996 resultados para Endodontics - Instrumentation
Resumo:
One goal of interbody fusion is to increase the height of the degenerated disc space. Interbody cages in particular have been promoted with the claim that they can maintain the disc space better than other methods. There are many factors that can affect the disc height maintenance, including graft or cage design, the quality of the surrounding bone and the presence of supplementary posterior fixation. The present study is an in vitro biomechanical investigation of the compressive behaviour of three different interbody cage designs in a human cadaveric model. The effect of bone density and posterior instrumentation were assessed. Thirty-six lumbar functional spinal units were instrumented with one of three interbody cages: (1) a porous titanium implant with endplate fit (Stratec), (2) a porous, rectangular carbon-fibre implant (Brantigan) and (3) a porous, cylindrical threaded implant (Ray). Posterior instrumentation (USS) was applied to half of the specimens. All specimens were subjected to axial compression displacement until failure. Correlations between both the failure load and the load at 3 mm displacement with the bone density measurements were observed. Neither the cage design nor the presence of posterior instrumentation had a significant effect on the failure load. The loads at 3 mm were slightly less for the Stratec cage, implying lower axial stiffness, but were not different with posterior instrumentation. The large range of observed failure loads overlaps the potential in vivo compressive loads, implying that failure of the bone-implant interface may occur clinically. Preoperative measurements of bone density may be an effective tool to predict settling around interbody cages.
Resumo:
Since the introduction of cone beam computed tomography (CBCT), this 3-dimensional diagnostic imaging technique has been established in a growing number of fields in dental medicine. It has become an important tool for both diagnosis and treatment planning, and is also able to support endodontic treatments. However, the higher effective dose of ionizing radiation compared to conventional 2-dimensional radiographs is not justifiable in every case. CBCT allows for a more precise diagnosis of periapical lesions, root fractures as well as external and internal resorptions. Concerning the utility of CBCT in treatment planning decisions, the gain of information through 3-dimensional imaging for any of these pathologies has to be evaluated carefully on an individual basis. Moreover, radioopaque materials such as root canal filling and posts often create artefacts, which may compromise diagnosis. The aim of this review is to summarize the possibilities and limits of CBCT imaging in endodontology as well as introduce guidelines for daily clinical practice. Furthermore, the article presents possible therapeutic advantages of preexisting CBCT scans for root canal treatments.
Resumo:
BACKGROUND CONTEXT A new device, DensiProbe, has been developed to provide surgeons with intraoperative information about bone strength by measuring the peak breakaway torque. In cases of low bone quality, the treatment can be adapted to the patient's condition, for example, by improving screw-anchorage with augmentation techniques. PURPOSE The objective of this study was to investigate the feasibility of DensiProbe Spine in patients undergoing transpedicular fixation. STUDY DESIGN Prospective feasibility study on consecutive patients. PATIENT SAMPLE Fourteen women and 16 men were included in this study. OUTCOME MEASURES Local and general bone quality. METHODS These consecutive patients scheduled for transpedicular fixation were evaluated for bone mineral density (BMD), which was measured globally by dual-energy X-ray absorptiometry and locally via biopsies using quantitative microcomputed tomography. The breakaway torque force within the vertebral body was assessed intraoperatively via the transpedicular approach with the DensiProbe Spine. The results were correlated with the areal BMD at the lumbar spine and the local volumetric BMD (vBMD) and a subjective impression of bone strength. The feasibility of the method was evaluated, and the clinical and radiological performance was evaluated over a 1-year follow-up. This study was funded by an AO Spine research grant; DensiProbe was developed at the AO Research Institute Davos, Switzerland; the AO Foundation is owner of the intellectual property rights. RESULTS In 30 patients, 69 vertebral levels were examined. The breakaway torque consistently correlated with an experienced surgeon's quantified impression of resistance as well as with vBMD of the same vertebra. Beyond a marginal prolongation of surgery time, no adverse events related to the usage of the device were observed. CONCLUSIONS The intraoperative transpedicular measurement of the peak breakaway torque was technically feasible, safe, and reliably predictive of local vBMD during dorsal spinal instrumentations in a clinical setting. Larger studies are needed to define specific thresholds that indicate a need for the augmentation or instrumentation of additional levels.
Resumo:
This year marks the 20th anniversary of functional near-infrared spectroscopy and imaging (fNIRS/fNIRI). As the vast majority of commercial instruments developed until now are based on continuous wave technology, the aim of this publication is to review the current state of instrumentation and methodology of continuous wave fNIRI. For this purpose we provide an overview of the commercially available instruments and address instrumental aspects such as light sources, detectors and sensor arrangements. Methodological aspects, algorithms to calculate the concentrations of oxy- and deoxyhemoglobin and approaches for data analysis are also reviewed. From the single-location measurements of the early years, instrumentation has progressed to imaging initially in two dimensions (topography) and then three (tomography). The methods of analysis have also changed tremendously, from the simple modified Beer-Lambert law to sophisticated image reconstruction and data analysis methods used today. Due to these advances, fNIRI has become a modality that is widely used in neuroscience research and several manufacturers provide commercial instrumentation. It seems likely that fNIRI will become a clinical tool in the foreseeable future, which will enable diagnosis in single subjects.
Resumo:
PURPOSE Currently, the diagnosis of pedicle screw (PS) loosening is based on a subjectively assessed halo sign, that is, a radiolucent line around the implant wider than 1 mm in plain radiographs. We aimed at development and validation of a quantitative method to diagnose PS loosening on radiographs. METHODS Between 11/2004 and 1/2010 36 consecutive patients treated with thoraco-lumbar spine fusion with PS instrumentation without PS loosening were compared with 37 other patients who developed a clinically manifesting PS loosening. Three different angles were measured and compared regarding their capability to discriminate the loosened PS over the postoperative course. The inter-observer invariance was tested and a receiver operating characteristics curve analysis was performed. RESULTS The angle measured between the PS axis and the cranial endplate was significantly different between the early and all later postoperative images. The Spearman correlation coefficient for the measurements of two observers at each postoperative time point ranged between 0.89 at 2 weeks to 0.94 at 2 months and 1 year postoperative. The angle change of 1.9° between immediate postoperative and 6-month postoperative was 75% sensitive and 89% specific for the identification of loosened screws (AUC = 0.82). DISCUSSION The angle between the PS axis and the cranial endplate showed good ability to change in PS loosening. A change of this angle of at least 2° had a relatively high sensitivity and specificity to diagnose screw loosening.
Resumo:
AIM To report on an intraradicular visual test in a simulated clinical setting under different optical conditions. METHODOLOGY Miniaturized visual tests with E-optotypes (bar distance from 0.01 to 0.05 mm) were fixed inside the root canal system of an extracted maxillary molar at different locations: at the orifice, a depth of 5 mm and the apex. The tooth was mounted in a phantom head for a simulated clinical setting. Unaided vision was compared with Galilean loupes (2.5× magnification) with integrated light source and an operating microscope (6× magnification). The influence of the dentists' age within two groups was evaluated: <40 years (n = 9) and ≥40 years (n = 15). RESULTS Some younger dentists were able to identify the E-optotypes at the orifice, but otherwise, natural vision did not reveal any measurable result. With Galilean loupes, the younger dentists <40 years could see a 0.05 mm structure at the root canal orifice, in contrast to the older group ≥40 years. Only the microscope allowed the observation of structures inside the root canal, independent of age. CONCLUSION Unaided vision and Galilean loupes with an integrated light source could not provide any measurable vision inside the root canal, but younger dentists <40 years could detect with Galilean loupes a canal orifice corresponding to the tip of the smallest endodontic instruments. Dentists over 40 years of age were dependent on the microscope to inspect the root canal system.
Resumo:
Concentrator photovoltaic is an emergent technology that may be a good economical and efficient alternative for the generation of electricity at a competitive cost. However, the reliability of these new solar cells and systems is still an open issue due to the high-irradiation level they are subjected to as well as the electrical and thermal stresses that they are expected to endure. To evaluate the reliability in a short period of time, accelerated aging tests are essential. Thermal aging tests for concentrator photovoltaic solar cells and systems under illumination are not available because no technical solution to the problem of reaching the working concentration inside a climatic chamber has been available. This work presents an automatic instrumentation system that overcomes the aforementioned limitation. Working conditions have been simulated by forward biasing the solar cells to the current they would handle at the working concentration (in this case, 700 and 1050 times the irradiance at one standard sun). The instrumentation system has been deployed for more than 10 000 h in a thermal aging test for III-V concentrator solar cells, in which the generated power evolution at different temperatures has been monitored. As a result of this test, the acceleration factor has been calculated, thus allowing for the degradation evolution at any temperature in addition to normal working conditions to be obtained.
Resumo:
Los métodos de detección rápida de microorganismos se están convirtiendo en una herramienta esencial para el control de calidad en el área de la biotecnología, como es el caso de las industrias de alimentos y productos farmacéuticos y bioquímicos. En este escenario, el objetivo de esta tesis doctoral es desarrollar una técnica de inspección rápida de microoganismos basada en ultrasonidos. La hipótesis propuesta es que la combinación de un dispositivo ultrasónico de medida y un medio líquido diseñado específicamente para producir y atrapar burbujas, pueden constituir la base de un método sensible y rápido de detección de contaminaciones microbianas. La técnica presentada es efectiva para bacterias catalasa-positivas y se basa en la hidrólisis del peróxido de hidrógeno inducida por la catalasa. El resultado de esta reacción es un medio con una creciente concentración de burbujas. Tal medio ha sido estudiado y modelado desde el punto de vista de la propagación ultrasónica. Las propiedades deducidas a partir del análisis cinemático de la enzima se han utilizado para evaluar el método como técnica de inspección microbiana. En esta tesis, se han investigado aspectos teóricos y experimentales de la hidrólisis del peróxido de hidrógeno. Ello ha permitido describir cuantitativamente y comprender el fenómeno de la detección de microorganismos catalasa-positivos mediante la medida de parámetros ultrasónicos. Más concretamente, los experimentos realizados muestran cómo el oxígeno que aparece en forma de burbujas queda atrapado mediante el uso de un gel sobre base de agar. Este gel fue diseñado y preparado especialmente para esta aplicación. A lo largo del proceso de hidrólisis del peróxido de hidrógeno, se midió la atenuación de la onda y el “backscattering” producidos por las burbujas, utilizando una técnica de pulso-eco. Ha sido posible detectar una actividad de la catalasa de hasta 0.001 unidades/ml. Por otra parte, este estudio muestra que por medio del método propuesto, se puede lograr una detección microbiana para concentraciones de 105 células/ml en un periodo de tiempo corto, del orden de unos pocos minutos. Estos resultados suponen una mejora significativa de tres órdenes de magnitud en comparación con otros métodos de detección por ultrasonidos. Además, la sensibilidad es competitiva con modernos y rápidos métodos microbiológicos como la detección de ATP por bioluminiscencia. Pero sobre todo, este trabajo muestra una metodología para el desarrollo de nuevas técnicas de detección rápida de bacterias basadas en ultrasonidos. ABSTRACT In an industrial scenario where rapid microbiological methods are becoming essential tools for quality control in the biotechnological area such as food, pharmaceutical and biochemical; the objective of the work presented in this doctoral thesis is to develop a rapid microorganism inspection technique based on ultrasounds. It is proposed that the combination of an ultrasonic measuring device with a specially designed liquid medium, able to produce and trap bubbles could constitute the basis of a sensitive and rapid detection method for microbial contaminations. The proposed technique is effective on catalase positive microorganisms. Well-known catalase induced hydrogen peroxide hydrolysis is the fundamental of the developed method. The physical consequence of the catalase induced hydrogen peroxide hydrolysis is an increasingly bubbly liquid medium. Such medium has been studied and modeled from the point of view of ultrasonic propagation. Properties deduced from enzyme kinematics analysis have been extrapolated to investigate the method as a microbial inspection technique. In this thesis, theoretical and experimental aspects of the hydrogen peroxide hydrolysis were analyzed in order to quantitatively describe and understand the catalase positive microorganism detection by means of ultrasonic measurements. More concretely, experiments performed show how the produced oxygen in form of bubbles is trapped using the new gel medium based on agar, which was specially designed for this application. Ultrasonic attenuation and backscattering is measured in this medium using a pulse-echo technique along the hydrogen peroxide hydrolysis process. Catalase enzymatic activity was detected down to 0.001 units/ml. Moreover, this study shows that by means of the proposed method, microbial detection can be achieved down to 105 cells/ml in a short time period of the order of few minutes. These results suppose a significant improvement of three orders of magnitude compared to other ultrasonic detection methods for microorganisms. In addition, the sensitivity reached is competitive with modern rapid microbiological methods such as ATP detection by bioluminescence. But above all, this work points out a way to proceed for developing new rapid microbial detection techniques based on ultrasound.
Resumo:
BACKGROUND As an alternative to the modified Stoppa approach, the Pararectus approach is used clinically for treatment of acetabular fractures involving the anterior column. The current study assessed the surgical exposure and the options for instrumentation using both of these approaches. METHODS Surgical dissections were conducted on five human cadavers (all male, mean age 88 years (82-97)) using the modified Stoppa and the Pararectus approach, with the same skin incision length (10cm). Distal boundaries of the exposed bony surfaces were marked using a chisel. After removal of all soft-tissues, distances from the boundaries in the false and true pelvis were measured with reference to the pelvic brim. The exposed bone was coloured and calibrated digital images of each inner hemipelvis were taken. The amount of exposed surface using both approaches was assessed and represented as a percentage of the total bony surface of each hemipelvis. For instrumentation, a suprapectineal quadrilateral buttress plate was used. Screw lengths were documented, and three-dimensional CT reconstructions were performed to assess screw trajectories qualitatively. Wilcoxon's signed rank test for paired groups was used (level of significance: p<0.05). RESULTS After utilization of the Pararectus approach, the distances from the farthest boundaries of exposed bone towards the pelvic brim were significantly higher in the false but not the true pelvis, compared to the modified Stoppa approach. The percentage (mean±SD) of exposed bone accessible after utilizing the Pararectus approach was 42±8%, compared to 29±6% using the modified Stoppa (p=0.011). In cadavers exposed by the Pararectus approach, screws placed for posterior fixation and as a posterior column screw were longer by factor 1.8 and 2.1, respectively (p<0.05), and screws could be placed more posteromedial towards the posterior inferior iliac spine or in line with the posterior column directed towards the ischial tuberosity. CONCLUSION Compared to the modified Stoppa, the Pararectus approach facilitates a greater surgical access in the false pelvis, provides versatility for fracture fixation in the posterior pelvic ring and allows for the option to extend the approach without a new incision.