969 resultados para Erythrocytes interferences
Resumo:
Staphylococcus aureus binds Immunoglobulin G (IgG) on its external surface due to the presence of specific receptors for the Fc domain of this immunoglobulin. This mechanism represents a kind of camouflage against phagocytic cells. In order to confirm that possibility an in vitro evaluation of the phagocytic activity of leukocytes polymorpho-nuclear (PMN) against strains of Staphylococcus aureus was done, comparing 18 strains isolated from clinical samples and 16 from healthy individuals. The presence of Fc receptors was evaluated by haemagglutination (HA) with erythrocytes group A after incubation of the strains with IgG anti blood group A. Phagocytosis of S. aureus was carried out by mixing live bacteria with a suspension of human PMN and incubating at 37 °C for 1 h; survivors were counted as colony forming units by plating. The strains from clinical specimens showed higher HA than those from healthy individuals (p = 0.01); but the former were killed more efficiently than the latter (80-90% and 40%, respectively). It is may be possible that S. aureus showed different behavior in vivo, where could express other virulence factors to prevent the action of phagocytes.
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Biomédica
Resumo:
Previous experiences have demonstrated the same ABO system and P system antigens in A. lumbricoides extracts and in their hosts. The aim was to show the behavior of an A. lumbricoides extract from an O Group patient against monoclonal antibodies of different specificities. Agglutination Inhibition Tests were carried out facing the extract against monoclonal antibodies (anti A 2.23; anti B 2.54; anti B 2.62; anti AB 2.39 and anti H 2.72) in optimal concentrations. Suspensions of O Group fresh red cells were used as revealing system. The extract only inhibited the agglutination of anti H 2.72 with O erythrocytes. The semiquantitative Agglutination Inhibition Test of the extract was made against two series of anti H 2.72 dilutions by using O Group fresh red cells as revealing system. A difference of five dilutions between the titers of both series has been observed and the presence of H Antigen in the extract has been significantly confirmed. The fact that the extract did not inhibit the agglutination against anti A, anti B and anti AB has corroborated our previous observations about absence of A and B epitopes in A. lumbricoides extracts from O Group patients. The results of the preceding studies and this experience have demonstrated the membrane glycoconjugated importance in A. lumbricoides. They could be involved in molecular mimicry for this parasite.
Resumo:
Antibody in human sera that induces lysis of sheep erythrocytes in hemolytic assay was investigated. The present study showed that the presence in serum of the thermostable cytolytic anti-sheep red blood cells antibodies is dependent on the Schistosoma mansoni infection, and this is more frequent in adults than in children. The thermostable characteristic of hemolysins in normal sera was not dependent on the presence of Ascaris lumbricoides, Trichuris trichiura or hookworm geo-helminths. Further, thermostable complement-activating heterophile antibodies were noticed in children in association with massive number of S. mansoni eggs. The results were obtained by using the z- and the chi-square tests. The z-test allows us to formulate a one-sided alternative, i.e., a tendency of one of the attributes. On the other hand, the chi-square test analyzes the independence between attributes by using a contingency table. Besides the obtained results being interesting in the field of schistosomiasis mansoni, they can provide a new insight into the use of statistics in medical science.
Resumo:
Eight new peptides were isolated from the skin secretion of the frog Leptodactylus pustulatus and their amino acid sequences determined by de novo sequencing and by cDNA cloning. Structural similarities between them and other antimicrobial peptides from the skin secretion of Leptodactylus genus frogs were found. Ocellatins-PT1 to -PT5 (25 amino acid residues) are amidated at the C-terminus, while ocellatins-PT6 to -PT8 (32 amino acid residues) have free carboxylates. Antimicrobial activity, hemolytic tests, and cytotoxicity against a murine fibroblast cell line were investigated. All peptides, except for ocellatin-PT2, have antimicrobial activity against at least one Gram negative strain. Ocellatin-PT8 inhibited the growth of Escherichia coli, Staphylococcus aureus, Klebsiella pneumoniae, and Salmonella choleraesuis strains with MICs in the 60−240 μM range. No significant effect was observed in human erythrocytes and in a murine fibroblast cell line after exposure to the peptides at MICs. A comparison between sequences obtained by both direct HPLC-MS de novo sequencing and cDNA cloning demonstrates the secretion of mature peptides derived from a pre-pro-peptide structure.
Resumo:
For the first time, a glassy carbon electrode (GCE) modified with novel N-doped carbon nanotubes (CNT-N) functionalized with MnFe2O4 nanoparticles (MnFe2O4@CNT-N) has been prepared and applied for the electrochemical determination of caffeine (CF), acetaminophen (AC) and ascorbic acid (AA). The electrochemical behaviour of CF, AC and AA on the bare GCE, CNT-N/GCE and MnFe2O4@CNT-N/GCE were carefully investigated using cyclic voltammetry (CV) and square-wave voltammetry (SWV). Compared to bare GCE and CNT-N modified electrode, the MnFe2O4@CNT-N modified electrode can remarkably improve the electrocatalytic activity towards the oxidation of CF, AC and AA with an increase in the anodic peak currents of 52%, 50% and 55%, respectively. Also, the SWV anodic peaks of these molecules could be distinguished from each other at the MnFe2O4@CNT-N modified electrode with enhanced oxidation currents. The linear response ranges for the square wave voltammetric determination of CF, AC and AA were 1.0 × 10−6 to 1.1 × 10−3 mol dm−3, 1.0 × 10−6 to 1.0 × 10−3 mol dm−3 and 2.0 × 10−6 to 1.0 × 10−4 mol dm−3 with detection limit (S/N = 3) of 0.83 × 10−6, 0.83 × 10−6 and 1.8 × 10−6 mol dm−3, respectively. The sensitivity values at the MnFe2O4@CNT-N/GCE for the individual determination of AC, AA and CF and in the presence of the other molecules showed that the quantification of AA and CF show no interferences from the other molecules; however, AA and CF interfered in the determination of AC, with the latter molecule showing the strongest interference. Nevertheless, the obtained results show that MnFe2O4@CNT-N composite material acted as an efficient electrochemical sensor towards the selected biomolecules.
Resumo:
The development and application of a polyaniline/carbon nanotube (CNT) cyclodextrin matrix (PANI-β-CD/MWCNT)-based electrochemical sensor for the quantitative determination of the herbicide 4-chloro-2-methylphenoxyacetic acid (MCPA) and its main transformation product 4-chloro-2-methylphenol in natural waters are described. A simple cyclic voltammetry-based electrochemical methodology, in phosphate buffer solution at pH 6.0, was used to develop a method to determine both MCPA and 4-chloro-2-methylphenol, without any previous extraction or derivatization steps. A linear concentration range (10 to 50 μmol L−1) and detection limits of 1.1 and 1.9 μmol L−1, respectively, were achieved using optimized cyclic voltammetric parameters. The proposed method was successfully applied to the determination of MCPA and 4-chloro-2-methylphenol in natural water samples with satisfactory recoveries (94 to 107 %) and in good agreement with the results obtained by an established high-performance liquid chromatography technique, no significant differences being found between the methods. Interferences from ionic species and other herbicides used for broad-leaf weed control were shown to be small. The newly developed methodology was also successfully applied to MCPA photodegradation environmental studies.
Resumo:
An electronmicroscopy study of the spleen from mice infected with Plasmodium berghei was carried out to investigate the types ofcells in volved in the removal of parasites from the blood, and the mechanisms by which this occurs. Macrophages, particularly from the red pulp and the marginal zone of the spleen, constituted the most important population of phagocytic cells in the spleen. At the height ofparasitaemia, macrophages in the periphery of the white pulp, especially in the mantle zone of secondary follicles, were also found to participate in phagocytosis, although to a limited extent. Our fingings suggest that phagocytosis of free parasites or parasitized erythrocytes in the spleen is an important mechanism of clearance of parasites from the circulation. Parasites removed from the erythrocytes when these cells cross the interendothelial slits are further phagocytosed by neighbouring macrophages. Evidence is presented suggesting that spleen macrophages may act against the parasite through a process of cytotoxicity.
Resumo:
RESUMO: A Diabetes Mellitus é uma doença metabólica crónica, com deficiência a nível do metabolismo dos hidratos de carbono, lípidos e proteínas, resultante de deficiências na secreção ou ação da insulina, ou de ambas, que quando não tratada antecipadamente e de modo conveniente, pode ter consequências muito graves. Dado a incidência a nível mundial da Diabetes Mellitus, torna-se de elevada importância avaliar toda a sua envolvência e estudar bem quais os critérios a ter em consideração. Este trabalho propõe-se estudar para além dos parâmetros bioquímicos relacionados com a doença - Glicose e Hemoglobina Glicada A1c (HbA1c), analisar os resultados dos últimos cinco anos (2008-2012) dos ensaios interlaboratoriais do PNAEQ, do Departamento de Epidemiologia, do Instituto Nacional de Saúde Dr. Ricardo Jorge. Foram também analisadas as metodologias utilizadas e as variações interlaboratoriais, de forma a entender qual ou quais são os parâmetros mais adequados para o seu diagnóstico e controlo. Este estudo utilizou a população de laboratórios portugueses, públicos e privados, de Portugal Continental e Ilhas, um laboratório de Angola e outro de Macau que se inscreveram no PNAEQ nestes cinco anos, sendo a amostra composta pelo n.º de participações. No programa de Química Clinica foram distribuídas 38 amostras e no programa de HbA1c foram distribuídas 22 amostras. Para a glicose, o nível de desempenho nos ensaios é na globalidade das amostras de Excelente, no entanto verifica-se que sempre que a concentração da amostra é de nível patológico, que a maioria dos ensaios o desempenho foi inferior – Bom. O método de eleição e com CV% mais baixos foi o método da hexoquinase. Para a HbA1c, o nível de desempenho nos ensaios é na globalidade das amostras de Excelente. O método de eleição e com CV% mais baixos foi o método de HPLC. O CV% para a glicose ronda desde 2010 a 2012, os 3% e para a HbA1c foi de aproximadamente 4,0% em 2012. A HbA1c tem mostrado ser uma ferramenta muito útil, importante e robusta na monitorização da Diabetes, sendo hoje em dia quase sempre requisitada em análises de rotina a diabéticos de modo a prevenir complicações que possam vir a acorrer. No futuro poderá ser um importante, senão o parâmetro de futuro, para o diagnóstico da Diabetes, no entanto, mesmo já tendo sido muito trabalhada a sua padronização, ainda existem questões por responder como quais são na realidade todos os seus interferentes, qual a verdadeira relação da HbA1c com a glicose média estimada, em todas as populações e com estudos epidemiológicos. Também a própria educação do diabético e clínico deve ser aprimorada, pelo que neste momento as PTGO e os doseamentos de glicose em jejum devem ser utilizados e encontrando-se a Norma da DGS N.º 033/2011 de acordo com as necessidades e com o estado da arte deste parâmetro. A implementação da glicose média estimada será uma mais-valia na monitorização dos diabéticos pelo que deverá ser uma das prioridades a ter em conta no futuro desta padronização, uniformizando a decisão clinica baseada nela e minimizando a dificuldade de interpretação de resultados de laboratório para laboratório. --------------ABSTRACT: Diabetes Mellitus is a chronic metabolic disease, with a deficit in the metabolism of carbohydrates, lipids and proteins, resulting from deficiencies in insulin secretion or action, or both, which if, when not early treated in a proper way, may result in very serious consequences. Given the worldwide incidence of diabetes mellitus, it is highly important to evaluate all its background and study specifically all the criteria to take into consideration. The aim of this thesis is to study and evaluate beyond the biochemical parameters related to the disease - Glucose and Glycated Haemoglobin A1c (HbA1c), analyze the results of the last five years (2008-2012) of the PNAEQ interlaboratorial tests, in the Department of Epidemiology of National Institute of Health Dr. Ricardo Jorge. It is also intended to analyze the methodologies used and the interlaboratorial variations, in order to understand the most suitable parameters for the diagnosis and control. This study was based in a population of Portuguese laboratories, public and private, of Portugal mainland and islands, a laboratory of Angola and other from Macau, who enrolled in PNAEQ in these five years, and the sample was composed by the n. º of holdings. In the Clinical Chemistry Program there were distributed 38 samples and in the program HbA1c were distributed 22 samples. For glucose, the level of performance in the total nº of the samples was Excellent; however, it was found that when the concentration level of the sample was pathological, in most of the tests the performance was Good. The most preferred method with the lowest CV% is the hexokinase method. For the HbA1c, as a whole, the samples’ tests were Excellent, at the level of performance. The method of election with the lower CV% was the HPLC. The CV% for glucose was around 3%, from 2010 to 2012 and the HbA1c was approximately 4.0% in 2012. The HbA1c method has demonstrated to be a very useful tool, important and robust for monitoring diabetes, being nowadays, almost always required in routine analysis to prevent future complications. In the future it may be an important parameter, if not the most important, for the diagnosis of diabetes. However, despite it has already been standardized, there are still some questions that need to be answered, such as, which are in fact all their interferences, which is the true connection of HbA1c, when compared with the estimated average glucose, in all populations and epidemiological studies. Moreover, the education of the patient and the doctor concerning diabetes should be improved. Nowadays, the Oral Glucose Tolerance Test (OGTT) and fasting glucose determinations should be used and, the needs and the state of the art of this parameter, should be in accordance with the Standard DGS N. º 033/2011. The Implementation of the estimated average glucose will be an added value in monitoring diabetics and, therefore, should be a priority to consider in its future standardization and clinical decision based on it, will be uniform and the difficulty of interpreting results from laboratory to laboratory will be minimal.
Resumo:
RESUMO: A Medicina Transfusional está a mudar rapidamente em resposta a um número de diferentes catástrofes, patologias e novas técnicas da ciência. Por detrás de uma transfusão de sangue existe todo um conjunto de procedimentos, técnicas e atuações que salvaguardam o rigor e segurança científicas resultando numa maior eficiência na diminuição da morbilidade/mortalidade humana. Todo o processo de colheita, análise, processamento e distribuição de concentrados de eritrócitos comporta um capital elevado em termos da economia para a saúde e os requisitos básicos de uma gestão de qualidade, na área da saúde em geral e da hemoterapia em particular, tem de compreender, com rigor, estas condições de gestão parceria de forma a evitar um aumento nos custos da saúde. Para identificar as discrepâncias nos pedidos efetuados pelos Hospitais Públicos e Privados ao Centro de Sangue e Transplantação de Lisboa, no que diz respeito ao Sistema AB0 dos concentrados de Eritrócitos, foi feito um estudo quantitativo, com fins descritivos simples, aos 95 984 concentrados de eritrócitos enviados às 32 Instituições de Saúde da abrangência do CST de Lisboa. Tendo em conta o Sistema AB0 RhD, confirma-se que o grupo sanguíneo prevalente, tanto na população portuguesa como nos dadores de sangue que efetuaram a sua dádiva de sangue em 2011, é o grupo A Rh+. Observou-se no entanto que o grupo sanguíneo mais pedido e enviado pertence ao grupo 0 Rh positivo. Assim, apurou-se que existe uma disparidade, mesmo que pouco acentuada, nos pedidos efetuados pelos Hospitais Públicos e Privados ao Centro de Sangue e Transplantação de Lisboa no que configura ao Sistema AB0 dos concentrados de eritrócitos. Os Hospitais Públicos Sem Serviço de Colheita de Sangue e os Hospitais Privados são responsáveis por este desencontro de valores. No que se refere às inutilizações por prazo de validade ressalva-se que os desaproveitamentos de CE’s não são tão acentuados como se esperaria numa primeira fase de estudo. No entanto, e em termos económicos, se existem inutilizações por prazo de validade, existe igualmente despojo financeiro. Por detrás de cada unidade inutilizada existe um alto investimento que será desperdiçado por carência de solicitação. De forma a minimizar gastos e a salvaguardar um Banco de Sangue capaz de suportar qualquer eventualidade de rutura de stock estão patentes propostas de estratégias capazes de impedir constrangimentos diários e futuros no que diz respeito à disponibilidade de sangue e componentes sanguíneos.--------------ABSTRACT: The Transfusion Medicine it is changing fast in response to a number of different catastrophes, disease and new techniques of science. From behind a blood transfusion there is a whole set of procedures, techniques and actions that safeguard the safety and scientific rigor resulting in greater efficiency in reducing morbidity / mortality human. The entire process of procurement, testing, processing and distribution of concentrated erythrocytes involves a high capital in terms of the economy to health and the basic requirements of a quality management in healthcare in general and hemotherapy in particular has to understand with rigor, this partnership in order to avoid an increase in health costs. In order to identify discrepancies in the orders placed by the Government and Private Hospitals Center Blood and Transplant Lisbon regarding the AB0 system of concentrated erythrocytes was made a quantitative study with simple descriptive purposes to 95,984 erythrocytes concentrates sent to 32 Health Institutions of the scope of CST Lisbon. Having regard to the system AB0 blood group RhD prevalent both in the Portuguese population as blood donors, who made his blood donation in 2011, confirms that belong to group A Rh +. It was found that blood group most requested and sent belongs to group 0 Rh positive. Thus, it was found that there is a disparity, even a little sharp, requests made by the Government and Private Hospitals Blood Center and Transplantation in Lisbon that configures the system AB0 erythrocyte concentrates. The Public Hospitals without Blood Harvest and Private Hospitals are responsible for this clash of values. With regard the expiry date by disables proviso that the wastes of CE's are not as sharp as one would expect in a first phase of the study. However, in economic terms, if there is disables by expiry date, there is also financial squandering. Behind every unused unit is a high investment to be wasted by shortage of request. To minimize costs and safeguarding a Blood Bank can support any event of rupture of stock patents are proposed strategies to prevent future and diaries constraints with regard to the availability of blood and blood components.
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Biomédica
Resumo:
We have compared Duffy blood group genotype distribution, as determined by polymerase chain reaction with allele-specific primers, in 68 Plasmodium vivax-infected patients and 59 non-vivax malaria controls from Rondônia, Brazil. Homozygosity for the allele Fy, which abolishes Duffy antigen expression on erythrocytes, was observed in 12% non-vivax controls but in no P. vivax patient. However, no significant association was found between Fy heterozygosity and protection against P. vivax. The Fy x allele, which has recently been associated with very weak erythrocyte expression of Duffy antigen, was not found in local P. vivax patients.
Resumo:
The search for a colorless, nontoxic and efficient drug to prevent transfusion-associated Chagas' disease (TACD) has been underway unsuccessfully since 1953 when gentian violet was preconized and to date is still being used as the only in vitro trypanocidal agent. The recent findings of aminoquinolone "WR6026" as a trypanocidal agent, led the authors to study the metabolism of red cells stored with this compound, the main objective of which was to define its applicability in TACD control. Ten units of human whole blood collected in CPDA-1 were divided into two equal satellite bags. One had "WR6026" (final concentration 62.5µg/mL) added and the other was used as a control, both were stored at 4ºC. At baseline, day 7, 14, 21 and 28, samples were taken for the following measurements: adenosine triphosphate (ATP), hemoglobin, electrolytes (sodium and potassium), gases (pO2 and pCO2) and osmotic fragility. The results of tests and control were analyzed through parametric t-student test. The results were similar in both groups throughout the experiment except for the level of ATP on day 14, which presented significantly higher values in the tests when compared with the controls (p = 0.012). It was concluded that WR6026 does not interfere in the preservation and probably the viability of the erythrocytes also until day 28 of storage. Consequently the authors suggest that WR6026 could emerge as a colorless substitute for gentian violet in the control of TACD in endemic areas.
Resumo:
Dissertação para obtenção do Grau de Mestre em Genética Molecular e Biomedicina
Resumo:
RESUMO: O impacto da fase pré-analítica nos resultados é o objectivo do nosso trabalho. Considera-se que esta fase é a mais importante no procedimento do teste no laboratório e que as variáveis independentes do laboratório são difíceis de controlar porque existem várias condicionantes quer dos profissionais, quer do doente, que por vezes não possibilita atribuir a importância desejada para que os resultados sejam fiáveis. De que modo a fase pré-analítica pode interferir nos resultados de um trabalho de investigação. Para podermos avaliar este processo é necessário considerar outra condicionante, nomeadamente, o facto de o teste ser realizado em laboratórios específicos com a qualidade certificada mas que não intervêm na colheita, manuseamento, armazenamento e transporte da amostra, procedimentos importantes que traduzem uma boa gestão da amostra na fase pré-analítica, necessária para a fiabilidade dos resultados dos estudos de investigação clínica.------------------ABSTRACT: The impact of pre-analytical phase in the results is the objective of our work Knowing that, this is the most important stage in the procedure of testing in the laboratory and because the independent variables the laboratory are difficult to control because these are several limitations of both the professional and the patient, sometimes does not assign importance to that desired result are reliable. How the pre-analytical phase can interfere with the result of a research work, there is another constraint to consider the testing process to be performed in individual laboratory with certified quality, but not involved in harvesting, handing, storage and transport of the sample, important procedures that translate a good sample management in the preanalytical phase, necessary for the reliability of results of clinical research studies.