540 resultados para Hollow microneedle
Resumo:
ABSTRACTObjective:identify risk factors for mortality in patients who underwent laparotomy after blunt abdominal trauma.Methods:retrospective study, case-control, which were reviewed medical records of blunt trauma victims patients undergoing laparotomy, from March 2013 to January 2015, and compared the result of the deaths group with the group healed.Results:of 86 patients, 63% were healed, 36% died, and one patient was excluded from the study. Both groups had similar epidemiology and trauma mechanism, predominantly young adults males, automobilistic accident. Most cases that evolved to death had hemodynamic instability as laparotomy indication - 61% against 38% in the other group (p=0.02). The presence of solid organ injury was larger in the group of deaths - 80% versus 48% (p=0.001) and 61% of them had other associated abdominal injury compared to 25% in the other group (p=0.01). Of the patients who died 96% had other serious injuries associated (p=0.0003). Patients requiring damage control surgery had a higher mortality rate (p=0.0099). Only one of 18 patients with isolated hollow organ lesion evolved to death (p=0.0001). The mean injury score of TRISS of cured (91.70%) was significantly higher than that of deaths (46.3%) (p=0.002).Conclusion:the risk factors for mortality were hemodynamic instability as an indication for laparotomy, presence of solid organ injury, multiple intra-abdominal injuries, need for damage control surgery, serious injury association and low index of trauma score.
Resumo:
Tämä diplomityö on tehty kansainväliseen materiaalinkäsittelyjärjestelmiä toimittavaan yritykseen. Menestyvän yrityksen on pyrittävä kustannustehokkuuden jatkuvaan parantamiseen. Tässä diplomityössä on tutkittu kannattaako kasanpurkaimen portaali valmistaa ristikkorakenteena levyrakenteeseen verrattuna. Tutkimukseen on sisällytetty koko toimitusketju suunnittelusta asennukseen, mutta lujuuslaskennan on suorittanut ulkopuolinen alihankkija. Yrityksen projektissa toimitettiin samaan aikaan purkainta, jonka portaali valmistettiin levyrakenteena. Tätä portaalia on käytetty uuden ristikkorakenteisen portaalin vertailukohtana. Ristikkorakenteinen portaali on suunniteltu putkipalkkirakenteena, jolloin siitä saatiin kevyempi. Suunnittelussa on pyritty huomioimaan valmistusystävällisen suunnittelun näkökohtia, joita esitellään työn teoriaosassa. Ristikkorakenteesta on tehty myös tarjouskuvat, joiden pohjalta valmistustarjoukset on pyydetty. Valmistuskustannusten lisäksi tarkemmassa tarkastelussa ovat suunnittelu- ja laskentakustannukset.
Resumo:
Nykyinen Eurocode 3 suunnitteluohjeen rakenneputkiliitoksia käsittelevä osio vaatii S500 suurlujuusteräksestä valmistettujen liitosten mitoituksen yhteydessä käytettäväksi reduk-tiokerrointa 0.8. Tämä on varsin konservatiivinen mitoituspa, joka vähentää merkittävästi lujemman teräslaadun käyttämisestä saavutettavaa hyötyä. Tämän työn pääasiallinen ta-voite on laboratoriotestein selvittää S500 lujuusluokan rakenneputkiliitosten todellinen äärikapasiteetti ja verrata sitä nykyisen mitoitusohjeen mukaiseen kapasiteettiin. Tässä työssä tutkitut liitokset ovat valmistettu poikkileikkaukseltaan nelikulmaisista kyl-mämuovatuista rakenneputkista. Koesarja koostui kahdeksasta X-liitoksesta, sekä kymme-nestä K-liitoksesta. Kaikki testit suoritettiin huoneenlämmössä, LUT Koneen teräsrakenne-laboratoriossa. Laboratoriotestien lisäksi rakenteen käyttäytymistä tutkittiin epälineaarisen elementtimenetelmän avulla ja näitä tuloksia verrattiin kokeellisiin tuloksiin. Sekä testien että FE–analyysin perusteella voidaan todeta, että S500 lujuusluokan terästä käytettäessä ei Eurocode 3:n mukaisen reduktiokertoimen käytölle ole perusteita.
Resumo:
Tässä kandidaatintyössä vertailtiin SolidWorks Simulations ja Femap FE-analyysiohjelmien tuottamia tuloksia. Vertailu suoritettiin yksinkertaisten RHS-putkipalkkien mallinnuksen avulla. Mallinnuksessa käytettiin viittä erilaista kuormitustapausta, jotka sisälsivät mm. taivutus-, vääntö- ja jännityskeskittymätarkastelut. Ohjelmien tuottamia tuloksia verrattiin mahdollisuuksien mukaan analyyttisin menetelmin tehtyihin vertailulaskelmiin. Työn tarkoituksena oli selvittää tuottivatko eri ohjelmat erilaisia tuloksia samoista kuormitustapauksista ja kuinka paljon tulokset erosivat.
Resumo:
Tässä diplomityössä määritettiin pituussuunnassa hitsatun rakenneputken väsymislujuus HF –hitsausta käytettäessä. Työn tavoitteena oli vertailla eri jälkikäsittelyjen ja kahden eri materiaalin vaikutusta väsymislujuuteen. Materiaaleina kokeissa oli Ruukki double grade ja Optim 700 Plus MH. Eurokoodi 3 ja IIW määrittelee kiinnityshitseille väsymiskestävyysluokaksi 125-140, kun SN -käyrän kaltevuus, m = 3. Koetuloksia vertailtiin näihin valmiiksi määriteltyihin väsymiskestävyysluokkiin. Ruukki Metals Oy toimitti koemateriaalin kahdenlaisia väsytyskokeita varten, joiden avulla väsymislujuus voitiin määrittää. Ensimmäinen koe suoritettiin värähtelyllä hyödyntäen rakenneputken ominaistaajuutta, jolloin kuormituksen rajajännityssuhde on -1. Toinen väsytyskoe suoritettiin rakenneputkista leikatuille väsytyssauvoille, missä pituussuuntainen HF –hitsi on keskellä sauvaa. Tämä väsytyskoe suoritettiin vetotykytyksellä rajajännityssuhteella 0,1. Väsytyskokeissa havaittiin, että kiinnityshitsi täyttää sille asetetut vaatimukset, koska murtumat tapahtuivat perusaineesta. Tällöin koetuloksia vertaillaan Eurokoodi 3:n perusaineen väsymisluokkaan 160, SN -käyrän kaltevuudella m = 5. Kaikkien koetulosten väsymiskestävyysluokan keskiarvoksi saatiin 185 95 %:n todennäköisyydellä. Tutkimuksessa saatiin arvokasta tietoa kahden eri materiaalin väsymislujuudesta. Materiaalilla ei kuitenkaan havaittu vaikutusta lujuuteen. Eri jälkikäsittelyt eli juuren puolen metallipurseen höyläys tai pituussuuntaisen hitsisauman hehkutus eivät vaikuttaneet väsymislujuuteen. Kokeissa väsymismurtuma ydintyi rakenneputken pinnalta olevista alkuvioista, joten putkien käsittelyä valmistuksen jälkeen voitaisiin parantaa.
Resumo:
Today’s electrical machine technology allows increasing the wind turbine output power by an order of magnitude from the technology that existed only ten years ago. However, it is sometimes argued that high-power direct-drive wind turbine generators will prove to be of limited practical importance because of their relatively large size and weight. The limited space for the generator in a wind turbine application together with the growing use of wind energy pose a challenge for the design engineers who are trying to increase torque without making the generator larger. When it comes to high torque density, the limiting factor in every electrical machine is heat, and if the electrical machine parts exceed their maximum allowable continuous operating temperature, even for a short time, they can suffer permanent damage. Therefore, highly efficient thermal design or cooling methods is needed. One of the promising solutions to enhance heat transfer performances of high-power, low-speed electrical machines is the direct cooling of the windings. This doctoral dissertation proposes a rotor-surface-magnet synchronous generator with a fractional slot nonoverlapping stator winding made of hollow conductors, through which liquid coolant can be passed directly during the application of current in order to increase the convective heat transfer capabilities and reduce the generator mass. This doctoral dissertation focuses on the electromagnetic design of a liquid-cooled direct-drive permanent-magnet synchronous generator (LC DD-PMSG) for a directdrive wind turbine application. The analytical calculation of the magnetic field distribution is carried out with the ambition of fast and accurate predicting of the main dimensions of the machine and especially the thickness of the permanent magnets; the generator electromagnetic parameters as well as the design optimization. The focus is on the generator design with a fractional slot non-overlapping winding placed into open stator slots. This is an a priori selection to guarantee easy manufacturing of the LC winding. A thermal analysis of the LC DD-PMSG based on a lumped parameter thermal model takes place with the ambition of evaluating the generator thermal performance. The thermal model was adapted to take into account the uneven copper loss distribution resulting from the skin effect as well as the effect of temperature on the copper winding resistance and the thermophysical properties of the coolant. The developed lumpedparameter thermal model and the analytical calculation of the magnetic field distribution can both be integrated with the presented algorithm to optimize an LC DD-PMSG design. Based on an instrumented small prototype with liquid-cooled tooth-coils, the following targets have been achieved: experimental determination of the performance of the direct liquid cooling of the stator winding and validating the temperatures predicted by an analytical thermal model; proving the feasibility of manufacturing the liquid-cooled tooth-coil winding; moreover, demonstration of the objectives of the project to potential customers.
Resumo:
The use of the Roundup Ready(r) technology and the cultivation of a second crop influence the floristic composition of weed communities in Brazilian Central-West region cropping systems. This study has aimed to diagnose the dominant weed species in southwestern Goiás in areas of genetically-modified and conventional soybeans, using phytosociological and floristic surveys. Weed sampling was obtained by collecting all the plants present within a 0.5 m hollow frame, randomly thrown 20 times in each of thirty-five agricultural areas in the 2012/2013 harvest. Field survey was carried out in three periods: before desiccation for soybean sowing, before postemergence herbicide in soybean first application and before postemergence herbicide application in late harvest. A total of 525 m2 was inventoried and 3,219 weeds were collected, which included 79 species, 58 genera and 28 families. Families Poaceae, Asteraceae, Euphorbiaceae, Fabaceae, Amaranthaceae, were the most representative in the survey. Species Cenchrus echinatus, Glycine max, Chamaesyce hirta, Commelina benghalensis, and Alternanthera tenella stood out in importance. The RR+millet soybean treatment had the highest number of species (44), while the conventional soybean + sorghum treatment had the lowest number of species (18). The highest number of species was recorded in first sampling period. Treatments conventional soybean + maize and conventional soybean + millet showed higher similarity (70%), while treatments RR soybean + millet and conventional soybean + sorghum showed the least (51%). Species of difficult control were recorded in all cultivation systems analyzed.
Resumo:
Työssä on tutkittu laboratoriokokeen ja elementtimenetelmän avulla eri geometrioiden vaikutusta sekundääriseen momentin syntymiseen K-liitoksella. Kokeen liitos on tehty S700-lujuusluokan Ruukin Optim 700 plus MH nelikulmaisista rakenneputkista (RHS). Elementtimalleissa on käytetty geometrista ja materiaalista epälineaarisuutta ennustamaan liitoksen muodonmuutoskykyä ja laskennallista kestävyyttä. Liitoksen elementtimalleissa muutettavia geometrioita ovat: vapaaväli, uumasauvan ja paarteen välinen kulma, paarteen seinämän paksuus, liitoksen eksentrisyys ja uumasauvan ja paarteen leveyden suhde. Laboratoriokokeen liitoksen vetouumasauvassa vaikuttava sekundäärisen momentin aiheuttama jännitys on noin 25 % vetouumasauvan myötörajasta. Suurin sekundäärinen momentti syntyy, kun vapaaväliä pienennetään ja uumasauvaa kavennetaan paarteeseen nähden. Eurocode 3:n mitoitusohjeita voidaan elementtimallien perusteella soveltaa tietyille geometrioille turvallisesti.
Resumo:
Työssä tutkittiin mahdollisuutta tehostaa kunnallista jätevedenpuhdistusta membraanitekniikkaa käyttäen. Teoriaosassa perehdyttiin kunnallisen jäteveden omi-naisuuksiin ja perinteiseen puhdistusprosessiin. Tämän lisäksi membraanien yleisiä ominaisuuksia, membraanityyppien kykyä erottaa jäteveden sisältämiä yhdisteitä sekä erilaisia mahdollisuuksia membraanisuodatukselle perinteisen jäteve-denpuhdistusprosessin yhteydessä käytiin läpi. Kokeellisessa osassa keskityttiin Savitaipaleen puhdistamon puhdistetun jäteveden laadun parantamiseen membraanisuodatukseen perustuvalla jälkikäsittely-yksiköllä eli tertiäärisuodatuksella. Erilaisia paineavusteisia membraanitekniikoita (MF, UF, NF ja RO) tutkittiin jäteveden puhdistamiseksi ja erotustehokkuuden vertailemiseksi. Tavoitteena oli löytää tehokas ja käytännössä toimiva tapa poistaa fosforia ja typpeä puhdistetusta jätevedestä. Tasomaisilla membraaneilla tehdyissä suodatuksissa MF-membraanit poistivat tehokkaasti fosforia (97 – 98 %) sekä kiintoainesta (100 %) jätevedestä. RO-membraanit alensivat fosfori- (100 %) ja typpipitoisuutta (90 – 94 %) tehokkaasti, poistaen myös liuenneita orgaanisia yhdisteitä (DOC, 90 – 94 %). Mikrosuodatukseen perustuvilla onttokuitumembraaneilla saavutettiin tehokkaan fosforinpoiston lisäksi tasainen kapasiteetti suodatuksen aikaista puhdistusmene-telmää optimoimalla. Pitoisuusalenemat olivat myös erittäin korkeita fosforille (97 – 99 %), kiintoaineelle (100 %), sameudelle (96 – 99 %) sekä COD:lle (38 – 55 %). Tulosten perusteella membraanitekniikkaan perustuva onttokuitusuodatus olisi tehokas ja toimiva jälkikäsittelyprosessi fosforinpoistoon ja jäteveden laadun pa-rantamiseen. Typen poistamiseen parhaiten toimi RO-membraani.
Resumo:
Double grade S420MH/S355J2H – rakenneputki on Ruukin kylmämuovattujen rakenneputkien vakioteräslaji. Se voidaan mitoittaa joko lujuusluokan S355 tai S420 mukaisesti. Teräslajin S355 mukaisesti mitoitettaessa on suunnittelu yksinkertaista. Painonsäästöä ja pidennettyjä jännevälejä haluttaessa käytetään lujuusluokan S420 mukaista mitoitusta. Työn tavoitteena oli selvittää kylmämuovattujen teräsrakenneputkien todellinen puristuskestävyys. Eurocode 3:n mukaan kylmämuovatut teräsrakenneputket kuuluvat nurjahduskäyrälle c. Tutkimukseen valittiin viisi eri profiilia olevaa rakenneputkea, joiden poikkileikkausluokat olivat 1, 2, 3 ja 4. Käytettäessä rakenneputkia puristussauvoina, on teräksen käyttö tehokkainta poikkileikkausluokassa 3, lähellä poikkileikkausluokkaa 4. Rakenneputkista laskettiin muunnetun hoikkuuden arvoilla 0.1, 0.5, 1.0 ja 1.5 koesauvojen pituudet kaikille profiileille. Valmistettiin kolme samanlaista koesauvaa jokaisesta koosta ja puristuskokeita suoritettiin yhteensä 57 kappaletta. Koesauvojen todelliset pituudet, alkukäyryydet ja poikkileikkaukset mitattiin. Ainestodistuksista saatiin materiaalin todelliset lujuudet. Laskettiin Eurocode 3:n mukaisesti kestävyydet nurjahduskäyrille a, b ja c. Laskennallisia kestävyyksiä verrattiin puristuskokeiden tuloksiin. Puristuskokeiden tulosten perusteella voidaan b-käyrää pitää oikeana profiileille 100x100x3, 150,150x5 ja 200x200x6. Profiili 150x150x5 kuuluu poikkileikkausluokkaan 2. Profiilit 100x100x3 ja 200x200x6 kuuluvat poikkileikkausluokkaan 4. Profiili 50x50x2 kuuluu nurjahduskäyrälle c. Profiilin poikkileikkausluokka on 1 ja aiemmat tutkimukset tukevat nurjahduskäyrän c käyttöä. Profiilista 300x300x8.8 ei saatu testattua täyttä sarjaa sen suuren kapasiteetin rikottua testilaitteiston, mutta puristuskokeiden perusteella se kuuluu nurjahduskäyrälle b. Profiili kuuluu poikkileikkausluokkaan 4.
Resumo:
Evaluation of HIV-induced IL-2 production by peripheral blood mononuclear cells (PBMC) and HIV-specific T helper and cytotoxic T lymphocyte (CTL) responses in health care workers (HCW) occupationally exposed to HIV reveals a high rate of response to HIV among non-seroconverters. IL-10 is also known to interfere with HIV infection in vitro. To evaluate the induction of IL-10 by HIV antigens in HCW occupationally exposed to HIV, 18 HCW with percutaneous injury were enrolled in this study, 9 of them exposed to HIV-contaminated blood, and 9 exposed to HIV-negative blood. PBMC were incubated on plates coated with HIV-1 antigens, and IL-10 was measured in supernatants by ELISA. Five of nine HCW exposed to HIV-contaminated blood presented HIV-induced IL-10. Two of nine HCW exposed to HIV-negative source patients also had detectable levels of HIV-induced IL-10, one of them in the sample obtained on the day of accidental exposure. There was a relationship between the type of device involved in injury and IL-10 production. Individuals exposed to hollow needles or scalpels presented HIV-induced IL-10, whereas those exposed to solid needles and to digital puncture did not, suggesting a relationship between infectious load and IL-10. Although occupational exposure to HIV leads to a low rate of seroconversion, these individuals can develop an antigen-specific immune response characterized in our study by induction of IL-10 in PBMC in vitro.
Resumo:
The distribution of the aflatoxin contamination was studied among four maize fractions, separated according to Brazilian grading rules for maize. The fraction that contained fermented, moldy, heated and sprouted grains normally had the highest levels of aflatoxin. However, the fraction contribution to the whole sample contamination level took into account the contamination fraction level and its weight to the whole sample. Considering this, the fraction that contained insect damaged, hollow, up to ¼ fermented and grains damaged by other causes was normally the fraction responsible for the total contamination level in the samples. Nevertheless, the fraction contributions were variable from sample to sample. Therefore, in conclusion, it was not possible to establish a standard behavior for grain fraction-type contribution for different maize lots. The Brazilian grading by qualitative types applied to samples did not show statistic correlation with aflatoxin contamination levels (P<0.05). Two type-1 samples (the best quality type) presented contamination of 380 and 146ng/g. The number of samples with contamination levels above those allowed by Brazilian law (20ng/g) was the same for qualitative types 2, 3, and BS (Below Standard).
Resumo:
West Indian cherry (Malpighia glabra L.) and pineapple (Ananas comosus (L.) Meer)juice clarification by cross-flow UF, using polysulphone hollow fiber and ceramic tubular membranes with, respectively, nominal molecular weight cut off values of 100kDaltons and average pore diameters of 0.01mm, were studied. The influence of enzymatic treatment using enzyme concentrations of 20, 100 and 300mg/L, a time of 90min and a temperature of 40ºC for depectinization was verified. The juices were then clarified in a laboratory scale filtration unit, with an effective filtration area of 0.12m² for the polysulphone hollow fiber membrane and of 0.005m² for the ceramic tubular membranes. The influence of enzymatic treatment on viscosity, turbidity and total pectin of the juice, before ultrafiltration, is reported. Membrane performance was evaluated in terms of flow rate and clarity of the permeate. The permeate flow rate of depectinized pineapple juice was higher (30 - 60%) for both membranes. Depectinized West Indian cherry juice presented a lower permeate flow rate for the polysulphone hollow fiber membrane. The increase in permeate flow rate, with the use of the 300mg/L and 100mg/L enzyme concentration was not significant, so it is economically advantageous to ultrafilter depectinized juice, treated with an enzyme concentration of 20mg/L.
Resumo:
Wind is one of the most compelling forms of indirect solar energy. Available now, the conversion of wind power into electricity is and will continue to be an important element of energy self-sufficiency planning. This paper is one in a series intended to report on the development of a new type of generator for wind energy; a compact, high-power, direct-drive permanent magnet synchronous generator (DD-PMSG) that uses direct liquid cooling (LC) of the stator windings to manage Joule heating losses. The main param-eters of the subject LC DD-PMSG are 8 MW, 3.3 kV, and 11 Hz. The stator winding is cooled directly by deionized water, which flows through the continuous hollow conductor of each stator tooth-coil winding. The design of the machine is to a large degree subordinate to the use of these solid-copper tooth-coils. Both steady-state and timedependent temperature distributions for LC DD-PMSG were examined with calculations based on a lumpedparameter thermal model, which makes it possible to account for uneven heat loss distribution in the stator conductors and the conductor cooling system. Transient calculations reveal the copper winding temperature distribution for an example duty cycle during variable-speed wind turbine operation. The cooling performance of the liquid cooled tooth-coil design was predicted via finite element analysis. An instrumented cooling loop featuring a pair of LC tooth-coils embedded in a lamination stack was built and laboratory tested to verify the analytical model. Predicted and measured results were in agreement, confirming the predicted satisfactory operation of the LC DD-PMSG cooling technology approach as a whole.