602 resultados para Bullet embolism
Resumo:
RATIONALE AND OBJECTIVES: Polyethylene glycol-coated liposomal blood pool contrast agents maintain contrast enhancement over several hours. This study aimed to evaluate (long-term) imaging of pulmonary arteries, comparing conventional iodinated contrast with a liposomal blood pool contrast agent. Also, visualization of the (real-time) therapeutic effects of tissue plasminogen activator (t-PA) on pulmonary embolism (PE) was attempted. MATERIALS AND METHODS: Six rabbits (weight approximately 4 kg) had autologous blood clots injected through the superior vena cava. Imaging was performed using conventional contrast (iohexol, 350 mg I/ml; GE HealthCare, Princeton, NJ) at a dose of 1400 mg I per animal, and after wash-out, animals were imaged using an iodinated liposomal blood pool agent (88 mg I/mL, dose 900 mg I/animal). Subsequently, five animals were injected with 2 mg of t-PA and imaging continued for up to 4(1/2) hours. RESULTS: Both contrast agents identified PE in the pulmonary trunk and main pulmonary arteries in all rabbits. Liposomal blood pool agent yielded uniform enhancement, which remained relatively constant throughout the experiments. Conventional agents exhibited nonuniform opacification and rapid clearance postinjection. Three of six rabbits had mistimed bolus injections, requiring repeat injections. Following t-PA, pulmonary embolus volume (central to segmental) decreased in four of five treated rabbits (range 10-57%, mean 42%). One animal showed no response to t-PA. CONCLUSIONS: Liposomal blood pool agents effectively identified acute PE without need for reinjection. PE resolution following t-PA was quantifiable over several hours. Blood pool agents offer the potential for repeated imaging procedures without need for repeated (nephrotoxic) contrast injections.
Resumo:
Vesicular stomatitis virus (VSV) is a bullet-shaped rhabdovirus and a model system of negative-strand RNA viruses. Through direct visualization by means of cryo-electron microscopy, we show that each virion contains two nested, left-handed helices: an outer helix of matrix protein M and an inner helix of nucleoprotein N and RNA. M has a hub domain with four contact sites that link to neighboring M and N subunits, providing rigidity by clamping adjacent turns of the nucleocapsid. Side-by-side interactions between neighboring N subunits are critical for the nucleocapsid to form a bullet shape, and structure-based mutagenesis results support this description. Together, our data suggest a mechanism of VSV assembly in which the nucleocapsid spirals from the tip to become the helical trunk, both subsequently framed and rigidified by the M layer.
Resumo:
AIMS No standardized local thrombolysis regimen exists for the treatment of pulmonary embolism (PE). We retrospectively investigated efficacy and safety of fixed low-dose ultrasound-assisted catheter-directed thrombolysis (USAT) for intermediate- and high-risk PE. METHODS AND RESULTS Fifty-two patients (65 ± 14 years) of whom 14 had high-risk PE (troponin positive in all) and 38 intermediate-risk PE (troponin positive in 91%) were treated with intravenous unfractionated heparin and USAT using 10 mg of recombinant tissue plasminogen activator per device over the course of 15 h. Bilateral USAT was performed in 83% of patients. During 3-month follow-up, two [3.8%; 95% confidence interval (CI) 0.5-13%] patients died (one from cardiogenic shock and one from recurrent PE). Major non-fatal bleeding occurred in two (3.8%; 95% CI, 0.5-13%) patients: one intrathoracic bleeding after cardiopulmonary resuscitation requiring transfusion, one intrapulmonary bleeding requiring lobectomy. Mean pulmonary artery pressure decreased from 37 ± 9 mmHg at baseline to 25 ± 8 mmHg at 15 h (P < 0.001) and cardiac index increased from 2.0 ± 0.7 to 2.7 ± 0.9 L/min/m(2) (P < 0.001). Echocardiographic right-to-left ventricular end-diastolic dimension ratio decreased from 1.42 ± 0.21 at baseline to 1.06 ± 0.23 at 24 h (n = 21; P < 0.001). The greatest haemodynamic benefit from USAT was found in patients with high-risk PE and in those with symptom duration < 14 days. CONCLUSION A standardized catheter intervention approach using fixed low-dose USAT for the treatment of intermediate- and high-risk PE was associated with rapid improvement in haemodynamic parameters and low rates of bleeding complications and mortality.
Resumo:
BACKGROUND In patients with acute pulmonary embolism, systemic thrombolysis improves right ventricular (RV) dilatation, is associated with major bleeding, and is withheld in many patients at risk. This multicenter randomized, controlled trial investigated whether ultrasound-assisted catheter-directed thrombolysis (USAT) is superior to anticoagulation alone in the reversal of RV dilatation in intermediate-risk patients. METHODS AND RESULTS Fifty-nine patients (63±14 years) with acute main or lower lobe pulmonary embolism and echocardiographic RV to left ventricular dimension (RV/LV) ratio ≥1.0 were randomized to receive unfractionated heparin and an USAT regimen of 10 to 20 mg recombinant tissue plasminogen activator over 15 hours (n=30; USAT group) or unfractionated heparin alone (n=29; heparin group). Primary outcome was the difference in the RV/LV ratio from baseline to 24 hours. Safety outcomes included death, major and minor bleeding, and recurrent venous thromboembolism at 90 days. In the USAT group, the mean RV/LV ratio was reduced from 1.28±0.19 at baseline to 0.99±0.17 at 24 hours (P<0.001); in the heparin group, mean RV/LV ratios were 1.20±0.14 and 1.17±0.20, respectively (P=0.31). The mean decrease in RV/LV ratio from baseline to 24 hours was 0.30±0.20 versus 0.03±0.16 (P<0.001), respectively. At 90 days, there was 1 death (in the heparin group), no major bleeding, 4 minor bleeding episodes (3 in the USAT group and 1 in the heparin group; P=0.61), and no recurrent venous thromboembolism. CONCLUSIONS In patients with pulmonary embolism at intermediate risk, a standardized USAT regimen was superior to anticoagulation with heparin alone in reversing RV dilatation at 24 hours, without an increase in bleeding complications. CLINICAL TRIAL REGISTRATION URL http://www.clinicaltrials.gov. Unique identifier: NCT01166997.
Resumo:
Pulmonary embolism remains a common and potentially life-threatening disease. For patients with intermediate- and high-risk pulmonary embolism, catheter-based revascularization therapy has emerged as potential alternative to systemic thrombolysis or surgical embolectomy. Ultrasound-assisted catheter-directed thrombolysis is a contemporary catheter-based technique and is the focus of the present review. Ultrasound-assisted catheter-directed thrombolysis is more effective in reversing right ventricular dysfunction and dilatation in comparison with anticoagulation alone in patients at intermediate risk. However, a direct comparison of ultrasound-assisted thrombolysis with systemic thrombolysis or surgical thrombectomy is not available. Ultrasound-assisted thrombolysis with initial intrapulmonary thrombolytic bolus may also be effective in high-risk patients, but evidence from randomized trials is not available. This review summarizes current data on ultrasound-assisted thrombolysis for acute pulmonary embolism.
Resumo:
Tetralogy of Fallot (TOF) is one of the most common congenital heart malformations comprising a ventricular septal defect, right ventricular outflow tract obstruction, right ventricular hypertrophy, and overriding aorta. A rare variant includes pulmonary atresia and major aortopulmonary collateral arteries. Altered hemodynamics within the functional single-ventricle results in turbulent flow and predisposes to endocardial vegetation formation which may consequently lead to thromboembolic events. We present a rare case of an adult survivor of uncorrected TOF with pulmonary atresia.
Resumo:
Administration of cross-sex hormones to male-to-female transsexual subjects, usually oestrogens + often anti-androgens, such as cyproterone acetate, carries a risk of venous thromboembolism (VTE). VTE usually occurs in the first year of oestrogen administration. Ethinyl oestradiol, due to its chemical structure, was in 2003 identified as a major factor in the occurrence of VTE. Most clinics do not prescribe ethinyl oestradiol any longer, but people who take hormones without medical supervision use often oral contraceptives containing ethinyl oestradiol, many times in overdose. Cessation of use of ethinyl oestradiol and peri-operative thrombosis prophylaxis for surgery have reduced prevalence rate of VTE. Other oral oestrogens should not be overdosed, and transdermal oestrogen is to be preferred. Thrombosis prophylaxis for surgery is mandatory. It seems advisable to stop hormone use at least 2 weeks before major surgery, to be resumed only after 3 weeks following full mobilisation.
Resumo:
BACKGROUND The role of fibrinolytic therapy in patients with intermediate-risk pulmonary embolism is controversial. METHODS In a randomized, double-blind trial, we compared tenecteplase plus heparin with placebo plus heparin in normotensive patients with intermediate-risk pulmonary embolism. Eligible patients had right ventricular dysfunction on echocardiography or computed tomography, as well as myocardial injury as indicated by a positive test for cardiac troponin I or troponin T. The primary outcome was death or hemodynamic decompensation (or collapse) within 7 days after randomization. The main safety outcomes were major extracranial bleeding and ischemic or hemorrhagic stroke within 7 days after randomization. RESULTS Of 1006 patients who underwent randomization, 1005 were included in the intention-to-treat analysis. Death or hemodynamic decompensation occurred in 13 of 506 patients (2.6%) in the tenecteplase group as compared with 28 of 499 (5.6%) in the placebo group (odds ratio, 0.44; 95% confidence interval, 0.23 to 0.87; P=0.02). Between randomization and day 7, a total of 6 patients (1.2%) in the tenecteplase group and 9 (1.8%) in the placebo group died (P=0.42). Extracranial bleeding occurred in 32 patients (6.3%) in the tenecteplase group and 6 patients (1.2%) in the placebo group (P<0.001). Stroke occurred in 12 patients (2.4%) in the tenecteplase group and was hemorrhagic in 10 patients; 1 patient (0.2%) in the placebo group had a stroke, which was hemorrhagic (P=0.003). By day 30, a total of 12 patients (2.4%) in the tenecteplase group and 16 patients (3.2%) in the placebo group had died (P=0.42). CONCLUSIONS In patients with intermediate-risk pulmonary embolism, fibrinolytic therapy prevented hemodynamic decompensation but increased the risk of major hemorrhage and stroke. (Funded by the Programme Hospitalier de Recherche Clinique in France and others; PEITHO EudraCT number, 2006-005328-18; ClinicalTrials.gov number, NCT00639743.).
Resumo:
BACKGROUND Up to 40% of ischaemic strokes are cryptogenic. A strong association between cryptogenic stroke and the prevalence of patent foramen ovale (PFO) suggests paradoxical embolism via PFO as a potential cause. Randomized trials failed to demonstrate superiority of PFO closure over medical therapy. METHODS AND RESULTS Randomized trials comparing percutaneous PFO closure against medical therapy or devices head-to-head published or presented by March 2013 were identified through a systematic search. We performed a network meta-analysis to determine the effectiveness and safety of PFO closure with different devices when compared with medical therapy. We included four randomized trials (2963 patients with 9309 patient-years). Investigated devices were Amplatzer (AMP), STARFlex (STF), and HELEX (HLX). Patients allocated to PFO closure with AMP were less likely to experience a stroke than patients allocated to medical therapy [rate ratio (RR) 0.39; 95% CI: 0.17-0.84]. No significant differences were found for STF (RR 1.01; 95% CI: 0.44-2.41), and HLX (RR, 0.71; 95% CI: 0.17-2.78) when compared with medical therapy. The probability to be best in preventing strokes was 77.1% for AMP, 20.9% for HLX, 1.7% for STF, and 0.4% for medical therapy. No significant differences were found for transient ischaemic attack and death. The risk of new-onset atrial fibrillation was more pronounced for STF (RR 7.67; 95% CI: 3.25-19.63), than AMP (RR 2.14; 95% CI: 1.00-4.62) and HLX (RR 1.33; 95%-CI 0.33-4.50), when compared with medical therapy. CONCLUSIONS The effectiveness of PFO closure depends on the device used. PFO closure with AMP appears superior to medical therapy in preventing strokes in patients with cryptogenic embolism.
Resumo:
Systemic embolism is a classic complication of infective endocarditis. Coronary involvement and acute myocardial infarction (MI) are rare and increase mortality significantly. Recognising this unusual entity is crucial to provide adequate care. Percutaneous coronary intervention and thrombus aspiration is preferred to thrombolysis, which classically increases intracerebral hemorrhage risk. The present article describes the case of an acute inferior ST-elevated MI due to a Streptococcus salivarius endocarditis in a patient with known bicuspid aortic valve.
Resumo:
In modern medico-legal literature, only a small number of publications deal with fatal injuries from black powder guns. Most of them focus on the morphological features such as intense soot soiling, blast tattooing and burn effects in close-range shots or describe the wound ballistics of spherical lead bullets. Another kind of "unusual" and potentially lethal weapons are handguns destined for firing only blank cartridges such as starter and alarm pistols. The dangerousness of these guns is restricted to very close and contact range shots and results from the gas jet produced by the deflagration of the propellant. The present paper reports on a suicide committed with a muzzle-loading percussion pistol cal. 45. An unusually large stellate entrance wound was located in the precordial region, accompanied by an imprint mark from the ramrod and a faint greenish discoloration (apparently due to the formation of sulfhemoglobin). Autopsy revealed an oversized powder cavity, multiple fractures of the anterior thoracic wall as well as ruptures of the heart, the aorta, the left hepatic lobe and the diaphragm. In total, the zone of mechanical destruction had a diameter of approx. 15 cm. As there was no exit wound and no bullet lodged in the body, the injury was caused exclusively by the inrushing combustion gases of the propellant (black powder) comparable with the gas jet of a blank cartridge gun. In contact shots to ballistic gelatine using the suicide's pistol loaded with black powder but no projectile, the formation of a nearly spherical cavity could be demonstrated by means of a high-speed camera. The extent of the temporary cavity after firing with 5 g of black powder roughly corresponded to the zone of destruction found in the suicide's body.
Resumo:
Paradoxical embolism is an important clinical entity among patients with venous thromboembolism in the presence of intracardiac or pulmonary shunts. The clinical presentation is diverse and potentially life-threatening. Although the serious nature and complications of paradoxical embolism are recognized, the disease entity is still rarely considered and remains under-reported. This paper provides an overview on the different clinical manifestations of paradoxical embolism, describes the diagnostic tools for the detection of intracardiac and pulmonary shunts, reviews therapeutic options, and summarizes guideline recommendations for the secondary prevention of paradoxical embolism.
Resumo:
OBJECTIVE To determine the prognostic accuracy of cardiac biomarkers alone and in combination with clinical scores in elderly patients with non-high-risk pulmonary embolism (PE). DESIGN Ancillary analysis of a Swiss multicentre prospective cohort study. SUBJECTS A total of 230 patients aged ≥65 years with non-high-risk PE. MAIN OUTCOME MEASURES The study end-point was a composite of PE-related complications, defined as PE-related death, recurrent venous thromboembolism or major bleeding during a follow-up of 30 days. The prognostic accuracy of the Pulmonary Embolism Severity Index (PESI), the Geneva Prognostic Score (GPS), the precursor of brain natriuretic peptide (NT-proBNP) and high-sensitivity cardiac troponin T (hs-cTnT) was determined using sensitivity, specificity, predictive values, receiver operating characteristic (ROC) curve analysis, logistic regression and reclassification statistics. RESULTS The overall complication rate during follow-up was 8.7%. hs-cTnT achieved the highest prognostic accuracy [area under the ROC curve: 0.75, 95% confidence interval (CI): 0.63-0.86, P < 0.001). At the predefined cut-off values, the negative predictive values of the biomarkers were above 95%. For levels above the cut-off, the risk of complications increased fivefold for hs-cTnT [odds ratio (OR): 5.22, 95% CI: 1.49-18.25] and 14-fold for NT-proBNP (OR: 14.21, 95% CI: 1.73-116.93) after adjustment for both clinical scores and renal function. Reclassification statistics indicated that adding hs-cTnT to the GPS or the PESI significantly improved the prognostic accuracy of both clinical scores. CONCLUSION In elderly patients with nonmassive PE, NT-proBNP or hs-cTnT could be an adequate alternative to clinical scores for identifying low-risk individuals suitable for outpatient management.