932 resultados para Garrett (Ill.)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

CONTEXT: Determination of arginine vasopressin (AVP) concentrations may be helpful to guide therapy in critically ill patients. A new assay analyzing copeptin, a stable peptide derived from the AVP precursor, has been introduced. OBJECTIVE: Our objective was to determine plasma copeptin concentrations. DESIGN: We conducted a post hoc analysis of plasma samples and data from a prospective study. SETTING: The setting was a 12-bed general and surgical intensive care unit (ICU) in a tertiary university teaching hospital. PATIENTS: Our subjects were 70 healthy volunteers and 157 ICU patients with sepsis, with systemic inflammatory response syndrome (SIRS), and after cardiac surgery. INTERVENTIONS: There were no interventions. MAIN OUTCOME MEASURES: Copeptin plasma concentrations, demographic data, AVP plasma concentrations, and a multiple organ dysfunction syndrome score were documented 24 h after ICU admission. RESULTS: AVP (P < 0.001) and copeptin (P < 0.001) concentrations were significantly higher in ICU patients than in controls. Patients after cardiac surgery had higher AVP (P = 0.003) and copeptin (P = 0.003) concentrations than patients with sepsis or SIRS. Independent of critical illness, copeptin and AVP correlated highly significantly with each other. Critically ill patients with sepsis and SIRS exhibited a significantly higher ratio of copeptin/AVP plasma concentrations than patients after cardiac surgery (P = 0.012). The American Society of Anesthesiologists' classification (P = 0.046) and C-reactive protein concentrations (P = 0.006) were significantly correlated with the copeptin/AVP ratio. CONCLUSIONS: Plasma concentrations of copeptin and AVP in healthy volunteers and critically ill patients correlate significantly with each other. The ratio of copeptin/AVP plasma concentrations is increased in patients with sepsis and SIRS, suggesting that copeptin may overestimate AVP plasma concentrations in these patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article is a systematic review of whether everyday exposure to radiofrequency electromagnetic field (RF-EMF) causes symptoms, and whether some individuals are able to detect low-level RF-EMF (below the ICNIRP [International Commission on Non-Ionizing Radiation Protection] guidelines). Peer-reviewed articles published before August 2007 were identified by means of a systematic literature search. Meta-analytic techniques were used to pool the results from studies investigating the ability to discriminate active from sham RF-EMF exposure. RF-EMF discrimination was investigated in seven studies including a total of 182 self-declared electromagnetic hypersensitive (EHS) individuals and 332 non-EHS individuals. The pooled correct field detection rate was 4.2% better than expected by chance (95% CI: -2.1 to 10.5). There was no evidence that EHS individuals could detect presence or absence of RF-EMF better than other persons. There was little evidence that short-term exposure to a mobile phone or base station causes symptoms based on the results of eight randomized trials investigating 194 EHS and 346 non-EHS individuals in a laboratory. Some of the trials provided evidence for the occurrence of nocebo effects. In population based studies an association between symptoms and exposure to RF-EMF in the everyday environment was repeatedly observed. This review showed that the large majority of individuals who claims to be able to detect low level RF-EMF are not able to do so under double-blind conditions. If such individuals exist, they represent a small minority and have not been identified yet. The available observational studies do not allow differentiating between biophysical from EMF and nocebo effects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Sedative and analgesic drugs are frequently used in critically ill patients. Their overuse may prolong mechanical ventilation and length of stay in the intensive care unit. Guidelines recommend use of sedation protocols that include sedation scores and trials of sedation cessation to minimize drug use. We evaluated processed electroencephalography (response and state entropy and bispectral index) as an adjunct to monitoring effects of commonly used sedative and analgesic drugs and intratracheal suctioning. METHODS: Electrodes for monitoring bispectral index and entropy were placed on the foreheads of 44 critically ill patients requiring mechanical ventilation and who previously had no brain dysfunction. Sedation was targeted individually using the Ramsay Sedation Scale, recorded every 2 hours or more frequently. Use of and indications for sedative and analgesic drugs and intratracheal suctioning were recorded manually and using a camera. At the end of the study, processed electroencephalographical and haemodynamic variables collected before and after each drug application and tracheal suctioning were analyzed. Ramsay score was used for comparison with processed electroencephalography when assessed within 15 minutes of an intervention. RESULTS: The indications for boli of sedative drugs exhibited statistically significant, albeit clinically irrelevant, differences in terms of their association with processed electroencephalographical parameters. Electroencephalographical variables decreased significantly after bolus, but a specific pattern in electroencephalographical variables before drug administration was not identified. The same was true for opiate administration. At both 30 minutes and 2 minutes before intratracheal suctioning, there was no difference in electroencephalographical or clinical signs in patients who had or had not received drugs 10 minutes before suctioning. Among patients who received drugs, electroencephalographical parameters returned to baseline more rapidly. In those cases in which Ramsay score was assessed before the event, processed electroencephalography exhibited high variation. CONCLUSIONS: Unpleasant or painful stimuli and sedative and analgesic drugs are associated with significant changes in processed electroencephalographical parameters. However, clinical indications for drug administration were not reflected by these electroencephalographical parameters, and barely by sedation level before drug administration or tracheal suction. This precludes incorporation of entropy and bispectral index as target variables for sedation and analgesia protocols in critically ill patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Neurally adjusted ventilatory assist (NAVA) delivers assist in proportion to the patient's respiratory drive as reflected by the diaphragm electrical activity (EAdi). We examined to what extent NAVA can unload inspiratory muscles, and whether unloading is sustainable when implementing a NAVA level identified as adequate (NAVAal) during a titration procedure. METHODS: Fifteen adult, critically ill patients with a Pao(2)/fraction of inspired oxygen (Fio(2)) ratio < 300 mm Hg were studied. NAVAal was identified based on the change from a steep increase to a less steep increase in airway pressure (Paw) and tidal volume (Vt) in response to systematically increasing the NAVA level from low (NAVAlow) to high (NAVAhigh). NAVAal was implemented for 3 h. RESULTS: At NAVAal, the median esophageal pressure time product (PTPes) and EAdi values were reduced by 47% of NAVAlow (quartiles, 16 to 69% of NAVAlow) and 18% of NAVAlow (quartiles, 15 to 26% of NAVAlow), respectively. At NAVAhigh, PTPes and EAdi values were reduced by 74% of NAVAlow (quartiles, 56 to 86% of NAVAlow) and 36% of NAVAlow (quartiles, 21 to 51% of NAVAlow; p < or = 0.005 for all). Parameters during 3 h on NAVAal were not different from parameters during titration at NAVAal, and were as follows: Vt, 5.9 mL/kg predicted body weight (PBW) [quartiles, 5.4 to 7.2 mL/kg PBW]; respiratory rate (RR), 29 breaths/min (quartiles, 22 to 33 breaths/min); mean inspiratory Paw, 16 cm H(2)O (quartiles, 13 to 20 cm H(2)O); PTPes, 45% of NAVAlow (quartiles, 28 to 57% of NAVAlow); and EAdi, 76% of NAVAlow (quartiles, 63 to 89% of NAVAlow). Pao(2)/Fio(2) ratio, Paco(2), and cardiac performance during NAVAal were unchanged, while Paw and Vt were lower, and RR was higher when compared to conventional ventilation before implementing NAVAal. CONCLUSIONS: Systematically increasing the NAVA level reduces respiratory drive, unloads respiratory muscles, and offers a method to determine an assist level that results in sustained unloading, low Vt, and stable cardiopulmonary function when implemented for 3 h.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: The paucity of data on resource use in critically ill patients with hematological malignancy and on these patients' perceived poor outcome can lead to uncertainty over the extent to which intensive care treatment is appropriate. The aim of the present study was to assess the amount of intensive care resources needed for, and the effect of treatment of, hemato-oncological patients in the intensive care unit (ICU) in comparison with a nononcological patient population with a similar degree of organ dysfunction. METHODS: A retrospective cohort study of 101 ICU admissions of 84 consecutive hemato-oncological patients and 3,808 ICU admissions of 3,478 nononcological patients over a period of 4 years was performed. RESULTS: As assessed by Therapeutic Intervention Scoring System points, resource use was higher in hemato-oncological patients than in nononcological patients (median (interquartile range), 214 (102 to 642) versus 95 (54 to 224), P < 0.0001). Severity of disease at ICU admission was a less important predictor of ICU resource use than necessity for specific treatment modalities. Hemato-oncological patients and nononcological patients with similar admission Simplified Acute Physiology Score scores had the same ICU mortality. In hemato-oncological patients, improvement of organ function within the first 48 hours of the ICU stay was the best predictor of 28-day survival. CONCLUSION: The presence of a hemato-oncological disease per se is associated with higher ICU resource use, but not with increased mortality. If withdrawal of treatment is considered, this decision should not be based on admission parameters but rather on the evolutional changes in organ dysfunctions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Treatment of central and paracentral pulmonary embolism in patients with hemodynamic compromise remains a subject of debate, and no consensus exists regarding the best method: thrombolytic agents, catheter-based thrombus aspiration or fragmentation, or surgical embolectomy. We reviewed our experience with emergency surgical pulmonary embolectomy. METHODS: Between January of 2000 and March of 2007, 25 patients (17 male, mean age 60 years) underwent emergency open embolectomy for central and paracentral pulmonary embolism. Eighteen patients presented in cardiogenic shock, 8 of whom had cardiac arrest and required cardiopulmonary resuscitation. All patients underwent operation with mild hypothermic cardiopulmonary bypass. Concomitant procedures were performed in 8 patients (3 coronary artery bypass grafts, 2 patent foramen ovale closures, 4 ligations of the left atrial appendage, 3 removals of a right atrial thrombus). Follow-up is 96% complete with a median of 2 years (range, 2 months to 6 years). RESULTS: All patients survived the procedure, but 2 patients died in the hospital on postoperative days 1 (intracerebral bleeding) and 11 (multiorgan failure), accounting for a 30-day mortality of 8% (95% confidence interval: 0.98-0.26). Four patients died later because of their underlying disease. Pre- and postoperative echocardiographic pressure measurements demonstrated the reduction of the pulmonary hypertension to half of the systemic pressure values or less. CONCLUSION: Surgical pulmonary embolectomy is an excellent option for patients with major pulmonary embolism and can be performed with minimal mortality and morbidity. Even patients who present with cardiac arrest and require preoperative cardiopulmonary resuscitation show satisfying results. Immediate surgical desobstruction favorably influences the pulmonary pressure and the recovery of right ventricular function, and remains the treatment of choice for patients with massive central and paracentral embolism with hemodynamic and respiratory compromise.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hypernatremia is common in intensive care units. It has detrimental effects on various physiologic functions and was shown to be an independent risk factor for increased mortality in critically ill patients. Mechanisms of hypernatremia include sodium gain and/or loss of free water and can be discriminated by clinical assessment and urine electrolyte analysis. Because many critically ill patients have impaired levels of consciousness, their water balance can no longer be regulated by thirst and water uptake but is managed by the physician. Therefore, the intensivists should be very careful to provide the adequate sodium and water balance for them. Hypernatremia is treated by the administration of free water and/or diuretics, which promote renal excretion of sodium. The rate of correction is critical and must be adjusted to the rapidity of the development of hypernatremia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE Changes in electrolyte homeostasis are important causes of acid-base disorders. While the effects of chloride are well studied, only little is known of the potential contributions of sodium to metabolic acid-base state. Thus, we investigated the effects of intensive care unit (ICU)-acquired hypernatremia on acid-base state. METHODS We included critically ill patients who developed hypernatremia, defined as a serum sodium concentration exceeding 149 mmol/L, after ICU admission in this retrospective study. Data on electrolyte and acid-base state in all included patients were gathered in order to analyze the effects of hypernatremia on metabolic acid-base state by use of the physical-chemical approach. RESULTS A total of 51 patients were included in the study. The time of rising serum sodium and hypernatremia was accompanied by metabolic alkalosis. A transient increase in total base excess (standard base excess from 0.1 to 5.5 mmol/L) paralleled by a transient increase in the base excess due to sodium (base excess sodium from 0.7 to 4.1 mmol/L) could be observed. The other determinants of metabolic acid-base state remained stable. The increase in base excess was accompanied by a slight increase in overall pH (from 7.392 to 7.429, standard base excess from 0.1 to 5.5 mmol/L). CONCLUSIONS Hypernatremia is accompanied by metabolic alkalosis and an increase in pH. Given the high prevalence of hypernatremia, especially in critically ill patients, hypernatremic alkalosis should be part of the differential diagnosis of metabolic acid-base disorders.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A subscale was developed to assess the quality of life of cancer patients with a life expectancy of six months or less. Phase I of this study identified the major concerns of 74 terminally ill cancer patients (19 with breast cancer, 19 with lung cancer, 18 with colorectal cancer, 9 with renal cell cancer, 9 with prostate cancer), 39 family caregivers, and 20 health care professionals. Patients interviewed were being treated at the University of Texas M. D. Anderson Cancer Center or at the Hospice at the Texas Medical Center in Houston. In Phase II, 120 patients (30 with breast cancer, 30 with lung cancer, 30 with colorectal cancer, 15 with prostate cancer, and 15 with renal cell cancer) rated the importance of these concerns for quality of life. Items retained for the subscale were rated as "extremely important" or "very important" by at least 60% of the sample and were reported as being applicable by at least two-thirds of the sample. The 61 concerns that were identified were formatted as a questionnaire for Phase III. In Phase III, 356 patients (89 with breast cancer, 88 with lung cancer, 88 with colorectal cancer, 44 with prostate cancer, and 47 with renal cell cancer) were interviewed to determine the subscale's reliability and sensitivity to change in clinical status. Both factor analysis and item response theory supported the inclusion of the same 35 items for the subscale. Internal consistency reliability was moderate to high for the subscale's domains: spiritual (0.87), existential (0.76), medical care (0.68), symptoms (0.67), social/family (0.66), and emotional (0.61). Test-retest correlation coefficients also were high for the domains: social/family (0.86), emotional (0.83), medical care (0.83), spiritual (0.75), existential (0.75), and symptoms (0.81).^ In addition, concurrent validity was supported by the high correlation between the subscale's symptom domain and symptom items from the European Organization for Research and Treatment of Cancer (EORTC) scale (r = 0.74). Patients' functional status was assessed with the Eastern Cooperative Oncology Group (ECOG) Performance status rating. When ECOG categories were compared to subscale domains, patients who scored lower in functional status had lower scores in the spiritual, existential, social/family, and emotional domains. Patients who scored lower in physical well-being had higher scores in the symptom domain. Patient scores in the medical care domain were similar for each ECOG category. The results of this study support the subscale's use in assessing quality of life and the outcomes of palliative treatment for cancer patients in their last six months of life. ^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION Hemodynamic management in intensive care patients guided by blood pressure and flow measurements often do not sufficiently reveal common hemodynamic problems. Trans-esophageal echocardiography (TEE) allows for direct measurement of cardiac volumes and function. A new miniaturized probe for TEE (mTEE) potentially provides a rapid and simplified approach to monitor cardiac function. The aim of the study was to assess the feasibility of hemodynamic monitoring using mTEE in critically ill patients after a brief operator training period. METHODS In the context of the introduction of mTEE in a large ICU, 14 ICU staff specialists with no previous TEE experience received six hours of training as mTEE operators. The feasibility of mTEE and the quality of the obtained hemodynamic information were assessed. Three standard views were acquired in hemodynamically unstable patients: 1) for assessment of left ventricular function (LV) fractional area change (FAC) was obtained from a trans-gastric mid-esophageal short axis view, 2) right ventricular (RV) size was obtained from mid-esophageal four chamber view, and 3) superior vena cava collapsibility for detection of hypovolemia was assessed from mid-esophageal ascending aortic short axis view. Off-line blinded assessment by an expert cardiologist was considered as a reference. Inter-rater agreement was assessed using Chi-square tests or correlation analysis as appropriate. RESULTS In 55 patients, 148 mTEE examinations were performed. Acquisition of loops in sufficient quality was possible in 110 examinations for trans-gastric mid-esophageal short axis, 118 examinations for mid-esophageal four chamber and 125 examinations for mid-esophageal ascending aortic short axis view. Inter-rater agreement (Kappa) between ICU mTEE operators and the reference was 0.62 for estimates of LV function, 0.65 for RV dilatation, 0.76 for hypovolemia and 0.77 for occurrence of pericardial effusion (all P < 0.0001). There was a significant correlation between the FAC measured by ICU operators and the reference (r = 0.794, P (one-tailed) < 0.0001). CONCLUSIONS Echocardiographic examinations using mTEE after brief bed-side training were feasible and of sufficient quality in a majority of examined ICU patients with good inter-rater reliability between mTEE operators and an expert cardiologist. Further studies are required to assess the impact of hemodynamic monitoring by mTEE on relevant patient outcomes.