986 resultados para Aortic regurgitation
Resumo:
AbstractBackground:Predicting mortality in patients undergoing transcatheter aortic valve implantation (TAVI) remains a challenge.Objectives:To evaluate the performance of 5 risk scores for cardiac surgery in predicting the 30-day mortality among patients of the Brazilian Registry of TAVI.Methods:The Brazilian Multicenter Registry prospectively enrolled 418 patients undergoing TAVI in 18 centers between 2008 and 2013. The 30-day mortality risk was calculated using the following surgical scores: the logistic EuroSCORE I (ESI), EuroSCORE II (ESII), Society of Thoracic Surgeons (STS) score, Ambler score (AS) and Guaragna score (GS). The performance of the risk scores was evaluated in terms of their calibration (Hosmer–Lemeshow test) and discrimination [area under the receiver–operating characteristic curve (AUC)].Results:The mean age was 81.5 ± 7.7 years. The CoreValve (Medtronic) was used in 86.1% of the cohort, and the transfemoral approach was used in 96.2%. The observed 30-day mortality was 9.1%. The 30-day mortality predicted by the scores was as follows: ESI, 20.2 ± 13.8%; ESII, 6.5 ± 13.8%; STS score, 14.7 ± 4.4%; AS, 7.0 ± 3.8%; GS, 17.3 ± 10.8%. Using AUC, none of the tested scores could accurately predict the 30-day mortality. AUC for the scores was as follows: 0.58 [95% confidence interval (CI): 0.49 to 0.68, p = 0.09] for ESI; 0.54 (95% CI: 0.44 to 0.64, p = 0.42) for ESII; 0.57 (95% CI: 0.47 to 0.67, p = 0.16) for AS; 0.48 (95% IC: 0.38 to 0.57, p = 0.68) for STS score; and 0.52 (95% CI: 0.42 to 0.62, p = 0.64) for GS. The Hosmer–Lemeshow test indicated acceptable calibration for all scores (p > 0.05).Conclusions:In this real world Brazilian registry, the surgical risk scores were inaccurate in predicting mortality after TAVI. Risk models specifically developed for TAVI are required.
Resumo:
Abstract Background: The use of aortic counterpulsation therapy in advanced heart failure is controversial. Objectives: To evaluate the hemodynamic and metabolic effects of intra-aortic balloon pump (IABP) and its impact on 30-day mortality in patients with heart failure. Methods: Historical prospective, unicentric study to evaluate all patients treated with IABP betwen August/2008 and July/2013, included in an institutional registry named TBRIDGE (The Brazilian Registry of Intra-aortic balloon pump in Decompensated heart failure - Global Evaluation). We analyzed changes in oxygen central venous saturation (ScvO2), arterial lactate, and use of vasoactive drugs at 48 hours after IABP insertion. The 30-day mortality was estimated by the Kaplan-Meier method and diferences in subgroups were evaluated by the Log-rank test. Results: A total of 223 patients (mean age 49 ± 14 years) were included. Mean left ventricle ejection fraction was 24 ± 10%, and 30% of patients had Chagas disease. Compared with pre-IABP insertion, we observed an increase in ScvO2 (50.5% vs. 65.5%, p < 0.001) and use of nitroprusside (33.6% vs. 47.5%, p < 0.001), and a decrease in lactate levels (31.4 vs. 16.7 mg/dL, p < 0.001) and use of vasopressors (36.3% vs. 25.6%, p = 0.003) after IABP insertion. Thirty-day survival was 69%, with lower mortality in Chagas disease patients compared without the disease (p = 0.008). Conclusion: After 48 hours of use, IABP promoted changes in the use of vasoactive drugs, improved tissue perfusion. Chagas etiology was associated with lower 30-day mortality. Aortic counterpulsation therapy is an effective method of circulatory support for patients waiting for heart transplantation.
Resumo:
Abstract Background: Configuration of the abdominal aorta is related to healthy aging and a variety of disorders. Objectives: We aimed to assess heritable and environmental effects on the abdominal aortic diameter. Methods: 114 adult (69 monozygotic, 45 same-sex dizygotic) twin pairs (mean age 43.6 ± 16.3 years) underwent abdominal ultrasound with Esaote MyLab 70X ultrasound machine to visualize the abdominal aorta below the level of the origin of the renal arteries and 1-3 cm above the bifurcation. Results: Age- and sex-adjusted heritability of the abdominal aortic diameter below the level of the origin of the renal arteries was 40% [95% confidence interval (CI), 14 to 67%] and 55% above the aortic bifurcation (95% CI, 45 to 70%). None of the aortic diameters showed common environmental effects, but unshared environmental effects were responsible for 60% and 45% of the traits, respectively. Conclusions: Our analysis documents the moderate heritability and its segment-specific difference of the abdominal aortic diameter. The moderate part of variance was explained by unshared environmental components, emphasizing the importance of lifestyle factors in primary prevention. Further studies in this field may guide future gene-mapping efforts and investigate specific lifestyle factors to prevent abdominal aortic dilatation and its complications.
Resumo:
Abstract A literature overview of angiographic studies has shown that the prevalence of significant coronary disease in patients with aortic stenosis (AS) varies from 20 to 60%. Early necropsy studies suggested that patients with AS had a lower than expected incidence of coronary artery disease (CAD), originating the concept of a protective effect of AS on the coronary arteries. The myth of AS protection against CAD would be better explained as endothelium-myocardial interaction (crosstalk) protection triggered by left ventricular overload. Therefore, the cGMP/NO pathway induced by the AS overload pressure would explain the low incidence of CAD, which is compatible with the amazing natural long-term evolution of this cardiac valve disease.
Resumo:
We reviewed our surgery registry, to identify predictive risk factors for operative results, and to analyse the long-term survival outcome in octogenarians operated for primary isolated aortic valve replacement (AVR). A total of 124 consecutive octogenarians underwent open AVR from January 1990 to December 2005. Combined procedures and redo surgery were excluded. Selected variables were studied as risk factors for hospital mortality and early neurological events. A follow-up (FU; mean FU time: 77 months) was obtained (90% complete), and Kaplan-Meier plots were used to determine survival rates. The mean age was 82+/-2.2 (range: 80-90 years; 63% females). Of the group, four patients (3%) required urgent procedures, 10 (8%) had a previous myocardial infarction, six (5%) had a previous coronary angioplasty and stenting, 13 patients (10%) suffered from angina and 59 (48%) were in the New York Heart Association (NYHA) class III-IV. We identified 114 (92%) degenerative stenosis, six (5%) post-rheumatic stenosis and four (3%) active endocarditis. The predicted mortality calculated by logistic European System for Cardiac Operative Risk Evaluation (EuroSCORE) was 12.6+/-5.7%, and the observed hospital mortality was 5.6%. Causes of death included severe cardiac failure (four patients), multi-organ failure (two) and sepsis (one). Complications were transitory neurological events in three patients (2%), short-term haemodialysis in three (2%), atrial fibrillation in 60 (48%) and six patients were re-operated for bleeding. Atrio-ventricular block, myocardial infarction or permanent stroke was not detected. The age at surgery and the postoperative renal failure were predictors for hospital mortality (p value <0.05), whereas we did not find predictors for neurological events. The mean FU time was 77 months (6.5 years) and the mean age of surviving patients was 87+/-4 years (81-95 years). The actuarial survival estimates at 5 and 10 years were 88% and 50%, respectively. Our experience shows good short-term results after primary isolated standard AVR in patients more than 80 years of age. The FU suggests that aortic valve surgery in octogenarians guarantees satisfactory long-term survival rates and a good quality of life, free from cardiac re-operations. In the era of catheter-based aortic valve implantation, open-heart surgery for AVR remains the standard of care for healthy octogenarians.