742 resultados para Delivery reliability


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To identify risk factors for low birth weight (LBW) among live births by vaginal delivery and to determine if the disappearance of the association between LBW and socioeconomic factors was due to confounding by cesarean section. METHODS: Data were obtained from two population-based cohorts of singleton live births in Ribeirão Preto, Southeastern Brazil. The first one comprised 4,698 newborns from June 1978 to May 1979 and the second included 1,399 infants born from May to August 1994. The risks for LBW were tested in a logistic model, including the interaction of the year of survey and all independent variables under analysis. RESULTS: The incidence of LBW among vaginal deliveries increased from 7.8% in 1978--79 to 10% in 1994. The risk was higher for: female or preterm infants; newborns of non-cohabiting mothers; newborns whose mothers had fewer prenatal visits or few years of education; first-born infants; and those who had smoking mothers. The interaction of the year of survey with gestational age indicated that the risk of LBW among preterm infants fell from 17.75 to 8.71 in 15 years. The mean birth weight decreased more significantly among newborns from qualified families, who also had the highest increase in preterm birth and non-cohabitation. CONCLUSIONS: LBW among vaginal deliveries increased mainly due to a rise in the proportion of preterm births and non-cohabiting mothers. The association between cesarean section and LBW tended to cover up socioeconomic differences in the likelihood of LBW. When vaginal deliveries were analyzed independently, these socioeconomic differences come up again.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a direct power control (DPC) for three-phase matrix converters operating as unified power flow controllers (UPFCs). Matrix converters (MCs) allow the direct ac/ac power conversion without dc energy storage links; therefore, the MC-based UPFC (MC-UPFC) has reduced volume and cost, reduced capacitor power losses, together with higher reliability. Theoretical principles of direct power control (DPC) based on sliding mode control techniques are established for an MC-UPFC dynamic model including the input filter. As a result, line active and reactive power, together with ac supply reactive power, can be directly controlled by selecting an appropriate matrix converter switching state guaranteeing good steady-state and dynamic responses. Experimental results of DPC controllers for MC-UPFC show decoupled active and reactive power control, zero steady-state tracking error, and fast response times. Compared to an MC-UPFC using active and reactive power linear controllers based on a modified Venturini high-frequency PWM modulator, the experimental results of the advanced DPC-MC guarantee faster responses without overshoot and no steady-state error, presenting no cross-coupling in dynamic and steady-state responses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes a new methodology to reduce the probability of occurring states that cause load curtailment, while minimizing the involved costs to achieve that reduction. The methodology is supported by a hybrid method based on Fuzzy Set and Monte Carlo Simulation to catch both randomness and fuzziness of component outage parameters of transmission power system. The novelty of this research work consists in proposing two fundamentals approaches: 1) a global steady approach which deals with building the model of a faulted transmission power system aiming at minimizing the unavailability corresponding to each faulted component in transmission power system. This, results in the minimal global cost investment for the faulted components in a system states sample of the transmission network; 2) a dynamic iterative approach that checks individually the investment’s effect on the transmission network. A case study using the Reliability Test System (RTS) 1996 IEEE 24 Buses is presented to illustrate in detail the application of the proposed methodology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although vaccination is still the most cost-effective strategy for tuberculosis control, there is an urgent need for an improved vaccine. Current BCG vaccine lacks efficacy in preventing adult pulmonary tuberculosis, the most prevalent form of the disease. Targeting nasal mucosa, Mycobacterium tuberculosis infection site, will allow a simpler, less prone to risk of infection and more effective immunization against disease. Due to its biodegradable, immunogenic and mucoadhesive properties, chitosan particulate delivery systems can act both as carrier and as adjuvant, improving the elicited immune response. In this study, BCG was encapsulated in alginate and chitosan microparticles, via a mild ionotropic gelation procedure with sodium tripolyphosphate as a counterion. The particulate system developed shows effective modulation of BCG surface physicochemical properties, suitable for mucosal immunization. Intracellular uptake was confirmed by effective transfection of human macrophage cell lines.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To determine changes in the incidence of vaginal deliveries, cesarean sections, and forceps deliveries and their potential association with fetal, early neonatal, and perinatal mortality rates over time. METHODS: A retrospective study was carried out and the occurrence of deliveries supervised by university services between January 1991 and December 2000 was determined. Data regarding fetal, early neonatal, and perinatal deaths were assessed using obstetric and pediatric records and autopsy reports. RESULTS: Of a total of 33,360 deliveries, the incidence of vaginal deliveries, cesarean sections, and forceps deliveries was relatively steady (around 60, 30, and 10%, respectively) while, at the same time, there was a marked reduction in fetal mortality (from 33.3 to 13.0‰), early neonatal mortality (from 30.6 to 9.0‰), and perinatal mortality (from 56.4 to 19.3‰). CONCLUSIONS: The marked reduction in perinatal mortality rates seen during the study period without an increase in cesarean sections indicates that the decrease in perinatal mortality was not impacted by cesarean section rates. The plausible hypothesis seems to be that the reduction in perinatal mortality of deliveries performed under the supervision of university services was more likely to be associated with better neonatal care rather than the mode of delivery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Immunisation against M. tuberculosis with current available BCG vaccine lacks efficacy in preventing adult pulmonary tuberculosis. Targeting nasal mucosa is an attractive option for a more effective immunization. The delivery of BCG via the intranasal route involves overcoming barriers such as crossing the physical barrier imposed by the mucus layer and ciliar remotion, cellular uptake and intracellular trafficking by antigen presenting cells. Due to its biodegradable, immunogenic and mucoadhesive properties, chitosan particulate delivery systems can act both as vaccine carrier and adjuvant, improving the elicited immune response. In this study, different combinations of Chitosan/Alginate/TPP microparticles with BCG were produced as vaccine systems. The developed microparticle system successfully modulates BCG surface physicochemical properties and promotes effective intracellular uptake by human macrophage cell lines Preliminary immune responses were evaluated after s.c. and intranasal immunisation of BALB/c mice. BCG vaccination successfully stimulated the segregation of IgG2a and IgG1, where intranasal immunisation with chitosan/alginate particulate system efficiently elicited a more equilibrated cellular/humoral immune response.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a methodology supported on the data base knowledge discovery process (KDD), in order to find out the failure probability of electrical equipments’, which belong to a real electrical high voltage network. Data Mining (DM) techniques are used to discover a set of outcome failure probability and, therefore, to extract knowledge concerning to the unavailability of the electrical equipments such us power transformers and high-voltages power lines. The framework includes several steps, following the analysis of the real data base, the pre-processing data, the application of DM algorithms, and finally, the interpretation of the discovered knowledge. To validate the proposed methodology, a case study which includes real databases is used. This data have a heavy uncertainty due to climate conditions for this reason it was used fuzzy logic to determine the set of the electrical components failure probabilities in order to reestablish the service. The results reflect an interesting potential of this approach and encourage further research on the topic.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess the association between pre-gestational obesity and weight gain with cesarean delivery and labor complications. METHODS: A total of 4,486 women 20-28 weeks pregnant attending general prenatal care clinics of the national health system in Brazil from 1991 to 1995 were enrolled and followed up through birth. Body mass index categories based on prepregnancy weight and total weight gain were calculated. Associations between body mass index categories and labor complications were adjusted through logistic regression analysis. RESULTS: Obesity was present in 308 (6.9%) patients. Cesarean delivery was performed in 164 (53.2%) obese, 407 (43.1%) pre-obese, 1,045 (35.1%) normal weight and 64 (24.5%) underweight women. The relative risk for cesarean delivery in obese women was 1.8 (95% CI: 1.5-2.0) compared to normal weight women. Greater weight gain was particularly associated with cesarean among the obese (RR 4th vs 2nd weight gain quartile 2.2; 95% CI: 1.4-3.2). Increased weight at the beginning of pregnancy was associated with a significantly higher adjusted risk of meconium with vaginal delivery and perinatal death and infection in women submitted to cesarean section. Similarly, greater weight gain during pregnancy increased the risk for meconium and hemorrhage in women submitted to vaginal delivery and for prematurity with cesarean. CONCLUSIONS: Pre-gestational obesity and greater weight gain independently increase the risk of cesarean delivery, as well as of several adverse outcomes with vaginal delivery. These findings provide further evidence of the negative effects of prepregnancy obesity and greater gestational weight gain on pregnancy outcomes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Acute respiratory infections are usual in children under three years old occurring in upper respiratory tract, having an impact on child and caregiver’s quality of life predisposing to otitis media or bronchiolitis. There are few valid and reliable measures to determine the child’s respiratory condition and to guide the physiotherapy intervention. Aim: To assess the intra and inter rater reliability of nasal auscultation, to analyze the relation between sounds’ classification and middle ear’s pressure and compliance as well as with the Clinical Severity Score. Methods: A cross-sectional observational study was composed by 125 nursery children aged up to three years old. Tympanometry, pulmonary and nasal auscultation and application of Clinical Severity Score were performed to each child. Nasal auscultation sounds’ were recorded and sent to 3 blinded experts, that classified, as “obstructed” and “unobstructed”, with a 48 hours interval, in order to analyze inter and intra rater reliability. Results: Nasal auscultation revealed a substantial inter and intra rater reliability (=0,749 and evaluator A - K= 0,691; evaluator B - K= 0,605 and evaluator C - K= 0,724, respectively). Both ears’ pressure was significantly lower in children with an "unobstructed" nasal sound when compared with an “obstructed” nasal sound (t=-3,599, p<0,001 in left ear; t=-2,258, p=0,026 in right ear). Compliance in both ears was significantly lower in children with an "obstructed" nasal sound when compared with “unobstructed” nasal sound (t=-2,728, p=0,007 in left ear; t=-3,830, p<0,001 in right ear). There was a statistically significant association between sounds’ classification and tympanograms types in both ear’s (=11,437, p=0,003 in left ear; =13,535, p=0,001 in right ear). There was a trend to children with an "unobstructed" nasal sound that had a lower clinical severity score when compared with “obstructed” children. Conclusion: It was observed a good intra and substantial inter reliability for nasal auscultation. Nasal auscultation sounds’ classification was related to middle ears’ pressure and compliance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Projeto para obtenção do grau de Mestre em Engenharia Informática e de Computadores

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose – Quantitative instruments to assess patient safety culture have been developed recently and a few review articles have been published. Measuring safety culture enables healthcare managers and staff to improve safety behaviours and outcomes for patients and staff. The study aims to determine the AHRQ Hospital Survey on Patient Safety Culture (HSPSC) Portuguese version's validity and reliability. Design/methodology/approach – A missing-value analysis and item analysis was performed to identify problematic items. Reliability analysis, inter-item correlations and inter-scale correlations were done to check internal consistency, composite scores. Inter-correlations were examined to assess construct validity. A confirmatory factor analysis was performed to investigate the observed data's fit to the dimensional structure proposed in the AHRQ HSPSC Portuguese version. To analyse differences between hospitals concerning composites scores, an ANOVA analysis and multiple comparisons were done. Findings – Eight of 12 dimensions had Cronbach's alphas higher than 0.7. The instrument as a whole achieved a high Cronbach's alpha (0.91). Inter-correlations showed that there is no dimension with redundant items, however dimension 10 increased its internal consistency when one item is removed. Originality/value – This study is the first to evaluate an American patient safety culture survey using Portuguese data. The survey has satisfactory reliability and construct validity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis presents the Fuzzy Monte Carlo Model for Transmission Power Systems Reliability based studies (FMC-TRel) methodology, which is based on statistical failure and repair data of the transmission power system components and uses fuzzyprobabilistic modeling for system component outage parameters. Using statistical records allows developing the fuzzy membership functions of system component outage parameters. The proposed hybrid method of fuzzy set and Monte Carlo simulation based on the fuzzy-probabilistic models allows catching both randomness and fuzziness of component outage parameters. A network contingency analysis to identify any overloading or voltage violation in the network is performed once obtained the system states. This is followed by a remedial action algorithm, based on Optimal Power Flow, to reschedule generations and alleviate constraint violations and, at the same time, to avoid any load curtailment, if possible, or, otherwise, to minimize the total load curtailment, for the states identified by the contingency analysis. For the system states that cause load curtailment, an optimization approach is applied to reduce the probability of occurrence of these states while minimizing the costs to achieve that reduction. This methodology is of most importance for supporting the transmission system operator decision making, namely in the identification of critical components and in the planning of future investments in the transmission power system. A case study based on Reliability Test System (RTS) 1996 IEEE 24 Bus is presented to illustrate with detail the application of the proposed methodology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To analyze reliability of a self-applied questionnaire on substance use and misuse among adolescent students. METHODS: Two cross-sectional studies were carried out for the instrument test-retest. The sample comprised male and female students aged 1119 years from public and private schools (elementary, middle, and high school students) in the city of Salvador, Northeastern Brazil, in 2006. A total of 591 questionnaires were applied in the test and 467 in the retest. Descriptive statistics, the Kappa index, Cronbach's alpha and intraclass correlation were estimated. RESULTS: The prevalence of substance use/misuse was similar in both test and retest. Sociodemographic variables showed a "moderate" to "almost perfect" agreement for the Kappa index, and a "satisfactory" (>0.75) consistency for Cronbach's alpha and intraclass correlation. The age which psychoactive substances (tobacco, alcohol, and cannabis) were first used and chronological age were similar in both studies. Test-retest reliability was found to be a good indicator of students' age of initiation and their patterns of substance use. CONCLUSIONS: The questionnaire reliability was found to be satisfactory in the population studied.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this paper is to develop models for experimental open-channel water delivery systems and assess the use of three data-driven modeling tools toward that end. Water delivery canals are nonlinear dynamical systems and thus should be modeled to meet given operational requirements while capturing all relevant dynamics, including transport delays. Typically, the derivation of first principle models for open-channel systems is based on the use of Saint-Venant equations for shallow water, which is a time-consuming task and demands for specific expertise. The present paper proposes and assesses the use of three data-driven modeling tools: artificial neural networks, composite local linear models and fuzzy systems. The canal from Hydraulics and Canal Control Nucleus (A parts per thousand vora University, Portugal) will be used as a benchmark: The models are identified using data collected from the experimental facility, and then their performances are assessed based on suitable validation criterion. The performance of all models is compared among each other and against the experimental data to show the effectiveness of such tools to capture all significant dynamics within the canal system and, therefore, provide accurate nonlinear models that can be used for simulation or control. The models are available upon request to the authors.