879 resultados para Hearing Loss, Noise-Induced
Resumo:
Introduction: Description for using stethoscopes adapted to hearing aids. Aim: To describe the adaptation of HAs to stethoscopes used by 2 students in the health field with bilateral hearing impairment. Case reports: Two subjects with hearing loss had their stethoscopes coupled to HAs because of the individual requirements of their professions (healthcare) to perform auscultation. Conclusion: The improvement was measured in situ, and satisfaction was evaluated using a subjective questionnaire. The use of a stethoscope coupled to an HA allowed students with hearing loss to perform auscultation.
Resumo:
Purpose: To characterize the profile of patients with cochlear implant as proposed by the International Classification of Functioning, Disability and Health for Children and Youth (ICF-CY). Methods: This is a descriptive, crosssectional retrospective study, which examined 30 medical records of patients using the cochlear implant of Centro de Pesquisas Audiológicas. To characterize the profile of the patients, the ICF-CY was used. Regarding the assessment, researchers relied on procedures performed in clinical routine, besides information registered in the medical record. After reviewing the information, it was related to codes from the ICF-CY; with the addition of a qualifier afterwards. Results: Overall, 55 codes from the ICF were related to the instruments to characterize this population. Regarding the Body Functions field, most participants did not have disabilities related to reception and expression of oral language and auditory functions, with only written language disabilities being found. These same findings were observed in the Activity and Participation Field. Regarding environmental factors, noise and the non-availability of technology resources to assist in the auditory comprehension of noise were characterized as a barrier, as well as the absence of speech therapy. Conclusion: This study concluded that most of the participating children showed no deficiency in the body functions, with difficulties being only reported in relation to school performance. Environmental factors (noise, non-availability of technological resources, absence of speech therapy) were characterized as a barrier. The need to expand assessments in the clinical routine was also noted.
Resumo:
OBJECTIVE: To portray the family experience when the discovery of hearing impairment in their child. METHODS: Qualitative research with Symbolic Interactionism and Grounded Theory as theoretical and methodological frameworks. Data collection instrument: semi-structured interview. The study included nine families (32 participants). RESULTS: The theme, "Seeing an idealized future collapse", shows that for the family, discovered the possibility of having a child with hearing loss is a moment that involves many negative feelings. CONCLUSION: Discover the hearing loss has a meaning of the expected loss of the perfect child, frustrated expectations and uncertain future. The family has been inadequately approached and the diagnosis has been made late, which requires immediate changes to the practices of professionals.
Resumo:
INTRODUÇÃO: O BAHA (Bone Ancored Hearing Aid) é um dispositivo auditivo de condução óssea que propaga o som diretamente à orelha interna, utilizado principalmente em pacientes com perda auditiva condutiva associada a atresia aural, mas atualmente também em perdas mistas e neurossensoriais. OBJETIVO: Revisar as principais indicações do BAHA, analisar os resultados audiométricos e os benefícios proporcionados aos pacientes, e compará-los com outras modalidades de tratamento além de comparar os dados da literatura com nossa casuística de 13 pacientes. MÉTODO: A pesquisa foi realizada em bases de dados abrangendo trabalhos em inglês, espanhol e português, sem limites de intervalos de anos, comparando com os resultados dos nossos 13 pacientes submetidos a esse procedimento, no período de 2000 a 2009. RESULTADOS: A maioria dos trabalhos mostrou vantagens do BAHA em comparação à cirurgia reconstrutiva, tanto pelos resultados audiológicos quanto em relação a complicações e recidiva. Os resultados pós-operatórios nos 13 pacientes operados por nossa equipe foi satisfatório e compatível com os da literatura, com fechamento do gap aéreo-ósseo em 7 pacientes e gap aéreo-ósseo de até 10 dB em 6 pacientes. Não houve complicações pós-operatórias. CONCLUSÃO: O BAHA é uma ótima opção de tratamento para pacientes com surdez condutiva bilateral, fato demonstrado pelos bons resultados audiológicos e por se tratar de um procedimento cirúrgico relativamente simples e com baixa taxa de complicações. Os estudos mais recentes vêm abordando seu uso para surdez condutiva e neurossensorial unilateral.
Resumo:
OBJETIVO: Verificar a aplicabilidade de um software na (re)habilitação de crianças com deficiência auditiva. MÉTODOS: A amostra foi composta por 17 crianças com deficiência auditiva, sendo dez usuárias de Implante Coclear (IC) e sete usuárias de Aparelho de Amplificação Sonora Individual (AASI). Foi utilizado o "Software Auxiliar na Reabilitação de Distúrbios Auditivos (SARDA)". Aplicou-se o protocolo de treinamento durante 30 minutos, duas vezes por semana, pelo tempo necessário para a finalização das estratégias que compõe software. Para mensurar a aplicabilidade do software no treinamento da habilidade de percepção da fala no silêncio e no ruído, foram realizadas avaliações com o Hearing in Noise Test (HINT) pré e pós o treinamento auditivo. Os dados foram analisados estatisticamente. RESULTADOS: O grupo de usuários de IC necessitou em média 12,2 dias para finalizar as estratégias e o grupo de usuários de AASI em média 10,14 dias. Os dois grupos apresentaram diferença entre as avaliações pré e pós no silêncio e no ruído. As crianças mais novas apresentaram maior dificuldade durante a execução das estratégias, porém não houve correlação entre a idade e o desempenho. Não houve influência do tipo do dispositivo eletrônico durante o treinamento. As crianças apresentaram maior dificuldade na estratégia que envolvia estímulos não verbais e na estratégia com estímulos verbais que treina a habilidade de atenção sustentada. A atenção e a motivação da criança durante a estimulação foram fundamentais para o bom rendimento do treinamento auditivo. CONCLUSÃO: O treinamento auditivo com o SARDA foi eficaz, pois propiciou melhora na habilidade de percepção da fala, no silêncio e no ruído, das crianças com deficiência auditiva.
Resumo:
OBJETIVO: Avaliar a eficácia da teleconsulta para a programação, verificação e adaptação do aparelho de amplificação sonora individual (AASI). MÉTODOS: Cinquenta participantes com deficiência auditiva (idades entre 39 e 88 anos), com média dos limiares audiométricos entre 30 e 68,75 dBNA, foram alocados em dois grupos (randomização estratificada), controle (n=25) e experimental (n=25), submetidos respectivamente à consulta face a face e teleconsulta síncrona com video interativo e controle remoto de aplicativos. Foram realizadas a programação e verificação do AASI (medidas com microfone sonda) e orientação dos participantes quanto ao uso e cuidados com o dispositivo. O tempo para os procedimentos foi cronometrado. Após as consultas um avaliador, cego quanto aos grupos, aplicou o teste de percepção da fala Hearing in Noise Test (HINT) Brasil. Aproximadamente um mês após as consultas, foi verificado o tempo diário de uso do AASI e administrado o questionário International Outcome Inventory for Hearing Aids (IOI-HA). RESULTADOS: Maior tempo para a programação e verificação e menor tempo para orientação foi observado para o grupo experimental. Não houve diferença entre grupos no tempo total do atendimento. A equiparação das medidas com microfone sonda aos respectivos targets de amplificação foi similar para os dois grupos. Não houve diferença entre os grupos quanto aos resultados do HINT-Brasil (silêncio e ruído), o tempo médio de uso diário do AASI e resultados do IOI-HA. CONCLUSÃO: A teleconsulta é um procedimento eficaz para a programação, verificação do AASI e orientação de usuários quando serviços face a face não estiverem disponíveis.
Resumo:
OBJECTIVE: To identify the prevalence of hearing loss for the population in the urban area. METHODS: A cross-sectional household survey based on the World Health Organization Ear and Hearing Disorders Survey Protocol was conducted in 298 households in the urban area of Monte Negro, Rondonia, Northern Brazil, from 2005 to 2007. Ear examinations, behavioral audiometry and pure tone audiometry were conducted on 577 individuals. RESULTS: The results showed that 3.8% (95%CI 2.17;5.45) of population were classifi ed in the disabling hearing impairment category. The prevalence of moderate hearing impairment was 3.4%; severe impairment was 0.4%; and profound hearing impairment was not found. CONCLUSIONS: The impairing hearing loss prevalence found in this study is within of the international prevalence for this level of hearing loss and smaller than observed in a previous study in the South region of Brazil.
Resumo:
I tumori macroscopici e microscopici, dopo la loro prima fase di crescita, sono composti da un numero medio elevato di cellule. Così, in assenza di perturbazioni esterne, la loro crescita e i punti di equilibrio possono essere descritti da equazioni differenziali. Tuttavia, il tumore interagisce fortemente col macroambiente che lo circonda e di conseguenza una descrizione del tutto deterministica risulta a volte inappropriata. In questo caso si può considerare l'interazione con fluttuazioni statistiche, causate da disturbi esterni, utilizzando le equazioni differenziali stocastiche (SDE). Questo è vero in modo particolare quando si cerca di modellizzare tumori altamente immunogenici che interagiscono con il sistema immunitario, in quanto la complessità di questa interazione risulta in fenomeni di multistabilità. Così, il rumore può provocare disturbi e indurre transizioni di stato (Noise-Induced-Transitions). E' importante notare che una NIT può avere implicazioni profonde sulla vita di un paziente, dal momento che una transizione da uno stato di equilibrio piccolo, nelle dimensioni del tumore, ad uno stato di equilibrio macroscopico, nella maggior parte dei casi significa il passaggio dalla vita alla morte. Generalmente l'approccio standard è quello di modellizzare le fluttuazioni stocastiche dei parametri per mezzo di rumore gaussiano bianco o colorato. In alcuni casi però questa procedura è altamente inadeguata, a causa della illimitatezza intrinseca dei rumori gaussiani che può portare a gravi incongruenze biologiche: pertanto devono essere utilizzati dei rumori "limitati", che, tuttavia, sono molto meno studiati di quelli gaussiani. Inoltre, l'insorgenza di NIT dipende dal tipo di rumore scelto, che rivela un nuovo livello di complessità in biologia. Lo scopo di questa tesi è quello di studiare le applicazioni di due tipi diversi di "rumori limitati" nelle transizioni indotte in due casi: interazione tra tumore e sistema immunitario e chemioterapia dei tumori. Nel primo caso, abbiamo anche introdotto un nuovo modello matematico di terapia, che estende, in modo nuovo, il noto modello di Norton-Simon.
Resumo:
A new hearing therapy based on direct acoustic cochlear stimulation was developed for the treatment of severe to profound mixed hearing loss. The device efficacy was validated in an initial clinical trial with four patients. This semi-implantable investigational device consists of an externally worn audio processor, a percutaneous connector, and an implantable microactuator. The actuator is placed in the mastoid bone, right behind the external auditory canal. It generates vibrations that are directly coupled to the inner ear fluids and that, therefore, bypass the external and the middle ear. The system is able to provide an equivalent sound pressure level of 125 dB over the frequency range between 125 and 8000 Hz. The hermetically sealed actuator is designed to provide maximal output power by keeping its dimensions small enough to enable implantation. A network model is used to simulate the dynamic characteristics of the actuator to adjust its transfer function to the characteristics of the middle ear. The geometry of the different actuator components is optimized using finite-element modeling.
Resumo:
This review covers the surgery for the bone-anchored hearing aid (Baha(®)). PREOPERATIVE WORKUP: A review of the indications and preoperative diagnostics shows that best results are generally obtained in patients with conductive or mixed hearing loss rehabilitation when surgery is not applicable or has failed and in patients that suffer from single-sided deafness. An audiogram must confirm that the bone conduction hearing is within the inclusion criteria. A computed tomography scan is performed in cases of malformation to assure sufficient bone thickness at the site of screw implantation.
Resumo:
We characterized changes in the visual behavior of mice in which a loss of the retinal pigment epithelium (RPE) was experimentally induced with intravenous (i.v.) administration of sodium iodate (NaIO3). We compared and correlated these changes with alterations in neural retinal structure and function. RPE loss was induced in 4-6 week old male C57BL/6 mice with an i.v. injection of 1% NaIO3 at three concentrations: 35, 50, or 70 mg/kg. At 1, 3, 7, 14, 21, and 28 days (d) as well as 6 months post injection (PI) a behavioral test was performed in previously trained mice to evaluate visual function. Eye morphology was then assessed for changes in both the RPE and neural retina. NaIO3-induced RPE degeneration was both dose and PI time dependent. Our low dose showed no effects, while our high dose caused the most damage, as did longer PI times at our intermediate dose. Using the intermediate dose, no changes were detectable in either visual behavior or retinal morphology at 1 d PI. However, at 3 d PI visual behavior became abnormal and patchy RPE cell loss was observed. From 7 d PI onward, changes in retinal morphology and visual behavior became more severe. At 6 months PI, no recovery was seen in any of these measures in mice administered the intermediate dose. These results show that NaIO3 dosage and/or time PI can be varied to produce different, yet permanent deficits in retinal morphology and visual function. Thus, this approach should provide a unique system in which the onset and severity of RPE damage, and its consequences can be manipulated. As such, it should be useful in the assessment of rescue or mitigating effects of retinal or stem cell transplantation on visual function.
Resumo:
A new implantable hearing system, the direct acoustic cochlear stimulator (DACS) is presented. This system is based on the principle of a power-driven stapes prosthesis and intended for the treatment of severe mixed hearing loss due to advanced otosclerosis. It consists of an implantable electromagnetic transducer, which transfers acoustic energy directly to the inner ear, and an audio processor worn externally behind the implanted ear. The device is implanted using a specially developed retromeatal microsurgical approach. After removal of the stapes, a conventional stapes prosthesis is attached to the transducer and placed in the oval window to allow direct acoustical coupling to the perilymph of the inner ear. In order to restore the natural sound transmission of the ossicular chain, a second stapes prosthesis is placed in parallel to the first one into the oval window and attached to the patient's own incus, as in a conventional stapedectomy. Four patients were implanted with an investigational DACS device. The hearing threshold of the implanted ears before implantation ranged from 78 to 101 dB (air conduction, pure tone average, 0.5-4 kHz) with air-bone gaps of 33-44 dB in the same frequency range. Postoperatively, substantial improvements in sound field thresholds, speech intelligibility as well as in the subjective assessment of everyday situations were found in all patients. Two years after the implantations, monosyllabic word recognition scores in quiet at 75 dB improved by 45-100 percent points when using the DACS. Furthermore, hearing thresholds were already improved by the second stapes prosthesis alone by 14-28 dB (pure tone average 0.5-4 kHz, DACS switched off). No device-related serious medical complications occurred and all patients have continued to use their device on a daily basis for over 2 years. Copyright (c) 2008 S. Karger AG, Basel.
Resumo:
OBJECTIVE: To investigate correlations between preoperative hearing thresholds and postoperative aided thresholds and speech understanding of users of Bone-anchored Hearing Aids (BAHA). Such correlations may be useful to estimate the postoperative outcome with BAHA from preoperative data. STUDY DESIGN: Retrospective case review. SETTING: Tertiary referral center. PATIENTS:: Ninety-two adult unilaterally implanted BAHA users in 3 groups: (A) 24 subjects with a unilateral conductive hearing loss, (B) 38 subjects with a bilateral conductive hearing loss, and (C) 30 subjects with single-sided deafness. INTERVENTIONS: Preoperative air-conduction and bone-conduction thresholds and 3-month postoperative aided and unaided sound-field thresholds as well as speech understanding using German 2-digit numbers and monosyllabic words were measured and analyzed. MAIN OUTCOME MEASURES: Correlation between preoperative air-conduction and bone-conduction thresholds of the better and of the poorer ear and postoperative aided thresholds as well as correlations between gain in sound-field threshold and gain in speech understanding. RESULTS: Aided postoperative sound-field thresholds correlate best with BC threshold of the better ear (correlation coefficients, r2 = 0.237 to 0.419, p = 0.0006 to 0.0064, depending on the group of subjects). Improvements in sound-field threshold correspond to improvements in speech understanding. CONCLUSION: When estimating expected postoperative aided sound-field thresholds of BAHA users from preoperative hearing thresholds, the BC threshold of the better ear should be used. For the patient groups considered, speech understanding in quiet can be estimated from the improvement in sound-field thresholds.
Radiological factors related to pre-operative hearing levels in patients with vestibular schwannomas
Resumo:
The pathogenetic mechanism of hearing loss in patients with vestibular schwannomas (VS) remains unclear. Our aim was to determine the radiological and clinical parameters that might be related to hearing. The radiological images and charts of 99 patients were reviewed. Image processing software was used to analyse the maximal tumor diameter in three planes; its volume; its extension cranially, caudally, anteriorly and posteriorly; the width and length of the intrameatal tumor portion, its shape and consistency; and the tumor-fundus distance. These parameters were correlated with the patient's pre-operative hearing range. The degree of hearing correlated significantly with the tumor size, volume and coronal diameter, the degree of intrameatal tumor growth, and the distance between the lateral tumor end and the fundus (p < 0.05). No correlation was found regarding tumor extension, shape and consistency, the presence of hydrocephalus, or the extent of erosion of the internal auditory canal. Loss of hearing in the VS appears to be multifactorial. Determining the radiological parameters related to the hearing level can help to clarify the pathophysiological mechanisms involved.
Resumo:
Objective: To investigate objective and subjective effects of an adjunctive contralateral routing of signal (CROS) device at the untreated ear in patients with a unilateral cochlear implant (CI). Design: Prospective study of 10 adult experienced unilateral CI users with bilateral severe-to-profound hearing loss. Speech in noise reception (SNR) and sound localization were measured with and without the additional CROS device. SNR was measured by applying speech signals at the untreated/CROS side while noise signals came from the front (S90N0). For S0N90, signal sources were switched. Sound localization was measured in a 12-loudspeaker full circle setup. To evaluate the subjective benefit, patients tried the device for 2 weeks at home, then filled out the abbreviated Speech, Spatial and Qualities of Hearing Scale as well as the Bern benefit in single-sided deafness questionnaires. Results: In the setting S90N0, all patients showed a highly significant SNR improvement when wearing the additional CROS device (mean 6.4 dB, p < 0.001). In the unfavorable setting S0N90, only a minor deterioration of speech understanding was noted (mean -0.66 dB, p = 0.54). Sound localization did not improve substantially with CROS. In the two questionnaires, 12 of 14 items showed an improvement in mean values, but none of them was statistically significant. Conclusion: Patients with unilateral CI benefit from a contralateral CROS device, particularly in a noisy environment, when speech comes from the CROS ear side. © 2014 S. Karger AG, Basel.