974 resultados para Bifurcated stent Graft


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Graft rejection is the major cause of failure of HLA mismatched bone marrow transplantation because of residual host immunity. we have proposed to use a monoclonal murine antibody specific for the LFA-1 molecule (25-3) to prevent graft failure in HLA mismatched bone marrow transplantation (BMT). The rationale for this approach is three fold: LFA-1 deficient patients (3/3) do not reject HLA mismatched BMT; anti LFA-1 blocka in vitro the induction of T cell responses and T/ non T cytotoxic functions; LFA-1 is not expressed by other cells than leucocytes. We have accordingly treated twenty two patients with inherited diseases and 8 with leikemia. The bone marrow was T cells depled by E rosetting of Campath antibody. The antibody was given at days -3, -1, +1, +3, +5 at dose of .1 mg/kg/d for the first 9 and then .2mg/kg/d from day -3 to +6. Engraftment occured in 23/30 patients as shown by at least HLA typing. Hematological recovery was rapid, GVH was limited. Side effects of antibody infusion included fever and possibly an increased incidence of early bacteral infection (sepsis, 1 death). Immunological reconstitution occured slowly leading in six cases to EBV-induced B cell poliferation (1 death and in two others to transient auto immune hemolytic anemia. There has been only one secondary graft rejection. Sisteen patients are alive 3 to 26 months post transplant with functional grafts. Although the number of patients treated is still low the absence of late rejection so far, gives hope for long term maintenance of the graft using anti LFA-1. Since the antibody is an IgG 1 unable to bind human complement, and since it is known to inhibit phagocytosis, there is a good suggestion that 25-3 act through functional blocking of host T and non T luymphocytes at both induction and effector levels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Mycobacterium tuberculosis may cause a large variety of clinical presentations due to its ability to disseminate by contiguity or hematogenously. Tuberculosis may remain undiagnosed for years due to the chronic course of the disease, with potentially life-threatening long-term complications. CASE PRESENTATION: In this case report, we describe a tuberculous aortic graft infection in a 72-year-old man documented by polymerase chain reaction and cultures. The patient presented with three episodes of hemoptysis following a remote history of miliary tuberculosis. The infection was treated by graft replacement and prolonged antimycobacterial therapy. CONCLUSION: Tuberculous infection of a vascular graft is an uncommon complication, but should be considered in patients with an intravascular device and a history of previous tuberculosis, especially when hematogenous spread may have occurred a few months after surgery, or when an active mycobacterial infection is present in close proximity to the graft.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Patients who develop a severe stenosis in biological pulmonary conduits previously implanted for pulmonary outflow trunk reconstructions are treated either by surgical re-replacement, or by transcatheter stent-valve implantation through a femoral vein access. A catheter-based sub-xyphoidian access through the right ventricle for stent-valve positioning in a pulmonary conduit has rarely been proposed. We describe the case of a 20-year-old man who underwent a pulmonary trunk reconstruction for a congenital pulmonary valve dysplasia and a few years later developed a stenosis in the pulmonary conduit. He was successfully treated with a 23 mm Edwards Sapien stent-valve implantation in pulmonary position, through an unusual right ventricular, sub-xyphoidian access and without contrast medium injections and pleura opening.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

SUMMARY: Coil displacement during endovascular coiling procedures may require coil retrieval in the context of flow limitation or thromboembolic risk. No standard recommended method of coil retrieval exists. We present a consecutive series of 14 patients with displaced coil during aneurysm coiling in whom the complication was effectively managed with the use of a stent retriever system. Two illustrative cases from the 14 are described, and technical notes are detailed regarding use of the technique. The use of stent retrievers presents a simple, safe, and effective choice for removal of prolapsed coils during aneurysm coiling.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the feasibility of visualizing the stent lumen using coronary magnetic resonance angiography in vitro. MATERIAL AND METHODS: Nineteen different coronary stents were implanted in plastic tubes with an inner diameter of 3 mm. The tubes were positioned in a plastic container filled with gel and included in a closed flow circuit (constant flow 18 cm/sec). The magnetic resonance images were obtained with a dual inversion fast spin-echo sequence. For intraluminal stent imaging, subtraction images were calculated from scans with and without flow. Subsequently, intraluminal signal properties were objectively assessed and compared. RESULTS: As a function of the stent type, various degrees of in-stent signal attenuation were observed. Tantalum stents demonstrated minimal intraluminal signal attenuation. For nitinol stents, the stent lumen could be identified, but the intraluminal signal was markedly reduced. Steel stents resulted in the most pronounced intraluminal signal voids. CONCLUSIONS: With the present technique, radiofrequency penetration into the stents is strongly influenced by the stent material. Thesefindings may have important implicationsforfuture stent design and stent imaging strategies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intraoperative cardiac imaging plays a key role during transcatheter aortic valve replacement. In recent years, new techniques and new tools for improved image quality and virtual navigation have been proposed, in order to simplify and standardize stent valve positioning and implantation. But routine performance of the new techniques may require major economic investments or specific knowledge and skills and, for this reason, they may not be accessible to the majority of cardiac centres involved in transcatheter valve replacement projects. Additionally, they still require injections of contrast medium to obtain computed images. Therefore, we have developed and describe here a very simple and intuitive method of positioning balloon-expandable stent valves, which represents the evolution of the 'dumbbell' technique for echocardiography-guided transcatheter valve replacement without angiography. This method, based on the partial inflation of the balloon catheter during positioning, traps the crimped valve in the aortic valve orifice and, consequently, very near to the ideal landing zone. It does not require specific echocardiographic knowledge; it does not require angiographies that increase the risk of postoperative kidney failure in elderly patients, and it can be also performed in centres not equipped with a hybrid operating room.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A cardiac-triggered free-breathing three-dimensional (3D) balanced fast field-echo projection renal magnetic resonance (MR) angiographic sequence was investigated for in-stent lumen visualization of a dedicated metallic renal artery stent. Fourteen prototype stents were deployed in the renal arteries of six pigs (in two pigs, three stents were deployed). Projection renal MR angiography was compared with standard contrast material-enhanced 3D breath-hold MR angiography. Artifact-free in-stent lumen visualization was achieved with both projection MR angiography and contrast-enhanced MR angiography. These promising results warrant further studies for visualization of in-stent restenosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: The presence of intravascular foreign bodies is underreported in the literature and is more commonly encountered in clinical practice. We report on a case where an attempt to position a carotid stent resulted in misdeployment of the stent in the femoral artery and its surgical removal. METHODS: A 63-year-old patient admitted to hospital for cerebral stroke underwent thrombolysis for occlusive dissection of right carotid artery and was transferred to our hospital for additional thrombo-aspiration and carotid stenting. RESULTS: The carotid stent was misdeployed incompletely in the femoral artery and had to be removed surgically. CONCLUSIONS: Appropriate knowledge of intravascular migration and deployment failure management should be considered as important as the optimal device deployment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Nitrosative stress takes place in endothelial cells (EC) during corneal acute graft rejection. The purpose of this study was to evaluate the potential role of peroxynitrite on corneal EC death. METHODS: The effect of peroxynitrite was evaluated in vivo. Fifty, 250, and 500 microM in 1.5 microL of the natural or denatured peroxynitrite in 50 microM NaOH, 50 microM NaOH alone, or balanced salt solution were injected into the anterior chamber of rat eyes (n=3/group). Corneal toxic signs after injection were assessed by slit-lamp, in vivo confocal imaging, pachymetry, and EC count. The effect of peroxynitrite was also evaluated on nitrotyrosine and leucocyte elastase inhibitor/LDNase II immunohistochemistry. Human corneas were incubated with peroxynitrite and the effect on EC viability was evaluated. A specific inducible nitric oxide synthase inhibitor (iNOS) was administered systemically in rats undergoing allogeneic corneal graft rejection and the effect on EC was evaluated by EC count. RESULTS: Rat eyes receiving as little as 50 microM peroxynitrite showed a specific dose-dependent toxicity on EC. We observed an intense nitrotyrosine staining of human and rat EC exposed to peroxynitrite associated with leucocyte elastase inhibitor nuclear translocation, a noncaspase dependent apoptosis reaction. Specific inhibition of iNOS generation prevented EC death and enhanced EC survival of the grafted corneas. However, inhibition of iNOS did not have a significant influence on the incidence of graft rejection. CONCLUSION: Nitrosative stress during acute corneal graft rejection in rat eyes induces a noncaspase dependent apoptotic death in EC. Inhibition of nitric oxide production during the corneal graft rejection has protective effects on the corneal EC survival.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The success of allogeneic hematopoietic cell transplantation is limited by acute graft-versus-host disease (GvHD), a severe complication accompanied by high mortality rates. Yet, the molecular mechanisms initiating this disease remain poorly defined. In this study, we show that, after conditioning therapy, intestinal commensal bacteria and the damage-associated molecular pattern uric acid contribute to Nlrp3 inflammasome-mediated IL-1β production and that gastrointestinal decontamination and uric acid depletion reduced GvHD severity. Early blockade of IL-1β or genetic deficiency of the IL-1 receptor in dendritic cells (DCs) and T cells improved survival. The Nlrp3 inflammasome components Nlrp3 and Asc, which are required for pro-IL-1β cleavage, were critical for the full manifestation of GvHD. In transplanted mice, IL-1β originated from multiple intestinal cell compartments and exerted its effects on DCs and T cells, the latter being preferentially skewed toward Th17. Compatible with these mouse data, increased levels of active caspase-1 and IL-1β were found in circulating leukocytes and intestinal GvHD lesions of patients. Thus, the identification of a crucial role for the Nlrp3 inflammasome sheds new light on the pathogenesis of GvHD and opens a potential new avenue for the targeted therapy of this severe complication.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: Following open-heart surgery, sternal osteomyelitis or infection of the graft may be a serious complication with high mortality rates. The recommended treatment of an infected graft is its explantation. Because of the poor performance status of the patient, this may not always be an option. We report a successful treatment concept without removal of the infected graft. Methods: The infected ascending aortic graft and the remaining sternum of a critically ill 60-year-old man were covered with a bilateral pectoralis muscle flap. Results: Postoperatively, the laboratory test values normalized and the patient was discharged 1 month after the intervention. One year after surgery, the patient was in good condition and the examination showed no signs of infection. Conclusion: The thus demonstrated treatment concept with insertion of well-vascularized tissues in combination with a specific antibiotic regime in our hands proved to be an additional option for the successful management of life-threatening infections of a sternal osteomyelitis in combination of an infected aortic graft.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The aim of this study was to investigate the feasibility of transventricular-transseptal approach (TVSA) for extrapleural transcatheter aortic valved stent implantation via a subxyphoidian access. Methods: In five porcine experiments (52.3 +/- 10.9 kg) the right ventricle was exposed via subxyphoidian access. Under the guidance of intracardiac echocardiography (ICE) and fluoroscopy, the transseptal access from right ventricle to left ventricle was created progressively by puncture and dilation with dilators (8F-26F). Valved stents built in-house from commercial tanned pericardium and self-expandable Nitinol stents were loaded into a cartridge. A delivery sheath was then introduced from the right ventricle into the left ventricle and then into the ascending aorta. The cartridge was connected and the valved stent was deployed in the aortic position. Then, the ventricular septal access was sealed with an Amplatzer septal occluder device and the right ventricular access was closed by tying prepared purse-string suture directly. Thirty minutes after the whole procedure, the animals were sacrificed for macroscopic evaluation of the position of valved stent and septal closure device. Result: Procedural success of TVSA was 100% at the first attempt. Mean procedure time was 49 +/- 4 min. Progressive dilatation of the transseptal access resulted in a measurable ventricular septal defect (VSD) after dilator sizes 18F and more. All valved stents were delivered at the target site over the native aortic valve with good acute valve function and no paravalvular leaks. During the procedure, premature beats (5/5) and supraventriclar tachycardias (5/5) were observed, but no atrial-ventricular block (0/5) occurred. Heart rate before (after) was 90 +/- 3 beats min(-1) (100 +/- 2 beats min(-1): p < 0.05), whereas blood pressure was 60 + 1 mm Hg (55 + 2 mm Hg (p < 0.05)). Total blood loss was 280 + 10 ml. The Amplatzer septal occluder devices were fully deployed and the ventricular septal accesses were sealed successfully, without detectable residual shunt. Conclusion: Trans-catheter implantation of aortic valved stent via extrapleural transventricular-transseptal access is technically feasible and has the potential for a simplified procedure under local anaesthesia. (C) 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B. V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose:  To evaluate the current management, and adherence to recommendations, of patients on oral anticoagulation (OAC) undergoing coronary stent implantation (PCI-S). Methods:  By means of a contact person who had been previously identified in 8 European countries, a questionnaire was electronically forwarded between April and July 2010 to the national institutions where PCI-S is performed. Results:  A total of  202 questionnaires (median response rate: 50%, range 33-78%) was received. The prevalence of OAC patients among those undergoing PCI-S is mostly reported 5-10% (97%). The peri-procedural pharmacological management mostly encompasses: preprocedural OAC interruption and bridging with low-molecular-weight heparin (59%), intraprocedural administration of an unfractionated heparin bolus (81%), and use of glycoprotein IIb/IIIa inhibitors on an individual basis (79%). The radial approach is reported as the preferred option (58%), as well as the implantation of bare metal stents (76%). Triple therapy (warfarin, aspirin, clopidogrel) is the most frequently prescribed (80%), generally for 1 month after bare metal stent (77%) and for at least 12 months after drug-eluting stent (60%). Throughout triple therapy, the International Normalized Ratio is mostly targeted to the lower end of the therapeutic range (77%), and gastric protection is routinely prescribed (69%), mostly by giving proton-pump inhibitors (70%). Conclusions:  Among the 202 interventional cardiologists from the 8 European countries interviewed, the management of patients on OAC undergoing PCI-S appears variable and only partially adherent to currently available recommendations. (J Interven Cardiol 2012;25:163-169).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Incidence of perioperative in-stent thrombosis associated with myocardial infarction in patients undergoing major lung resection within 3 months of coronary stenting. METHODS: Retrospective multi-institutional trial including all patients undergoing major lung resection (lobectomy or pneumonectomy) within 3 months of coronary stenting with non-drug-eluting stents between 1999 and 2004. RESULTS: There were 32 patients (29 men and 3 women), with age ranging from 46 to 82 years. One, two or four coronary stents were deployed in 72%, 22% and 6% of the patients, respectively. The time intervals between stenting and lung surgery were <30 days, 30-60 days and 61-90 days in 22%, 53% and 25% of the patients, respectively. All patients had dual antiplatelet therapy after stenting. Perioperative medication consisted of heparin alone or heparin plus aspirin in 34% and 66% of the patients, respectively. Perioperative in-stent thrombosis with myocardial infarction occurred in three patients (9%) with fatal outcome in one (3%). Twenty patients underwent lung resection after 4 weeks of dual antiplatelet therapy as recommended by the ACC/AHA Guideline Update; however, two out of three perioperative in-stent thrombosis occurred in this group of patients. CONCLUSIONS: Major lung resection performed within 3 months of coronary stenting may be complicated by perioperative in-stent thrombosis despite 4 weeks of dual antiplatelet therapy after stenting as recommended by the ACC/AHA Guideline Update.