977 resultados para ELEVATED INTRAOCULAR-PRESSURE
Resumo:
PURPOSE: To report the use of argon laser iridoplasty in the management of uveitic acute angle-closure glaucoma. METHODS: Interventional case report. RESULTS: A 46-year-old man developed uveitic acute angle-closure glaucoma with an intraocular pressure (IOP) of 65 mmHg. After unsuccessful attempts with medical treatment and two laser peripheral iridotomies, iridoplasty allowed to break posterior synechiae, open the angle, and reduce the IOP within a few hours. CONCLUSIONS: Argon laser iridoplasty allowed rapid reduction of IOP and prevented the need for emergency surgery. Therefore, the authors stipulate that it is a viable management option in active uveitic acute angle-closure glaucoma.
Resumo:
PURPOSE: The objective of this study was to evaluate the long-term safety and pharmacokinetic profile of a dexamethasone-loaded poly-epsilon-caprolactone (PCL) intravitreous implant. METHODS: The PCL devices were prepared by compression and were inserted into the vitreous of pigmented rabbits. At different time points, vitreous samples were retrieved, and dexamethasone concentration was analyzed by high-performance liquid chromatography. The biodegradation of the implants was evaluated by scanning electron microscopy, and the dexamethasone remaining was evaluated at the end of follow-up. Clinical and histologic examinations were performed to evaluate the implant's tolerance. RESULTS: The PCL implant allows for a controlled and prolonged delivery of dexamethasone in rabbits eyes since it released the drug within the therapeutic range for at least 55 weeks. At 55 weeks approximately 79% of the drug was still present in the implant. Biodegradation study showed that PCL implants degradation is very slow. Clinical and histologic observations showed that the devices were very well tolerated in the rabbit eye. CONCLUSIONS: This study demonstrates the feasibility and tolerance of intravitreous PCL drug delivery systems, which can offer a wide range of applications for intraocular drug delivery because of their controlled and prolonged release over months or even years.
Resumo:
PURPOSE: To evaluate subconjunctival mitomycin C (MMC) injection efficacy and safety in patients with failing glaucoma non-penetrating filtering blebs. METHODS: Twenty-eight eyes were consecutively recruited for this study. Only one eye for each patient was randomly selected. All the recruited patients had glaucoma and uncontrolled intraocular pressure after a non-penetrating filtering glaucoma surgery and/or a pathological aspect of the filtering bleb (i.e., vascularized and/or encysted). One or more MMC injections were performed under the conjunctiva closed to the bleb to improve filtration. Local effects and complications of subconjunctival MMC injections were analyzed. RESULTS: Out of the 28 patients, 21 (75%) had MMC also applied intraoperatively. The mean postoperative IOP before MMC injections was 17 +/- 6.6 mmHg. The final IOP after MMC injections was 13.9 +/- 2.9 mmHg after a mean follow-up of 6 months. A total of 67 subconjunctival MMC injections were performed with a mean of 2.9 (ranging from 1 to 5) injections per patient. The only complication found to be possibly related to MMC injections was two cases of corneal Dellen. CONCLUSION: From these preliminary results, subconjunctival MMC injections in selected cases appear to be not only safe but also effective in promoting further the postoperative IOP drop.
Resumo:
Résumé : Ce travail porte sur l'étude rétrospective d'une série de jeunes patients opérés de glaucomes pédiatriques. Le but est d'évaluer le résultat au long cours d'une intervention chirurgicale combinant une sclérectomie profonde et une trabéculectomie (sclérectomie profonde pénétrante). Durant la période de mars 1997 à octobre 2006, 28 patients on été suivis pour évaluer le résultat de cette chirurgie effectuées sur 35 yeux. Un examen ophtalmologique complet a été pratiqué avant la chirurgie, 1 et 7 jours, puis 1, 2, 3, 4, 6, 9, 12 mois, enfin tous les 6 mois après l'opération. Les critères d'évaluation du résultat postopératoire sont : les changements de pression intraoculaire, le traitement antiglaucomateux adjuvant, le taux de complication, le nombre de reprises chirurgicales,- l'erreur de réfraction, la meilleure acuité visuelle corrigée, l'état et le diamètre de la cornée. L'âge moyen est de 3.6 ± 4.5 ans et le suivi moyen de 3.6 ± 2.9 ans. La pression intraoculaire préopératoire de 31.9 ± 11.5 mmHg baisse de 58.3% (p<0.005) à la fin du suivi. Sur les 14 patients dont l'acuité visuelle a pu être mesurée, 8 (57.1 %) ont une acuité égale ou supérieure à 5/10e, 3 (21.4%) une acuité de 2/10e après intervention. Le taux de succès cumulatif complet à 9 ans est de 52.3%, le succès relatif 70.6%. Les complications menaçant la vision (8.6%) ont été plus fréquentes dans les cas de glaucome réfractaire. Pour conclure la sclérectomie profonde combinée à une trabéculectomie est une technique chirurgicale développée afin de contrôler la pression intraoculaire dans les cas de glaucomes congénitaux, juvéniles et secondaires. Les résultats intermédiaires sont encourageants et prometteurs. Les cas préalablement opérés avant cette nouvelle technique ont cependant un pronostic moins favorable. Le nombre de complications menaçant la vision est essentiellement lié à la sévérité du glaucome et au nombre d'interventions préalables. Abstract : Purpose : To evaluate the outcomes of combined deep sclerectomy and trabeculectomy (penetrating deep sclerectomy) in pediatric glaucoma. Design : Retrospective, non-consecutive, non-comparative, interventional case series. Participants : Children suffering from pediatric glaucoma who underwent surgery between March 1997 and October 2006 were included in this study. Methods : A primary combined deep sclerectomy and trabeculectomy was performed in 35 eyes of 28 patients. Complete examinations were performed before surgery, postoperatively at 1 and 7 days, at 1, 2, 3, 4, 6, 9, 12 months and then every 6 months after surgery. Main Outcome Measures : Surgical outcome was assessed in terms of intraocular pressure (IOP) change, additional glaucoma medication, complication rate, need for surgical revision, as well as refractive errors, best corrected visual acuity (BCVA), and corneal clarity and diameters. Results : The mean age before surgery was 3.6 ± 4.5 years, and the mean follow-up was 3.5 ± 2.9 years. The mean preoperative IOP was 31.9 ± 11.5 mmHg. At the end of follow-up, the mean IOP decreased by 58.3% (p<0.005), and from 14 patients with available BCVA 8 patients (57.1 %) achieved. 0.5 (20/40) or better, 3 (21.4%) 0.2 (20/100), and 2 (14.3%) 0.1 (20/200) in their better eye. The mean refractive error (spherical equivalent) at final follow-up visits was +0.83 ± 5.4. Six patients (43%) were affected by myopia. The complete and qualified success rates, based on a cumulative survival curve, after- 9 years were 52.3% and 70.6%, respectively (p<0.05). Sight threatening complications were more common (8.6%) in refractory glaucomas. Conclusions : Combined deep sclerectomy and trabeculectomy is a surgical technique developed to control IOP in congenital, secondary and juvenile glaucomas. The intermediate results are satisfactory and promising. Previous classic glaucoma surgeries performed before this new technique had less favourable results. The number of sight threatening complications is related to the severity of glaucoma and number of previous surgeries.
Resumo:
PURPOSE: Apoptosis is known to play a key role in cell death after retinal ischemia. However, little is known about the kinetics of the signaling pathways involved and their contribution to this process. The aim of this study was to determine whether changes in the expression of molecules in the mitochondrial apoptotic pathway might explain the progression of retinal damage following ischemia/reperfusion. METHODS: Retinal ischemia was induced by elevating intraocular pressure in the vitreous cavity to 150 mmHg for a period of 60 min. At time 0, 3 h (early phase), and 24 h (late phase) after reperfusion, the retinas were harvested and modifications in the expression of Bax, Bak, Bcl-2, and Bcl-x(L) as well as caspase-3 and -7, were examined by qPCR and, in some cases, by western blot. RESULTS: qPCR analysis performed at the early phase after ischemia revealed a time dependent decrease in Bax, Bak, and Bcl-x(L) and no alteration in Bcl-2 mRNA expression in response to retinal ischemia. At the protein level, proapoptotic Bax and Bak were not modulated while Bcl-2 and Bcl-x(L) were significantly upregulated. At this stage, the Bax per Bcl-2 and Bax:Bcl-x(L) ratios were not modified. At the late phase of recovery, Bax and Bcl-x(L) mRNAs were downregulated while Bak was increased. Increased Bax:Bcl-2 and Bax:Bcl-x(L) ratios at both the mRNA and protein levels were observed 24 h after the ischemic insult. Analysis of caspases associated with mitochondria-mediated apoptosis revealed a specific increase in the expression of caspase-3 in the ischemic retinas 24 h after reperfusion, and a decrease in the expression of caspase-7. CONCLUSIONS: This study revealed that Bcl-2-related family members were differently regulated in the early and late phases after an ischemic insult. We showed that the Bax:Bcl-2 and Bax:Bcl-x(L) balances were not affected in the initial phases, but the Bax:Bcl-x(L) ratio shifted toward apoptosis during the late phase of recovery. This shift was reinforced by caspase-3 upregulation.
Resumo:
AIM: To prospectively study the intraocular pressure (IOP) lowering effect and safety of the new method of very deep sclerectomy with collagen implant (VDSCI) compared with standard deep sclerectomy with collagen implant (DSCI). METHODS: The trial involved 50 eyes of 48 patients with medically uncontrolled primary and secondary open-angle glaucoma, randomized to undergo either VDSCI procedure (25 eyes) or DSCI procedure (25 eyes). Follow-up examinations were performed before surgery and after surgery at day 1, at week 1, at months 1, 2, 3, 6, 9, 12, 18, and 24 months. Ultrasound biomicroscopy was performed at 3 and 12 months. RESULTS: Mean follow-up period was 18.6+/-5.9 (VDSCI) and 18.9+/-3.6 (DSCI) months (P=NS). Mean preoperative IOP was 22.4+/-7.4 mm Hg for VDSCI and 20.4+/-4.4 mm Hg for DSCI eyes (P=NS). Mean postoperative IOP was 3.9+/-2.3 (VDSCI) and 6.3+/-4.3 (DSCI) (P<0.05) at day 1, and 12.2+/-3.9 (VDSCI) and 13.3+/-3.4 (DSCI) (P=NS) at month 24. At the last visit, the complete success rate (defined as an IOP of < or =18 mm Hg and a percentage drop of at least 20%, achieved without medication) was 57% in VDSCI and 62% in DSCI eyes (P=NS) ultrasound biomicroscopy at 12 months showed a mean volume of the subconjunctival filtering bleb of 3.9+/-4.2 mm3 (VDSCI) and 6.8+/-7.5 mm3 (DSCI) (P=0.426) and 5.2+/-3.6 mm3 (VDSCI) and 5.4+/-2.9 mm3 (DSCI) (P=0.902) for the intrascleral space. CONCLUSIONS: Very deep sclerectomy seems to provide stable and good control of IOP at 2 years of follow-up with few postoperative complications similar to standard deep sclerectomy with the collagen implant.
Resumo:
AbstractPurpose: to evaluate the tolerability, comfort and precision of the signal transmission of an ocular Sensor used for 24-hour intraocular pressure fluctuation monitoring in humans.Patients and methods: In this uncontrolled open trial involving 10 healthy volunteers an 8.7 mm radius prototype ocular telemetry Sensor (SENSIMED Triggerfish®, Lausanne, Switzerland) and an orbital bandage containing a loop antenna were applied and connected to a portable recorder after full eye examination. Best corrected visual acuity and position, surface wetting ability and mobility of the Sensor were assessed after 5 and 30 minutes, 4, 12 and 24 hours. Subjective wearing comfort was scored and activities documented in a logbook. After Sensor removal a full eye examination was repeated and the recorded signal analyzed.Results: The comfort score was high and did not fluctuate significantly over time. The mobility of the Sensor was limited across follow-up visits and its surface wetting ability remained good. Best corrected visual acuity was significantly reduced during Sensor wear and immediately after its removal (from 1.07 before, to 0.85 after, P-value 0.008). Three subjects developed a mild, transient corneal abrasion. In all but one participant we obtained usable data of a telemetric signal recording with sufficient sensitivity to depict ocular pulsation.Conclusions: This 24-hour- trial has encouraging results on the tolerability and functionality of the ocular telemetric Sensor for intraocular pressure fluctuation monitoring. Further studies with different Sensor radii conducted on a larger study population are needed to improve comfort, precision and interpretation of the telemetric signal.
Resumo:
PURPOSE: To assess the usefulness of electron microscopy of the aqueous cells when confronted with the clinical association of rhegmatogenous retinal detachment after trauma, high intraocular pressure (IOP) and aqueous cells. METHOD: We report a clinical history of a 50-years-old man who had ocular trauma with perforation in 1944, intraocular lens for traumatic cataract in 1988, Yag capsulotomy in 1993 and retinal detachment with oral dialysis, high IOP and aqueous cells in anterior chamber in 1995. During the surgical therapy we performed an anterior chamber puncture to analyse the aqueous cells. An electron microscopic study was performed on 0.2 ml of aqueous humor mixed in the same volume of 2.5% glutaraldehyde and fixed with 1% osmium acid. RESULTS: Electron microscopic ultrastructural study of the aqueous cells showed numerous photoreceptor outer segments, some of them appearing degenerated. CONCLUSION: The combination of rhegmatogenous retinal detachment with tears near the ora serrata, high IOP and aqueous cells in the anterior chamber should lead the physician to do an anterior chamber puncture and analyse the aqueous cells structure. The combination of those three clinical signs associated with the photoreceptor outer segments in the anterior chamber allowed to diagnose the Schwartz-Matsuo syndrome.
Resumo:
Purpose: To compare the disease classification using optic nerve head imaging against clinical examination combined with perimetry in the case-finding environment.Methods: During a glaucoma screening event at the University Hospital in Lausanne 148 attendees opted to undergo an extended screening exam consisting of perimetry with Octopus (Haag-Streit, Koeniz, Switzerland), tonometry, gonioscopy, slit-lamp optic nerve head examination and Heidelberg Retinal Tomorgraph (HRT, Heidelberg engineering). Classification criteria of an abnormal clinical exam consisted of a cup to disc ratio > 0.6, other disc abnormality (e.g. notching), closed angles, Van Herrick < ¼ and intraocular pressure >21mmHg. In perimetry a square root loss variance (sLV) >3.0 dB was considered abnormal. Those cases with both an abnormal clinical exam and abnormal perimetric results were considered to be glaucoma suspects. An abnormal HRT exam was a global Moorfields Regression Analysis (MRA) result of "outside normal limits". The results from the worse eye for each instrument are reported.Results: The mean age of the patients was 59.9 years (SD ±14.8years). 46 subjects failed the clinical exam. 55 subjects had sLV>3.0dB. 86 subjects failed one or more of the testing components, 21 subjects failed both the clinical exam and perimetry. Two cases of advanced glaucoma were diagnosed on the day of the event. 20 subjects were referred due to other ocular pathology (10 cataract; 2 AMD; 8 other). 16 subjects were outside normal limits with the HRT, of which 11 failed the clinical exam, 9 failed the perimetric exam and 7 failed all three. HRT had a sensitivity of 33% CI [15%,57%] with a specificity of 93% CI [87%,97%].Conclusions: HRT shows good specificity, however the low sensitivity makes it of limited use in the proposed case finding scenario.
Resumo:
INTRODUCTION: The association of a granulomatous uveitis and congenital cataract and is rarely observed in newborn children. We describe the history of two patients presenting simultaneously with these two features in the absence of a TORCH infection. PATIENTS AND METHODS: The first patient, a boy born in 1997, presented to our hospital two days after birth with multiples Koeppe's and Busacca's nodules and bilateral cataract. The second patient, a boy born in 2006, was referred two weeks after birth. He presented with a severe unilateral granulomatous uveitis, multiples iris nodules, a high intraocular pressure of 45 mmHg and a congenital cataract. THERAPY AND OUTCOME: Lens extraction produced a rapid resolution of uveitis in these two patients. TORCH infection was ruled out in both children by history, extensive serologies performed simultaneously in mother and child or PCR of ocular fluids. CONCLUSIONS: A congenital cataract associated with a granulomatous uveitis is an extremely rare association. The removal of the lens resulted in complete resolution of the inflammation: a phacogenic mechanism could be at the origin of ocular inflammation in both cases.
Resumo:
Purpose: To evaluate the safety and efficacy of "safe" trabeculectomy (ST) versus "safe" phacotrabeculectomy (SPT).Methods: This study included 72 eyes with medically uncontrolled chronic glaucoma who underwent fornix based trabeculectomy with adjustable/releasable sutures and intraoperative mitomycin C ± phacoemulsification. 36 eyes underwent SPT and 36 eyes had ST. There was no difference between groups for age, intraocular pressure (IOP), diagnosis and gender. Subconjunctival antimetabolite injections and bleb needlings were administered according to bleb vascularity and IOP trends. Main outcome measures were: success rate (definition: IOP≤21mmHg and 20% IOP reduction); number of antimetabolite injections; bleb needlings; glaucoma medications and complications.Results: Mean age (SPT vs ST) was 72.7±12.1 years vs 72.3±12.9 years; p=0.44. Mean preoperative IOP was 24.5±8.8 mmHg vs 24.3±8.2 mmHg; p=0.46. Postoperative IOP was 13.1±4.5mmHg vs 12.4±3.2; p=0.24. Ninety percent of both groups required at least one suture removal. There was no statistically significant difference in success rate between groups, 80% vs 83%; number of eyes requiring antimetabolite injections was 22 eyes (mean 3.2 per eye) vs 23 eyes (mean 2.6 per eye, p=0.24); bleb needlings was performed in 16 eyes (mean 2.5 per eye) vs in 11 eyes (mean 2.0 per eye, p=0.15). The number of eyes restarting glaucoma medications was 5 vs 4. Minor complications were infrequent in both groups, 9 vs 10 eyes.Conclusions: The success and complications rates were similar between groups. The number of postoperative interventions required was slightly greater in the SPT group (not statistically significant). SPT is a safe procedure for patients with coexistent glaucoma and cataract and produces similar IOP-lowering to safe trabeculectomy.
Resumo:
Purpose: to describe a case in which the diagnosis of Morganian cataract required clinical and instrumental differentiation from iris pathologies, including iris melanoma. Methods: a 60-years-old Caucasian man referred to our institute for worsening of vision in last few months. Clinical evaluation consisted in complete ophthalmological assessment, ultrasound examination (biomicroscopy and 20MHz), and Magnetic Resonance Imaging (MRI) completed with Susceptibility Weighted Imaging (SWI). Results: traumatic corneal wound of the left eye (LE) had occurred 5 years before, and was treated with medical therapy alone. Best-corrected visual acuity (BCVA) was 3/10 in the right eye (RE) and finger count in the LE, with intraocular pressure at 13 and 20mmHg, respectively. Chronic central serous chorioretinopathy, accounted for the low visual acuity of the RE. Slit-lamp biomicroscopy of the LE was as in Figure 1; LE fundus was not clinically observable. Despite MRI was compatible with an iris solid formation, characterized by contrast enhancement and hyperintense signal in SWI, ultrasound indicated rather a mixed solid and liquid content (moderately echogenic external layer, hyporeflective internal content). Iris root and ciliary body were not significantly altered; the lens showed inhomogeneous content. We considered Morgagnian cataract the most probable diagnosis. Surgery confirmed the presence of a hypermature cataract with prior anterior capsule fissuring; the liquefied cortex infiltrated the iris without anterior chamber seeping. Post-operative BCVA was 3/10 and fundus examination disclosed an advanced macular chronic central serous chorioretinopathy. Conclusions: In the reported case a previous perforating trauma have probably damaged the lens capsule and started cataract progression. Curiously cataract developed percolating into the iris stroma, thus simulating an iris mass. At our knowledge, Morgagnian cataract has never been included in the differential diagnosis of iris mass.
Resumo:
STUDY OBJECTIVES: Besides their well-established role in circadian rhythms, our findings that the forebrain expression of the clock-genes Per2 and Dbp increases and decreases, respectively, in relation to time spent awake suggest they also play a role in the homeostatic aspect of sleep regulation. Here, we determined whether time of day modulates the effects of elevated sleep pressure on clock-gene expression. Time of day effects were assessed also for recognized electrophysiological (EEG delta power) and molecular (Homer1a) markers of sleep homeostasis. DESIGN: EEG and qPCR data were obtained for baseline and recovery from 6-h sleep deprivation starting at ZT0, -6, -12, or -18. SETTING: Mouse sleep laboratory. PARTICIPANTS: Male mice. INTERVENTIONS: Sleep deprivation. RESULTS: The sleep-deprivation induced changes in Per2 and Dbp expression importantly varied with time of day, such that Per2 could even decrease during sleep deprivations occurring at the decreasing phase in baseline. Dbp showed similar, albeit opposite dynamics. These unexpected results could be reliably predicted assuming that these transcripts behave according to a driven damped harmonic oscillator. As expected, the sleep-wake distribution accounted for a large degree of the changes in EEG delta power and Homer1a. Nevertheless, the sleep deprivation-induced increase in delta power varied also with time of day with higher than expected levels when recovery sleep started at dark onset. CONCLUSIONS: Per2 and delta power are widely used as exclusive state variables of the circadian and homeostatic process, respectively. Our findings demonstrate a considerable cross-talk between these two processes. As Per2 in the brain responds to both sleep loss and time of day, this molecule is well positioned to keep track of and to anticipate homeostatic sleep need. CITATION: Curie T; Mongrain V; Dorsaz S; Mang GM; Emmenegger Y; Franken P. Homeostatic and circadian contribution to EEG and molecular state variables of sleep regulation. SLEEP 2013;36(3):311-323.
Resumo:
PURPOSE: To evaluate the outcomes of combined deep sclerectomy and trabeculectomy (penetrating deep sclerectomy) in pediatric glaucoma. DESIGN: Retrospective, nonconsecutive, noncomparative, interventional case series. PARTICIPANTS: Children suffering from pediatric glaucoma who underwent surgery between March 1997 and October 2006 were included in this study. METHODS: A primary combined deep sclerectomy and trabeculectomy was performed in 35 eyes of 28 patients. Complete examinations were performed before surgery, postoperatively at 1 and 7 days, at 1, 2, 3, 4, 6, 9, and 12 months, and then every 6 months after surgery. MAIN OUTCOME MEASURES: Surgical outcome was assessed in terms of intraocular pressure (IOP) change, additional glaucoma medication, complication rate, need for surgical revision, as well as refractive errors, best-corrected visual acuity (BCVA), and corneal clarity and diameters. RESULTS: The mean age before surgery was 3.6+/-4.5 years, and the mean follow-up was 3.5+/-2.9 years. The mean preoperative IOP was 31.9+/-11.5 mmHg. At the end of follow-up, the mean IOP decreased by 58.3% (P<0.005), and from 14 patients with available BCVA 8 patients (57.1%) achieved 0.5 (20/40) or better, 3 (21.4%) 0.2 (20/100), and 2 (14.3%) 0.1 (20/200) in their better eye. The mean refractive error (spherical equivalent [SE]) at final follow-up visits was +0.83+/-5.4. Six patients (43%) were affected by myopia. The complete and qualified success rates, based on a cumulative survival curve, after 9 years were 52.3% and 70.6%, respectively (P<0.05). Sight-threatening complications were more common (8.6%) in refractory glaucomas. CONCLUSIONS: Combined deep sclerectomy and trabeculectomy is an operative technique developed to control IOP in congenital, secondary, and juvenile glaucomas. The intermediate results are satisfactory and promising. Previous classic glaucoma surgeries performed before this new technique had less favorable results. The number of sight-threatening complications is related to the severity of glaucoma and number of previous surgeries. FINANCIAL DISCLOSURE(S): The authors have no proprietary or commercial interest in any materials discussed in this article.
Resumo:
AIM: The use of an animal model to study the aqueous dynamic and the histological findings after deep sclerectomy with (DSCI) and without collagen implant. METHODS: Deep sclerectomy was performed on rabbits' eyes. Eyes were randomly assigned to receive collagen implants. Measurements of intraocular pressure (IOP) and aqueous outflow facility using the constant pressure method through cannulation of the anterior chamber were performed. The system was filled with BSS and cationised ferritin. Histological assessment of the operative site was performed. Sections were stained with haematoxylin and eosin and with Prussian blue. Aqueous drainage vessels were identified by the reaction between ferritin and Prussian blue. All eyes were coded so that the investigator was blind to the type of surgery until the evaluation was completed. RESULTS: A significant decrease in IOP (p<0.05) was observed during the first 6 weeks after DSCI (mean IOP was 13.07 (2.95) mm Hg preoperatively and 9.08 (2.25) mm Hg at 6 weeks); DS without collagen implant revealed a significant decrease in IOP at weeks 4 and 8 after surgery (mean IOP 12.57 (3.52) mm Hg preoperatively, 9.45 (3.38) mm Hg at 4 weeks, and 9.22 (3.39) mm Hg at 8 weeks). Outflow facility was significantly increased throughout the 9 months of follow up in both DSCI and DS groups (p<0.05). The preoperative outflow facility (OF) was 0.15 (0.02) micro l/min/mm Hg. At 9 months, OF was 0.52 (0.28) microl/min/mm Hg and 0.46 (0.07) micro l/min/mm Hg for DSCI and DS respectively. Light microscopy studies showed the appearance of new aqueous drainage vessels in the sclera adjacent to the dissection site in DSCI and DS and the apparition of spindle cells lining the collagen implant in DSCI after 2 months. CONCLUSION: A significant IOP decrease was observed during the first weeks after DSCI and DS. DS with or without collagen implant provided a significant increase in outflow facility throughout the 9 months of follow up. This might be partly explained by new drainage vessels in the sclera surrounding the operated site. Microscopic studies revealed the appearance of spindle cells lining the collagen implant in DSCI after 2 months.