1000 resultados para Durable medical equipment


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The aim of this study was to evaluate the performances of observers in diagnosing proximal caries in digital images obtained from digital bitewing radiographs using two scanners and four digital cameras in Joint Photographic Experts Group (JPEG) and tagged image file format (TIFF) files, and comparing them with the original conventional radiographs. Method: In total, 56 extracted teeth were radiographed with Kodak Insight film (Eastman Kodak, Rochester, NY) in a Kaycor Yoshida X-ray device (Kaycor X-707;Yoshida Dental Manufacturing Co., Tokyo, Japan) operating at 70 kV and 7 mA with an exposure time of 0.40 s. The radiographs were obtained and scanned by CanonScan D646U (Canon USA Inc., Newport News, VA) and Genius ColorPage HR7X (KYE Systems Corp. America, Doral, FL) scanners, and by Canon Powershot G2 (Canon USA Inc.), Canon RebelXT (Canon USA Inc.), Nikon Coolpix 8700 (Nikon Inc., Melville, NY), and Nikon D70s (Nikon Inc.) digital cameras in JPEG and TIFF formats. Three observers evaluated the images. The teeth were then observed under the microscope in polarized light for the verification of the presence and depth of the carious lesions. Results: The probability of no diagnosis ranged from 1.34% (Insight film) to 52.83% (CanonScan/JPEG). The sensitivity ranged from 0.24 (Canon RebelXT/JPEG) to 0.53 (Insight film), the specificity ranged from 0.93 (Nikon Coolpix/JPEG, Canon Powershot/TIFF, Canon RebelXT/JPEG and TIFF) to 0.97 (CanonScan/TIFF and JPEG) and the accuracy ranged from 0.82 (Canon RebelXT/JPEG) to 0.91 (CanonScan/JPEG). Conclusion: The carious lesion diagnosis did not change in either of the file formats (JPEG and TIFF) in which the images were saved for any of the equipment used. Only the CanonScan scanner did not have adequate performance in radiography digitalization for caries diagnosis and it is not recommended for this purpose. Dentomaxillofacial Radiology (2011) 40, 338-343. doi: 10.1259/dmfr/67185962

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Recently developed portable dental X-ray units increase the mobility of the forensic odontologists and allow more efficient X-ray work in a disaster field, especially when used in combination with digital sensors. This type of machines might also have potential for application in remote areas, military and humanitarian missions, dental care of patients with mobility limitation, as well as imaging in operating rooms. Objective: To evaluate radiographic image quality acquired by three portable X-ray devices in combination with four image receptors and to evaluate their medical physics parameters. Materials and methods: Images of five samples consisting of four teeth and one formalin-fixed mandible were acquired by one conventional wall-mounted X-ray unit, MinRay (R) 60/70 kVp, used as a clinical standard, and three portable dental X-ray devices: AnyRay (R) 60 kVp, Nomad (R) 60 kVp and Rextar (R) 70 kVp, in combination with a phosphor image plate (PSP), a CCD, or a CMOS sensor. Three observers evaluated images for standard image quality besides forensic diagnostic quality on a 4-point rating scale. Furthermore, all machines underwent tests for occupational as well as patient dosimetry. Results: Statistical analysis showed good quality imaging for all system, with the combination of Nomad (R) and PSP yielding the best score. A significant difference in image quality between the combination of the four X-ray devices and four sensors was established (p < 0.05). For patient safety, the exposure rate was determined and exit dose rates for MinRay (R) at 60 kVp, MinRay (R) at 70 kVp, AnyRay (R), Nomad (R) and Rextar (R) were 3.4 mGy/s, 4.5 mGy/s, 13.5 mGy/s, 3.8 mGy/s and 2.6 mGy/s respectively. The kVp of the AnyRay (R) system was the most stable, with a ripple of 3.7%. Short-term variations in the tube output of all the devices were less than 10%. AnyRay (R) presented higher estimated effective dose than other machines. Occupational dosimetry showed doses at the operator`s hand being lowest with protective shielding (Nomad (R): 0.1 mu Gy). It was also low while using remote control (distance > 1 m: Rextar (R) < 0.2 mu Gy, MinRay (R) < 0.1 mu Gy). Conclusions: The present study demonstrated the feasibility of three portable X-ray systems to be used for specific indications, based on acceptable image quality and sufficient accuracy of the machines and following the standard guidelines for radiation hygiene. (C) 2010 Elsevier Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The near completion of the Human Genome Project stands as a remarkable achievement, with enormous implications for both science and society. For scientists, it is the first step in a complex process that will lead to important advances in the diagnosis and treatment of many diseases. Society, meanwhile, must prevent genetic discrimination, and protect genetic privacy through appropriate legislation.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. To determine out-of-pocket expenditures related to osteoarthritis (OA) and to explore whether demographic details, health status scores (Medical Outcomes Study 36-item Short Form [SF-36] and Western Ontario and McMaster Universities Osteoarthritis Index [WOMAC]), or perception of social effect were expenditure determinants. Methods. A prospective cohort study of community-dwelling subjects with OA completed 4 consecutive 3-month cost diaries. In addition, subjects completed the SF-36 and WOMAC at baseline and at 12 months. Social impact at baseline was collected. Four groups categorized by age and sex were compared. Patients undergoing joint replacement were excluded. Results. Differences in health status were defined more by age than by sex, especially for physical function. The costs to the patients were high, particularly for women, who spent more on medications and special equipment. Women also reported receiving more assistance from family and friends. Higher disease-related expenditures were associated with greater pain levels, poorer social function and mental health, and longer duration of disease. Significant independent predictors of total patient expenditures related to OA were being female and having joint stiffness. Conclusion. Despite having heavily subsidized health care and access to the Pharmaceutical Benefits Scheme, out-of-pocket costs for patients with OA in Australia are considerable. Higher expenditures for patients with OA are related to more advanced disease, especially for women.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A randomized controlled trial was carried out to measure the cost-effectiveness of realtime teledermatology compared with conventional outpatient dermatology care for patients from urban and rural areas. One urban and one rural health centre were linked to a regional hospital in Northern Ireland by ISDN at 128 kbit/s. Over two years, 274 patients required a hospital outpatient dermatology referral -126 patients (46%) were randomized to a telemedicine consultation and 148 (54%) to a conventional hospital outpatient consultation. Of those seen by telemedicine, 61% were registered with an urban practice, compared with 71% of those seen conventionally. The clinical outcomes of the two types of consultation were similar - almost half the patients were managed after a single consultation with the dermatologist. The observed marginal cost per patient of the initial realtime teledermatology consultation was f52.85 for those in urban areas and f59.93 per patient for those from rural areas. The observed marginal cost of the initial conventional consultation was f47.13 for urban patients and f48.77 for rural patients. The total observed costs of teledermatology were higher than the costs of conventional care in both urban and rural areas, mainly because of the fixed equipment costs. Sensitivity analysis using a real-world scenario showed that in urban areas the average costs of the telemedicine and conventional consultations were about equal, while in rural areas the average cost of the telemedicine consultation was less than that of the conventional consultation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective-To test the hypothesis that telemedicine for new patient referrals to neurological outpatients is as efficient and acceptable as conventional face to face consultation. Methods-A randomised controlled trial between two groups: face to face (FF) and telemedicine (TM). This study was carried out between a neurological centre and outlying clinics at two distant hospitals linked by identical medium cost commercial interactive video conferencing equipment with ISDN lines transmitting information at 384 kbits/s. The same two neurologists carried out both arms of the study. Of the 168 patients who were suitable for the study, 86 were randomised into the telemedicine group and 82 into the face to face group. Outcome measures were (I) consultation process: (a) number of investigations; (b) number of drugs prescribed; (c) number of patient reviews and (2) patient satisfaction: (a) confidence in consultation; (b) technical aspects of consultation; (c) aspects surrounding confidentiality. Diagnostic categories were also measured to check equivalence between the groups: these were structural neurological, structural non-neurological, nonstructural, and uncertain. Results-Diagnostic categories were similar (p>0.5) between the two groups. Patients in the telemedicine group had significantly more investigations (p=0.001). There was no difference in the number of drugs prescribed (p>0.5). Patients were generally satisfied with both types of consultation process except for concerns about confidentiality and embarrassment in the telemedicine group (p=0.017 and p=0.005 respectively). Conclusion-Telemedicine for new neurological outpatients is possible and feasible but generates more investigations and is less well accepted than face to face examination.