1000 resultados para CGAR-EM (cromatografia gasosa de alta resolução - espectrometria de massas)
Resumo:
Valproic acid (VA) is a drug used to control seizures in several epileptic conditions. In VA pharmacotherapy, therapeutic drug monitoring is recommended to obtain adequate seizure control and avoid toxicity. The aim of this study was to validate a method for the determination of valproic acid in serum, employing high performance liquid chromatography with diode array detection (HPLC-DAD), after derivatization with phenacyl bromide. The calibration curve (y=0.0133x-0.0025) presented good linearity with r²=0.9999. Accuracy (101-115%), intra-assay precision (4.53-8.15%) and inter-assay precision (3.15-6.77%) were acceptable. The quantification limit was 2.0 µg/mL. The method presented similar results to enzyme immunoassay.
Resumo:
This article describes an experiment designed to teach quantitative determination in gas chromatography (GC) in Organic and Analytical Chemistry practical classes. The experiment consisted of extracting and analyzing eugenol from clove seeds to perform a quantitative approach aimed at comparing results obtained by external and internal calibration procedures. Therefore, this experiment proved to be very effective tool to enhance students awareness on the need to understand different types of calibration in GC and on how to avoid common experimental errors, and to find the best ways to eliminate their interference during the quantitative analysis phase.
Resumo:
The evaluation of uncertainty associated with an analytic result is an essential part of the measurement process. Recently, several approaches to evaluate the uncertainty in measurement have been developed. Here, the gas chromatography assay uncertainty for natural gas is compared by some of these approaches: the guide to the expression of uncertainty in measurement (GUM) approach, top-down approach (reproducibility estimate from an inter-laboratory study), Barwick & Ellison (data from validation), study of variability and fuzzy approach. The comparison shows that GUM, Barwick & Ellison and fuzzy approaches lead to comparable uncertainty evaluations, which does not happen with the top-down approach and study of variability by the absence of data normality.
Resumo:
A method using ultrasonication extraction for the determination of 17 polycyclic aromatic hydrocarbons (PAHs), selected by the USEPA and NIOSH as "consent decree" priority pollutants, in soil by High Performance Liquid Chromatography (HPLC) was studied. Separation and detection were completed in 20 min with a C18 columm, acetonitrile-water gradient elution and ultraviolet absorption and fluorescence detections. The detection limits, for a 10 µL of solution injection, were less than 9,917 ng/g in UV detection and less than 1,866 ng/g in fluorescence detection. Several organic solvents were tested for extraction of the 17 PAHs from soils. Acetone was the best solvent among the three solvents tested, and the order of the extraction efficiencies was: acetone>methanol>acetonitrile. Ultrasonication using acetone as solvent extraction was used to evaluate the biodegradation of those compounds in contaminated soil during a vermicomposting process.
Resumo:
The aim of this study was to validate a method for the determination of acethaldehyde, methanol, ethanol, acetone and isopropanol employing solid-phase microextraction associated to gas chromatography with flame ionization detection. The operational conditions of SPME were optimized by response surface analysis. The calibration curves for all compounds were linear with r² > 0.9973. Accuracy (89.1-109.0%), intra-assay precision (1.8-8.5%) and inter-assay precision (2.2-8.2%) were acceptable. The quantification limit was 50 µg/mL. The method was applied to the meaurement of ethanol in blood and oral fluid of a group of volunteers. Oral fluid ethanol concentrations were not directly correlated with blood concentrations.
Resumo:
The validation of analytical methods is an important step in quality control. The main objective of this study is to propose an HPLC experiment to verify the parameters of validation of chromatographic methods, based on green chemistry principles, which can be used in experimental courses of chemistry and related areas.
Resumo:
In this work a new experiment using HPLC is proposed in order to explore the role of acidity and the organic modifiers in the determination of methylxanthines in tea and coffee. Multivariate and univariate optimizations of the experimental conditions were used.
Resumo:
The presence of chloramphenicol residues in goat milk can cause toxic effects in the population. The present work consists of the optimization and validation of analytical methodology for determination of chloramphenicol residues in goat milk by GC/ECD. The extraction was made with ethyl acetate and the clean-up with SPE-C18. The identification was made by comparison of retention time and GC/MS, and the quantification by external standard. The method was selective, linearity (0.998), precise (5.8-13.4%), exact (69.87-73.71%) and robust. The LOD and LOQ of method were 0.030 and 0.10 μg/kg, respectively. The method was efficiently for analysis of chloramphenicol in goat milk.
Resumo:
Different phenolic compound, 5- caffeoylquinic acid (5-CQA), caffeic acid (AC) and rutin (Ru) contents of yerba-mate (Ilex paraguariensis) Brazilian samples of 06 different regions of São Mateus - Paraná, during natural and accelerated industrial storage, were evaluated. For quantification, a reverse phase HPLC isocratic method was developed and validated using methanol:water (35:65 v/v) acidified with 0.5% acetic acid as mobile phase and a photodiode array detector. The six sample global average contents were (34.90 and 36.10 mg g-1) for 5-CQA, (0.18 mg g-1 and 0.23 mg g-1) for AC and (7.12 and 7.18 mg g-1) for Ru, respectively, for the natural and accelerated storage systems. The results showed that the 5-CQA and Ru content are kept constant during the storage while AC content increase only during accelerated storage.
Resumo:
An analytical method has been developed and validated for the determination of an association of ampicillins in a lyophilized powder for injection by HPLC. The advantage of chromatographic method other than the microbiological one is that, it is possible to monitor precisely, out-of-specification results in quality control processes and also during stability studies, in which an association of ampicillins is present. The proposed HPLC method was developed by using forced degraded samples, in order to reach a selective analysis of ampicillins when in the presence of their degradation products. It was possible to detect benzatine and through indirect calculation, to determine the ampicillin sodium in the drug sample. The method showed to be selective, accurate, precise, robust and linear (from 45.92 to 36.04 μg mL-1 of total ampicillin and from 14.53 to 43.28 μg mL-1 of benzatine). The accuracy determined from recovery test, gave results in the range of 99.41% of total ampicillin to 100.31% of benzatine. Hence, it can be concluded that the proposed HPLC method is applicable for ampicillins determination.
Resumo:
The development of analytical methods for determination of eight pesticides of different chemical classes (trichlorfon, propanil, fipronil, propiconazole, trifloxystrobin, permethrin, difenoconazole and azoxystrobin) in sediments with gas chromatography-micro-electron capture detector (GC/µECD) and comprehensive two-dimensional gas chromatography with micro-electron capture detector (GCxGC/µECD) is described. These methods were applied to real sediment samples, and the best results were obtained using a 5% diphenyl-methylpolysiloxane column for 1D-GC. For GCxGC the same column was employed in the first dimension and a 50%-phenyl-methylpolysiloxane stationary phase was placed in the second dimension. Due to the superior peak capacity and selectivity of GCxGC, interfering matrix peaks were separated from analytes, showing a better performance of GCxGC.
Resumo:
A method for ester content determination in soybean methyl biodiesel was studied, using ethyl oleate as internal standard. A biodiesel sample was analyzed and had its purity estimated as 92.8%. Method accuracy was evaluated by comparison with the result obtained via EN14103, with a relative difference of 0.1%. Repetitivity and intermediate precision were estimated as 2 and 1.5%, respectively.
Resumo:
The organic acids (tartaric, malic, citric, lactic and succinic) are de main components responsible for the acidity in the wine. This method for simultaneous determination of organic acids and interfering peaks in wines can be achieved in 16 min. The sample preceded by a dilution and filtration step. The chromatographic separation required one reversed phase column, isocratic mobile phase (acetonitrila, formic acid in water) and detection wavelength was set at 212 nm. The validation confirmed good repeatability, recovery and application in red and white wines.
Resumo:
This review first discusses the limitations of many of the supports and stationary phases used in reversed phase high performance liquid chromatography and then describes those, developed more recently, that present better stabilities and more versatile selectivities. Emphases will be given to stationary phases that use higher purity silicas, hybrid silicas, monolithic silicas, metallic oxides and mixed oxides as supports and those that have embedded polar groups or contain phenyl or fluoro groups as the stationary phase as well as the phases used for mixed mode or hydrophilic interaction separations. These modern stationary phases facilitate the analysis of complex mixtures.
Resumo:
A method to quantify lycopene and β-carotene in freeze dried tomato pulp by high performance liquid chromatography (HLPC) was validated according to the criteria of selectivity, sensitivity, precision and accuracy, and uncertainty estimation of measurement was determined with data obtained in the validation. The validated method presented is selective in terms of analysis, and it had a good precision and accuracy. Detection limit for lycopene and β-carotene was 4.2 and 0.23 mg 100 g-1, respectively. The estimation of expanded uncertainty (K = 2) for lycopene was 104 ± 21 mg 100 g-1 and for β-carotene was 6.4 ± 1.5 mg 100 g-1.