893 resultados para Fatigue Crack Nucleation
Resumo:
This paper studied the influence of hydrogen and water vapour environments on the plastic behaviour in the vicinity of the crack tip for AISI 4340. Hydrogen and water vapour (at a pressure of 15 Torr) significantly increased the crack tip opening displacement. The crack tip strain distribution in 15 Torr hydrogen was significantly different to that measured in vacuum. In the presence of sufficient hydrogen, the plastic zone was larger, was elongated in the direction of crack propagation and moreover there was significant creep. These observations support the hydrogen enhanced localised plasticity model for hydrogen embrittlement in this steel. The strain distribution in the presence of water vapour also suggests that SCC in AISI 4340 occurs via the hydrogen enhanced localised plasticity mechanism. (C) 1999 Kluwer Academic Publishers.
Resumo:
Associations between self-reported 'low iron', general health and well-being, vitality and tiredness in women, were examined using physical (PCS) and mental (MCS) component summary and vitality (VT) scores from the MOS short-form survey (SF-36). 14,762 young (18-23 years) and 14,072 mid-age (45-50 years) women, randomly selected from the national health insurance commission (Medicare) database, completed a baseline mailed self-report questionnaire and 12,328 mid-age women completed a follow-up questionnaire 2 years later. Young and mid-age women who reported (ever) having had 'low iron' reported significantly lower mean PCS, MCS and VT scores, and greater prevalence of 'constant tiredness' at baseline than women with no history of iron deficiency [Differences: young PCS = -2.2, MCS = -4.8, VT = -8.7; constant tiredness: 67% vs. 45%; mid-age PCS = -1.4, MCS = -3.1, VT = -5.9; constant tiredness: 63% vs. 48%]. After adjusting for number of children, chronic conditions, symptoms and socio-demographic variables, mean PCS, MCS and VT scores for mid-age women at follow-up were significantly lower for women who reported recent iron deficiency (in the last 2 years) than for women who reported past iron deficiency or no history of iron deficiency [Means: PCS - recent = 46.6, past = 47.8, never = 47.7; MCS - recent = 45.4, past = 46.9, never = 47.4; VT - recent = 54.8, past = 57.6, never = 58.6]. The adjusted mean change in PCS, MCS and VT scores between baseline and follow-up were also significantly lower among mid-age women who reported iron deficiency only in the last 2 years (i.e. recent iron deficiency) [Mean change: PCS = -3.2; MCS = -2.1; VT = -4.2]. The results suggest that iron deficiency is associated with decreased general health and well-being and increased fatigue.
Resumo:
The effects of different levels of strontium on nucleation and growth of the eutectic in a commercial hypoeutectic Al-Si foundry alloy have been investigated by optical microscopy and electron backscattering diffraction (EBSD) mapping by scanning electron microscopy (SEM). The microstructural evolution of each specimen during solidification was studied by a quenching technique at different temperatures and Sr contents. By comparing the orientation of the aluminum in the eutectic to that of the surrounding primary aluminum dendrites by EBSD, the eutectic formation mechanism could be determined. The results of these studies show that the eutectic nucleation mode, and subsequent growth mode, is strongly dependent on Sr level. Three distinctly different eutectic growth modes were found, in isolation or sometimes together, but different for each Sr content. At very low Sr contents, the eutectic nucleated and grew from the primary phase. Increasing the Sr level to between 70 and 110 ppm resulted in nucleation of independent eutectic grains with no relation to the primary dendrites. At a Sr level of 500 ppm, the eutectic again nucleated on and grew from the primary phase while a well-modified eutectic structure was still present. A slight dependency of eutectic growth radially from the mold wall opposite the thermal gradient was observed in all specimens in the early stages of eutectic solidification.
Resumo:
The pathophysiology of chronic fatigue syndrome (CFS) remains unclear; however, both biological and psychological factors have been implicated in establishing or maintaining this condition. People with CFS report significant and disabling cognitive difficulties such as impaired concentration that in some cases are exacerbated by exposure to chemical triggers. The aim of this study was to determine if neuropsychological deficits in CFS are triggered by exposure to chemicals, or perceptions about the properties of these substances. Participants were 36 people with a primary diagnosis of CFS, defined according to Centers for Disease Control (CDC) criteria. A randomized, double-blind, placebo-controlled, crossover design was used, with objective assessment of neuropsychological function and participant rating of substance type, before and after exposure to placebo or chemical trigger. Results showed decrements in neuropsychological tests scores on three out of four outcome measures when participants rated the substance they had been exposed to as chemical. No change in performance was found based on actual substance type. These results suggest that cognitive attributions about exposure substances in people with CFS may be associated with worse performance on neuropsychological tasks. In addition, these findings suggest that psychological interventions aimed at modifying substance-related cognitions may reduce some symptoms of CFS.
Resumo:
An experimental white cast iron with the unprecedented fracture tough ness of 40 MPa m(1/2) is currently being studied to determine the mechanisms of toughening. This paper reports the investigation of the role of strain-induced martensitic (SIM) transformation. The dendritic microconstituent in the toughened alloy consists primarily of retained austenite, with precipitated M(7)C(3) carbides and some martensite. Refrigeration experiments and differential scanning calorimetry (DSC) were used to demonstrate, firstly, that this retained austenite has an ''effective'' sub-ambient M(S) temperature and, secondly, that SIM transformation can occur at ambient temperatures. Comparison between room temperature and elevated temperature K-Ic tests showed that the observed SIM produces a transformation toughening response in the alloy, contributing to, but not fully accounting for, its high tough ness. SIM as a mechanism for transformation toughening has not previously been reported for white cast irons. Microhardness traverses on crack paths and X-ray diffraction (XRD) on fracture surfaces confirmed the interpretation of the K-Ic experiments. Further DSC and quantitative XRD showed that, as heat-treatment temperature is varied, there is a correlation between fracture toughness and the volume fraction of unstable retained austenite.
Resumo:
Objective: The purpose of the present study was to review a group of patients with meniscal injuries resulting from structural failure unrelated to trauma or degenerative problems to which was given the name ""meniscal injury due to fatigue"". Material and Method: Evaluations were made on 140 patients with meniscal injuries without any apparent cause, who were therefore considered to have meniscal injuries due to fatigue. Among these, 85 patients were male and 55 were female. The medial meniscus was the most affected site (92% of the cases). Results: All these injuries were diagnosed by means of clinical examination and magnetic resonance imaging. The patients underwent meniscectomy by means of arthroscopy and the results were divided into two types: good and poor. Poor results were found in 27% of the cases, among which nine patients progressed to idiopathic osteonecrosis. Conclusion: We conclude that injuries due to fatigue must be assessed as injuries caused by failure and, therefore, constituting a syndromic pathological condition that may progress to idiopathic osteonecrosis.
Resumo:
Background Although fatigue is a ubiquitous symptom across countries, clinical descriptions of chronic fatigue syndrome have arisen from a limited number of high-income countries. This might reflect differences in true prevalence or clinical recognition influenced by sociocultural factors. Aims To compare the prevalence, physician recognition and diagnosis of chronic fatigue syndrome in London and Sao Paulo. Method Primary care patients in London (n=2459) and Sao Paulo n=3914) were surveyed for the prevalence of chronic fatigue syndrome. Medical records were reviewed for the physician recognition and diagnosis. Results The prevalence of chronic fatigue syndrome according to Centers for Disease Control 1994 criteria was comparable in Britain and Brazil, 2.1% v. 1.6% (P=0.20). Medical records review identified 11 diagnosed cases of chronic fatigue syndrome in Britain, but none in Brazil (P<0.001). Conclusions The primary care prevalence of chronic fatigue syndrome was similar in two Culturally and economically distinct nations. However, doctors are unlikely to recognise and label chronic fatigue syndrome as a discrete disorder in Brazil. The recognition of this illness rather than the illness itself may be culturally induced.
Resumo:
Objective: While in many Western affluent countries there is widespread awareness of chronic fatigue syndrome (CFS), also known as myalgic encephalomyelitis (ME), little is known about the awareness of CFS/ME in low- and middle-income countries. We compared the awareness of CFS in Brazil and the United Kingdom. Methods: Recognition and knowledge of CFS were assessed among 120 Brazilian specialist doctors in two major university hospitals using a typical case vignette of CFS. We also surveyed 3914 and 2435 consecutive attenders in Brazilian and British primary care clinics, respectively, concerning their awareness of CFS. Results: When given a typical case vignette of CFS, only 30.8% [95% confidence interval (CI), 22.7-39.9%] of Brazilian specialist doctors mentioned chronic fatigue or CFS as a possible diagnosis, a proportion substantially lower than that observed in Western affluent countries. Similarly, only 16.2% (95% CI, 15.1-17.4%) of Brazilian primary care attenders were aware of CFS, in contrast to 55.1% (95% CI, 53.1-57.1%) of their British counterparts (P <.001). This difference remained highly significant after controlling for patients` sociodemographic and socioeconomic characteristics (P <.001). Conclusions: The awareness of CFS was substantially lower in Brazil than the United Kingdom. The observed difference may influence patients` help-seeking behavior and both doctors` and patients` beliefs and attitudes in relation to fatigue-related syndromes. Attempts to promote the awareness of CFS should be considered in Brazil, but careful plans are required to ensure the delivery of sound evidence-based information. (c) 2008 Elsevier Inc. All rights reserved.
Resumo:
Crack cocaine-dependent individuals (CCDI) present abnormalities in both social adjustment and decision making, but few studies have examined this association. This study investigated cognitive and social performance of 30 subjects (CCDI x controls); CCDI were abstinent for 2 weeks. We used the Social Adjustment Scale (SAS), Wisconsin Card Sorting Test (WCST), and Iowa Gambling Task (IGT). Disadvantageous choices on the IGT were associated with higher levels of social dysfunction in CCDI, suggesting the ecological validity of the IGT. Social dysfunction and decision making may be linked to the same underlying prefrontal dysfunction, but the nature of this association should be further investigated. (Am J Addict 2010;00: 1-9).
Resumo:
In Spain, crack cocaine use is silently increasing. In Barcelona, an intentional sample was selected to describe the general characteristics of this consumption. Participants were submitted to an interview and data were analyzed through qualitative research procedures. Users are young males and of low socioeconomic status and formal education. The major pattern of use is compulsive. Illegal income activities are the choice for crack cocaine or money acquisition, increasing individual and social health costs. Polydrug use is a matter of concern. Although these findings can not be generalized, they should be considered for the development of public policies to adequately address crack cocaine users` needs.
Resumo:
Smoked cocaine (crack cocaine) causes several forms of injury to the respiratory tract, including asthma exacerbations, lung edema and hemorrhage, and nasal mucosal alterations. Few studies, however, have assessed respiratory tract pathology in habitual users of crack cocaine. Here, we describe the histological alterations in the respiratory tract of mice caused by chronic inhalation of crack cocaine. Twenty 2-month-old BALB/c mice were exposed to the smoke of 5 g crack cocaine in an inhalation chamber once a day for two months and compared to controls (n = 10). We then morphometrically analyzed nose and bronchiolar epithelial alterations, bronchiolar and alveolar macrophage cell density, alveolar hemosiderin content, and in addition determined the vasoconstriction index and the wall thickness of pulmonary arteries. The serum cocaine level was 212.5 ng/mL after a single inhalation. The mucus content of the nasal epithelium increased in crack-exposed animals, and the nasal and bronchial epithelium thickness decreased significantly. The alveolar hemosiderin content and the alveolar and bronchiolar macrophage cell density increased in animals exposed to crack. The vasoconstriction index increased in the pulmonary arteries of the exposed group. Chronic crack cocaine inhalation causes extensive histological changes along the entire respiratory tract.
Resumo:
We aimed to quantify fatigue frequency and evolution in amyotrophic lateral sclerosis (ALS), and to correlate fatigue with factors such as age, sex, educational level, disease duration, functionality, quality of life, dyspnoea, depression and sleepiness. Sixty ALS patients (test group: TG) selected by El Escorial criteria and 60 normal individuals (control group: CG) matched according to sex and age, were followed every three months, during 9 months, by means of self-report scales: Fatigue Assessment Instrument (Fatigue Severity Scale plus three qualitative subscales); ALS Functional Rating Scale; McGill Quality of Life Questionnaire; dyspnoea analogical scale; Beck Depression Inventory and Epworth Sleepiness Scale. Fatigue was reported by 83% of TG (median: 3.6, interquartile range 1.5-5.4), compared with 20% of CG (median: 1, 1 - 1), and was significantly greater in the TG (p < 0.001, Mann-Whitney test). Fatigue severity increased by the ninth month of the study (p=0.0008, Friedman, Muller-Dunn post test). There was no correlation between fatigue and other parameters, except for an inverse correlation with age at disease onset (p=0.0395, Spearman rank correlation). In conclusion, fatigue was frequent in ALS, greater in the youngest patients and worsened during follow-up. Possibly, ALS related fatigue is an independent factor, which deserves individualized approach and treatment.
Resumo:
Introduction: The aim of this study was to assess cyclic fatigue resistance in rotary nickel-titanium instruments submitted to nitrogen ion implantation by using a custom-made cyclic fatigue testing apparatus. Methods: Thirty K3 files, size #25, taper 0.04, were divided into 3 experimental groups as follows: group A, 12 files exposed to nitrogen ion implantation at a dose of 2.5 x 10(17) ions/cm(2), accelerating voltage of 200 kV, currents of 1 mu A/cm(2), 130 degrees C temperature, and vacuum conditions of 10 x 10(-6) torr for 6 hours; group B, 12 nonimplanted files; and group C, 6 files submitted to thermal annealing for 6 hours at 130 degrees C. One extra file was used for process control. All files were submitted to a cyclic fatigue test that was performed with an apparatus that allowed the instruments to rotate freely, simulating rotary instrumentation of a curved canal (40-degree, 5-mm radius curve). An electric motor handpiece was used with a contra-angle of 16:1 at an operating speed of 300 rpm and a torque of 2 N-cm. Time to failure was recorded with a stopwatch in seconds and subsequently converted to number of cycles to fracture. Data were analyzed with the Student t test (P < .05). Results: Ion-implanted instruments reached significantly higher cycle numbers before fracture (mean, 510 cycles) when compared with annealed (mean, 428 cycles) and nonimplanted files (mean, 381 cycles). Conclusions: Our results showed that nitrogen ion implantation improves cyclic fatigue resistance in rotary nickel-titanium instruments. Industrial implementation. of this surface modification technique would produce rotary nickel-titanium instruments with a longer working life. (J Endod 2010;36:1183-1186)
Resumo:
The objective was to compare fracture toughness (K(Ic)), stress corrosion susceptibility coefficient (n), and stress intensity factor threshold for crack propagation (K(I0)) of two porcelains [VM7/Vita (V) and d.Sign/Ivoclar (D)], two glass-ceramics [Empress/Ivolcar (E1) and Empress2/Ivlocar (E2)] and a glass-infiltrated alumina composite [In-Ceram Alumina/Vita (IC)]. Disks were constructed according to each manufacturer`s processing method, and polished before induction of cracks by a Vickers indenter. Crack lengths were measured under optical microscopy at times between 0.1 and 100 h. Specimens were stored in artificial saliva at 37A degrees C during the whole experiment. K(Ic) and n were determined using indentation fracture method. K(I0) was determined by plotting log crack velocity versus log K(I). Microstructure characterization was carried out under SEM, EDS, X-ray diffraction and X-ray fluorescence. IC and E2 presented higher K(Ic) and K(I0) compared to E1, V, and D. IC presented the highest n value, followed by E2, D, E1, and V in a decreasing order. V and D presented similar K(Ic), but porcelain V showed higher K(I0) and lower n compared to D. Microstructure features (volume fraction, size, aspect ratio of crystalline phases and chemical composition of glassy matrix) determined K(Ic). The increase of K(Ic) value favored the increases of n and K(I0).
Resumo:
Objectives. To evaluate the effect of the microstructure on the Weibull and slow crack growth (SCG) parameters and on the lifetime of three ceramics used as framework materials for fixed partial dentures (FPDs) (YZ - Vita In-Ceram YZ; IZ - Vita In-Ceram Zirconia; AL - Vita In-Ceram AL) and of two veneering porcelains (VM7 and VM9). Methods. Bar-shaped specimens were fabricated according to the manufacturer`s instructions. Specimens were tested in three-point flexure in 37 degrees C artificial saliva. Weibull analysis (n = 30) and a constant stress-rate test (n = 10) were used to determine the Weibull modulus (m) and SCG coefficient (n), respectively. Microstructural and fractographic analyzes were performed using SEM. ANOVA and Tukey`s test (alpha = 0.05) were used to statistically analyze data obtained with both microstructural and fractographic analyzes. Results. YZ and AL presented high crystalline content and low porosity (0.1-0.2%). YZ had the highest characteristic strength (sigma(0)) value (911 MPa) followed by AL (488 MPa) and IZ (423 MPa). Lower sigma(0) values were observed for the porcelains (68-75 MPa). Except for IZ and VM7, m values were similar among the ceramic materials. Higher n values were found for YZ (76) and AL (72), followed by IZ (54) and the veneering materials (36-44). Lifetime predictions showed that YZ was the material with the best mechanical performance. The size of the critical flaw was similar among the framework materials (34-48 mu m) and among the porcelains (75-86 mu m). Significance. The microstructure influenced the mechanical and SCG behavior of the studied materials and, consequently, the lifetime predictions. (C) 2011 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.