975 resultados para Evaluation cycle


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The PhD project addresses the potential of using concentrating solar power (CSP) plants as a viable alternative energy producing system in Libya. Exergetic, energetic, economic and environmental analyses are carried out for a particular type of CSP plants. The study, although it aims a particular type of CSP plant – 50 MW parabolic trough-CSP plant, it is sufficiently general to be applied to other configurations. The novelty of the study, in addition to modeling and analyzing the selected configuration, lies in the use of a state-of-the-art exergetic analysis combined with the Life Cycle Assessment (LCA). The modeling and simulation of the plant is carried out in chapter three and they are conducted into two parts, namely: power cycle and solar field. The computer model developed for the analysis of the plant is based on algebraic equations describing the power cycle and the solar field. The model was solved using the Engineering Equation Solver (EES) software; and is designed to define the properties at each state point of the plant and then, sequentially, to determine energy, efficiency and irreversibility for each component. The developed model has the potential of using in the preliminary design of CSPs and, in particular, for the configuration of the solar field based on existing commercial plants. Moreover, it has the ability of analyzing the energetic, economic and environmental feasibility of using CSPs in different regions of the world, which is illustrated for the Libyan region in this study. The overall feasibility scenario is completed through an hourly analysis on an annual basis in chapter Four. This analysis allows the comparison of different systems and, eventually, a particular selection, and it includes both the economic and energetic components using the “greenius” software. The analysis also examined the impact of project financing and incentives on the cost of energy. The main technological finding of this analysis is higher performance and lower levelized cost of electricity (LCE) for Libya as compared to Southern Europe (Spain). Therefore, Libya has the potential of becoming attractive for the establishment of CSPs in its territory and, in this way, to facilitate the target of several European initiatives that aim to import electricity generated by renewable sources from North African and Middle East countries. The analysis is presented a brief review of the current cost of energy and the potential of reducing the cost from parabolic trough- CSP plant. Exergetic and environmental life cycle assessment analyses are conducted for the selected plant in chapter Five; the objectives are 1) to assess the environmental impact and cost, in terms of exergy of the life cycle of the plant; 2) to find out the points of weakness in terms of irreversibility of the process; and 3) to verify whether solar power plants can reduce environmental impact and the cost of electricity generation by comparing them with fossil fuel plants, in particular, Natural Gas Combined Cycle (NGCC) plant and oil thermal power plant. The analysis also targets a thermoeconomic analysis using the specific exergy costing (SPECO) method to evaluate the level of the cost caused by exergy destruction. The main technological findings are that the most important contribution impact lies with the solar field, which reports a value of 79%; and the materials with the vi highest impact are: steel (47%), molten salt (25%) and synthetic oil (21%). The “Human Health” damage category presents the highest impact (69%) followed by the “Resource” damage category (24%). In addition, the highest exergy demand is linked to the steel (47%); and there is a considerable exergetic demand related to the molten salt and synthetic oil with values of 25% and 19%, respectively. Finally, in the comparison with fossil fuel power plants (NGCC and Oil), the CSP plant presents the lowest environmental impact, while the worst environmental performance is reported to the oil power plant followed by NGCC plant. The solar field presents the largest value of cost rate, where the boiler is a component with the highest cost rate among the power cycle components. The thermal storage allows the CSP plants to overcome solar irradiation transients, to respond to electricity demand independent of weather conditions, and to extend electricity production beyond the availability of daylight. Numerical analysis of the thermal transient response of a thermocline storage tank is carried out for the charging phase. The system of equations describing the numerical model is solved by using time-implicit and space-backward finite differences and which encoded within the Matlab environment. The analysis presented the following findings: the predictions agree well with the experiments for the time evolution of the thermocline region, particularly for the regions away from the top-inlet. The deviations observed in the near-region of the inlet are most likely due to the high-level of turbulence in this region due to the localized level of mixing resulting; a simple analytical model to take into consideration this increased turbulence level was developed and it leads to some improvement of the predictions; this approach requires practically no additional computational effort and it relates the effective thermal diffusivity to the mean effective velocity of the fluid at each particular height of the system. Altogether the study indicates that the selected parabolic trough-CSP plant has the edge over alternative competing technologies for locations where DNI is high and where land usage is not an issue, such as the shoreline of Libya.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Life Cycle Climate Performance (LCCP) is an evaluation method by which heating, ventilation, air conditioning and refrigeration systems can be evaluated for their global warming impact over the course of their complete life cycle. LCCP is more inclusive than previous metrics such as Total Equivalent Warming Impact. It is calculated as the sum of direct and indirect emissions generated over the lifetime of the system “from cradle to grave”. Direct emissions include all effects from the release of refrigerants into the atmosphere during the lifetime of the system. This includes annual leakage and losses during the disposal of the unit. The indirect emissions include emissions from the energy consumption during manufacturing process, lifetime operation, and disposal of the system. This thesis proposes a standardized approach to the use of LCCP and traceable data sources for all aspects of the calculation. An equation is proposed that unifies the efforts of previous researchers. Data sources are recommended for average values for all LCCP inputs. A residential heat pump sample problem is presented illustrating the methodology. The heat pump is evaluated at five U.S. locations in different climate zones. An excel tool was developed for residential heat pumps using the proposed method. The primary factor in the LCCP calculation is the energy consumption of the system. The effects of advanced vapor compression cycles are then investigated for heat pump applications. Advanced cycle options attempt to reduce the energy consumption in various ways. There are three categories of advanced cycle options: subcooling cycles, expansion loss recovery cycles and multi-stage cycles. The cycles selected for research are the suction line heat exchanger cycle, the expander cycle, the ejector cycle, and the vapor injection cycle. The cycles are modeled using Engineering Equation Solver and the results are applied to the LCCP methodology. The expander cycle, ejector cycle and vapor injection cycle are effective in reducing LCCP of a residential heat pump by 5.6%, 8.2% and 10.5%, respectively in Phoenix, AZ. The advanced cycles are evaluated with the use of low GWP refrigerants and are capable of reducing the LCCP of a residential heat by 13.7%, 16.3% and 18.6% using a refrigerant with a GWP of 10. To meet the U.S. Department of Energy’s goal of reducing residential energy use by 40% by 2025 with a proportional reduction in all other categories of residential energy consumption, a reduction in the energy consumption of a residential heat pump of 34.8% with a refrigerant GWP of 10 for Phoenix, AZ is necessary. A combination of advanced cycle, control options and low GWP refrigerants are necessary to meet this goal.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aquaculture has been expanded rapidly to become a major commercial and food-producing sector worldwide in recent decade. In parallel, viral diseases rapidly spread among farms causing enormous economic losses. The accurate detection of pathogens at early stages of infection is a key point for disease control in aquaculture. Spring Viraemia of Carp Virus (SVCV) is a very severe pathogen of carp fishes in different parts of the world and is categorized as a reportable listed disease in the annual published list of World Organization for animal Health (OIE). The objective of this study was to develop and evaluate RT- PCR test for detecting SVC virus and also the sensitivity and specificity of this test. A semi nested RT- PCR was designed using combination of three primers: two external (SVCF , SVCR) and one internal (SVCS) primers which based on conserved region of G gen. The specificity of designed primers (only external ones) by examination on Viral Hemorrhagic Septicemia Virus (VHSV) and Infectious Hematopoietic Necrosis Virus (IHNV) was confirmed. For optimizing of the PCR test, primer concentration, primer annealing temperature, cycle number and Mgcl2 concentration were surveyed. Also for validity test, prevention of false negative and Assurance of its accuracy, a competitive internal control (mimic) designed and its suitable concentration was defined. Evaluation of the sensitivity of designed test were conducted first by comparing the different commercially available RNA isolation guidelines, two guidelines: isotiocyanate phenol–chloroform based protocols (RNX–Plus Iran, Iq2000 kit Taiwan ) and two column based protocols (Cinna pure RNA Iran , high pure viral RNA kit, Roche Germany ). The results indicated that the column based protocols (Roche method and Cinna pure), yield 36.77 ng/μl and 16/47 ng/μl RNA concentration respectively, which were significantly higher than other protocols(P<0.05). Then for evaluation of extracted RNA sensitivity, Serial dilution of SVCV strain 56.70 grown in EPC (1.9×105 TCID50/ml) was examined To compare sensitivity. Extracted RNA from serial dilution with stone's primers and commercial IQ-2000 kit were examined simultaneously. The result indicated that designed semi- nested RT- PCR was able to recognize SVC virus to 10-4 dilution and stone's primer recognize to 10-3 dilution whereas Iq-2000 commercial kit did not recognized in any dilution. In high virus titer in designed test two DNA band (462 bp and 266 bp) produced, and by decreasing virus titer 462 bp was omitted. In low virus titer or lack of virus, just DNA band (mimic) 729 bp can propagate. After designing and optimizing PCR test, a total of 400 suspected cultured Cyprinus carpio with high mortality from 4 aquaculture zone of Khuzestan province were collected and tested for SVCV during 2012- 2013 using developed PCR method and IQ- 2000. The results indicated that SVC virus was not observed in samples using both methods.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The external evaluation of non-higher education schools in Portugal has been developed by the General Inspectorate of Education since 2006. A first cycle of evaluation was completed, covering all educational units in continental Portugal up to 2011. The model of evaluation has since been subject to alterations, and a second cycle of evaluation is now coming to an end. The current model of evaluation is based on documental analysis, analysis of students’ results, and panel interviews with a variety of representatives of the school community, and addresses three domains: results, provision of educational service and management. This paper is part of an ongoing research project, developed by 6 universities and supported by the Portuguese Foundation for Science and Technology (PTDC/CPE-CED/116674/2010) which intends to analyse the impacts and effects this process of external evaluation has had on Portuguese schools. This project includes a variety of perspectives and methodologies. In particular, we will focus on two case studies undertaken in two schools from the northern region of Portugal, and more specifically on the perspectives expressed by the teachers of those schools. These particular schools were chosen because they have been evaluated twice and represent different educational levels (basic and secondary), contexts and results. These case studies included the analysis of documental data, interviews to key informants and a questionnaire directed to teachers (n = 141) – the latter will be the main focus of this paper. Teachers are essential elements of the school community when considering the impacts of external evaluation, as any changes directed at teaching practices, student evaluation, among others are only possible through their direct action and implication. Therefore, their perceptions on the process and its impacts are crucial to the understanding of what does and does not change in schools as a consequence of external evaluation. Although teachers’ opinions are not homogenous and each school reveals a number of differences when it comes to teachers’ perceptions of School Evaluation, it was possible to stress some areas as the most and as the least consensual. Teachers in both schools agree External School Evaluation (ESE) is useful for the identification of the schools’ strengths and weaknesses, values students’ external evaluation results, imposes a model for schools internal evaluation (and in fact contributes to the very existence of internal evaluation practices), and contributes to schools improvement. However teachers in both schools do not believe ESE contributes to teachers’ autonomy produces changes in how curriculum is managed, or leads to innovative teaching practices. These results point to a greater emphasis on change at the levels of school management, self-evaluation and particularly internal evaluation, but little impact on the teaching practices. We believe the classroom is at the core of school practices and teaching processes are essential to any measure of school quality and to their impacts on student learning.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An innovative approach to quantify interest rate sensitivities of emerging market corporates is proposed. Our focus is centered at price sensitivity of modeled investment grade and high yield portfolios to changes in the present value of modeled portfolios composed of safe-haven assets, which define risk-free interest rates. Our methodology is based on blended yield indexes. Modeled investment horizons are always kept above one year thus allowing to derive empirical implications for practical strategies of interest rate risk management in the banking book. As our study spans over the period 2002 – 2015, it covers interest rate sensitivity of assets under the pre-crisis, crisis, and post-crisis phases of the economic cycles. We demonstrate that the emerging market corporate bonds both, investment grade and high yield types, depending on the phase of a business cycle exhibit diverse regimes of sensitivity to interest rate changes. We observe switching from a direct positive sensitivity under the normal pre-crisis market conditions to an inverted negative sensitivity during distressed turmoil of the recent financial crisis, and than back to direct positive but weaker sensitivity under new normal post-crisis conjuncture. Our unusual blended yield-based approach allows us to present theoretical explanations of such phenomena from economics point of view and helps us to solve an old controversy regarding positive or negative responses of credit spreads to interest rates. We present numerical quantification of sensitivities, which corroborate with our conclusion that hedging of interest rate risk ought to be a dynamic process linked to the phases of business cycles as we evidence a binary-like behavior of interest rate sensitivities along the economic time. Our findings allow banks and financial institutions for approaching downside risk management and optimizing economic capital under Basel III regulatory capital rules.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Rapport de stage présenté à la Faculté des sciences infirmières en vue de l’obtention du grade de maîtrise (M.Sc.) en sciences infirmières, option formation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The attention on green building is driven by the desire to reduce a building’s running cost over its entire life cycle. However, with the use of sustainable technologies and more environmentally friendly products in the building sector, the construction industry contributes significantly to sustainable actions of our society. Different certification systems have entered the market with the aim to measure a building’s sustainability. However, each system uses its own set of criteria for the purpose of rating. The primary goal of this study is to identify a comprehensive set of criteria for the measurement of building sustainability, and therefore to facilitate the comparison of existing rating methods. The collection and analysis of the criteria, identified through a comprehensive literature review, has led to the establishment of two additional categories besides the 3 pillars of sustainability. The comparative analyses presented in this thesis reveal strengths and weaknesses of the chosen green building certification systems - LEED, BREEAM, and DGNB.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND African swine fever (ASF) is one of the most complex viral diseases affecting both domestic and wild pigs. It is caused by ASF virus (ASFV), the only DNA virus which can be efficiently transmitted by an arthropod vector, soft ticks of the genus Ornithodoros. These ticks can be part of ASFV-transmission cycles, and in Europe, O. erraticus was shown to be responsible for long-term maintenance of ASFV in Spain and Portugal. In 2014, the disease has been reintroduced into the European Union, affecting domestic pigs and, importantly, also the Eurasian wild boar population. In a first attempt to assess the risk of a tick-wild boar transmission cycle in Central Europe that would further complicate eradication of the disease, over 700 pre-existing serum samples from wild boar hunted in four representative German Federal States were investigated for the presence of antibodies directed against salivary antigen of Ornithodoros erraticus ticks using an indirect ELISA format. RESULTS Out of these samples, 16 reacted with moderate to high optical densities that could be indicative of tick bites in sampled wild boar. However, these samples did not show a spatial clustering (they were collected from distant geographical regions) and were of bad quality (hemolysis/impurities). Furthermore, all positive samples came from areas with suboptimal climate for soft ticks. For this reason, false positive reactions are likely. CONCLUSION In conclusion, the study did not provide stringent evidence for soft tick-wild boar contact in the investigated German Federal States and thus, a relevant involvement in the epidemiology of ASF in German wild boar is unlikely. This fact would facilitate the eradication of ASF in the area, although other complex relations (wild boar biology and interactions with domestic pigs) need to be considered.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Rapport de stage présenté à la Faculté des sciences infirmières en vue de l’obtention du grade de maîtrise (M.Sc.) en sciences infirmières, option formation.