880 resultados para Bone Density


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The World Health Organization (WHO) criteria for the diagnosis of osteoporosis are mainly applicable for dual X-ray absorptiometry (DXA) measurements at the spine and hip levels. There is a growing demand for cheaper devices, free of ionizing radiation such as promising quantitative ultrasound (QUS). In common with many other countries, QUS measurements are increasingly used in Switzerland without adequate clinical guidelines. The T-score approach developed for DXA cannot be applied to QUS, although well-conducted prospective studies have shown that ultrasound could be a valuable predictor of fracture risk. As a consequence, an expert committee named the Swiss Quality Assurance Project (SQAP, for which the main mission is the establishment of quality assurance procedures for DXA and QUS in Switzerland) was mandated by the Swiss Association Against Osteoporosis (ASCO) in 2000 to propose operational clinical recommendations for the use of QUS in the management of osteoporosis for two QUS devices sold in Switzerland. Device-specific weighted "T-score" based on the risk of osteoporotic hip fractures as well as on the prediction of DXA osteoporosis at the hip, according to the WHO definition of osteoporosis, were calculated for the Achilles (Lunar, General Electric, Madison, Wis.) and Sahara (Hologic, Waltham, Mass.) ultrasound devices. Several studies (totaling a few thousand subjects) were used to calculate age-adjusted odd ratios (OR) and area under the receiver operating curve (AUC) for the prediction of osteoporotic fracture (taking into account a weighting score depending on the design of the study involved in the calculation). The ORs were 2.4 (1.9-3.2) and AUC 0.72 (0.66-0.77), respectively, for the Achilles, and 2.3 (1.7-3.1) and 0.75 (0.68-0.82), respectively, for the Sahara device. To translate risk estimates into thresholds for clinical application, 90% sensitivity was used to define low fracture and low osteoporosis risk, and a specificity of 80% was used to define subjects as being at high risk of fracture or having osteoporosis at the hip. From the combination of the fracture model with the hip DXA osteoporotic model, we found a T-score threshold of -1.2 and -2.5 for the stiffness (Achilles) determining, respectively, the low- and high-risk subjects. Similarly, we found a T-score at -1.0 and -2.2 for the QUI index (Sahara). Then a screening strategy combining QUS, DXA, and clinical factors for the identification of women needing treatment was proposed. The application of this approach will help to minimize the inappropriate use of QUS from which the whole field currently suffers.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: A single infusion of intravenous zoledronic acid decreases bone turnover and improves bone density at 12 months in postmenopausal women with osteoporosis. We assessed the effects of annual infusions of zoledronic acid on fracture risk during a 3-year period. METHODS: In this double-blind, placebo-controlled trial, 3889 patients (mean age, 73 years) were randomly assigned to receive a single 15-minute infusion of zoledronic acid (5 mg) and 3876 were assigned to receive placebo at baseline, at 12 months, and at 24 months; the patients were followed until 36 months. Primary end points were new vertebral fracture (in patients not taking concomitant osteoporosis medications) and hip fracture (in all patients). Secondary end points included bone mineral density, bone turnover markers, and safety outcomes. RESULTS: Treatment with zoledronic acid reduced the risk of morphometric vertebral fracture by 70% during a 3-year period, as compared with placebo (3.3% in the zoledronic-acid group vs. 10.9% in the placebo group; relative risk, 0.30; 95% confidence interval [CI], 0.24 to 0.38) and reduced the risk of hip fracture by 41% (1.4% in the zoledronic-acid group vs. 2.5% in the placebo group; hazard ratio, 0.59; 95% CI, 0.42 to 0.83). Nonvertebral fractures, clinical fractures, and clinical vertebral fractures were reduced by 25%, 33%, and 77%, respectively (P<0.001 for all comparisons). Zoledronic acid was also associated with a significant improvement in bone mineral density and bone metabolism markers. Adverse events, including change in renal function, were similar in the two study groups. However, serious atrial fibrillation occurred more frequently in the zoledronic acid group (in 50 vs. 20 patients, P<0.001). CONCLUSIONS: A once-yearly infusion of zoledronic acid during a 3-year period significantly reduced the risk of vertebral, hip, and other fractures. (ClinicalTrials.gov number, NCT00049829.)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Quantitative ultrasound (QUS) appears to be developing into an acceptable, low-cost and readily-accessible alternative to dual X-ray absorptiometry (DXA) measurements of bone mineral density (BMD) in the detection and management of osteoporosis. Perhaps the major difficulty with their widespread use is that many different QUS devices exist that differ substantially from each other, in terms of the parameters they measure and the strength of empirical evidence supporting their use. But another problem is that virtually no data exist outside of Caucasian or Asian populations. In general, heel QUS appears to be most tested and most effective. Some, but not all heel QUS devices are effective assessing fracture risk in some, but not all populations, the evidence being strongest for Caucasian females > 55 years old, though some evidence exists for Asian females > 55 and for Caucasian and Asian males > 70. Certain devices may allow to estimate the likelihood of osteoporosis, but very limited evidence exists supporting QUS use during the initiation or monitoring of osteoporosis treatment. Likely, QUS is most effective when combined with an assessment of clinical risk factors (CRF); with DXA reserved for individuals who are not identified as either high or low risk using QUS and CRF. However, monitoring and maintenance of test and instrument accuracy, precision and reproducibility are essential if QUS devices are to be used in clinical practice; and further scientific research in non-Caucasian, non-Asian populations clearly is compulsory to validate this tool for more widespread use.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Denosumab is a fully human monoclonal antibody to the receptor activator of nuclear factor-kappaB ligand (RANKL) that blocks its binding to RANK, inhibiting the development and activity of osteoclasts, decreasing bone resorption, and increasing bone density. Given its unique actions, denosumab may be useful in the treatment of osteoporosis. METHODS: We enrolled 7868 women between the ages of 60 and 90 years who had a bone mineral density T score of less than -2.5 but not less than -4.0 at the lumbar spine or total hip. Subjects were randomly assigned to receive either 60 mg of denosumab or placebo subcutaneously every 6 months for 36 months. The primary end point was new vertebral fracture. Secondary end points included nonvertebral and hip fractures. RESULTS: As compared with placebo, denosumab reduced the risk of new radiographic vertebral fracture, with a cumulative incidence of 2.3% in the denosumab group, versus 7.2% in the placebo group (risk ratio, 0.32; 95% confidence interval [CI], 0.26 to 0.41; P<0.001)--a relative decrease of 68%. Denosumab reduced the risk of hip fracture, with a cumulative incidence of 0.7% in the denosumab group, versus 1.2% in the placebo group (hazard ratio, 0.60; 95% CI, 0.37 to 0.97; P=0.04)--a relative decrease of 40%. Denosumab also reduced the risk of nonvertebral fracture, with a cumulative incidence of 6.5% in the denosumab group, versus 8.0% in the placebo group (hazard ratio, 0.80; 95% CI, 0.67 to 0.95; P=0.01)--a relative decrease of 20%. There was no increase in the risk of cancer, infection, cardiovascular disease, delayed fracture healing, or hypocalcemia, and there were no cases of osteonecrosis of the jaw and no adverse reactions to the injection of denosumab. CONCLUSIONS: Denosumab given subcutaneously twice yearly for 36 months was associated with a reduction in the risk of vertebral, nonvertebral, and hip fractures in women with osteoporosis. (ClinicalTrials.gov number, NCT00089791.)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Meta-analysis of prospective studies shows that quantitative ultrasound of the heel using validated devices predicts risk of different types of fracture with similar performance across different devices and in elderly men and women. These predictions are independent of the risk estimates from hip DXA measures.Introduction Clinical utilisation of heel quantitative ultrasound (QUS) depends on its power to predict clinical fractures. This is particularly important in settings that have no access to DXA-derived bone density measurements. We aimed to assess the predictive power of heel QUS for fractures using a meta-analysis approach.Methods We conducted an inverse variance random effects meta-analysis of prospective studies with heel QUS measures at baseline and fracture outcomes in their follow-up. Relative risks (RR) per standard deviation (SD) of different QUS parameters (broadband ultrasound attenuation [BUA], speed of sound [SOS], stiffness index [SI], and quantitative ultrasound index [QUI]) for various fracture outcomes (hip, vertebral, any clinical, any osteoporotic and major osteoporotic fractures) were reported based on study questions.Results Twenty-one studies including 55,164 women and 13,742 men were included in the meta-analysis with a total follow-up of 279,124 person-years. All four QUS parameters were associated with risk of different fracture. For instance, RR of hip fracture for 1 SD decrease of BUA was 1.69 (95% CI 1.43-2.00), SOS was 1.96 (95% CI 1.64-2.34), SI was 2.26 (95%CI 1.71-2.99) and QUI was 1.99 (95% CI 1.49-2.67). There was marked heterogeneity among studies on hip and any clinical fractures but no evidence of publication bias amongst them. Validated devices from different manufacturers predicted fracture risks with similar performance (meta-regression p values > 0.05 for difference of devices). QUS measures predicted fracture with a similar performance in men and women. Meta-analysis of studies with QUS measures adjusted for hip BMD showed a significant and independent association with fracture risk (RR/SD for BUA = 1.34 [95%CI 1.22-1.49]).Conclusions This study confirms that heel QUS, using validated devices, predicts risk of different fracture outcomes in elderly men and women. Further research is needed for more widespread utilisation of the heel QUS in clinical settings across the world.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Calcium is vital to the normal functioning of multiple organ systems and its serum concentration is tightly regulated. Apart from CASR, the genes associated with serum calcium are largely unknown. We conducted a genome-wide association meta-analysis of 39,400 individuals from 17 population-based cohorts and investigated the 14 most strongly associated loci in ≤ 21,679 additional individuals. Seven loci (six new regions) in association with serum calcium were identified and replicated. Rs1570669 near CYP24A1 (P = 9.1E-12), rs10491003 upstream of GATA3 (P = 4.8E-09) and rs7481584 in CARS (P = 1.2E-10) implicate regions involved in Mendelian calcemic disorders: Rs1550532 in DGKD (P = 8.2E-11), also associated with bone density, and rs7336933 near DGKH/KIAA0564 (P = 9.1E-10) are near genes that encode distinct isoforms of diacylglycerol kinase. Rs780094 is in GCKR. We characterized the expression of these genes in gut, kidney, and bone, and demonstrate modulation of gene expression in bone in response to dietary calcium in mice. Our results shed new light on the genetics of calcium homeostasis.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective. Vibration training (VT) is a new exercise method, with good acceptance among sedentary subjects, due to its passive principle: the machine moves the subject, not the opposite. We hypothesize that untrained subjects can benefit from a greater cardiovascular and metabolic stimulation than trained athletes, resembling classical aerobic-type activity, in addition of eliciting strength gains shown in diverse studies. Methods. 3 group of male subjects, inactive (SED), endurance trained athletes (END) and strength trained athletes (STR) underwent fitness (VO2max) and lower-body strength tests (isokinetic). Subjects were submitted to a session of oscillating VT, composed of 3 exercises (isometric half-squat, dynamic squat, dynamic squat with added load), each of 3 minutes duration, and repeated at 3 frequencies. VO2, heart rate and Borg scale were monitored. Results. 27 healthy subjects (10 SED, 9 END and 8 STR), mean age 24.5 (SED), 25.0 (STR) and 29.8 (END) were included. VO2max was significantly different as expected (47.9 vs. 52.9 vs. 63.9 ml/kg/min, resp. for SED, STR and END). Isokinetic dominant leg extensors strength was higher in STR (3.32 Nm/kg vs. 2.60 and 2.74 in SED and END). During VT, peak oxygen consumption (% of VO2max) attained was 59.3 in SED, 50.8 in STR and 48.0 in END (P<0.001 between SED and other subjects). Peak heart rate (% of heart rate max) was 82.7 in SED, 80.4 in STR and 72.4 in END. In SED, dynamic exercises without extra load elicited 51.0% of VO2max and 72.1% of heart rate max, and perceived effort reached 15.1/20. Conclusions. VT is an unconventional type of exercise, which has been shown to enhance strength, bone density, balance and flexibility. Users are attracted by the relative passivity. In SED, we show that VT elicits sufficient cardiovascular response to benefit overall fitness in addition to the known strength effects. VT's higher acceptance as an exercise in sedentary people, compared to jogging or cycling for example, can lead to better adherence to physical activity. Although long-term effects of VT on health are not avalaible, we believe this type of combination of aerobic and resistance-type exercise can be beneficial on multiple health parameters, especially cardiovascular health.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

At the age of 50, a woman has a lifetime risk of more than 40% to present a vertebral fracture. More than 60% of vertebral fractures remain undiagnosed. As a consequence it is of major importance to develop screening strategies to detect these fractures. Vertebral fracture assessment (VFA) by DXA allows one to detect vertebral fracture from T4 to L4 using DXA devices, while performing also during the same visit the bone mineral density measurement. Such an approach should improve the evaluation of fracture risk and therapeutic indication. Compared to the standard X-ray assessment, VFA highly enables to detect moderate or severe vertebral fractures below T6.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Patients with intestinal failure who receive HPN are at high risk of developing MBD. The origin of this bone alteration is multifactorial and depends greatly on the underlying disease for which the nutritional support is required. Data on the prevalence of this disease in our environment is lacking, so NADYA-SEMPE group has sponsored this transversal study with the aim of knowing the actual MBD prevalence. MATERIAL AND METHODS: Retrospective data from 51 patients from 13 hospitals were collected. The questionnaire included demographic data as well as the most clinically relevant for MBD data. Laboratory data (calciuria, PTH, 25 -OH -vitamin D) and the results from the first and last bone densitometry were also registered. RESULTS: Bone mineral density had only been assessed by densitometry in 21 patients at the moment HPN was started. Bone quality is already altered before HPN in a significant percentage of cases (52%). After a mean follow up of 6 years, this percentage increases up to 81%. Due to retrospective nature of the study and the low number of subjects included it has not been possible to determine the role that HPN plays in MBD etiology. Only 35% of patients have vitamin D levels above the recommended limits and the majority of them is not on specific supplementation. CONCLUSIONS: HPN is associated with very high risk of MBD, therefore, management protocols that can lead to early detection of the problem as well as guiding for follow up and treatment of these patients are needed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objectives: A multi-centered observational study evaluated the efficacy of zoledronic acid for improving pain and mobility, and preventing skeletal-related events (SRE) (fracture, spinal compression, pain-relieving radiotherapy), in patients with prostate cancer and bone metastasis. Materials and Methods: Males (n = 218) with prostate cancer and bone metastasis undergoing oncologic therapy received zoledronic acid (4 mg iv/month) for 6 months. Parameters evaluated were: 1) pain and movement after 2 consecutive doses; 2) quality of life; 3) SRE incidence and time-to-appearance. Medication tolerance and treatment satisfaction were assessed using a questionnaire. Results: A total of 170 that matched all the inclusion criteria (78%) out of 218 were evaluable for efficacy. There was a measurable statistically significant reduction in pain at rest and on movement as well as an improvement in the quality of life compared with baseline. Best results were obtained with early treatment. Overall incidence of bone events was 11.2%. Of the 212 patients (97.2%) evaluable for safety, 16% suffered adverse events and 66% expressed satisfaction with the treatment Discussion: Zoledronic acid is effective for reducing pain, improving mobility, and increasing the quality of life in patients with prostate cancer with bone metastasis. Its easy administration and good tolerability make zoledronic acid one of the principal therapeutic tools in the management of patients with pain associated with bone metastasis from prostate cancer.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: The principal aim of this study was to develop a Swiss Food Frequency Questionnaire (FFQ) for the elderly population for use in a study to investigate the influence of nutritional factors on bone health. The secondary aim was to assess its validity and both short-term and long-term reproducibility. DESIGN: A 4-day weighed record (4 d WR) was applied to 51 randomly selected women of a mean age of 80.3 years. Subsequently, a detailed FFQ was developed, cross-validated against a further 44 4-d WR, and the short- (1 month, n = 15) and long-term (12 months, n = 14) reproducibility examined. SETTING: French speaking part of Switzerland. SUBJECTS: The subjects were randomly selected women recruited from the Swiss Evaluation of the Methods of Measurement of Osteoporotic Fracture cohort study. RESULTS: Mean energy intakes by 4-d WR and FFQ showed no significant difference [1564.9 kcal (SD 351.1); 1641.3 kcal (SD 523.2) respectively]. Mean crude nutrient intakes were also similar (with nonsignifcant P-values examining the differences in intake) and ranged from 0.13 (potassium) to 0.48 (magnesium). Similar results were found in the reproducibility studies. CONCLUSION: These findings provide evidence that this FFQ adequately estimates nutrient intakes and can be used to rank individuals within distributions of intake in specific populations.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND Osteoporosis is a metabolic disorder characterized by a reduction in bone mass and deterioration in the microarchitectural structure of the bone, leading to a higher risk for spontaneous and fragility fractures.The main aim was to study the differences between human bone from osteoporotic and osteoarthritic patients about gene expression (osteogenesis and apoptosis), bone mineral density, microstructural and biomechanic parameters. METHODS We analyzed data from 12 subjects: 6 with osteoporotic hip fracture (OP) and 6 with hip osteoarthritis (OA), as the control group. All subjects underwent medical history, analytical determinations, densitometry, histomorphometric and biochemical study. The expression of 86 genes of osteogenesis and 86 genes of apoptosis was studied in pool of bone samples from patients with OP and OA by PCR array. RESULTS We observed that most of the genes of apoptosis and osteogenesis show a decrease in gene expression in the osteoporotic group in comparison with the osteoarthritic group. The histomorphometric study shows a lower bone quality in the group of patients with hip fractures compared to the osteoarthritic group. CONCLUSIONS The bone tissue of osteoporotic fracture patients is more fragile than the bone of OA patients. Our results showed an osteoporotic bone with a lower capacities for differentiation and osteoblastic activity as well as a lower rate of apoptosis than osteoarthritic bone. These results are related with structural and biochemical parameters.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

SUMMARY: BMD and clinical risk factors predict hip and other osteoporotic fractures. The combination of clinical risk factors and BMD provide higher specificity and sensitivity than either alone. INTRODUCTION AND HYPOTHESES: To develop a risk assessment tool based on clinical risk factors (CRFs) with and without BMD. METHODS: Nine population-based studies were studied in which BMD and CRFs were documented at baseline. Poisson regression models were developed for hip fracture and other osteoporotic fractures, with and without hip BMD. Fracture risk was expressed as gradient of risk (GR, risk ratio/SD change in risk score). RESULTS: CRFs alone predicted hip fracture with a GR of 2.1/SD at the age of 50 years and decreased with age. The use of BMD alone provided a higher GR (3.7/SD), and was improved further with the combined use of CRFs and BMD (4.2/SD). For other osteoporotic fractures, the GRs were lower than for hip fracture. The GR with CRFs alone was 1.4/SD at the age of 50 years, similar to that provided by BMD (GR = 1.4/SD) and was not markedly increased by the combination (GR = 1.4/SD). The performance characteristics of clinical risk factors with and without BMD were validated in eleven independent population-based cohorts. CONCLUSIONS: The models developed provide the basis for the integrated use of validated clinical risk factors in men and women to aid in fracture risk prediction.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Given the significant impact the use of glucocorticoids can have on fracture risk independent of bone density, their use has been incorporated as one of the clinical risk factors for calculating the 10-year fracture risk in the World Health Organization's Fracture Risk Assessment Tool (FRAX(®)). Like the other clinical risk factors, the use of glucocorticoids is included as a dichotomous variable with use of steroids defined as past or present exposure of 3 months or more of use of a daily dose of 5 mg or more of prednisolone or equivalent. The purpose of this report is to give clinicians guidance on adjustments which should be made to the 10-year risk based on the dose, duration of use and mode of delivery of glucocorticoids preparations. A subcommittee of the International Society for Clinical Densitometry and International Osteoporosis Foundation joint Position Development Conference presented its findings to an expert panel and the following recommendations were selected. 1) There is a dose relationship between glucocorticoid use of greater than 3 months and fracture risk. The average dose exposure captured within FRAX(®) is likely to be a prednisone dose of 2.5-7.5 mg/day or its equivalent. Fracture probability is under-estimated when prednisone dose is greater than 7.5 mg/day and is over-estimated when the prednisone dose is less than 2.5 mg/day. 2) Frequent intermittent use of higher doses of glucocorticoids increases fracture risk. Because of the variability in dose and dosing schedule, quantification of this risk is not possible. 3) High dose inhaled glucocorticoids may be a risk factor for fracture. FRAX(®) may underestimate fracture probability in users of high dose inhaled glucocorticoids. 4) Appropriate glucocorticoid replacement in individuals with adrenal insufficiency has not been found to increase fracture risk. In such patients, use of glucocorticoids should not be included in FRAX(®) calculations.