.0 THz. By tuning the Fermi level of the graphene via a capacitively coupled backgate voltage, the optical conductivity and, hence, the THz transmission can be varied. We show that, by changing the pulsing frequency of the backgate, the THz transmission can be altered. We also show that, by varying the pulsing frequency of the backgate from tens of Hz to a few kHz, the amplitude-modulated THz signal can be switched by 15% from a low state to a high state. © 2009-2012 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

探索建立鱼类寄生圆形碘孢虫(MyxobolusrotundusNemezek,1911,Myxosporea,Bivalvulida)完整孢子酶联免疫吸附试验(Enzyme linkedimmunosorbentassay,ELISA)检测的可行性,对丙酮、戊二醛、甲醛、多聚甲醛、乙醇等几种常用固定剂应用于此方法的效果进行评价,初步建立了针对鱼类黏孢子虫的完整孢子ELISA检测模式。结果显示,同比其他几种固定剂,2%的多聚甲醛、0 25%的戊二醛对圆形碘孢虫完整孢子ELISA有较好的效果,经二者固定后,最

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An indirect inhibitive surface plasmon resonance (SPR) immunoassay was developed for the microcystins (MCs) detection. The bioconjugate of MC-LR and bovine serum albumin (BSA) was immobilized on a CM5 sensor chip. A serial premixture of MC-LR standards (or samples) and monoclonal antibody (mAb) were injected over the functional sensor surface, and the subsequent specific immunoreaction was monitored on the BIAcore 3000 biosensor and generated a signal with an increasing intensity in response to the decreasing MCs concentration. The developed SPR immunoassay has a wide quantitative range in 1-100 mu g L-1. Although not as sensitive as conventional enzyme-linked immunosorbent assay (ELISA), the SPR biosensor offered unique advantages: (I) the sensor chip could be reusable without any significant loss in its binding activity after 50 assay-regeneration cycles, (2) one single assay could be accomplished in 50 min (including 30-min preincubation and 20-min BIAcore analysis), and (3) this method did not require multiple steps. The SPR biosensor was also used to detect MCs in environmental samples, and the results compared well with those obtained by ELISA. We conclude that the SPR biosensor offers outstanding advantages for the MCs detection and may be further developed as a field-portable sensor for real-time monitoring of MCs on site in the near future. (C) 2009 Published by Elsevier B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel chemiluminescent immunoassay method based on gold nanoparticles was developed for the detection of microcystins (MCs). The immunoassay included three main steps: indirect competitive immunoreaction, oxidative dissolution of gold nanoparticles, and indirect determination for MCs with Au3+-catalysed luminol chemiluminesent system. The method has a wide working range (0.05-10 mu g L-1, r(2) = 0.9914), the limit of detection was determined to be 0.024 mu g L-1, which is much lower than the World Health Organization's proposed guidelines (1 mu g L-1) for drinking-water. The proposed method was applied to MC analysis in natural water and fish tissue samples, and most results in the proposed method were in agreement with the conventional indirect competitive enzyme-linked immunosorbent assay method, which indicated that the new chemiluminescent immunoassay was sensitive, reliable, and suitable for MC analysis in natural water and fish tissue samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have investigated the photo-excited capacitance-voltage (C-V) characteristics as well as the photoluminescence spectra under different biases of a wide quantum well (QW) embedded in an n(+)-i-n(+) double-barrier structure. The pronounced peak feature at zero bias in the C-V spectrum observed upon illumination is regarded as a kind of quantum capacitance related to the quantum confined Stark effect, originating from the spatial separation of the photo-generated electron and hole gas in the QW. This fact is further demonstrated through the comparison between the C-V curve with the PL intensity versus applied voltage relationship under the same excitation. The results may provide us with a more direct and sensitive means in the detection of the separation and accumulation of both types of free carriers-electrons and holes-in low-dimensional semiconductor structures, especially in a new type of optical memory cell.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development of a method for determining arsenic species by capillary zone electrophoresis (CZE) with indirect laser-induced fluorescence (LIF) is described in this paper. The buffer pH, the concentration of fluorescein, the nature and the concentration of the background electrolytes (BGEs) were defined. When 2.0 mM NaHCO3 (pH 9.28) with 10(-7) M fluorescein was used as the buffer, arsenite (As(lll), dimethylarsonic acid (DMA), monomethylarsonic acid (MMA), and arsenate (As(V)) were all separated from one another. The limits of detection for the four arsenic species were p p in the range of 0.12-0.54 mg/L. This method was used in the analysis of spiked arsenic species in tap and mineral water to demonstrate its usefulness. The results showed that both the recovery and the reproducibility of the developed method were acceptable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel tris(2,2'-bipyridine)ruthenium(II) (Ru(bpy)3(2+)) cathodic electrochemiluminescence (ECL) was generated at -0.78V at the Pt electrode in acetonitrile (ACN), which suggested that the cathodic ECL differed from conventional cathodic ECL It was found that tripropylamine (TPrA) could enhance this cathodic ECL and the linear range (log-log plot) was 0.2 mu M-0.2 mM. In addition, hydrogen peroxide (H2O2) could inhibit the cathodic ECL and was indirectly detected with the linear range of 27-540 mu M. The RSD (n = 12) of the ECL intensity in the presence of 135 mu M H2O2 was 0.87%. This method was also demonstrated for the fast determination of H2O2 in disinfectant sample and satisfactory results were obtained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Os objetivos buscados pelos autores neste estudo foram produzir e solubilizar a proteína MSP5 recombinante truncada de Anaplasma marginale e avaliar seu desempenho em um ensaio de imunoadsorção enzimática indireto para detecção de anticorpos contra a riquétsia. O gene msp5, exceto a região N-terminal hidrofóbica, foi amplificado por reação em cadeia da polimerase, clonado em plasmídeo pTrcHis-TOPO e expresso em Escherichia coli. A solubilização da proteína recombinante foi avaliada em diferentes pHs e concentrações de uréia. A sensibilidade e a especificidade do ensaio foram avaliados testando-se 66 soros de animais infectados experimentalmente com A. marginale e 96 soros negativos, com o estado de infecção desses animais confirmado por reação em cadeia da polimerase. Um total de 1.666 amostras de soros bovinos, provenientes do Brasil - Rio Grande do Sul (73), Mato Grosso do Sul (91), Pernambuco (86), Bahia (314) e Minas Gerais (267), assim como do Uruguai (32) e Costa Rica (803) foram testadas nos ELISAs com MSP5 truncada e com MSP1a recombinantes, e a concordância entre os dois testes foi avaliada. O ELISA indireto com MSP5 truncada foi capaz de detectar animais infectados com 96,97% de sensibilidade e 100% de especificidade. Nos animais infectados experimentalmente, o ELISA detectou anticorpos do 12o dia após a inoculação (DPI) até o último dia de observação (37o DPI). Os ELISAs para MSP5 e MSP1a apresentaram concordância de 95,67%, com índice kappa de 0,81. Os resultados discordantes apresentaram uma diferença significativa (P < 0,001). Anticorpos contra A. marginale foram detectados em animais de todas asregiões estudadas. O ELISA com MSP5 recombinante truncada apresentou bom desempenho na detecção de anticorpos contra A. marginale, com alta sensibilidade e especificidade, representando uma importante ferramenta para o diagnóstico da anaplasmose bovina em estudos epidemiológicos.