955 resultados para Calculation of citation metric
Resumo:
A plan to construct a canal through the Kra Isthmus in Southern Thailand has been proposed many times since the 17th century. The proposed canal would become an alternative route to the over-crowded Straits of Malacca. In this paper, we attempt to utilize a Geographical Information System (GIS) to calculate the realistic distances between ports that would be affected by the Kra Canal and to estimate the economic impact of the canal using a simulation model based on spatial economics. We find that China, India, Japan, and Europe gain the most from the construction of the canal, besides Thailand. On the other hand, the routes through the Straits of Malacca are largely beneficial to Malaysia, Brunei, and Indonesia, besides Singapore. Thus, it is beneficial for all ASEAN member countries that the Kra Canal and the Straits of Malacca coexist and complement one another.
Resumo:
The accurate computation of radioactive opacities is needed in several research fields such as astrophysics, magnetic fusion or ICF target physics analysis, in which the radiation transport is an important feature to determine in detail. Radiation transport plays an important role in the transport of energy in dense plasma and it is strongly influenced by the variation of plasma opacity with density and temperature, as well as, photon energy. In this work we present some new features of the opacity code ATMED [1]. This code has been designed to compute the spectral radioactive opacity as well as the Rosseland and Planck means for single element and mixture plasmas. The model presented is fast, stable and reasonably accurate into its range of application and it can be a useful tool to simulate ICF experiments in plasma laboratory.
Resumo:
This paper presents some of the results of a method to determine the main reliability functions of concentrator solar cells. High concentrator GaAs single junction solar cells have been tested in an Accelerated Life Test. The method can be directly applied to multi-junction solar cells. The main conclusions of this test carried out show that these solar cells are robust devices with a very low probability of failure caused by degradation during their operation life (more than 30 years). The evaluation of the probability operation function (i.e. the reliability function R(t)) is obtained for two nominal operation conditions of these cells, namely simulated concentration ratios of 700 and 1050 suns. Preliminary determination of the Mean Time to Failure indicates a value much higher than the intended operation life time of the concentrator cells.
Resumo:
A novel formulation for the surface impedance characterization is introduced for the canonical problem of surface fields on a perfect electric conductor (PEC) circular cylinder with a dielectric coating due to a electric current source using the Uniform Theory of Diffraction (UTD) with an Impedance Boundary Condition (IBC). The approach is based on a TE/TM assumption of the surface fields from the original problem. Where this surface impedance fails, an optimization is performed to minimize the error in the SD Green?s function between the original problem and the equivalent one with the IBC. This asymptotic method, accurate for large separations between source and observer points, in combination with spectral domain (SD) Green?s functions for multidielectric coatings leads to a new hybrid SD-UTD with IBC to calculate mutual coupling among microstrip patches on a multilayer dielectric-coated PEC circular cylinder. Results are compared with the eigenfunction solution in SD, where a very good agreement is met.
Resumo:
This study develops a proposal of method of calculation useful to estimate the energy produced by a PV grid-connected system making use of irradiance-domain integrals and denition of statistical moment. Validation against database of real PV plants performance data shows that acceptable energy estimation can be obtained with rst to fourth statistical moments and some basic system parameters. This way, only simple calculations at the reach of pocket calculators, are enough to estimate AC energy.
Resumo:
Recently, a theoretical criterion to calculate the stability of an axial-flow compressor rotor has been presented in the scientific literature. This theoretical criterion was used for determining the locus of the stability line over the rotor map and for predicting the post-stall evolution of the constant-speed line of a rotor. The main objective of this paper is to improve the predictions of such a model. To do that, the paper proposes a different characterization of the characteristic azimuthal length and a calculation of the ratio of specific heats based on a polytropic exponent. Thanks to these new values, the model predicts two bifurcation points in the behaviour of the flow: the inception point of the instability and the surge point. Experimental data from a pure axial compressor are used to validate the model showing that the prediction of the flow coefficient at the surge point has an error inferior to 5%. For the rotor studied, the paper provides a quantitative and qualitative description of the inception of the instability and of the mechanism involved in the instable region of the compressor map. The paper also discusses the role of rotor efficiency in the position of the bifurcations and gives a sensitivity analysis of its position. Finally, it presents a discussion about how the model can explain the different behaviours exhibited by the same rotor when the flow coefficient is reduced
Resumo:
The idea that a building and consequently its structure is for a lifetime has stopped being a reference. CTE establishes that the life utility of a normal construction structure should be of 50years. If the time variable is introduced in the calculation of actions on structures, seems evident thatdifferent values can be used for a standard building, for a provisional structure with ≤ 10 years of life utility or for a monumental building with a life utility of 100 years. The present presentation follows at all moment, the directives and formulations given in the different structural Eurocodes, till the moment not included in the CTE. Finally the values of the actions that must be used to extend the life utility of a building until. 100 years will be deduced, also it suitability and e conomic feasibility will be discuss.