909 resultados para Dual Inverter


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BRAF inhibitory therapy is the mainstream treatment for BRAF mutant advanced melanoma. However vemurafenib, a type I mutant BRAF V600 inhibitor, induces an array of proliferative skin disorders from keratosis pilaris-like and keratoacanthoma-like lesions to locally aggressive cutaneous squamous cell carcinoma (cuSCC). Dual BRAF/MEK inhibition is known to lower the incidence of such manifestations, but it is not known whether it can counteract established lesions. Here we show, for the first time, a dramatic response and a restitution ad integro upon dual inhibition of a widespread proliferative affection induced by BRAF monotherapy. A 75-year-old woman was diagnosed with a BRAF V600E mutated metastatic melanoma. Following dacarbazine (DTIC) and ipilimumab, the patient was started on 960 mg twice daily vemurafenib (Zelboraf), which resulted in complete response, but the patient also developed grade IV skin toxicity. Despite dose-reduction to 720 mg twice daily the side effects persisted. We hypothesized that a switch to double inhibition of the mitogen-activated protein kinase pathway with dabrafenib and trametinib could lead to improvement of the skin lesions, while preserving tumor control. The patient was closely followed for changes in skin lesions. We witnessed a rapid regression followed by complete disappearance of all side effects of vemurafenib except for grade I fatigue. The biopsied skin lesions show regression of established keratoacanthoma-like lesions with signs of apoptosis. Switching from the current standard of care vemurafenib therapy to the double BRAF/MEK inhibition in BRAF mutant melanoma patients results in rapid disappearance of established proliferative skin disorders.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this article, the author provides a framework to guide¦research in emotional intelligence. Studies conducted up¦to the present bear on a conception of emotional intelligence¦as pertaining to the domain of consciousness and¦investigate the construct with a correlational approach.¦As an alternative, the author explores processes underlying¦emotional intelligence, introducing the distinction¦between conscious and automatic processing as a potential¦source of variability in emotionally intelligent¦behavior. Empirical literature is reviewed to support the¦central hypothesis that individual differences in emotional¦intelligence may be best understood by considering¦the way individuals automatically process emotional¦stimuli. Providing directions for research, the author¦encourages the integration of experimental investigation¦of processes underlying emotional intelligence with¦correlational analysis of individual differences and¦fosters the exploration of the automaticity component¦of emotional intelligence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE This prospective multicenter phase III study compared the efficacy and safety of a triple combination (bortezomib-thalidomide-dexamethasone [VTD]) versus a dual combination (thalidomide-dexamethasone [TD]) in patients with multiple myeloma (MM) progressing or relapsing after autologous stem-cell transplantation (ASCT). PATIENTS AND METHODS Overall, 269 patients were randomly assigned to receive bortezomib (1.3 mg/m(2) intravenous bolus) or no bortezomib for 1 year, in combination with thalidomide (200 mg per day orally) and dexamethasone (40 mg orally once a day on 4 days once every 3 weeks). Bortezomib was administered on days 1, 4, 8, and 11 with a 10-day rest period (day 12 to day 21) for eight cycles (6 months), and then on days 1, 8, 15, and 22 with a 20-day rest period (day 23 to day 42) for four cycles (6 months). Results Median time to progression (primary end point) was significantly longer with VTD than TD (19.5 v 13.8 months; hazard ratio, 0.59; 95% CI, 0.44 to 0.80; P = .001), the complete response plus near-complete response rate was higher (45% v 25%; P = .001), and the median duration of response was longer (17.2 v 13.4 months; P = .03). The 24-month survival rate was in favor of VTD (71% v 65%; P = .093). Grade 3 peripheral neuropathy was more frequent with VTD (29% v 12%; P = .001) as were the rates of grades 3 and 4 infection and thrombocytopenia. CONCLUSION VTD was more effective than TD in the treatment of patients with MM with progressive or relapsing disease post-ASCT but was associated with a higher incidence of grade 3 neurotoxicity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During the latest few years the need for new motor types has grown, since both high efficiency and an accurate dynamic performance are demanded in industrial applications. For this reason, new effective control systems such as direct torque control (DTC) have been developed. Permanent magnet synchronous motors (PMSM) are well suitable for new adjustable speed AC inverter drives, because their efficiency and power factor are not depending on the pole pair number and speed to the same extent as it is the case in induction motors. Therefore, an induction motor (IM) with a mechanical gearbox can often be replaced with a direct PM motor drive. Space as well as costs will be saved, because the efficiency increases and the cost of maintenance decreases as well. This thesis deals with design criterion, analytical calculation and analysis of the permanent magnet synchronous motor for both sinusoidal air-gap flux density and rectangular air-gapflux density. It is examined how the air-gap flux, flux densities, inductances and torque can be estimated analytically for salient pole and non-salient pole motors. It has been sought by means of analytical calculations for the ultimate construction for machines rotating at relative low 300 rpm to 600 rpm speeds, which are suitable speeds e.g. in Pulp&Paper industry. The calculations are verified by using Finite Element calculations and by measuring of prototype motor. The prototype motor is a 45 kW, 600 rpm PMSM with buried V-magnets, which is a very appropriate construction for high torque motors with a high performance. With the purposebuilt prototype machine it is possible not only to verify the analytical calculations but also to show whether the 600 rpm PMSM can replace the 1500 rpm IM with a gear. It can also be tested if the outer dimensions of the PMSM may be the same as for the IM and if the PMSM in this case can produce a 2.5 fold torque, in consequence of which it may be possible to achieve the same power. The thesis also considers the question how to design a permanent magnet synchronous motor for relatively low speed applications that require a high motor torqueand efficiency as well as bearable costs of permanent magnet materials. It is shown how a selection of different parameters affects the motor properties. Key words: Permanent magnet synchronous motor, PMSM, surface magnets, buried magnets

Relevância:

20.00% 20.00%

Publicador:

Resumo:

IIn electric drives, frequency converters are used to generatefor the electric motor the AC voltage with variable frequency and amplitude. When considering the annual sale of drives in values of money and units sold, the use of low-performance drives appears to be in predominant. These drives have tobe very cost effective to manufacture and use, while they are also expected to fulfill the harmonic distortion standards. One of the objectives has also been to extend the lifetime of the frequency converter. In a traditional frequency converter, a relatively large electrolytic DC-link capacitor is used. Electrolytic capacitors are large, heavy and rather expensive components. In many cases, the lifetime of the electrolytic capacitor is the main factor limiting the lifetime of the frequency converter. To overcome the problem, the electrolytic capacitor is replaced with a metallized polypropylene film capacitor (MPPF). The MPPF has improved properties when compared to the electrolytic capacitor. By replacing the electrolytic capacitor with a film capacitor the energy storage of the DC-linkwill be decreased. Thus, the instantaneous power supplied to the motor correlates with the instantaneous power taken from the network. This yields a continuousDC-link current fed by the diode rectifier bridge. As a consequence, the line current harmonics clearly decrease. Because of the decreased energy storage, the DC-link voltage fluctuates. This sets additional conditions to the controllers of the frequency converter to compensate the fluctuation from the supplied motor phase voltages. In this work three-phase and single-phase frequency converters with small DC-link capacitor are analyzed. The evaluation is obtained with simulations and laboratory measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Severe acute refractory respiratory failure is considered a life-threatening situation, with a high mortality of 40 to 60%. When conservative oxygenation methods fail, a lifesaving measure is the introduction of extracorporeal membrane oxygenation (ECMO). Venovenous ECMO (VV-ECMO) is a preferred modality of support for patients with refractory acute respiratory failure. Specifically, bicaval VV-ECMO is a well-recognized and validated therapy, where single or double periphery venous access is used for the insertion of two differently sized cannulas in order to achieve adequate blood oxygenation. Compared to venoarterial ECMO, in VV-ECMO, the rate of complications, such as thrombosis, bleeding, infection and ischemic events, is lower. On the other hand, the size and insertion location is an obstacle to patient mobilization. This is a considerable problem for patients where the time interval for lung recovery and the bridge to the transplantation is prolonged. To address this issue, a dual-lumen, single venovenous cannula was introduced. Here, by insertion of one single catheter in one target vessel, in a majority of cases in the right internal jugular vein, satisfactory oxygenation of the patient is achieved. In this form, the instituted VV-ECMO enables patient mobility, better physical rehabilitation and facilitates pulmonary extubation and toilet. However, relatively early, after the first short-term reports were published, a relatively high complication rate became evident. In the recent literature, the complication rate using actual commercially available double-lumen venovenous cannula ranges between 5 and 30%. These cases were mostly conjoined to the implantation phase or the early postoperative phase and vary between right heart perforation to migration of the cannula. This review focuses on complications allied to commercially available dual-lumen, single, venovenous cannula implantation, pointing out the critical segments of the implantation process and analyzing the structure of the device.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have developed an activator/repressor expression system for budding yeast in which tetracyclines control in opposite ways the ability of tetR-based activator and repressor molecules to bind tetO promoters. This combination allows tight expression of tetO-driven genes, both in a direct (tetracycline-repressible) and reverse (tetracycline-inducible) dual system. Ssn6 and Tup1, that are components of a general repressor complex in yeast, have been tested for their repressing properties in the dual system, using lacZ and CLN2 as reporter genes. Ssn6 gives better results and allows complete switching-off of the regulated genes, although increasing the levels of the Tup1-based repressor by expressing it from a stronger promoter improves repressing efficiency of the latter. Effector-mediated shifts between expression and non-expression conditions are rapid. The dual system here described may be useful for the functional analysis of essential genes whose conditional expression can be tightly controlled by tetracyclines.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Membrane-permeable calmodulin inhibitors, such as the napthalenesulfonamide derivatives W-7/W-13, trifluoperazine, and calmidazolium, are used widely to investigate the role of calcium/calmodulin (Ca2+/CaM) in living cells. If two chemically different inhibitors (e.g. W-7 and trifluoperazine) produce similar effects, investigators often assume the effects are due to CaM inhibition. Zeta potential measurements, however, show that these amphipathic weak bases bind to phospholipid vesicles at the same concentrations as they inhibit Ca 2 /CaM; this suggests that they also bind to the inner leaflet of the plasma membrane, reducing its negative electrostatic surface potential. This change will cause electrostatically bound clusters of basic residues on peripheral (e.g. Src and K-Ras4B) and integral (e.g. epidermal growth factor receptor (EGFR)) proteins to translocate from the membrane to the cytoplasm. We measured inhibitor-mediated translocation of a simple basic peptide corresponding to the calmodulin-binding juxtamembrane region of the EGFR on model membranes; W-7/W-13 causes translocation of this peptide from membrane to solution, suggesting that caution must be exercised when interpreting the results obtained with these inhibitors in living cells. We present evidence that they exert dual effects on autophosphorylation of EGFR;W-13 inhibits epidermal growth factordependent EGFR autophosphorylation under different experimental conditions, but in the absence of epidermal growth factor, W-13 stimulates autophosphorylation of the receptor in four different cell types. Our interpretation is that the former effect is due toW-13inhibition of Ca 2 /CaM, but thelatter results could be due to binding of W-13 to the plasma membrane.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Although the studies published so far have found an affectation in the Health Related Quality of Life (HRQOL) in both psychiatric and substance use dependence disorders, very few studies have applied HRQOL as an assessment measure in patients suffering both comorbid conditions, or Dual Diagnosis. The aim of the current study was to assess HRQOL in a group of patients with Dual Diagnosis compared to two other non-comorbid groups and to determine what clinical factors are related to HRQOL. Methods: Cross-sectional assessment of three experimental groups was made through the Short Form 36 Item Health Survey (SF-36). The sample consisted of a group with Dual Diagnosis (DD; N=35), one with Severe Mental Illness alone (SMI; N=35) and another one with Substance Use Dependence alone (SUD; N=35). The sample was composed only by males. To assess the clinical correlates of SF-36 HRQOL, lineal regression analyses were carried out. Results: The DD group showed lower scores in most of the subscales, and in the mental health domain. The group with SUD showed in general a better state in the HRQOL while the group with SMI held an intermediate position with respect to the other two groups. Daily medication, suicidal attempts and daily number of coffees were significantly associated to HRQOL, especially in the DD group. Conclusions: The DD group showed lower self-reported mental health quality of life. Assessment of HRQOL in dual patients allows to identify specific needs in this population, and may help to establish therapeutic goals to improve interventions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Vertebral fracture assessments (VFAs) using dual-energy X-ray absorptiometry increase vertebral fracture detection in clinical practice and are highly reproducible. Measures of reproducibility are dependent on the frequency and distribution of the event. The aim of this study was to compare 2 reproducibility measures, reliability and agreement, in VFA readings in both a population-based and a clinical cohort. We measured agreement and reliability by uniform kappa and Cohen's kappa for vertebral reading and fracture identification: 360 VFAs from a population-based cohort and 85 from a clinical cohort. In the population-based cohort, 12% of vertebrae were unreadable. Vertebral fracture prevalence ranged from 3% to 4%. Inter-reader and intrareader reliability with Cohen's kappa was fair to good (0.35-0.71 and 0.36-0.74, respectively), with good inter-reader and intrareader agreement by uniform kappa (0.74-0.98 and 0.76-0.99, respectively). In the clinical cohort, 15% of vertebrae were unreadable, and vertebral fracture prevalence ranged from 7.6% to 8.1%. Inter-reader reliability was moderate to good (0.43-0.71), and the agreement was good (0.68-0.91). In clinical situations, the levels of reproducibility measured by the 2 kappa statistics are concordant, so that either could be used to measure agreement and reliability. However, if events are rare, as in a population-based cohort, we recommend evaluating reproducibility using the uniform kappa, as Cohen's kappa may be less accurate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a dual-trap optical tweezers setup which directly measures forces using linear momentum conservation. The setup uses a counter-propagating geometry, which allows momentum measurement on each beam separately. The experimental advantages of this setup include low drift due to all-optical manipulation, and a robust calibration (independent of the features of the trapped object or buffer medium) due to the force measurement method. Although this design does not attain the high-resolution of some co-propagating setups, we show that it can be used to perform different single molecule measurements: fluctuation-based molecular stiffness characterization at different forces and hopping experiments on molecular hairpins. Remarkably, in our setup it is possible to manipulate very short tethers (such as molecular hairpins with short handles) down to the limit where beads are almost in contact. The setup is used to illustrate a novel method for measuring the stiffness of optical traps and tethers on the basis of equilibrium force fluctuations, i.e., without the need of measuring the force vs molecular extension curve. This method is of general interest for dual trap optical tweezers setups and can be extended to setups which do not directly measure forces.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT Dual-trap optical tweezers are often used in high-resolution measurements in single-molecule biophysics. Such measurements can be hindered by the presence of extraneous noise sources, the most prominent of which is the coupling of fluctuations along different spatial directions, which may affect any optical tweezers setup. In this article, we analyze, both from the theoretical and the experimental points of view, the most common source for these couplings in dual-trap optical-tweezers setups: the misalignment of traps and tether. We give criteria to distinguish different kinds of misalignment, to estimate their quantitative relevance and to include them in the data analysis. The experimental data is obtained in a, to our knowledge, novel dual-trap optical-tweezers setup that directly measures forces. In the case in which misalignment is negligible, we provide a method to measure the stiffness of traps and tether based on variance analysis. This method can be seen as a calibration technique valid beyond the linear trap region. Our analysis is then employed to measure the persistence length of dsDNA tethers of three different lengths spanning two orders of magnitude. The effective persistence length of such tethers is shown to decrease with the contour length, in accordance with previous studies.