324 resultados para BEH-PPV
Resumo:
Polymer light-emitting devices (PLEDs) have been produced with Langmuir-Blodgett (LB) films from poly(2-methoxy-5-hexyloxy)-p-phenylenevinylene (OC1OC6-PPV) as the emissive layer and an ionomer of a copolymer of styrene and methylmethacrylate (PS/PMMA) as an electron-injection layer. The main features of such devices are the low operating voltages, obtainable firstly due to the good quality of the ultrathin LB films that allows PLEDs to be produced reproducibly and secondly due to the improved electrical and luminance properties brought by the electron-injection layer. Also demonstrated is the superior performance of an all-LB device compared to another one produced with cast films of the same materials. Published by Elsevier B.V.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
OBJETIVOS: comparar dois testes de rastreamento do diabete gestacional. MÉTODOS: estudo prospectivo no qual foram avaliadas 356 gestantes, sem diagnóstico prévio do diabete melito, submetidas, de modo independente, a dois testes de rastreamento: associação glicemia de jejum e fator de risco (GJ+FR) e teste oral simplificado de tolerância à glicose (TTG50g). A comparação entre os métodos foi realizada pelos índices de sensibilidade (S), especificidade (E) e valores preditivos positivo (VPP) e negativo (VPN), resultados falsos, positivos (FP) e negativos (FN) e pela diferença dos resultados observados e esperados, avaliada pelo teste do Qui-quadrado (p<0,05). RESULTADOS: a associação GJ+FR determinou a confirmação diagnóstica em maior número de gestantes (187; 52,5%) que o TTG50g (49; 13,8%). Esta diferença foi significativa (p<0,05). A associação GJ+FR apresentou sensibilidade de 83,7% e valor preditivo negativo (VPN) de 95,3% em relação ao TTG50g. CONCLUSÕES: os índices elevados de sensibilidade e VPN da associação GJ+FR em relação ao TTG50g, sua simplicidade, praticidade, baixo custo e fácil replicação permitem sua indicação no rastreamento do diabete gestacional.
Resumo:
CONTEXTO E OBJETIVO: A falta de consenso sobre os protocolos de rastreamento e diagnóstico do diabetes gestacional, associada às dificuldades na realização do teste oral simplificado do diabete gestacional (o teste de tolerância a 100 g de glicose, considerado padrão-ouro) justificam a comparação com alternativas. O objetivo deste trabalho é comparar o teste padrão-ouro a dois testes de rastreamento: associação de glicemia de jejum e fatores de risco (GJ + FR) e o teste oral simplificado de tolerância a 50 g de glicose (TTG 50 g), com o teste de tolerância a 100 g de glicose (TTG 100 g). TIPO DE ESTUDO E LOCAL: Estudo de coorte longitudinal, prospectivo, realizado no Serviço de Ginecologia e Obstetrícia do Hospital Universitário da Universidade Federal de Mato Grosso do Sul. MÉTODOS: 341 gestantes foram submetidas aos três testes. Calcularam-se os índices de sensibilidade (S), especificidade (E), valores preditivos (VPP e VPN), razões de probabilidade (RPP e RPN) e resultados falsos (FP e FN), positivos e negativos da associação GJ + FR e do TTG 50 g em relação ao TTG 100 g. Compararam-se as médias das glicemias de uma hora pós-sobrecarga (1hPS) com 50 e 100 g. Na análise estatística, empregou-se o teste t de Student, com limite de significância de 5%. RESULTADOS: A associação GJ + FR encaminhou mais gestantes (53,9%) para a confirmação diagnóstica que o TTG 50 g (14,4%). Os dois testes foram equivalentes nos índices de S (86,4 e 76,9%), VPN (98,7 e 98,9%), RPN (0,3 e 0,27) e FN (15,4 e 23,1%). As médias das glicemias 1hPS foram semelhantes, 106,8 mg/dl para o TTG 50 g e 107,5 mg/dl para o TTG 100 g. CONCLUSÕES: Os resultados da eficiência diagnóstica associados à simplicidade, praticabilidade e custo referendaram a associação GJ + FR como o mais adequado para o rastreamento. A equivalência das glicemias de 1hPS permitiram a proposição de um novo protocolo de rastreamento e diagnóstico do diabete gestacional, com menores custo e desconforto.
Resumo:
The present study analyzed the (ICHD I-1988) and ( ICHD II-2004) diagnostic criteria in children and adolescents. Our population consisted of 496 patients of the Headache Outpatient Ward for Children and Adolescents retrospectively studied from 1992 to 2002. Individuals were classified according to three diagnostic groups: Intuitive Clinical Diagnosis ( Gold Standard), ICHD I-1988 and ICHD II-2004. They were statistically compared using the variables: Sensitivity ( S), Specificity (Sp), Positive Predictive Value (PPV), Negative Predictive Value (NPV). When ICHD I-1988 was used, the sensitivity of migraine without and with aura was 21% and 27%, respectively, whereas in ICHD II-2004 it changed to 53% and 71% without affecting specificity. As a conclusion, the current classification criteria ( ICHD II-2004) showed greater sensitivity and high specificity for migraine than ICHD I-1988, although it improved migraine diagnosis in children and adolescents, the sensitivity remains poor.
Resumo:
OBJETIVO: O objetivo geral foi detectar fatores ambliopigênicos em uma população de pré-escolares, utilizando exames refratométricos e o PhotoScreenerTM (PS) e o objetivo específico foi verificar se a avaliação feita com o PS é útil como método de triagem em campanhas de prevenção de ambliopia em crianças. MÉTODOS: Foi realizado um estudo observacional, prospectivo, de janeiro a dezembro de 2007, avaliando-se 227 crianças pré-escolares, com o intuito de detectar, através da aplicação de um questionário, exames refratométricos e fotografias utilizando o PS, a presença de fatores causadores de ambliopia na população de estudo. Todas as crianças foram avaliadas pelo PS. em seguida, todas as crianças foram submetidas à cicloplegia , sendo avaliadas usando refrator automático Shin Nippon®. As crianças detectadas como portadoras de problemas oculares receberam prescrição óptica, segundo os critérios: hipermetropia maior que +1,50 D, miopia maior que -1,00 D e astigmatismo maior que 1,00 D. Analisaram-se os dados através do teste de concordância de Goodman, estatística descritiva e estudo da especificidade e sensibilidade ao emprego do PS, comparando os resultados com ele obtidos, com os resultados dos outros métodos de avaliação oftalmológica. RESULTADOS: A distribuição entre os sexos foi semelhante, sendo que a maioria das crianças apresentava quatro ou cinco anos de idade. A sensibilidade (S) do PS, comparando-se o resultado obtido neste aparelho com o autorrefrator sob cicloplegia, foi de 50,9%. Já a especificidade foi de 78,9%; valor preditivo positivo 70%; valor preditivo negativo 62,5% e acurácia 65,1%. CONCLUSÕES: Das 101 crianças cujas fotografias tiradas através do PS puderam ser analisadas satisfatoriamente, trinta e seis apresentavam erro refrativo que necessitou de correção. O PS, quando comparado com equivalente esférico do autorrefrator sob cicloplegia, é um método razoável de triagem, embora a sensibilidade não seja boa. Um ponto positivo a ser ressaltado é o considerável valor de especificidade.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The 3'-terminal 853 nt (and the putative 283 aa) sequence of the VP2-encoding gene from 29 field strains of porcine parvovirus (PPV) were determined and compared both to each other and with other published sequences. Sequences were examined using maximum-parsimony and statistical analyses for nucleotide diversity and sequence variability. Among the nucleotide sequences of the PPV field strains, 26 polymorphic sites were encountered; 22 polymorphic sites were detected in the putative amino acid sequence. Mapping polymorphic sites of protein data onto the three-dimensional (3D) structure of PPV VP2 revealed that almost all substitutions were located on the external surface of the viral capsid. Mapping amino acid substitutions to the alignment between PPV VP2 sequences and the 3D structure of canine parvovirus (CPV) capsid, many PPV substitutions were observed to map to regions of recognized antigenicity and/or to contain phenotypically important residues for CPV and other parvoviruses. In spite of the high sequence similarity, genetic analysis has shown the existence of at least two virus lineages among the samples. In conclusion, these results highlight the need for close surveillance on PPV genetic drift, with an assessment of its potential ability to modify the antigenic make-up of the virus.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
As atividades que envolvem o uso de explosivos devem ser controladas, não só com relação ao desmonte de estruturas (rocha e outros materiais), mas também quanto a danos estruturais em edificações próximas (casas, edificações históricas, etc.) e outros impactos ambientais como vibração, propagação de ruídos, ultralançamentos e sobrepressão atmosférica. Tais atividades são regidas por normas técnicas que sugerem parâmetros de medição e limites definidos na avaliação de prováveis danos. No caso específico de minerações em áreas urbanas, a velocidade de vibração de partícula (Vp), normalmente expressa em mm/s, é o parâmetro que tem dado melhor correlação na avaliação de possíveis danos às estruturas civis, atribuídos às vibrações do terreno. As diferentes normas existentes apresentam valores de Vp que variam de 2mm/s para edifícios históricos até 150mm/s para construções em concreto armado. A maioria delas considera na avaliação de danos estruturais, além da velocidade, a freqüência da vibração. Algumas normas foram elaboradas com base em dados experimentais, analisando parâmetros como o tipo de construção e o material nela utilizados, outras se basearam apenas em valores empíricos, mas todas apresentam valores conservativos. A norma brasileira não avalia o parâmetro freqüência e não classifica os diferentes tipos de estruturas civis, restringindo-se ao valor resultante da velocidade de vibração como parâmetro medido, sendo, assim, limitada e deficiente em relação às normas internacionais. A coletânea aqui apresentada reuniu as normas nas Américas e em outros continentes, além de uma comparação com as normas européias mais importantes em âmbito mundial.
Resumo:
Alterações anatômicas e fisiológicas da gravidez predispõem gestantes a infecções do trato urinário (ITU). O objetivo deste estudo foi identificar a acurácia do exame de urina simples para diagnóstico de ITU em gestantes de baixo risco. Fez-se uso do estudo de desempenho de teste diagnóstico realizado em Botucatu, SP, com 230 gestantes, entre 2006 e 2008. Os resultados mostram que a prevalência de ITU foi de 10%. A sensibilidade foi 95,6%, especificidade 63,3% e acurácia 66,5% do exame de urina simples, em relação ao diagnóstico de ITU. A análise dos valores preditivos positivo e negativo (VPP e VPN) mostrou que, na vigência de exame de urina simples normal, a chance de haver ITU foi pequena (VPN 99,2%). Frente ao resultado alterado desse exame, a probabilidade de haver ITU foi baixa (VPP 22,4%). Conclui-se que a acurácia do exame de urina simples como meio diagnóstico de ITU foi baixa, sendo indispensável a realização de urocultura para o diagnóstico.
Resumo:
A simple model of electron transfer is adapted to explain fluorescence quenching in self-assembled films of poly( p-phenylene vinylene) (PPV) alternating with poly(thiophene acetic acid) (PTAA). Quenching is caused by a photo-induced electron transfer between the excited PPV (donor, D) and the PTAA (acceptor, A). The electron-transfer process can be mediated by insertion of electronically inert spacing bilayers between the D and A layers, As the number of bilayers is increased, the fluorescence is gradually recovered which is explained theoretically by assuming that the electron-transfer rate can be described as k = Z exp(- beta r) where r is the distance between D and A. (C) 2000 Elsevier B.V. B.V. All rights reserved.
Resumo:
Purpose: To compare the safety and anti-inflammatory efficacy of a single posterior subtenon injection of triamcinolone acetonide (TA) with prednisolone acetate 1% eyedrops after pars plana vitrectomy (PPV).Methods: the study included 40 consecutive phakic eyes of 40 patients undergoing PPV for non-clearing vitreous haemorrhage with attached retina (verified by echography), epiretinal membrane or macular hole. At the end of the surgical procedure, eyes were randomized to receive either a single posterior subtenon injection of TA (40 mg in 1 ml) plus sham eyedrops (prednisolone acetate 1% vehicle) postoperatively (group TA), or a posterior subtenon sham injection (1 ml balanced salt solution) plus prednisolone acetate 1% eyedrops postoperatively (group ED).Results: There was no difference in the severity of anterior chamber cell and flare between the two groups at any time-point during the study period (p > 0.05). Separate within-group analysis revealed a significant decrease in anterior chamber cell and flare from postoperative day 1 to postoperative days 7, 14 and 28 in both groups (p < 0.05). There was no difference in pain, photophobia, conjunctival erythema, ciliary flush or chemosis scores between the two groups at any time-point during the study period (p > 0.05). Steroid-induced intraocular hypertension was not observed in either group.Conclusions: A single posterior subtenon injection of TA can be as effective and safe as a 4-week regimen of prednisolone acetate 1% eyedrops in controlling intraocular inflammation after PPV.
Resumo:
We present atomic force microscopic images of the interphase morphology of vertically segregated thin films spin coated from two-component mixtures of poly[2-methoxy-5-(2'-ethylhexyloxy)-1,4-phenylene-vinylene] (MEH-PPV) and polystyrene (PS). We investigate the mechanism leading to the formation of wetting layers and lateral structures during spin coating using different PS molecular weights, solvents and blend compositions. Spinodal decomposition competes with the formation of surface enrichment layers. The spinodal wavelength as a function of PS molecular weight follows a power-law similar to bulk-like spinodal decomposition. Our experimental results indicate that length scales of interface topographical features can be adjusted from the nanometer to micrometer range. The importance of controlled arrangement of semiconducting polymers in thin film geometries for organic optoelectronic device applications is discussed. (c) 2007 Elsevier Ltd. All rights reserved.