883 resultados para Compound Matrix
Resumo:
The compound Zr0.75Ce0.08Nd0.17O1.92 was investigated as part of a much larger electrical conductivity/microstructure study of the systems ZrO2-CeO2-M2O3 (where M=Nd, Sm, ..., Yb) [Solid State Ionics (2002)]. Electrical conductivity measurements performed in air at 800 degreesC showed significant conductivity degradation over a period of 200 h. Investigation of the annealed and as-fired specimens by ATEM revealed the presence of an emerging, ordered pyrochlore-type phase within the Zr0.75Ce0.08Nd0.17O1.92 defect-fluorite solid solution at much lower dopant levels than observed previously for zirconia binary systems. (C) 2002 Elsevier Science B.V. All rights reserved.
Resumo:
The Lanczos algorithm is appreciated in many situations due to its speed. and economy of storage. However, the advantage that the Lanczos basis vectors need not be kept is lost when the algorithm is used to compute the action of a matrix function on a vector. Either the basis vectors need to be kept, or the Lanczos process needs to be applied twice. In this study we describe an augmented Lanczos algorithm to compute a dot product relative to a function of a large sparse symmetric matrix, without keeping the basis vectors.
Resumo:
Background - Marfan syndrome (MS) is a genetic disorder caused by a mutation in the fibrillin gene FBN1. Bicuspid aortic valve (BAV) is a congenital heart malformation of unknown cause. Both conditions are associated with ascending aortic aneurysm and premature death. This study examined the relationship among the secretion of extracellular matrix proteins fibrillin, fibronectin, tenascin, and vascular smooth muscle cell (VSMC) apoptosis. The role of matrix metalloproteinase (MMP)- 2 in VSMC apoptosis was studied in MS aneurysm. Methods and Results - Aneurysm tissue was obtained from patients undergoing surgery ( MS: 4 M, 1 F, age 27 - 45 years; BAV: 3 M, 2 F, age 28 - 65 years). Normal aorta from subjects with nonaneurysm disease was also collected ( 4 M, 1 F, age 23 - 93 years). MS and BAV aneurysm histology showed areas of cystic medial necrosis (CMN) without inflammatory infiltrate. Immunohistochemical study of cultured MS and BAV VSMC showed intracellular accumulation and reduction of extracellular distribution of fibrillin, fibronectin, and tenascin. Western blot showed no increase in expression of fibrillin, fibronectin, or tenascin in MS or BAV VSMC and increased expression of MMP-2 in MS VSMCs. There was 4-fold increase in loss of cultured VSMC incubated in serum-free medium for 24 hours in both MS ( 27 +/- 8%) and BAV ( 32 +/- 14%) compared with control ( 7 +/- 5%). Conclusions - In MS and BAV there is alteration in both the amount and quality of secreted proteins and an increased degree of VSMC apoptosis. Up-regulation of MMP-2 might play a role in VSMC apoptosis in MS VSMC. The findings suggest the presence of a fundamental cellular abnormality in BAV thoracic aorta, possibly of genetic origin.
Resumo:
Matrix metalloproteinases (MMPs) are a family of enzymes implicated in the degradation and remodeling of extracellular matrix and in vascularization. They are also involved in pathologic processes such as tumor invasion and metastasis in experimental cancer models and in human malignancies. We used gelatin zymography and inummohistochemistry to determine whether MMP-2 and MMP-9 are present in canine tumors and normal tissues and whether MMP production correlates with clinicopathologic parameters of prognostic importance. High levels of pro-MMP-9, pro-MMP-2, and active MMP-2 were detected in most canine tumors. Significantly higher MMP levels were measured in canine tumors than in nontumors, malignancies had higher MMP levels than benign tumors, and sarcomas had higher active MMP-2 than carcinomas. Cartilaginous tumors produced higher MMP levels than did nonsarcomatous malignancies, benign tumors, and normal tissues, and significantly greater MMP-2 than osteosarcomas and fibrosarcomas. Pro-MMP-9 production correlated with the histologic grade of osteosarcomas. The 62-kd form of active MMP-2 was detected only in high-grade, p53-positive, metastatic malignancies. Zymography proved to be a sensitive and quantitative technique for the assessment of MMP presence but has the limitation of requiring fresh tissue; inummohistochemistry is qualitative and comparatively insensitive but could be of value in archival studies. MMP presence was shown in a range of canine tumors, and their link to tumor type and grade was demonstrated for the first time. This study will allow a substantially improved evaluation of veterinary cancer patients and provides baseline information necessary for the design of clinical trials targeting MMPs.
Resumo:
FeBr2 reacts with the S2C2(CN)22- ion (1:1 ratio) in the presence of an excess of t-BuNC in THF to give the mixed ligand [Fe(S2C2(CN)2)(t-BuNC) 4] compound. This neutral product with a formal oxidation state of two for the iron atom was characterized by conductivity measurements, and, i.r., Mössbauer, 13C and 1H n.m.r. spectroscopy. There is a Fe-C p back-donation strengthened towards isocyanide ligands, according to the data of 13C, 1H n.m.r. and Mössbauer spectroscopy.
Resumo:
For modern consumer cameras often approximate calibration data is available, making applications such as 3D reconstruction or photo registration easier as compared to the pure uncalibrated setting. In this paper we address the setting with calibrateduncalibrated image pairs: for one image intrinsic parameters are assumed to be known, whereas the second view has unknown distortion and calibration parameters. This situation arises e.g. when one would like to register archive imagery to recently taken photos. A commonly adopted strategy for determining epipolar geometry is based on feature matching and minimal solvers inside a RANSAC framework. However, only very few existing solutions apply to the calibrated-uncalibrated setting. We propose a simple and numerically stable two-step scheme to first estimate radial distortion parameters and subsequently the focal length using novel solvers. We demonstrate the performance on synthetic and real datasets.
Resumo:
A model to simulate the conductivity of carbon nanotube/polymer nanocomposites is presented. The proposed model is based on hopping between the fillers. A parameter related to the influence of the matrix in the overall composite conductivity is defined. It is demonstrated that increasing the aspect ratio of the fillers will increase the conductivity. Finally, it is demonstrated that the alignment of the filler rods parallel to the measurement direction results in higher conductivity values, in agreement with results from recent experimental work.
Resumo:
This paper presents the Direct Power Control of Three-Phase Matrix Converters (DPC-MC) operating as Unified Power Flow Controllers (UPFC). Since matrix converters allow direct AC/AC power conversion without intermediate energy storage link, the resulting UPFC has reduced volume and cost, together with higher reliability. Theoretical principles of DPC-MC method are established based on an UPFC model, together with a new direct power control approach based on sliding mode control techniques. As a result, active and reactive power can be directly controlled by selection of an appropriate switching state of matrix converter. This new direct power control approach associated to matrix converters technology guarantees decoupled active and reactive power control, zero error tracking, fast response times and timely control actions. Simulation results show good performance of the proposed system.
Resumo:
This paper presents a predictive optimal matrix converter controller for a flywheel energy storage system used as Dynamic Voltage Restorer (DVR). The flywheel energy storage device is based on a steel seamless tube mounted as a vertical axis flywheel to store kinetic energy. The motor/generator is a Permanent Magnet Synchronous Machine driven by the AC-AC Matrix Converter. The matrix control method uses a discrete-time model of the converter system to predict the expected values of the input and output currents for all the 27 possible vectors generated by the matrix converter. An optimal controller minimizes control errors using a weighted cost functional. The flywheel and control process was tested as a DVR to mitigate voltage sags and swells. Simulation results show that the DVR is able to compensate the critical load voltage without delays, voltage undershoots or overshoots, overcoming the input/output coupling of matrix converters.
Resumo:
This paper presents a direct power control (DPC) for three-phase matrix converters operating as unified power flow controllers (UPFCs). Matrix converters (MCs) allow the direct ac/ac power conversion without dc energy storage links; therefore, the MC-based UPFC (MC-UPFC) has reduced volume and cost, reduced capacitor power losses, together with higher reliability. Theoretical principles of direct power control (DPC) based on sliding mode control techniques are established for an MC-UPFC dynamic model including the input filter. As a result, line active and reactive power, together with ac supply reactive power, can be directly controlled by selecting an appropriate matrix converter switching state guaranteeing good steady-state and dynamic responses. Experimental results of DPC controllers for MC-UPFC show decoupled active and reactive power control, zero steady-state tracking error, and fast response times. Compared to an MC-UPFC using active and reactive power linear controllers based on a modified Venturini high-frequency PWM modulator, the experimental results of the advanced DPC-MC guarantee faster responses without overshoot and no steady-state error, presenting no cross-coupling in dynamic and steady-state responses.
Resumo:
Mestrado em Medicina Nuclear.
Resumo:
Human Computer Interaction (HCl) is to interaction between computers and each person. And context-aware (CA) is very important one of HCI composition. In particular, if there are sequential or continuous tasks between users and devices, among users, and among devices etc, it is important to decide the next action using right CA. And to take perfect decision we have to get together all CA into a structure. We define that structure is Context-Aware Matrix (CAM) in this article. However to make exact decision is too hard for some problems like low accuracy, overhead and bad context by attacker etc. Many researcher has been studying to solve these problems. Moreover, still it has weak point HCI using in safety. In this Article, we propose CAM making include best selecting Server in each area. As a result, moving users could be taken the best way.
Resumo:
Copyright © 2010 Elsevier B.V. All rights reserved.
Resumo:
A produção de vinho é uma actividade de elevada importância ao nível económico, ambiental e social. Como tal, a protecção da vinha e/ou da uva através da utilização de pesticidas assume um papel fundamental nesta actividade, permitindo um aumento no rendimento da produção. No entanto, a transferência destes compostos da uva para o vinho é inevitável, ocorrendo, na maioria dos casos, em quantidades reduzidas. Apesar de, geralmente, a quantidade de pesticidas que pode ser transferida para o vinho não apresentar problemas relevantes para a saúde pública, o desenvolvimento de metodologias que permitam garantir um controlo rigoroso da qualidade do vinho é de elevada importância. O controlo deste produto, assim como de qualquer produto alimentar, não deve ser de certa forma virtual, levando a uma desconfiança crescente do consumidor. Ao longo deste trabalho foram desenvolvidos dois métodos para a determinação de pesticidas em diferentes tipos de vinhos, por SPME-GC-MS/MS. O primeiro método desenvolvido visa a determinação de 8 pesticidas organofosforados e o segundo método permite a determinação de 7 pesticidas, 4 organoclorados e 3 dicarboximidas. Foram estudadas quatro matrizes diferentes: vinho branco do Douro, vinho tinto do Douro, vinho branco do Porto e vinho tinto do Porto. As metodologias adoptadas permitiram a obtenção de bons resultados, apesar das condições adoptadas não serem as mais vantajosas para alguns dos compostos estudados. Dada a complexidade das matrizes, a detecção por espectrometria de massa mostrou ser fundamental para a identificação inequívoca de cada um dos pesticidas. Verificaram-se, de um modo geral, bons resultados ao nível da linearidade, para as gamas de concentrações escolhidas, para os dois métodos. Obtiveram-se também bons resultados para os limites de detecção e quantificação, cujos valores se situam abaixo dos limites máximos de resíduos para as uvas, impostos pela regulamentação europeia, para a maioria dos compostos. No caso dos organofosforados, os limites de detecção variam entre 0,05 μg/L e 13,00 μg/L para os pesticidas clorpirifos-metilo e metidatião, respectivamente. Os limites de quantificação variam entre 0,18 μg/L e 43,32 μg/L, também para os pesticidas clorpirifos-metilo e metidatião. No que se refere ao método para os pesticidas organoclorados e dicarboximidas, foram calculados vários limites de detecção para cada composto, em cada matriz estudada, a partir das rectas de calibração diárias, resultando num conjunto de valores com variações significativas entre cada um, para o mesmo pesticida e na mesma matriz. No entanto, apenas os limites de quantificação foram validados, recorrendo-se aos estudos de repetibilidade e precisão intermédia. Obtiveram-se os seguintes limites de quantificação: captana 52,10 μg/L; clortalonil 20,95 μg/L; dicofol 4,37 μg/L; folpete 93,60 μg/L; iprodiona 274,70 μg/L; procimidona 76,04 μg/L e vinclozolina 10,03 μg/L. Os pesticidas metidatião e captana apresentam-se como os compostos mais problemáticos, uma vez que os limites de quantificação obtidos não permitem a garantia do cumprimento dos limites máximos de resíduos regulamentados. Demonstra-se também que, apesar do efeito de matriz ser significativo na determinação de todos os compostos analisados, o mesmo pode ser atenuado, procedendo-se às calibrações nas respectivas matrizes. Observaram-se variações significativas ao nível da resposta do equipamento ao longo do tempo, quer pela alteração das condições operatórias, quer pela decomposição de alguns compostos ao longo do tempo. Este efeito, evidenciado nos estudos das precisões intermédias e repetibilidades, levou à adopção de um método de validação diferente para a determinação de pesticidas organoclorados e dicarboximidas, recorrendo-se então a calibrações diárias e sequências de trabalho mais pequenas.