914 resultados para Composite polymer blend. Polyethylene terephthalate. Polyethylenemethyl acrylate. And cotton linter
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Light dynamics is a relevant phenomenon with respect to esthetic restorations, as incorrect analysis of the optical behavior of natural dentition may lead to potential clinical failures. The nature of incident light plays a major role in determining the amount of light transmission or reflection, and how an object is perceived depends on the nature of the light source. Natural teeth demonstrate translucency, opalescence, and fluorescence, all of which must be replicated by restorative materials in order to achieve clinical success. Translucency is the intermediary between complete opacity and complete transparency, making its analysis highly subjective. In nature, the translucency of dental enamel varies from tooth to tooth, and from individual to individual. Therefore, four important factors must be considered when appraising translucency. Presence or absence of color, thickness of the enamel, degree of translucency, and surface texture are essential components when determining translucency. State-of-the-art resin composites provide varying shades and opacities that deliver a more faithful reproduction of the chromaticity and translucency/opacity of enamel and dentin. This enables the attainment of individualized and customized composite restorations. The objective of this article is to provide a review of the phenomena of translucency and opacity in the natural dentition and composite resins, under the scope of optics, and to describe how to implement these concepts in the clinical setting.CLINICAL SIGNIFICANCEChoosing composite resins, based on optical properties alone, in order to mimic the properties of natural tooth structures, does not necessarily provide a satisfactory esthetic outcome. In many instances, failure ensues from incorrect analysis of the optical behaviors of the natural dentition as well as the improper use of restorative materials. Therefore, it is necessary to implement a technique that enables a restorative material to be utilized to its full potential to correctly replicate the natural teeth.(J Esthet Restor Dent 23:73-88, 2011).
Resumo:
Objective: A restorative material for Class III cavities must, besides being functional, be esthetically satisfactory, providing good working conditions and several shade and color options. A clinical evaluation was initiated to compare the suitability of resin composite and glass-ionomer cement materials for such restorations.Method and materials: Forty-two Class III conservative cavities, esthetically important because of facial extensions, were selected. Resin composite restorations were placed in 21 cavities, and the remaining 21 were restored with glass-ionomer cement. The following characteristics were studied: color or-esthetics, anatomic shape, surface texture, staining, marginal infiltration, dental plaque retention, and occurrence of fracture. After 24 months, the restorations were evaluated.Results: the only statistically significant difference between the resin composite and glass-ionomer cement restorations in the experimental period involved color or esthetics.Conclusion: Resin composites and glass-ionomer materials provide excellent functional and esthetic results in Class III cavities when properly indicated.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
O mercado de embalagens de poli(tereftalato de etileno) -PET- para acondicionamento de refrigerantes, água mineral, sucos concentrados e óleos comestíveis apresenta polímeros de diferentes tipos, que foram desenvolvidos para personalizar o atendimento a clientes desejosos de propriedades melhores e mais específicas, principalmente em termos de massa molar. No caso do PET, assim como na indústria da reciclagem do polímero, o ensaio de viscosidade intrínseca é muito usado para determinar a massa molar. Este trabalho apresenta os resultados de viscosidade intrínseca de PET advindo de embalagens de várias marcas de refrigerantes, sucos e óleos de soja. Amostras de cada embalagem foram dissolvidas em solução de fenol-tetracloroetano (60:40 em peso) e o fluxo das mesmas em um viscosímetro Cannon-Fenske a 30 °C para medir a viscosidade relativa, que foi convertido para viscosidade intrínseca. Os resultados mostraram uma variação no valor da propriedade conforme se variava o volume, tipo e a marca do produto envasado. Para as 21 amostras analisadas, os resultados variaram de 0,70 a 0,79 dL/g. Portanto, uma melhor seleção das embalagens pode ajudar os recicladores na obtenção de produtos melhores, com menor variação na massa molar. Os valores de densidade obtidos apresentaram uma pequena variação, que torna-se maior quando transformados em cristalinidade.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Composites, made of lead zirconate titanate (PZT) ceramic powder and castor oil-based polyurethane (PU), were prepared in the film form. The films were obtained in the thickness range 100-300 mum using up to 50/50 vol.% of ceramic. Another composite (PZT/C/PU) was obtained by adding a small amount (1.0 vol.%) of graphite (C) to the PZT/PU composite. By increasing the conductivity of PU-containing graphite, polarization of PZT could be carried out with better efficiency. A comparison of piezo- and pyroelectric activities and spatial distribution of polarization between graphite doped and undoped composites reveal the advantages of using semiconductor filler. These composites were used as sensors to detect acoustic emission (AE). The detection was made using two simulated sources of AE, i.e., ball bearing drop and pencil lead break. PZT/C/PU composite was able to detect both flexural and extensional components of wave vibration. (C) 2002 Elsevier B.V. B.V. All rights reserved.
Resumo:
The aim of this study was to evaluate the effect of ageing in distilled water on the hardness and compressive strength of a direct composite resin Z100, a feldspatic porcelain (Noritake) and three indirect composites (Artglass, Solidex and Targis). For the Vickers hardness tests, five disk-shaped specimens (2 x 4 mm) of each material were prepared according to the manufacturers' instructions. The hardness tests were conducted using a Vickers diamond indentor. Compressive strength measurements were recorded on cylindrical specimens with a diameter of 6 mm and a length of 12 mm. The compression tests were carried out with a constant cross-head speed of 0.5 mm min(-1) on a mechanical test machine. For each material, 10 specimens were tested after 7 days of dry storage at 37 +/- 1 degreesC and 10 specimens were tested after water storage at 37 +/- 1 degreesC for 180 days. Noritake porcelain specimens showed higher hardness values than the composites. Among the composite materials, Z100 promoted the highest VHN values, regardless of the ageing periods. The results showed that Solidex and Z100 had the highest compressive strength values. Ageing in water reduced the hardness for all composites, but had no long-term effect on the compressive strength.
Resumo:
Significant progress is being made in the photovoltaic energy conversion using organic semiconducting materials. One of the focuses of attention is the morphology of the donor-acceptor heterojunction at the nanometer scale, to ensure efficient charge generation and loss-free charge transport at the same time. Here, we present a method for the controlled, sequential design of a bilayer polymer cell architecture that consists of a large interface area with connecting paths to the respective electrodes for both materials. We used the surface-directed demixing of a donor conjugated/guest polymer blend during spin coating to produce a nanostructured interface, which was, after removal of the guest with a selective solvent, covered with an acceptor layer. With use of a donor poly(p-phenylenevinylene) derivative and the acceptor C-60 fullerene, this resulted in much-improved device performance, with external power efficiencies more than 3 times higher than those reported for that particular material combination so far.
Resumo:
Thin polymer films were deposited from acetylene and argon mixtures by plasma immersion ion implantation and deposition. The effect of the pulse frequency, v, on molecular structure, optical gap, contact angle and hardness of the films was investigated. It was observed progressive dehydrogenation of the samples and increment in the concentration of unsaturated carbon bonds as the pulse frequency was increased. Film hardness and contact angle increased and optical gap decreased with v. These results are interpreted in terms of the chain unsaturation and crosslinking.
Resumo:
During the 1999/00 and 2000/01 seasons, sliced 'Tommy Atkins' mangoes were packaged with three different types of polymeric films; polypropylene (PP) cups, low-density polyethylene (LPDE) bags or polyethylene terephthalate (PET) clamshell trays, and stored at 3°C for 2 weeks. The mango chunks were evaluated for flavor, appearance, colour, total soluble solids (TSS), total titratable acidity (TTA), ascorbic acid (AA) contents, O2 and CO 2 concentration in the packages, as well as respiration. Shelf life based on visual appearance was 14 days, with the products showing good appearance and agreeable aroma. The TTA content in chunks packaged in PP cups or PET trays were reduced during the storage, and with the color changing from light yellow to dark yellow. The chunks respiration in PP cups or LPDE bags were 64.6 and 87.9 mL CO2.kg-1.h-1, and in PP cups or PET trays were 45.86 and 43.92 mL CO2.kg-1.h -1, respectively for 1999/00 and 2000/01 seasons. The percentages of O2 and CO2 in the packages were stabilized after 2-4 hours, and the atmosphere had 11-17% and 1-10% of them. The microbiological content was lower than the allowed. No differences were observed between the seasons, and the best packages were the cups.
Resumo:
Objective: To measure 2-week postoperative sensitivity in Class II composite restorations placed with a self-etching adhesive (Clearfil SE Bond) or a total-etch adhesive (Prime&Bond NT) with or without a flowable composite as cervical increment. Method and materials: Upon approval by the University of Guarulhos Committee on Human Subjects, 100 restorations were inserted in 46 patients who required Class II restorations in their molars and premolars. Enamel and dentin walls were conditioned with a self-etching primer (for Clearfil SE Bond) or etched with 34% phosphoric acid (for Prime&Bond NT). A 1- to 2-mm-thick increment of a flowable composite (Filtek Flow) was used in the proximal box in 50% of the restorations of each adhesive. Preparations were restored with a packable composite (Surefil). The restorations were evaluated preoperatively and 2 weeks postoperatively for sensitivity to cold, air, and masticatory forces using a visual analog scale. Marginal integrity of the accessible margins was also evaluated. Statistical analysis used a mixed linear model with subject as a random effect. Results: Ninety-eight teeth from 44 subjects were observed at 2 weeks. The type of adhesive and use of flowable composite had no significant effects or interaction for any of the four outcomes of interest, ie, change from baseline to 2 weeks in sensitivity and response time for the cold or air stimulus. For the air stimulus, the overall average change from baseline was not significant for either sensitivity or response time. For the cold stimulus, the overall average change from baseline was significant for both sensitivity and response time. No case of sensitivity to masticatory forces was observed. Conclusion: No differences in postoperative sensitivity were observed between a self-etch adhesive and a total-etch adhesive at 2 weeks. The use of flowable composite did not decrease postoperative sensitivity.
Resumo:
The respiratory and storage behavior of fresh cut 'Tommy Atkins' mango, naturally ripened (NR) or with use of ethylene (RE), were studied. Fruits were selected, washed and disinfected (200 mgCl.L-1) and stored for 12 hours at 10°C. After this period, they were processed under hygienic conditions at 10°C, packaged in polyethylene terephthalate (PET) trays or in styrofoam trays wrapped with stretchable polyvinyl chloride (PVC) film and stored for up to 15 days at 3°C. The products were evaluated regarding the evolution of internal atmosphere in the packing (O2 and CO 2), development of weight, appearance, shelf life and consumer acceptability. The respiratory rate was measured before and after processing every two hours. The yield of 'Tommy Atkins' mango to produce fresh cut product was 48.09±0.95%. Increase of the respiration rate of both mango samples was verified one hour after the preparation (NR = 17.75 mL CO 2.kg-1.h-1; RE = 28.29 mL CO 2.kg-1.h-1), followed by stabilization at 3.76 and 8.07 mL CO2/kg.h, respectively. The percentage of O2 in packages was stable in all treatments, 15-20% in PVC trays, 18-20% in PET tray. The percentage of CO2 was steady around 1.5-2.5%. The products lost fresh mass during the storage, from 0.06% to 0.30% for PET trays and from 0.15% to 1.61% for trays covered with PVC. The appearance was considered appropriate for commercialization until the 13th day, whereas product from mangoes ripened with application of ethylene was for 11 days, presenting browning in the external surface. The naturally ripened mango presented the best flavor and consumer preference in relation to the mango ripened with application of ethylene for 11 days of storage. The control of hygienic conditions during the production and storage was good and with safety for until 10 days.
Resumo:
Purpose: To assess the effect of the composite surface conditioning on the microtensile bond strength of a resin cement to a composite used for inlay/onlay restorations. Materials and Methods: Forty-two blocks (6 × 6 × 4 mm) of a microfilled composite (Vita VMLC) were produced and divided into 3 groups (N = 14) by composite surface conditioning methods: Gr1 - etching with 37% phosphoric acid, washing, drying, silanization; Gr2 - air abrasion with 50-l̀m Al2O3 particles, silanization; Gr3 - chairside tribochemical silica coating (CoJet System), silanization. Single-Bond (one-step adhesive) was applied on the conditioned surfaces and the two resin blocks treated with the same method were cemented using RelyX ARC (dual-curing resin cement). The specimens were stored for 7 days in water at 37°C and then sectioned to produce nontrimmed beam samples, which were submitted to microtensile bond strength testing (μTBS). For statistical analysis (one-way ANOVA and Tukey's test, · = 0.05), the means of the beam samples from each luted specimen were calculated (n = 7). Results: μTBS values (MPa) of Gr2 (62.0 ± 3.9a) and Gr3 (60.5 ± 7.9a) were statistically similar to each other and higher than Gr1 (38.2 ± 8.9b). The analysis of the fractured surfaces revealed that all failures occurred at the adhesive zone. Conclusion: Conditioning methods with 50-l̀m Al2O3 or tribochemical silica coating allowed bonding between resin and composite that was statistically similar and stronger than conditioning with acid etching.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)