964 resultados para GROUP-4


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to evaluate the antiseptic efficacy of rotary instrumentation associated with calcium hydroxide-based pastes prepared with different vehicles and antiseptics. Chronic periapical lesions were experimentally induced in 72 premolar root canals of four dogs. Under controlled asepsis, after initial microbiological sampling (A1), the root canals were instrumented using the ProFile system in conjunction with 5.25% sodium hypochlorite and the intracanal medication was placed. Four experimental groups were formed according to the pastes used: group 1- Calen (n=18), group 2- Calen+CPMC (n=20), group 3- Ca(OH)2 p.a.+ anaesthetic solution (n=16) and group 4- Ca(OH)2 p.a.+ 2% chlorhexidine digluconate (n=18). After 21 days, the pastes were removed; the canals were emptied and 96 hours later a second microbiological sample was obtained (A2). The incidence of positive microbiological cultures and the number of cfus in stages A1 and A2 were compared statistically by the Wilcoxon test while the influence of the different treatments in intracanal infection was evaluated by Kruskal-Wallis test at 5% significance level (p<0.05). Large numbers of strict and facultative anaerobes, and viridans group streptococci were found in 100% of root canals of A1 samples. Among A2 samples, all treatments showed significant reduction of cfus and positive cultures (p<0.05), but only groups 3 and 4 showed 100% of root canals free of microorganisms. Rotary instrumentation plus NaOCl 5.25% associated with intracanal medication produced a drastic reduction or elimination of intracanal microbiota, whose performance was not influenced by the nature of the vehicle or the antiseptic added to the Ca(OH)2 p.a.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: The purpose of this study was to evaluate the distribution of microorganisms in the root canal system (RCS) and periapical lesions of dogs' teeth after rotary instrumentation and placement of different calcium hydroxide [Ca(OH)2]-based intracanal dressings. MATERIALS AND METHODS: Chronic periapical lesions were experimentally induced in 80 premolar roots of four dogs. Instrumentation was undertaken using the ProFile rotary system and irrigation with 5.25% sodium hypochlorite. The following Ca(OH) 2-based pastes were applied for 21 days: group 1 - Calen (n=18); group 2 - Calen+CPMC (n=20); group 3 - Ca(OH)2 p.a. + anaesthetic solution (n=16) and group 4 - Ca(OH)2 p.a.+ 2% chlorhexidine digluconate (n=18). Eight root canals without endodontic treatment constituted the control group. Histological sections were obtained and stained with Brown & Brenn staining technique to evaluate the presence of microorganisms in the main root canal, ramifications of the apical delta and secondary canals, apical cementoplasts, dentinal tubules, areas of cemental resorption and periapical lesions. The results were analyzed statistically by the Mann-Whitney U test (p<0.05). RESULTS: The control group showed the highest prevalence of microorganisms in all sites evaluated. Gram-positive cocci, bacilli and filaments were the most frequent morphotypes. Similar microbial distribution patterns in the RCS and areas of cementum resorption were observed in all groups (p>0.05). The percentage of RCS sites containing microorganisms in groups 1, 2, 3, 4 and control were: 67.6%, 62.5%, 78.2%, 62.0% and 87.6%, respectively. CONCLUSION: In conclusion, the histomicrobiological analysis showed that the rotary instrumentation and the different calcium hydroxide pastes employed did not effectively eliminate the infection from the RCS and periapical lesions. However, several bacteria seen in the histological sections were probably dead or were inactivated by the biomechanical preparation and calcium hydroxide-based intracanal dressing.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: This study evaluated the potential effects of denture base resin water storage time and an effective denture disinfection method (microwave irradiation at 650 W for 6 minutes) on the torsional bond strength between two hard chairside reline resins (GC Reline and New Truliner) and one heat-polymerizing denture base acrylic resin (Lucitone 199). Materials and Methods: Cylindrical (30 x 3.9 mm) denture base specimens (n = 160) were stored in water at 37°C (2 or 30 days) before bonding. A section (3.0 mm) was removed from the center of the specimens, surfaces prepared, and the reline materials packed into the space. After polymerization, specimens were divided into four groups (n = 10): Group 1 (G1) - tests performed after bonding; Group 2 (G2) - specimens immersed in water (200 ml) and irradiated twice (650 W for 6 minutes); Group 3 (G3) - specimens irradiated daily until seven cycles of disinfection; Group 4 (G4) - specimens immersed in water (37°C) for 7 days. Specimens were submitted to a torsional test (0.1 Nm/min), and the torsional strengths (MPa) and the mode of failure were recorded. Data from each reline material were analyzed by a two-way analysis of variance, followed by Neuman-Keuls test (p = 0.05). Results: For both Lucitone 199 water storage periods, before bonding to GC Reline resin, the mean torsional strengths of G2 (2 days - 138 MPa; 30 days - 132 MPa), G3 (2 days - 126 MPa; 30 days - 130 MPa), and G4 (2 days - 130 MPa; 30 days - 137 MPa) were significantly higher (p < 0.05) than G1 (2 days - 108 MPa; 30 days - 115 MPa). Similar results were found for Lucitone 199 specimens bonded to New Truliner resin, with G1 specimens (2 days - 73 MPa; 30 days - 71 MPa) exhibiting significantly lower mean torsional bond strength (p < 0.05) than G2 (2 day - 86 MPa; 30 days - 90 MPa), G3 (2 days - 82 MPa; 30 days - 82 MPa), and G4 specimens (2 days - 78 MPa; 30 days - 79 MPa). The adhesion of both materials was not affected by water storage time of Lucitone 199 (p > 0.05). GC reline showed a mixed mode of failure (adhesive/cohesive) and New Truliner failed adhesively. Conclusions: Up to seven microwave disinfection cycles did not decrease the torsional bond strengths between the hard reline resins, GC Reline and New Truliner to the denture base resin Lucitone 199. The effect of additional disinfection cycles on reline material may be clinically significant and requires further study. Copyright © 2006 by The American College of Prosthodontists.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to analyze, under scanning electron microscopy (SEM), the morphologic characteristics of root surfaces after application of CarisolvTM gel in association with scaling and root planing (SRP). Sixty periodontally compromised extracted human teeth were randomly assigned to 6 groups: 1) SRP alone; 2) passive topical application of CarisolvTM + SRP; 3) active topical application of CarisolvTM + SRP; 4) multiple applications of CarisolvTM + SRP; 5) SRP + 24% EDTA; 6) topical application of CarisolvTM + SRP + 24% EDTA. CarisolvTM gel was applied to root surfaces for 30 s, followed by scaling and root planing, consisting of 50 strokes with Gracey curettes in an apical-coronal direction, parallel to the long axis of the tooth. The only exception was group 4, in which the roots were instrumented until a smooth, hard and glass-like surface was achieved. All specimens were further analyzed by SEM. The results showed that the treatment with CarisolvTM caused significant changes in root surface morphology of periodontally compromised teeth only when the chemical agent was actively applied (burnishing technique). CarisolvTM failed to remove the smear layer completely, especially with a single application, independently of the method of application. Multiple applications of CarisolvTM were necessary to achieve a smear layer reduction comparable to that obtained with 24% EDTA conditioning.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: This study compared the microtensile bond strength of resin-based cement (Panavia F) to silica-coated, silanized, glass-infiltrated high-alumina zirconia (In-Ceram Zirconia) ceramic in dry conditions and after various aging regimens. Materials and Methods: The specimens were placed in 1 of 4 groups: group 1: dry conditions (immediate testing without aging); group 2: water storage at 37°C for 150 days; group 3: 150 days of water storage followed by thermocycling (× 12,000, 5°C to 55°C); group 4: water storage for 300 days; group 5: water storage for 300 days followed by thermocycling. Results: Group 1 showed a significantly higher microtensile bond strength value (26.2 ± 1 MPa) than the other aging regimens (6.5 ± 1, 6.2 ± 2, 4.5 ± 1, 4.3 ± 1 MPa for groups 2, 3, 4, and 5, respectively) (P < .01). Conclusion: Satisfactory results were seen in dry conditions, but water storage and thermocycling resulted in significantly weaker bonds between the resin cement and the zirconia.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: Since only a few data have been published concerning the effects of resinous dental materials on the pulp-dentin complex, the aim of this study was to evaluate the biocompatibility of resin-based materials applied as liners in deep cavities prepared in duman teeth. Methods: After preparing class V cavities, the following dental materials were applied on the axial walls: group 1, Vitrebond™ (VIT; 3M ESPE); group 2, Ultra-Blend® Plus™ (UBP; Untradent); and group 3, Clearfil™ SE Bond (CSEB; Kuraray). In group 4 (control), the hard-setting calcium hydroxide cement Dycal (CH; Caulk/Dentsply) was used. The teeth extracted at 7 days or between 30 and 85 days after the clinical procedures were processed for histological evaluation. Results: For all the experimental and control groups, most of specimens exhibited no pulpal response or slight inflammatory reaction associated with slight tissue disorganization at 7-day period. Moderate inflammatory pulpal response occurred only in one tooth (RDT = 262 μm) of group 3 in which transdentinal diffusion of resin components was observed. Conclusion: The resin-based dental cements VIT and UBP as well as the bonding agent CSEB presented acceptable biocompatibility when applied in deep cavities prepared in sound human teeth. © 2006 Wiley Periodicals, Inc.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Economic evaluation of the treatment bovine subclinical mastitis caused by S. aureus was evaluated. Two hundred and seventy udder quarters with or without subclinical mastitis were distributed into four groups, in conformity to lactational stage and treatments. Group 1 included animals treated between 10 and 60 days of lactation; group 2 included animals treated from 61 days of lactation to two months before drying; group 3 included animals no treated between 10 and 60 days of lactation; group 4 included animals no treated from 61 days of lactation to two months before drying. Treatment with gentamicin (150mg) was accomplished by intramammary doses, once a day, after performing sensitivity tests. The mammary quarters were re-evaluated after 30 days. The costs with the treatment were calculated considering a S. aureus prevalence of 5% as well as expenses with antibiotic, milk disposal, tests of drug sensitivity and workload. There was loss of income of 2% and 14% in the groups 1 and 2, respectively, when compared with the values before the treatment. In such case, the treatment of bovine subclinical mastitis caused by S. aureus in the lactation was economically unviable.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Doppler echocardiography has been used for the diagnosis of anthracycline-induced cardiotoxicity. However, few data are available that include asymptomatic children previously treated with a low cumulative dose of this drug and therefore have a low risk of cardiac dysfunction. The aim of this study was to evaluate after-exercise cardiac function in asymptomatic children previously treated with a low cumulative dose of anthracycline and no clinical or laboratory evidence of cardiotoxicity. Doppler echocardiography was performed before and immediately after physical exercise in 29 children aged 5 to 17 years (anthracycline [ADRIA] group). All had finished cancer treatment with anthracycline derivatives for ≥1 year (cumulative dose 100 mg/m2). Results were compared with those from age- and gender-matched healthy children (control group; n = 26) using the Mann-Whitney rank test. Exercise-induced cardiac function changes within groups were analyzed using Wilcoxon's signed-rank test. Exercise induced significant increases in left ventricular systolic function indexes in both groups. However, the ADRIA group had significantly lower changes in left ventricular ejection fraction (ADRIA group 0.71 ± 0.02 vs 0.80 ± 0.04 and control group 0.71 ± 0.02 vs 0.89 ± 0.05, p = 0.0017) and end-systolic stress-volume index (ADRIA group 4.59 ± 0.69 vs 6.4 ± 2.0 g.cm-2/ml.m-2 and control group 5.49 ± 0.98 vs 11.54 ± 2.86 g.cm-2/ml.m-2; p <0.0001), indicating decreased functional systolic reserve. In conclusion, asymptomatic children previously treated with low cumulative doses of anthracycline had decreased functional systolic reserve evidenced by exercise, suggesting a nonclinically manifested cardiotoxicity. © 2007 Elsevier Inc. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The cost benefit analysis of treatment of bovine subclinical mastitis caused by S. aureus was evaluated. Two hundred and seventy udder quarters with subclinical mastitis and healthy were selected in four groups, in conformity to lactational stage and with the treatment or not. Group 1 included treated animals 10 to 60 days in milk; group 2 included treated animals 61 days in milk until two months before the end of lactation; group 3 included animals not treated 10 to 60 days in milk; group 4 included animals not treated from 61 days in milk until two months before the end of lactation. Treatment with gentamicin (150 mg) was accomplished by intramammary doses, once a day, after sensitivity tests. The mammary quarters were evaluated after 30 days again. The costs with the treatment were calculated considering a S. aureus prevalence of 5%, expenses with antibiotic, loss in milk, tests of sensitivity and workload. There was loss of income of 2% and 14% in the groups 1 and 2, respectively, when compared with the incomes before treatment. In such case, the treatment of bovine subclinical mastitis by S. aureus in the lactation was economically not practicable.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To evaluate the cytotoxic effects of different concentrations of Chlorhexidine (Chx) to the odontoblast cell line MDPC-23. Methods: The odontoblast-like cells were seeded (30,000 cells/cm 2) in 60 wells of 24-well dishes and then incubated in contact with the following experimental and control solutions: Group 1: 0.0024% Chx; Group 2: 0.004% Chx; Group 3: 0.02% Chx; Group 4: Phosphate buffer saline solution (PBS, negative control); and Group 5: 0.06% H 2O 2 (positive control). Cell metabolic activity was measured by MTT assay and the cell morphology was analyzed by SEM. Results: The cytotoxic effects of Chx are dose-dependent. The reduction in the cell metabolism for Groups 1, 2, and 3 was 24.8%, 29.9% and 70.8%, respectively. No statistical difference was observed between the Groups 1 and 2 in which no significant cell morphology changes occurred. Consequently, it was concluded that 0.02% Chx solution presents high cytotoxicity to the odontoblast-like cells MDPC-23. On theother hand, 0.0024% and 0.004% Chx causes slight cytopathic effects to the cultured cells.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: The purpose of this study was to verify the influence of surface sealants and dentin adhesive systems on the microleakage of composite restorations. Methods: Class V cavities were made on the buccal faces of 100 permanent third molars and restored with Z250. After 24 hours, they were submitted to polishing and finishing processes. The teeth were divided into groups according to the sealant agent: group 1 - Single Bond; group 2 - Opti Bond Solo Plus; group 3 - Fortify; group 4 - Fortify Plus; and group 5 - control without sealant. The analysis of immediate microleakage was performed in 10 restorations from each group, soon after the sealing. The other 10 specimens from each group were submitted to tooth-brushing and thermal cycles. The teeth were isolated and immersed in 2% methylene blue solution, washed in tap water, and sectioned in the buccolingual direction. The percentage of marginal leakage was calculated using an image analysis program, and results were submitted to analysis of variance and Tukey's test. Results: All the sealed groups demonstrated lower microleakage values compared to the control group. Group 3, sealed with Fortify, presented the lowest mean microleakage values. Conclusion: The application of surface sealants effectively decreased the microleakage in composite resin restorations.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aim: Based on the hypothesis the application of a low-viscosity hydrophobic resin coating improves the bond of all-in-one adhesive, the purpose of the study was to evaluate the bond strength of four adhesive systems to bovine root dentin using the push-out test method. Methods and Materials: The root canals of 32 bovine roots (16 mm) were prepared to a length of 12 mm using a FRC Postec Plus preparation drill. The specimens were allocated into four groups according to the adhesive system used: (Group 1) All-in-one Xeno III; (Group 2) All-in-one Xeno III+ScotchBond Multi-Purpose Plus Adhesive; (Group 3) Simplified Etch & Rinse One Step Plus; and (Group 4) Multi-Bottle Etch & Rinse All-Bond 2. A fiber-reinforced composite retention post was reproduced using an additional silicon impression and fabricated with DuoLink resin cement. The root specimens were treated with the selected adhesive systems, and the resin posts were luted in the canals with DuoLink resin cement. Each root specimen was cross sectioned into four samples (±1.8 mm in thickness), and the post sections were pushed-out to determine the bond strength to dentin. Results: Group 2 (2.9±1.2) was statistically higher than Group 1 (1.1±0.5) and Group 3 (1.1±0.5). Groups 1 and 3 showed no statistically significant difference while Group 4 (2.0±0.7) presented similar values (p>0.05) to Groups 1, 2, and 3 [(one-way analysis of variance (ANOVA)] and Tukey test, α=0.05). Conclusion: The hypothesis was accepted since the application of the additional layer of a low-viscosity bonding resin improved the bond of the all-in-one adhesive. Further studies must be conducted to evaluate the long-term bond.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The objective of this in vitro study was to evaluate demineralization around restorations. Class V preparations were made on the buccal and lingual surfaces of each tooth. TPH (Group 1), Fuji II LC (Group 2), Tetric (Group 3), Dyract (Group 4), GS 80 (Group 5) and Chelon Fil (Group 6) were randomly placed in equal numbers of teeth. The teeth were submitted to a pH-cycling model associated with a thermocycling model. Sections were made and the specimens were examined for the presence of demineralization under polarized light microscopy. Demineralization was significantly reduced with Chelon Fil (Group 6). Furthermore, a similar inhibitory effect on the development of demineralization was observed in Groups 2, 4 and 5.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVES: Based on the knowledge of the anti-inflammatory and anti-bacterial actions of local anesthetics (LA), the objective of this study was to determine the effects of peritoneal lavage with bupivacaine on survival of mice with fecal peritonitis. METHODS: Forty-eight Wistar mice, weighing between 300 and 330 g (311.45 ± 9.67 g), undergoing laparotomy 6 hours after induction of peritonitis were randomly divided in 4 groups: 1 - Control, without treatment (n = 12); 2 - Drying of the abdominal cavity (n = 12); 3 - Lavage with 3 mL NS and posterior drying of the abdominal cavity (n = 12); and 4 - Lavage with 8 mg.kg -1 (± 0.5 mL) of 0.5% bupivacaine added to 2.5 mL of NS followed by drying out of the abdominal cavity (n = 12). Animals that died underwent necropsy and the time of death was recorded. Surviving animals were killed on the 11 th postoperative day and underwent necropsy. RESULTS: Group 1 presented a 100% mortality rate in 52 hours, 100% mortality rate in Group 2 in 126 hours, and Group 3 presented a 50% mortality rate in 50 hours. Animals in Group 4 survived. Survival on the 11 th day was greater in groups 3 and 4 than in Groups 1 and 2 (p < 0.001) and greater in Group 4 than in Group 3 (p < 0.01). CONCLUSIONS: Peritoneal lavage with a solution of bupivacaine diluted in NS was effective in preventing death for 11 days in 100% of animals with fecal peritonitis. © Sociedade Brasileira de Anestesiologia, 2008.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Several studies have reported the benefits of sonic and/or ultrasonic instrumentation for root debridement, with most of them focusing on changes in periodontal clinical parameters. The present study investigated possible alterations in the tensile bond strength of crowns cemented with zinc phosphate cement to natural teeth after ultrasonic instrumentation. Forty recently extracted intact human third molars were selected, cleaned and stored in physiologic serum at 4°C. They received standard preparations, at a 16° convergence angle, and AgPd alloy crowns. The crowns were cemented with zinc phosphate cement and then divided into four groups of 10 teeth each. Each group was then subdivided into two subgroups, with one of the subgroups being submitted to 5,000 thermal cycles ranging from 55 ± 2 to 5 ± 2°C, while the other was not. Each group was submitted to ultrasonic instrumentation for different periods of time: group 1 - 0 min (control), group 2 - 5 min, group 3 - 10 min, and group 4 - 15 min. Tensile bond strength tests were performed with an Instron testing machine (model 4310). Statistical analysis was performed using ANOVA and Tukey's test at the 5% level of significance. A significant reduction in the tensile bond strength of crowns cemented with zinc phosphate and submitted to thermal cycles was observed at 15 min (196.75 N versus 0 min = 452.01 N, 5 min = 444.23 N and 10 min = 470.85 N). Thermal cycling and ultrasonic instrumentation for 15 min caused a significant reduction in tensile bond strength (p < .05).