869 resultados para FETAL HEART RATE
Resumo:
Changes in heart rate (f(H)) and cloacal ventilation frequency (f(C)) were investigated in the Fitzroy turtle, Rheodytes leukops, under normoxic (17.85 kPa) and hypoxic (3.79 kPa) conditions at 25 degrees C. Given R. leukops' high reliance on aquatic respiration via the cloacal bursae, the objective Of this Study was to examine the effect of varying aquatic PO2 levels upon the expression of a bradycardia in a freely diving, bimodally respiring turtle. In normoxia, mean diving f(H) and f(C) for R. leukops remained constant with increasing submergence length, indicating that a bradycardia failed to develop during extended dives of up to 3 days. Alternatively, exposure to aquatic hypoxia resulted in the expression of a bradycardia as recorded by a decreasing mean diving f(H) with increasing dive duration. The observed bradycardia is attributed to a hypoxic-induced metabolic depression, possibly facilitated by a concurrent decrease in f(C). Results suggest that R. leukops alters its strategy from aquatic O-2 extraction via cloacal respiration in normoxia to O-2 conservation when exposed to aquatic hypoxia for the purpose of extending dive duration. Upon surfacing, a significant tachycardia was observed for R. leukops regardless of aquatic PO2, presumably functioning to rapidly equilibrate blood and tissue gas tensions with alveolar gas to reduce surfacing duration.
Resumo:
Since its introduction, pulse oximetry has become a conventional clinical measure. Besides being arterial blood oxygen saturation (SpO2) measure, pulse oximeters can be used for other cardiovascular measurements, like heart rate (HR) estimations, derived from its photo plethysmographic (PPG) signals. The temporal coherence of the PPG signals and thereby HR estimates are heavily dependent on its minimal phase variability. A Masimo SET Rad-9TM, Novametrix Oxypleth and a custom designed PPG system were investigated for their relative phase variation. R-R intervals from electro-cardiogram (ECG) were recorded concurrently as reference. PPG signals obtained from the 3 systems were evaluated by comparing their respective beat-to-beat (B-B) intervals with the corresponding R-R estimates during a static test. For their relative B-B comparison to the ECG, Novametrix system differed 0.680.52% (p
Resumo:
In this paper, a new method for characterizing the newborn heart rate variability (HRV) is proposed. The central of the method is the newly proposed technique for instantaneous frequency (IF) estimation specifically designed for nonstationary multicomponen signals such as HRV. The new method attempts to characterize the newborn HRV using features extracted from the time–frequency (TF) domain of the signal. These features comprise the IF, the instantaneous bandwidth (IB) and instantaneous energy (IE) of the different TF components of the HRV. Applied to the HRV of both normal and seizure suffering newborns, this method clearly reveals the locations of the spectral peaks and their time-varying nature. The total energy of HRV components, ET and ratio of energy concentrated in the low-frequency (LF) to that in high frequency (HF) components have been shown to be significant features in identifying the HRV of newborn with seizures.
Resumo:
In this paper, we propose features extracted from the heart rate variability (HRV) based on the first and second conditional moments of time-frequency distribution (TFD) as an additional guide for seizure detection in newborn. The features of HRV in the low frequency band (LF: 0-0.07 Hz), mid frequency band (MF: 0.07-0.15 Hz), and high frequency band (HF: 0.15-0.6 Hz) have been obtained by means of the time-frequency analysis using the modified-B distribution (MBD). Results of ongoing time-frequency research are presented. Based on our preliminary results, the first conditional moment of HRV which is also known as the mean/central frequency in the LF band and the second conditional moment of HRV which is also known as the variance/instantaneous bandwidth (IB) in the HF band can be used as a good feature to discriminate the newborn seizure from the non-seizure
Relationship between laboratory measured variables and heart rate during an untraendurance triathlon
Resumo:
Objective: To assess and explain deviations from recommended practice in National Institute for Clinical Excellence (NICE) guidelines in relation to fetal heart monitoring. Design: Qualitative study. Setting: Large teaching hospital in the UK. Sample: Sixty-six hours of observation of 25 labours and interviews with 20 midwives of varying grades. Methods: Structured observations of labour and semistructured interviews with midwives. Interviews were undertaken using a prompt guide, audiotaped, and transcribed verbatim. Analysis was based on the constant comparative method, assisted by QSR N5 software. Main outcome measures: Deviations from recommended practice in relation to fetal monitoring and insights into why these occur. Results: All babies involved in the study were safely delivered, but 243 deviations from recommended practice in relation to NICE guidelines on fetal monitoring were identified, with the majority (80%) of these occurring in relation to documentation. Other deviations from recommended practice included indications for use of electronic fetal heart monitoring and conduct of fetal heart monitoring. There is evidence of difficulties with availability and maintenance of equipment, and some deficits in staff knowledge and skill. Differing orientations towards fetal monitoring were reported by midwives, which were likely to have impacts on practice. The initiation, management, and interpretation of fetal heart monitoring is complex and distributed across time, space, and professional boundaries, and practices in relation to fetal heart monitoring need to be understood within an organisational and social context. Conclusion: Some deviations from best practice guidelines may be rectified through straightforward interventions including improved systems for managing equipment and training. Other deviations from recommended practice need to be understood as the outcomes of complex processes that are likely to defy easy resolution. © RCOG 2006.