977 resultados para Dripping irrigation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In 2008, vegetable growers observed stunted lettuce plants showing signs of chlorosis and wilting. It was suspected that monochloramine in the recycled water used for irrigation, in combination with extreme environmental conditions (high irrigation water salinity and extreme heat), was responsible for these crop failures. A series of glasshouse studies was conducted to evaluate the impact of monochloramine concentration alone on iceberg lettuce seedlings, as well as in combination with high salinity and hot ambient temperatures. Monochloramine concentrations up to 9 and 15 mg L−1 Cl2 for continuous and initial irrigation only, respectively, did not affect the weight of iceberg lettuce heads (p > 0.05), while the combination of monochloramine (4–5 mg L−1 Cl2) and salinity (3,500 μS cm−1) did not significantly affect harvest measurements (p > 0.05). We therefore conclude that it is unlikely that monochloramine was responsible for the observed crop failures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reclamation of wastewater for irrigation has had an important role to play in Melbourne’s struggle to manage water resources as effectively as possible. Rapid growth within the first few years of the founding of the city led to a sanitary crisis, which provided the impetus for the construction of a large sewerage system. Interest in using the effluent from sewage treatment plants for irrigation gained attention in the late 1970s, but despite some activity in the early 1980s, it was not until 2005 that large-scale wastewater irrigation schemes became a reality. Successful to a degree, there have also been problems, and the future viability of one large irrigation scheme for commercial vegetable production is threatened by high salt concentrations in the treated wastewater. Greywater irrigation at the household level has also become commonplace in Melbourne over the last decade, but it is difficult to regulate and the health risks urgently need to be quantified. More recently, several third-pipe schemes, where treated wastewater is reticulated to households, have been commissioned with plans for many more, and treated stormwater is growing in popularity, particularly for irrigation of public open spaces.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O uso da irrigação na triticultura tem aumentado significativamente nos últimos anos no Brasil. Neste trabalho, objetivou-se avaliar a influência da irrigação na produtividade, na qualidade tecnológica da farinha e no sistema radicular do trigo. em experimento de campo no IAPAR, em Londrina, Paraná, a cultivar IPR 118 foi cultivada sob irrigação por aspersão convencional (Tratamento Irrigado) e sem irrigação (Tratamento Sequeiro). A produtividade foi determinada, colhendo-se três amostras de 25 m² por tratamento. Nestas mesmas amostras, procedeu-se à análise da qualidade tecnológica da farinha, sendo avaliada, entre outros parâmetros, a força de glúten (W). A avaliação do sistema radicular foi realizada após a colheita, no perfil de 0 a 45 cm de profundidade do solo, amostrando-se oito plantas em cada tratamento. O método da parede do perfil foi utilizado para determinar o número de raízes (NR) e o método do monólito para determinar a massa seca de raízes (MSR). A irrigação aumentou em três vezes a produtividade do trigo, porém diminuiu o W na farinha. Ainda assim, o valor de W encontrado no Tratamento Irrigado (249 10-4 J) foi suficiente para manter a classificação do trigo como tipo-pão, a mesma para o qual a cultivar IPR 118 é classificada. Os valores medidos de NR e a MSR foram iguais ou maiores no Tratamento Sequeiro.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Em solos tropicais, a distribuição dos nutrientes no solo em função da fertirrigação realizada por meio de irrigação localizada (gotejamento e/ou microaspersão), na cultura de citros, é pouco conhecida. Este trabalho teve por objetivo avaliar os padrões de distribuição de potássio, cálcio, magnésio e fósforo em solo tropical, em função da fertirrigação, aplicada por dois sistemas de irrigação localizada (microaspersão e gotejamento), sendo que o sistema por gotejamento era composto por uma e duas linhas laterais por linha de plantas, e o de microaspersão por apenas uma linha, e com três dotações hídricas (100%, 75% e 50%) da evapotranspiração da cultura (ETc), em um pomar de laranjeira. As fontes de fertilizantes utilizadas na fertirrigação foram o nitrato de amônio (fonte de N), o cloreto de potássio (fonte de K+) e o ácido fosfórico (fonte de P). Observouse que, sob o emissor, nos tratamentos com gotejamento, houve depleção nos teores de Ca++ e Mg++ desde a superfície do solo até 60 cm de profundidade em relação aos teores anteriores às fertirrigações, enquanto os teores de P aumentaram, principalmente na camada de 0 cm a 20 cm. Na microaspersão, esses efeitos não foram observados, ocorrendo distribuição mais homogênea desses nutrientes tanto na direção transversal à linha de plantas quanto em profundidade. As lâminas de irrigação aplicadas por irrigação localizada não interferem na distribuição de K+ aplicado por fertirrigação e do Ca++ e Mg++ no solo em profundidade, porém menores lâminas de irrigação promovem maior concentração de P na camada mais superficial do solo, e lâminas maiores carregam o P para camadas mais profundas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this research was to evaluate the growth of Tabebuia heptaphylla seedlings in distinct substrates with different amounts of urban waste compost and the relation between this growth and irrigation. A completely randomized experimental design was used, with a factorial arrangement of 15 substrates and 2 irrigation levels. The substrates were composed by the combination of different materials: urban waste, tanned cattle manure, vermiculite, soil and the commercial form Plantmax (R). For the study of the seedlings development, the following characteristics were evaluated: plant height, stem diameter at soil level, number of leaves, above ground dry matter, root system dry matter, relation between plant height and stem base diameter, Dickson quality index and relation between plant height and above ground dry matter. Evaluations of plant height, stem diameter at soil level and number of leaves were made at 75, 90, 105, 120, 135 and 150 days after sowing. According to the results, it was concluded that urban waste compost does not increase plant development. Significant differences in relation to the irrigation levels were found, with better results for the 150% irrigation level compared to 100% evapotranspiration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neste trabalho, ajustou-se um modelo matemático para quantificar o efeito do rendimento do motor elétrico sobre os custos de um sistema de bombeamento para irrigação na estrutura tarifária de energia elétrica convencional e horo-sazonal verde, bem como calcular o tempo de recuperação do capital investido no equipamento de maior rendimento. em seguida, o mesmo foi aplicado a um sistema de irrigação tipo pivô central em duas opções de rendimento do motor elétrico: 92,6% (linha padrão) e 94,3% (linha alto rendimento), sendo que o custo de aquisição do primeiro correspondeu a 70% do segundo. A potência do motor elétrico era de 100 cv. Os resultados mostraram que o modelo permitiu avaliar se um motor de alto rendimento era viável economicamente em relação ao motor-padrão em cada estrutura tarifária. Nas duas estruturas tarifárias, o motor de alto rendimento não foi viável. Na tarifa horo-sazonal verde, somente seria viável se seu rendimento fosse 4,46% superior ao do motor-padrão. Na tarifa convencional, somente seria viável se o ganho de rendimento superasse 2,71%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The aim of this study was to compare subgingival irrigation with tetracycline hydrochloride (TTC-HCL) as adjunctive treatment to scaling and root planning (SRP) on induced periodontitis in rats. Material and Methods: In 60 rats, periodontal disease was ligature-induced at the mandibular left first molar. After 7 days, the ligature was removed and all animals were submitted to SRP, and divided into 2 groups according to the following treatment: C (n=30) - subgingival irrigation with 1 mL of saline; T (n=30) - subgingival irrigation with 1 mL of TTC-HCL (50 mg/mL). Ten animals in each group were euthanized at 7, 15 and 30 days posttreatment. The histometric values were statistically analyzed (p<0.05). Results: In the histometric analysis, at 7, 15 and 30 days, Group T (0.72+/-0.05 mm(2), 0.57+/-0.14 mm(2), 0.62+/-0.07 mm(2)), showed less bone loss (p<0.05) than Group C (1.35+/-0.25 mm(2); 1.40+/-0.31 mm(2); 1.29+/-0.27 mm(2)), respectively. Conclusions: Subgingival irrigation with TTC-HCL was an effective adjunctive treatment for periodontal disease induced in rats.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A non-linear model is presented which optimizes the lay-out, as well as the design and management of trickle irrigation systems, to achieve maximum net benefit. The model consists of an objective function that maximizes profit at the farm level, subject to appropriate geometric and hydraulic constraints. It can be applied to rectangular shaped fields, with uniform or zero slope. The software used is the Gams-Minos package. The basic inputs are the crop-water-production function, the cost function and cost of system components, and design variables. The main outputs are the annual net benefit and pipe diameters and lengths. To illustrate the capability of the model, a sensitivity analysis of the annual net benefit for a citrus field is evaluated with respect to irrigated area, ground slope, micro-sprinkler discharge and shape of the field. The sensitivity analysis suggests that the greatest benefit is obtained with the smallest microsprinkler discharge, the greatest area, a square field and zero ground slope. The costs of the investment and energy are the components of the objective function that had the greatest effect in the 120 situations evaluated. (C) 1996 Academic Press Limited