949 resultados para Color Doppler Sonography


Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is presented in this paper a study on the photo-electronic properties of multi layer a-Si: H/a-SiC: H p-i-n-i-p structures. This study is aimed to give an insight into the internal electrical characteristics of such a structure in thermal equilibrium, under applied Was and under different illumination condition. Taking advantage of this insight it is possible to establish a relation among-the electrical behavior of the structure the structure geometry (i.e. thickness of the light absorbing intrinsic layers and of the internal n-layer) and the composition of the layers (i.e. optical bandgap controlled through percentage of carbon dilution in the a-Si1-xCx: H layers). Showing an optical gain for low incident light power controllable by means of externally applied bias or structure composition, these structures are quite attractive for photo-sensing device applications, like color sensors and large area color image detector. An analysis based on numerical ASCA simulations is presented for describing the behavior of different configurations of the device and compared with experimental measurements (spectral response and current-voltage characteristic). (c) 2008 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A pi'n/pin a-SiC:H voltage and optical bias controlled device is presented and its behavior as image and color sensor, optical amplifier and demux device is discussed. The design and the light source properties are correlated with the sensor output characteristics. Different readout techniques are used. When a low power monochromatic scanner readout the generated carriers the transducer recognizes a color pattern projected on it acting as a direct color and image sensor. Scan speeds up to 10(4) lines per second are achieved without degradation in the resolution. If the photocurrent generated by different monochromatic pulsed channels is readout directly, the information is demultiplexed. Results show that it is possible to decode the information from three simultaneous color channels without bit errors at bit rates per channel higher than 4000 bps. Finally, when triggered by light of appropriated wavelength, it can amplify or suppress the generated photocurrent working as an optical amplifier (C) 2009 Published by Elsevier Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To study luminescence, reflectance, and color stability of dental composites and ceramics. Materials and Methods: IPS e.max, IPS Classic, Gradia, and Sinfony materials were tested, both unpolished (as-cast) and polished specimens. Coffee, tea, red wine, and distilled water (control) were used as staining drinks. Disk-shaped specimens were soaked in the staining drinks for up to 5 days. Color was measured by a colorimeter. Fluorescence was recorded using a spectrofluorometer, in the front-face geometry. Time-resolved fluorescence spectra were recorded using a laser nanosecond spectrofluorometer. Results: The exposure of the examined dental materials to staining drinks caused changes in color of the composites and ceramics, with the polished specimens exhibiting significantly lower color changes as compared to unpolished specimens. Composites exhibited lower color stability as compared to ceramic materials. Water also caused perceptible color changes in most materials. The materials tested demonstrated significantly different initial luminescence intensities. Upon exposure to staining drinks, luminescence became weaker by up to 40%, dependent on the drink and the material. Time-resolved luminescence spectra exhibited some red shift of the emission band at longer times, with the lifetimes in the range of tens of nanoseconds. Conclusions: Unpolished specimens with a more developed surface have lower color stability. Specimens stored in water develop some changes in their visual appearance. The presently proposed methods are effective in evaluating the luminescence of dental materials. Luminescence needs to be tested in addition to color, as the two characteristics are uncorrelated. It is important to further improve the color and luminescence stability of dental materials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The wide use of antibiotics in aquaculture has led to the emergence of resistant microbial species. It should be avoided/minimized by controlling the amount of drug employed in fish farming. For this purpose, the present work proposes test-strip papers aiming at the detection/semi-quantitative determination of organic drugs by visual comparison of color changes, in a similar analytical procedure to that of pH monitoring by universal pH paper. This is done by establishing suitable chemical changes upon cellulose, attributing the paper the ability to react with the organic drug and to produce a color change. Quantitative data is also enabled by taking a picture and applying a suitable mathematical treatment to the color coordinates given by the HSL system used by windows. As proof of concept, this approach was applied to oxytetracycline (OXY), one of the antibiotics frequently used in aquaculture. A bottom-up modification of paper was established, starting by the reaction of the glucose moieties on the paper with 3-triethoxysilylpropylamine (APTES). The so-formed amine layer allowed binding to a metal ion by coordination chemistry, while the metal ion reacted after with the drug to produce a colored compound. The most suitable metals to carry out such modification were selected by bulk studies, and the several stages of the paper modification were optimized to produce an intense color change against the concentration of the drug. The paper strips were applied to the analysis of spiked environmental water, allowing a quantitative determination for OXY concentrations as low as 30 ng/mL. In general, this work provided a simple, method to screen and discriminate tetracycline drugs, in aquaculture, being a promising tool for local, quick and cheap monitoring of drugs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Atherosclerotic carotid disease represents approximately 20% of the causes of ischemic stroke. Effective treatment options, such as endovascular or surgical revascularization procedures, are available. Doppler Ultrasound (DUS) is a non-invasive, inexpensive, routine exam used to evaluate the presence of internal carotid artery (ICA) stenosis. We retrospectively analysed the prevalence of severe atherosclerotic carotid disease in a population of patients with acute ischemic stroke/transitory ischemic attacks (TIAs), and the role of DUS in the detection of ICA stenosis and treatment decisions in these patients. METHODS: A total of 318 patients with ischemic stroke or TIAs was admitted to our stroke unit, and 260 patients were studied by DUS. ICA stenosis was evaluated by DUS according to peak systolic velocity. All DUS exams were performed by the same operator. ICA stenosis was further assessed in 43 patients by digital subtraction angiography (DSA) using NASCET criteria. RESULTS: Of the total 318 patients, 260 (82%) had DUS evaluation. Of the total 520 ICAs studied by DUS, degrees of ICA stenosis were: 0-29% n= 438 (84%); 30-49% n= 8 (2%); 50-69% n= 27 (5%); 70-89% n= 15 (3%); 90-99% n= 20 (4%); oclusão n= 14 (2%). Of the total 260 patients studied, 43 (16.5%) underwent DSA. Sensibility and specificity of DUS in the diagnosis of carotid stenosis over 70% were, respectively, 91% e 84%. Of the total 31 patients with significant carotid stenosis (70-99%), 23 (74%) underwent subsequent carotid revascularization procedures. DISCUSSION: DUS is an important screening test in our stroke unit, justifying its use as a routine exam for all patients with ischemic stroke/TIAs. Moreover, our results show the relevance of severe carotid disease in a population with acute ischemic stroke/TIAs (16.5%), with a total of 9% of patients being submitted to carotid revascularization procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Previous studies have shown that a ratio of early transmitral flow velocity to early diastolic velocity of the mitral annulus (E/E') of > 15, obtained by tissue Doppler imaging (TDI), correlates with left ventricular filling pressure. OBJECTIVE: The aim of our study was to assess whether E/E' provides prognostic information in patients with dilated cardiomyopathy. METHODS: We studied 33 patients with dilated cardiomyopathy and mean ejection fraction of 31%. All the patients underwent routine two-dimensional and Doppler echocardiographic examination and TDI to determine early peak velocity of the mitral annulus. Pro-B-type natriuretic peptide (pro-BNP) and peak oxygen consumption (VO2max) were also measured. Patients were divided into two groups according to the value of E/E': Group I (n = 15 patients) with E/E' > or = 15 and Group II (n = 18 patients) with E/E' < 15. Patients were followed for 12+/-4 months; new hospital admission due to heart failure, heart transplantation and death were considered as cardiac events. RESULTS: There were significant differences between the two groups in conventional two-dimensional echocardiographic measurements (dimensions and ejection fraction) and Doppler parameters (mitral inflow). With regard to mitral annular velocities obtained by TDI at two different points (septum and lateral wall), the E', A' and S' velocities differed significantly between the two groups, with lower velocities in Group I. Systolic velocity measured in the lateral portion of the mitral annulus showed the most significant difference: Group I - 4.46 cm/sec versus Group II - 7.19 cm/sec, p < 0.00001. Pro-BNP was 5622 pg/ml in Group I, and 1254 pg/ml in Group II, p = 0.004. VO2 max was significantly different between the two groups: Group I - 17.6 ml/kg/min versus Group II - 22.8 ml/kg/min, p = 0.004. During follow-up, events were more common in Group I, with 9 patients (60%) having events, while in Group II, the event rate was 11.1% (2 patients), p = 0.004. CONCLUSION: The ratio of early transmitral flow velocity to early diastolic velocity of the mitral annulus is a powerful predictor of clinical outcome. Lower velocities of mitral annulus on TDI are expected in patients with E/E' > or = 15. Systolic velocities of under 5 cm/sec measured in the lateral portion of the mitral annulus appeared to be strongly related to prognosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Num grupo de 64 doentes de uma Unidade de Cuidados Intensivos, 24 dos quais submetidos a ventilação mecânica, foi determinada a influência da modificação da volémia nas características do Doppler cardíaco, através da negativização do balanço hídrico e correspondente modificação da pressão venosa central. Com a modificação da volémia, a relação E/A do fluxo transvalvular mitral mostrou uma tendência para reduzir, o tempo de desaceleração da onda E mitral para diminuir, o tempo de relaxamento isovolumétrico para aumentar, e a veia cava inferior reduziu o seu diâmetro expiratório e aumentou o valor do colapso inspiratório. Não se observou uma correlação significativa entre os valores das variáveis estudadas e a modificação da volémia, inclusivamente entre a pressão venosa central e o balanço hídrico. A modificação da volémia em doentes críticos modifica as características de determinados parâmetros de ecocardiografia- -Doppler, mas não é possível predizer a magnitude dessa variação.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Apresenta-se um caso clínico de dissecção da aorta abdominal - tipo B - diagnosticada por eco-Doppler e tomografia axial computorizada (TC). Discute-se o interesse do eco-Doppler no diagnóstico de dissecção da aorta abdominal e na avaliação do envolvimento arterial visceral. É ainda um método útil no follow-up dos doentes com terapêutica conservadora.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: (i) To investigate whether pulsatility index (PI) and mean flow velocities (MFV) are altered in glaucoma patients. (ii) To evaluate the significance of PI in retrobulbar autoregulation capacity. METHODS: Patients with primary open-angle glaucoma (POAG; n = 49), normal tension glaucoma (NTG; n = 62) and healthy controls (n = 48) underwent colour Doppler imaging measurements of the retrobulbar vasculature. Kruskal-Wallis test was used to compare variables between the three diagnostic groups. Restricted cubic splines were used to determine nonlinearities between the resistive index (RI) and PI correlations. RESULTS: Mean flow velocities (MFV) were lower in both short posterior ciliary arteries (SCPA) and central retinal arteries (CRA) from the two glaucoma groups (p < 0.04 versus healthy controls). No differences were detected in RI or PI in any arteries of the three diagnostic groups (p > 0.08). In healthy individuals, correlations between RI and PI were linear in all arteries. In both POAG and NTG patients, CRA presented a nonlinear curve with a cutpoint at RI 0.77 (p < 0.001) and 0.61 (p = 0.03), respectively, above which the slope increased nearly five- and tenfold (POAG: 1.96 to 10.06; NTG: -0.46-4.06), respectively. A nonlinear correlation in the ophthalmic artery was only observed in NTG patients, with a cutpoint at RI 0.82 (p < 0.001), above which the slope increased from 3.47 to 14.03. CONCLUSIONS: Glaucoma patients do not present the linear relationships between RI and PI observed in healthy individuals. Their nonlinear relations may be indicative of an altered autoregulation and suggest a possible threshold RI could be determined above which autoregulatory disturbances become more relevant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Recently, the absence of spontaneous venous pulsation (SVP) has been suggested as a vascular risk factor for primary open-angle glaucoma (POAG). As the mechanism behind this phenomenon is still unknown, the authors have studied this vascular component using colour Doppler imaging (CDI). METHODS: A total of 236 patients were divided into three diagnostic groups: healthy controls (81), POAG (86) and normal tension glaucoma (NTG; 69). All subjects were submitted to CDI studies of the retrobulbar circulation, intraocular pressure measurements and assessment of SVP existence. Mann-Whitney, chi-square contingency tables and Spearman correlations were used to explore differences and correlations between variables in the diagnostic groups. RESULTS: Eighty-two percent of healthy controls had SVP (66/81), while a smaller numbers were registered in both glaucoma groups: POAG - 50% (43/86); NTG - 51% (35/69). In NTG patients, but not in POAG patients, the prevalence of the SVP phenomenon decreases with increased glaucoma damage (p = 0.04; p = 0.55, respectively). Overall glaucoma patients from both groups had lower central retinal vein (CRV) velocities than the healthy controls (p < 0.05). NTG patients with SVP had less severe visual field defects (mean defect -6.92 versus -11.1, p < 0.05), higher [correction added after online publication 21 September 2012; the word 'higher' has been inserted to replace the word 'lower'] peak systolic and mean flow velocities in the central retinal artery (p < 0.01; p < 0.05, respectively) as well as higher [correction added after online publication 21 September 2012; the word higher has been inserted to replace the word lower] maximal velocities and RI of the CRV (p < 0.02; p < 0.05, respectively). CONCLUSIONS: Glaucoma patients have a decrease in CRV velocities. SVP is less prevalent in glaucoma patients than in healthy individuals. This phenomenon apparently reflects different hemodynamic patterns in the central retinal vessels. This variable may be of particular importance in NTG patients, where it may be associated with more advanced functional damage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To determine the correlation between ocular blood flow velocities and ocular pulse amplitude (OPA) in glaucoma patients using colour Doppler imaging (CDI) waveform analysis. METHOD: A prospective, observer-masked, case-control study was performed. OPA and blood flow variables from central retinal artery and vein (CRA, CRV), nasal and temporal short posterior ciliary arteries (NPCA, TPCA) and ophthalmic artery (OA) were obtained through dynamic contour tonometry and CDI, respectively. Univariate and multiple regression analyses were performed to explore the correlations between OPA and retrobulbar CDI waveform and systemic cardiovascular parameters (blood pressure, blood pressure amplitude, mean ocular perfusion pressure and peripheral pulse). RESULTS: One hundred and ninety-two patients were included [healthy controls: 55; primary open-angle glaucoma (POAG): 74; normal-tension glaucoma (NTG): 63]. OPA was statistically different between groups (Healthy: 3.17 ± 1.2 mmHg; NTG: 2.58 ± 1.2 mmHg; POAG: 2.60 ± 1.1 mmHg; p < 0.01), but not between the glaucoma groups (p = 0.60). Multiple regression models to explain OPA variance were made for each cohort (healthy: p < 0.001, r = 0.605; NTG: p = 0.003, r = 0.372; POAG: p < 0.001, r = 0.412). OPA was independently associated with retrobulbar CDI parameters in the healthy subjects and POAG patients (healthy CRV resistance index: β = 3.37, CI: 0.16-6.59; healthy NPCA mean systolic/diastolic velocity ratio: β = 1.34, CI: 0.52-2.15; POAG TPCA mean systolic velocity: β = 0.14, CI 0.05-0.23). OPA in the NTG group was associated with diastolic blood pressure and pulse rate (β = -0.04, CI: -0.06 to -0.01; β = -0.04, CI: -0.06 to -0.001, respectively). CONCLUSIONS: Vascular-related models provide a better explanation to OPA variance in healthy individuals than in glaucoma patients. The variables that influence OPA seem to be different in healthy, POAG and NTG patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Work Project, presented as part of the requirements for the Award of a Masters Degree in Management from the NOVA – School of Business and Economics

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Enthesitis is the hallmark of spondyloarthritis and is observed in all subtypes. Namely, a wide information on spondyloarthritis abnormalities, including synovitis, bursitis, tendinitis, enthesitis and cortical bone abnormalities (erosions and enthesophytes), can be efficiently perceived by ultrasound power Doppler. Furthermore, several studies on imaging of enthesis showed that imaging techniques are better than clinical examination to detect pathology at asymptomatic enthesis. Vascularized enthesitis detected by ultrasound power Doppler appears to be a valuable diagnostic tool to confirm spondyloarthritis diagnosis. This article focuses on the validity and reliability of ultrasound enthesitis assessment in the management of spondyloarthritis patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Discrepancy between the intensity of pulmonary congestion and the grade of cardiomegaly seems to be a common finding of Chagas cardiomyopathy, in spite of significant systolic dysfunction of the left ventricle. Its mechanism has not been established. The aim of this study was to investigate pulmonary congestion and to analyze if it correlated with Doppler echocardiographic parameters in patients with Chagas dilated cardiomyopathy. METHODS: Fifty-five patients with positive serology tests for Trypanosoma cruzi and Chagas dilated cardiomyopathy were studied. Chest x-rays, Doppler echocardiogram and plasmatic brain natriuretic peptide levels were obtained in all patients. The degree of pulmonary venous vessels changes on chest x-ray was graded using a pulmonary congestion score, and then compared to Doppler echocardiographic parameters. RESULTS: Mean age was 48.5 ± 11.2 years and 29% were women. The majority (95%) of patients were in NYHA functional class I and II. Mild pulmonary congestion by chest x-ray was found in 80% of the patients. In a multivariate analysis, left ventricular ejection fraction, right ventricular TEI index and the color M-mode velocity correlated with the degree of pulmonary congestion. CONCLUSIONS: Pulmonary venous changes on chest x-rays are frequent, but usually mild in patients with Chagas dilated cardiomyopathy. The degree of pulmonary congestion correlates with Doppler echocardiographic left and right ventricular dysfunction and with color M-mode velocity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUMO: Este trabalho tentou contribuir para a caracterização da fisiopatologia da microcirculação coronária em diferentes formas de patologia com o auxílio da ecocardiografia transtorácica. Com a aplicação da ecocardiografia Doppler transtorácica foi efectuado o estudo da reserva coronária da artéria descendente anterior e com a ecocardiografia de contraste do miocárdio foram analisados parâmetros de perfusão do miocárdio como a velocidade da microcirculação coronária, o volume de sangue miocárdico e a reserva de fluxo miocárdico. Estas técnicas foram utilizadas em diferentes situações fisiopatológicas com particular interesse na hipertrofia ventricular esquerda de diferentes etiologias como a hipertensão arterial, estenose aórtica e cardiomiopatia hipertrófica. Também na diabetes mellitus tipo 2 e na doença coronária aterosclerótica, estudámos as alterações da microcirculação coronária. Com a mesma técnica de ecocardiografia de contraste do miocárdio foi analisada a perfusão do miocárdio num modelo experimental animal sujeito a uma dieta aterogénica. Além das conclusões específicas em relação a cada um dos trabalhos efectuados há a referir como conclusões gerais a sua fácil aplicabilidade e exequibilidade em âmbito clínico, a sua reprodutibilidade e precisão. Quando comparadas com técnicas consideradas de referência mostraram resultados com significativa correlação estatística. Em todos os doentes e nos grupos controle foi possível comprovar e quantificar o gradiente de perfusão transmural em repouso e durante a acção de stress vasodilatador, relevando a importância da perfusão sub-endocárdica na função do ventrículo esquerdo. O estudo da microcirculação coronária no grupo de doentes com hipertrofia ventricular esquerda revelou que no grupo com hipertensão arterial existe disfunção da microcirculação coronária ainda antes de se observar aumento de massa do ventrículo esquerdo, e que esta disfunção é diferente em função da geometria ventricular. Nos doentes com estenose aórtica foi demonstrado que além da disfunção da microcirculação coronária, explicada pelo fenómeno de hipertrofia, existe outro componente extrínseco que depois de corrigido através de cirurgia de substituição valvular, conduziu a uma parcial normalização dos valores de reserva coronária. Na cardiomiopatia hipertrófica observou-se uma grande heterogeneidade de perfusão transmural e foi documentado, em imagens de ecocardiografia de contraste do miocárdio e após análise paramétrica, a ausência de perfusão do miocárdio na região sub-endocárdica durante o stress vasodilatador de reserva coronária diminuídos em fases precoces de evolução da doença. Foi demonstrado que a reserva coronária na DM2 em fases mais avançadas estava significativamente diminuída. Descrevemos também em doentes com DM2 e sem doença coronária angiográfica a existência de disfunção da microcirculação coronária. Durante o stress vasodilatador, observámos e documentámos neste grupo de doentes, a existência de defeitos de perfusão transitórios ou de diminuição da velocidade da microcirculação coronária. No grupo de doentes com doença coronária confirmámos o interesse da avaliação da reserva coronária após intervenção percutânea na definição de prognóstico pós EAM, em termos de recuperação funcional do ventrículo esquerdo. Em doentes com BCRE e de difícil estratificação de risco, foi possível calcular o valor de reserva coronária e estratificar o risco de doença coronária. Num modelo experimental animal demonstrámos a exequibilidade da técnica de ECM, e verificámos que nessas condições experimentais, uma sobrecarga aterogénica na dieta, ao fim de 6 semanas, comprometia severamente a reserva coronária. Estes resultados foram parcialmente reversíveis quando à dieta foi adicionada uma estatina. Estas técnicas pela sua não invasibilidade, fácil acesso, repetibilidade e inocuidade perspectivam-se de grande utilidade na caracterização de doentes com disfunção da microcirculação coronária, nas diferentes áreas de diagnóstico, terapêutica e prevenção. A possibilidade de adaptar a técnica em modelos experimentais animais também nos parece poder vir a ter grande utilidade em investigação.----------------ABSTRACT: This work is intended to be a contribution to the study of coronary microcirculation applying new echocardiographic techniques as transthoracic Doppler echocardiography of coronary arteries and myocardial contrast echocardiography. Coronary flow reserve may be assessed by transthoracic Doppler echocardiography, and important functional microcirculation parameters as microcirculation flow velocity, myocardial blood volume and myocardial flow reserve may be evaluated through myocardial contrast echocardiography. Microcirculation was analysed in different pathophysiological settings. We addressed situations with increased left ventricular mass as systemic arterial hypertension, aortic stenosis and hypertrophic cardiomyopathy. Also coronary microcirculation was studied in type 2 Diabetes and in different clinical forms of atherosclerotic coronary artery disease. Specific and detailed conclusions were withdrawn from each experimental work. In the overall it was concluded that these two techniques were important tools to easily assess specific pathophysiological information about coronary microcirculation at bed side which would be difficult to get through other techniques. When compared with gold standard techniques, similar sensibility and specificity was found. Because of their better temporal and spatial resolution it was possible to analyse the importance of transmural perfusion gradients, both in basal and during vasodilatation, and their relation to ischemia, and mechanical wall kinetics, as wall thickening and motion. Coronary microcirculation dysfunction was found in systemic arterial hypertension early evolution stages, also related to different left ventricular geometric patterns. Different etiopathogenical explanations for aortic stenosis coronary microcirculation dysfunction were analysed and compared after aortic valve replacement. Transmural myocardial perfusion heterogeneity pattern was observed in hypertrophic cardiomyopathy which was aggravated during adenosine challenge. Coronary microcirculation dysfunction was diagnosed in type 2 diabetes both with coronary artery disease and with normal angiographic coronary arteries. Dynamic transitory subendocardial perfusion defects with adenosine vasodilatation were visualized in these patients.In patients with left branch block, transthoracic Doppler echocardiography was able to suggest a coronary reserve cut-off value for risk stratification. Also it was possible with this technique to calculate coronary flow reserve and predict restenosis after PTCA Again, in an experimental animal model, applying myocardial contrast echocardiography technique it was possible to study the consequences of an atherogenic diet and statins action on the coronary microcirculation function. Because these techniques are easily performed at bed side, are harmless, use no ionizing radiation and because of their repeatability, reproducibility and accuracythey are promissory tools to assess coronary microcirculation. Both in clinic and research areas these techniques will probably have a role in clinical diagnosis, prevention and therapeutically decision.