972 resultados para Carrying Loads


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The overall goal of this assessment was to evaluate the effects of nutrient-source reductions that may be implemented in the Mississippi River Basin (MRB) to reduce the problem of low oxygen conditions (hypoxia) in the nearshore Gulf of Mexico. Such source reductions would affect the quality of surface waters—streams, rivers, and reservoirs—in the drainage basin itself, as well as nearshore Gulf waters. The task group’s work was divided into addressing the effects of nutrient-source reductions on: (1) surface waters in the MRB and (2) hypoxia in the Gulf of Mexico.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

When two rough surfaces are loaded together it is well known that the area of true contact is very much smaller then the geometric area and that, consequently, local contact pressures are very much greater than the nominal value. If the asperities on each surface can be thought of as possessing smooth summits and each of the solids is elastically isotropic then the pressure distribution will consist of a series of small, but severe, Hertzian patches. However, if one of both of the surfaces in question is protected by a boundary layer then both the number and dimensions of these patches, and the form of the pressure distribution within them, will be modified. Recent experimental evidence from studies using both Atomic Force Microscopy and micro-tribometry suggests that boundary films produced by the action of commercial anti-wear additives, such as ZDTP, exhibit mechanical properties, which are affected by local values of pressure. These changes bring about further modifications to local conditions. These effects have been explored in a numerical model of rough surface contact and the implications for the mechanisms of surface distress and wear are discussed. © 2000 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In concentrated contacts the behaviour of lubricants is much modified by the high local pressures: changes can arise both from molecular ordering within the very thin film lubricant layers present at the interface as well as from the deposition on the component surfaces of more solid-like polymeric boundary layers. These 'third bodies' separating the solid surfaces may have rheological or mechanical properties very different from those observed in the bulk. Classical elasto-hydrodynamic theory considers the entrapped lubricant to exhibit a piezo-viscous behaviour while the conventional picture of more solid boundary lubricant layers views their shear strength r as being linearly dependent on local pressure p, so that T = TO + ap where TO and a are constants. If TO is relatively small, then the coefficient of friction \i = T Ip ~ a and so Amonton's laws are recovered. However, the properties of adsorbed or deposited surface films, or indeed other third bodies such as debris layers, may be more complex than this. A preliminary study has looked quantitatively at the influence of the pressure dependence of the shear strength of any surface layer on the overall friction coefficient of a contact which is made up of an array of asperities whose height varies in a Gaussian manner. Individual contact points may be elastic or plastic. The analysis results in plots of coefficient of friction versus the service or load parameter PIH&NRa where P is the nominal pressure on the contact, HS the hardness of the deforming surface, N the asperity density, R the mean radius of curvature of the asperities, and a is the standard deviation of their height distribution. In principle, any variation oft withp can be incorporated into the model; however, in this initial study we have used data on colloidal suspensions from the group at the Ecole Centrale de Lyon as well as examining the effect of functional relationships of somewhat greater complexity than a simple linear form. Results of the analysis indicate that variations in fj. are possible as the load is varied which depend on the statistical spread of behaviour at individual asperity contacts. The value of this analysis is that it attempts to combine the behaviour of films on the molecular scale with the topography of real engineering surfaces and so give an indication of the effects at the full-size or macro-scale that can be achieved by chemical or molecular surface engineering.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Many piled foundations have been destroyed under significant cyclic loads in earthquakes. Centrifuge modelling of a single pile subjected to cyclic loads has been conducted to investigate the influence of cyclic loads on the axial performance of the single pile. Different pile installation procedures were applied to compare the axial behaviour of different piles under cyclic loads. Pile head permanent settlements accumulated due to cyclic axial loads, and these increased with the increasing load amplitude. Also the pile head axial secant stiffness decreased with the increasing number of axial load cycles, and with increasing amplitude. Furthermore, the axial pile performance is influenced significantly by different installation methods. © 2010 ASCE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The goal of this work was to investigate stability in relation to the magnitude and direction of forces applied by the hand. The endpoint stiffness and joint stiffness of the arm were measured during a postural task in which subjects exerted up to 30% maximum voluntary force in each of four directions while controlling the position of the hand. All four coefficients of the joint stiffness matrix were found to vary linearly with both elbow and shoulder torque. This contrasts with the results of a previous study, which employed a force control task and concluded that the joint stiffness coefficients varied linearly with either shoulder or elbow torque but not both. Joint stiffness was transformed into endpoint stiffness to compare the effect on stability as endpoint force increased. When the joint stiffness coefficients were modeled as varying with the net torque at only one joint, as in the previous study, we found that hand position became unstable if endpoint force exceeded about 22 N in a specific direction. This did not occur when the joint stiffness coefficients were modeled as varying with the net torque at both joints, as in the present study. Rather, hand position became increasingly more stable as endpoint force increased for all directions of applied force. Our analysis suggests that co-contraction of biarticular muscles was primarily responsible for the increased stability. This clearly demonstrates how the central nervous system can selectively adapt the impedance of the arm in a specific direction to stabilize hand position when the force applied by the hand has a destabilizing effect in that direction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Building integrated photovoltaics (BIPV) has the potential to become a major source of renewable energy in the urban environment. BIPV has significant influence on the heat transfer through the building envelope because of the change of the thermal resistance by adding or replacing the building elements. Four different roofs are used to assess the impacts of BIPV on the building's heating-and-cooling loads; namely ventilated air-gap BIPV, non-ventilated (closed) air-gap BIPV, closeroof mounted BIPV, and the conventional roof with no PV and no air gap. One-dimensional transient models of four cases are derived to evaluate the PV performances and building cooling-and-heating loads across the different roofs in order to select the appropriate PV building integration method in Tianjin, China. The simulation results show that the PV roof with ventilated air-gap is suitable for the application in summer because this integration leads to the low cooling load and high PV conversion efficiency. The PV roof with ventilation air-gap has a high time lag and small decrement factor in comparison with other three roofs and has the same heat gain as the cool roof of absorptance 0.4. In winter, BIPV of non-ventilated air gap is more appropriate due to the combination of the low heating-load through the PV roof and high PV electrical output. © 2005 Elsevier Ltd. All rights reserved.