979 resultados para Aquecimento vocal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We studied the feasibility of using a system of Solar Water Heating (SAS) with low cost, for three configurations. In configurations I and II have the collector grid absorber composed of six PVC tubes placed in parallel on the tile cement. In configuration II, the PVC tubes were transparent cover made of plastic bottles. Configuration III uses a collector composed of 12 black HDPE pipes, supported on four cement tiles 2.44 m x 0.50 m, two by two overlapping and interspersed with a filling of glass wool, comprising an area exposed to the global radiation incident of 2.44 m2, with the top two tiles painted matte black. In this configuration, the HDPE pipes replace conventional PVC pipes painted black. The total cost of SAS for configuration III, the most economical, was around $ 150.00. For the configurations tested the system of operation was thermosyphon collector. The study showed that the proposed systems have good thermal efficiency, are easy to install and handle and have low cost compared to conventional.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It was studied a system for heating water to be used to obtain water for bathing at home, the absorbing surface of the collector is formed by one plate of polycarbonate. The polycarbonate plate has 6 mm thick, 1.050 mm wide and 1.500 mm long with an area equal to 1,575 m². The plate was attached by its edges parallel to PVC tubes of 32 mm. The system worked under the thermo-siphon and was tested for two configurations: plate absorber with and without isolation of EPS of 30 mm thick on the bottom surface in order to minimize heat losses from the bottom. The tank's thermal heating system is alternative and low cost, since it was constructed from a polyethylene reservoir for water storage, with a volume of 200 liters. Will present data on the thermal efficiency, heat loss, water temperature of thermal reservoir at the end of the process simulation and baths. Will be demonstrated the feasibility of thermal, economic and material pickup proposed for the intended purpose.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents an analysis of technical and financial feasibility of the use of a solar system for water heating in a fictitious hotel located in the Northeast region. Thereunto it is used techniques of solar collectors´ sizing and methods of financial mathematics, such as Net Present Value (NPV), Internal Rate of Return (IRR) and Payback. It will also be presented a sensitivity analysis to verify which are the factors that impact the viability of the solar heating. Comparative analysis will be used concerning three cities of distinct regions of Brazil: Curitiba, Belém and João Pessoa. The viability of using a solar heating system will be demonstrated to the whole Brazil, especially to the northeast region as it is the most viable for such an application of solar power because of its high levels of solar radiation. Among the cities examined for a future installation of solar heating systems for water heating in the hotel chain, João Pessoa was the one that has proved more viable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Due to the increasing need to promote the use of resources that support the environment and the clean industry, the science has developed in the area of natural resource use as well as enhanced use of the renewable energy sources. Considering also the great need for clean water and wide availability of salt or brackish water, added to the great solar energy potential in northeastern of the Brazil, it was developed a solar distiller whose main difference is its system of pre-solar heating also. From experimental adjustments, the system was developed by the use of a cylindrical solar concentrator coupled to a conventional distiller. The system is designed such that attempt to facilitate the process termination trap to ensure constant movement of the fluid mass and thus enable higher temperatures to the system and thus fetch a higher amount of distillate collected. In a stage of the experiment were used a forced circulation to try to further increase the amount of energy exchange system. To develop the study were set up four settings for comparison in which one was only distiller simple as basic parameter, the second proposed configuration were with the coupling of the concentration triggered manually every 30 minutes to monitor the sun, the third configuration occurred with automatic triggering of a timer, and the fourth configuration was also used a pumping system that tried to improve the circulation of the fluid. With the comparative analysis of the results showed a gain in the amount of distillate system, especially in the forced model

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present work, we have studied the nature of the physical processes of the coronal heating, considering as basis significant samples of single and binary evolved stars, that have been achieved with the ROSAT satellite. In a total of 191 simple stars were studied, classified in the literature as giants with spectral type F, G and K. The results were compared with those obtained from 106 evolved stars of spectral type F, G and K, which belong to the spectroscopic binary systems. Accurate measurements on rotation and information about binarity were obtained from De Medeiros s catalog. We have analysed the behavior of the coronal activity in function of diverse stellar parameters. With the purpose to better clarify the profile of the stars evolution, the HR diagram was built for the two samples of stars, the single and the binary ones. The evolved traces added in the diagram were obtained from the Toulouse-Geneve code, Nascimento et al. (2000). The stars were segregated in this diagram not only in range of rotational speed but also in range of X-ray flux. Our analysis shows clearly that the single stars and the binary ones have coronal activity controlled by physical process independent on the rotation. Non magnetic processes seem to be strongly influencing the coronal heating. For the binary stars, we have also studied the behavior of the coronal emission as a function of orbital parameters, such as period and eccentricity, in which it was revealed the existence of a discontinuity in the emission of X-rays around an orbital period of 100 days. The study helped to conclude that circular orbits of the binary stars are presented as a necessary property for the existence of a higher level ofX-rays emission, suggesting that the effect of the gravitational tide has an important role in the coronal activity level. When applied the Kolmogorov-Smirnov test (KS test ) for the Vsini and FX parameters to the samples of single and binary stars, we could evidence very relevant aspects for the understanding of the mechanisms inherent to the coronal activity. For the Vsini parameter, the differences between the single stars and the binary ones for rotation over 6.3 km/s were really remarkable. We believe, therefore, that the existence of gravitational tide is, at least, one of the factors that most contribute for this behavior. About the X-rays flux, the KS test showed that the behavior of the single and the binary stars, regarding the coronal activity, comes from the same origin

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present work we study the processes of heating in the high stellar atmosphere, with base in an analysis of behavior of the cromospheric and coronal emission for a sample of single stars classified as giant in the literature. The evolutionary status of the stars of the sample was determined from HIPPARCOS satellite trigonometric parallax measurements and from the Toulouse Genéve code. In this study we show the form of behavior of the CaII emission flux in spectral lines H and K F(CaII) and the X-ray emission flux in function of the rotation, number of Rossby Ro and depth in mass of the convective envelope. In this analysis we show that while the cromospheric activity is dominated clearly by a physical process of heating associated with the rotation, like a magnetic field produced by dynamo effect, the coronal activity seems to be influenced for a mechanism independent of the rotation. We show also that the effective role of the depth in massa of the convective envelope on the stellar activity has an important effect in the responsible physical process for the behavior of the activity in the atmosphere of the stars.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate the effects of warm-up and stretching, singly or combined, on isokinetic performance and electromyographic activity of the biceps femoris. Materials and methods: Sixty-four volunteers of both sexes, with mean age of 23,1 ± 3,5 years and mean body mass index of 23,5 ± 2,5 Kg/m2 were randomly assigned into 4 groups: control, warm-up (stationary bicycle for 10 minutes), stretching (4 sets of 30 seconds of hamstring muscles static stretching) and warm-up + stretching. All the volunteers were submitted to evaluation pre and post-intervention of the muscle latency time and biceps femoris RMS and the passive torque, peak torque and power of the hamstring muscles. Results: The warm-up + stretching group had reduction of muscle latency time. There was a reduction of RMS during passive torque evaluation in stretching group. The RMS during isometric evaluation was reduced in all experimental groups. The RMS during eccentric evaluation showed reduction in control and warm-up + stretching groups. The passive torque and the eccentric peak torque had no significant differences pre to post-intervention in any group. There was reduction in isometric peak torque in all groups. Conclusion: The warm-up and stretching, when applied in combination can reduce the muscle latency time; stretching protocol promoted neural changes; the protocols used did not alter the muscle viscoelastic properties

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the effect of warm-up on agility (AG) and on vertical jump (VJ) tests in youth soccer players. Sixteen players performed the AG and VJ tests without warm-up (NW) and with warm-up (WW) randomly, within two weeks, at least 48 h interval, during season. The warm-up was performed only a light running during 10 min. The paired t-test identified significant difference (p <0,05) between the NW and WW conditions in the tests of SR and CJ (9,14 +/- 0,28 vs 8,94 +/- 0,30 s e 51,4 +/- 4,2 vs 54,5 +/- 6,4 cm, respectively). The warm-up performed on light intensity running was effective to improve the AG and VJ tests performance in youth soccer players.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Among the non-invasive techniques employed in the prevention of caries highlights the sealing pits and fissures which is a conservative maneuver, in order to obliterate them to protect them from attack acid bacteria. Influenced by the studies of pre-heating composite resin, which has experienced great improvement in some of their physical properties, this study aimed to evaluate in vitro the superficial and internal marginal adaptation of different materials and sealants in pre-heating or not. A total of 40 extracted human third molars (n=10) that had their occlusal surfaces prepared to receive sealant. We tested two types of sealing materials: resin sealant (Fluoroshield) and low-viscosity resin (Permaflo), where 50% of previously received heated material and the other half received sealant material at room temperature. All samples were subjected to thermal cycling and pH, simulating a cariogenic oral environment, and later were analyzed appliance OCT (optical coherence tomography). The images obtained alterations were recorded and analyzed statistically. Change was considered as the emergence of bubbles, gaps and cracks in the sealant. Comparisons of the same material, assessing the fact that it is not sealed or preheated material, as well as comparisons between different materials subjected to the same temperature were carried out. The nonparametric Tukey test was used (p < 0,05). The results showed that there was statistically significant difference between both the materials analyzed, as between the situations in which the sealant material was submitted (preheated or not). On the issue of marginal adaptation and internal surface, seen through Optical coherence tomography, may suggest that there is a difference between the use of one type or another of the sealing material analyzed, with superiority attributed to resin Permaflo compared to sealant Fluroshield, telling is the same for the different techniques used

Relevância:

20.00% 20.00%

Publicador:

Resumo:

JUSTIFICATIVA E OBJETIVOS: em pacientes sob intubação traqueal ou traqueostomia, a umidificação e o aquecimento do gás inalado são necessários para a prevenção de lesões no sistema respiratório, conseqüentes ao contato do gás frio e seco com as vias aéreas. O objetivo da pesquisa foi avaliar o efeito do sistema respiratório circular com absorvedor de dióxido de carbono do aparelho de anestesia Cícero da Dräger, quanto à capacidade de aquecimento e umidificação dos gases inalados, utilizando-se fluxo baixo (1 L.min-1) ou mínimo (0,5 L.min-1) de gases frescos. MÉTODO: O estudo aleatório foi realizado em 24 pacientes, estado físico ASA I, com idades entre 18 e 65 anos, submetidos à anestesia geral, utilizando-se a Estação de Trabalho Cícero da Dräger (Alemanha), para realização de cirurgias abdominais, os quais foram distribuídos aleatoriamente em dois grupos: grupo de Baixo Fluxo (BF), no qual foi administrado 0,5 L.min-1 de oxigênio e 0,5 L.min-1 de óxido nitroso e fluxo mínimo (FM), administrando-se somente oxigênio a 0,5 L.min-1. Os atributos estudados foram temperatura, umidade relativa e absoluta da sala de operação e do gás no sistema inspiratório. RESULTADOS: Os valores da temperatura, umidade relativa e umidade absoluta no sistema inspiratório na saída do aparelho de anestesia e junto ao tubo traqueal não apresentaram diferença significante entre os grupos, mas aumentaram ao longo do tempo nos dois grupos (BF e FM), havendo influência da temperatura da sala de operação sobre a temperatura do gás inalado, nos dois grupos estudados. Níveis de umidade e temperatura próximos dos ideais foram alcançados, nos dois grupos, a partir de 90 minutos. CONCLUSÕES: Não há diferença significante da umidade e temperatura do gás inalado utilizando-se baixo fluxo e fluxo mínimo de gases frescos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to perform voice evaluation in teachers with and without vocal symptoms, identifying etiologic factors of dysphonia, voice symptoms, vocal qualities, and laryngeal lesions. Eighty teachers were divided into two groups: GI (without or sporadic symptoms, 40) and GII (with frequent vocal symptoms, 40). They answered a specific questionnaire, and were subject to a perceptual vocal assessment (maximum phonation time, glottal attack, resonance, coordination of breathing and voicing, pitch, and loudness), GIRBAS scale, and to videolaryngoscopy. Females were predominant in both groups, and the age range was from 36 to 50 years. Elementary teachers predominated, working in classes with 31-40 students. Voice symptoms and alterations in the perceptual vocal analysis and in the GIRBAS scale were more frequent in GII In 46 teachers (GI-16; GII-30), videolaryngoscopy exams were abnormal with the vocal nodules being the most frequent lesions. These results indicate that a teacher's voice is compromised, and requires more attention including control of environmental factors and associated diseases, preventive vocal hygiene, periodic laryngeal examinations, and access to adequate specialist treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mucosal bridges are rare laryngeal lesions probably of genetic origin. They may cause dysphonia of varying degrees, especially when associated with other laryngeal lesions such as vocal sulci and cysts. Reports on mucosal bridges are rare, and the better treatment is inconclusive.Aim. To report the authors' experience in 14 cases of mucosal bridge showing details on endoscopic examinations and treatment.Study Design. Retrospective study.Methods. We reviewed the medical records of 14 patients with a diagnosis of mucosal bridge confirmed by video-laryngostroboscopy and direct laryngoscopy who attended the Outpatient Clinic of Voice Disorders of the Discipline of Otorhinolaryngology, Botucatu Medical School, São Paulo State University, São Paulo. Data collected included information on gender, age, symptoms, time of onset, history of intubation, smoking status, alcohol intake, associated laryngeal lesions, treatment, and GRBAS (grade of hoarseness, roughness, breathiness, asthenia, and stress) scale ratings.Results. of 14 patients, 10 were females and four were males. There was a prevalence of adults (n = 12), with only two of the patients being younger than 13 years (10 and 13 years). Mucosal bridges showed no correlations with smoking, alcohol intake, or gastroesophageal and sinonasal symptoms. Voice abuse was reported in 50% of the cases that consisted of patients who had high-voice demand occupations. In seven cases, mucosal bridges were associated with other laryngeal lesions, particularly vocal cysts and sulci. All patients who underwent surgery and phonotherapy showed improved vocal quality.Conclusions. We documented 14 patients with dysphonia caused by mucosal bridge. Promising results were obtained with surgery.