888 resultados para Anterior spinal fusion


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Trauma to the spinal cord creates an initial physical injury damaging neurons, glia, and blood vessels, which then induces a prolonged inflammatory response, leading to secondary degeneration of spinal cord tissue, and further loss of neurons and glia surrounding the initial site of injury. Angiogenesis is a critical step in tissue repair, but in the injured spinal cord angiogenesis fails; blood vessels formed initially later regress. Stabilizing the angiogenic response is therefore a potential target to improve recovery after spinal cord injury (SCI). Vascular endothelial growth factor (VEGF) can initiate angiogenesis, but cannot sustain blood vessel maturation. Platelet-derived growth factor (PDGF) can promote blood vessel stability and maturation. We therefore investigated a combined application of VEGF and PDGF as treatment for traumatic spinal cord injury, with the aim to reduce secondary degeneration by promotion of angiogenesis. Immediately after hemisection of the spinal cord in the rat we delivered VEGF and PDGF and to the injury site. One and 3 months later the size of the lesion was significantly smaller in the treated group compared to controls, and there was significantly reduced gliosis surrounding the lesion. There was no significant effect of the treatment on blood vessel density, although there was a significant reduction in the numbers of macrophages/microglia surrounding the lesion, and a shift in the distribution of morphological and immunological phenotypes of these inflammatory cells. VEGF and PDGF delivered singly exacerbated secondary degeneration, increasing the size of the lesion cavity. These results demonstrate a novel therapeutic intervention for SCI, and reveal an unanticipated synergy for these growth factors whereby they modulated inflammatory processes and created a microenvironment conducive to axon preservation/sprouting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Use of patient-specific computer models as a pre-operative planning tool permits predictions of the likely deformity correction and allows a more detailed investigation of the biomechanical influence of different surgical procedures on the scoliotic spinal anatomy. In this paper, patient-specific computer models are used of adolescent idiopathic scoliosis patients who underwent a single rod anterior procedure at the Mater Children’s Hospital in Brisbane, to predict deformity correction and to investigate the change in biomechanics of the scoliotic spine due to surgical compressive forces applied during implant placement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The progression of spinal deformity is traditionally monitored on hard copy radiographs using the Cobb method with a protractor and pencil. The rotation of the spine and ribcage (rib hump) in scoliosis is measured with a hand-held inclinometer/Scoliometer. The iPhone and other smart phones, can accurately sense inclination, and can therefore be used to measure Cobb angles and rib hump angulation. The purpose of this study was to quantify the performance of the iPhone compared to the standard protractor (Cobb angles) and the Scoliometer (rib hump).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Corals inhabit high energy environments where frequent disturbances result in physical damage to coralla, including fragmentation, as well as generating and mobilizing large sediment clasts. The branching growth form common in the Acropora genus makes it particularly susceptible to such disturbances and therefore useful for study of the fate of large sediment clasts. Living Acropora samples with natural, extraneous, broken coral branches incorporated on their living surface and dead Acropora skeletons containing embedded clasts of isolated branch sections of Acropora were observed and/or collected from the reef flat of Heron Reef, southern Great Barrier Reef and Bargara, Australia respectively. Here we report three different outcomes when pebble-sized coral branches became lodged on living coral colonies during sedimentation events in natural settings in Acropora: 1) Where live coral branches produced during a disturbance event come to rest on probable genetic clone-mate colonies they become rapidly stabilised leading to complete soft tissue and skeletal fusion; 2) Where the branch and underlying colony are not clone-mates, but may still be the same or similar species, the branches still may be stabilised rapidly by soft tissue, but then one species will overgrow the other; and 3) Where branches represent dead skeletal debris, they are treated like any foreign clast and are surrounded by clypeotheca and incorporated into the corallum by overgrowth. The retention of branch fragments on colonies in high energy reef flat settings may suggest an active role of coral polyps to recognise and fuse with each other. Also, in all cases the healing of disturbed tissue and subsequent skeletal growth is an adaptation important for protecting colonies from invasion by parasites and other benthos following disturbance events and may also serve to increase corallum strength. Knowledge of such adaptations is important in studies of coral behaviour during periods of environmental stress.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Development of vaccine strategies against human papillomavirus (HPV), which causes cervical cancer, is a priority. We investigated the use of virus-like particles (VLPs) of the most prevalent type, HPV-16, as carriers of foreign proteins. Green fluorescent protein (GFP) was fused to the N or C terminus of both L1 and L2, with L2 chimeras being co-expressed with native L1. Purified chimaeric VLPs were comparable in size (∼55 nm) to native HPV VLPs. Conformation-specific monoclonal antibodies (Mabs) bound to the VLPs, thereby indicating that they possibly retain their antigenicity. In addition, all of the VLPs encapsidated DNA in the range of 6-8 kb. © 2007 Springer-Verlag.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A significant issue encountered when fusing data received from multiple sensors is the accuracy of the timestamp associated with each piece of data. This is particularly important in applications such as Simultaneous Localisation and Mapping (SLAM) where vehicle velocity forms an important part of the mapping algorithms; on fastmoving vehicles, even millisecond inconsistencies in data timestamping can produce errors which need to be compensated for. The timestamping problem is compounded in a robot swarm environment due to the use of non-deterministic readily-available hardware (such as 802.11-based wireless) and inaccurate clock synchronisation protocols (such as Network Time Protocol (NTP)). As a result, the synchronisation of the clocks between robots can be out by tens-to-hundreds of milliseconds making correlation of data difficult and preventing the possibility of the units performing synchronised actions such as triggering cameras or intricate swarm manoeuvres. In this thesis, a complete data fusion unit is designed, implemented and tested. The unit, named BabelFuse, is able to accept sensor data from a number of low-speed communication buses (such as RS232, RS485 and CAN Bus) and also timestamp events that occur on General Purpose Input/Output (GPIO) pins referencing a submillisecondaccurate wirelessly-distributed "global" clock signal. In addition to its timestamping capabilities, it can also be used to trigger an attached camera at a predefined start time and frame rate. This functionality enables the creation of a wirelessly-synchronised distributed image acquisition system over a large geographic area; a real world application for this functionality is the creation of a platform to facilitate wirelessly-distributed 3D stereoscopic vision. A ‘best-practice’ design methodology is adopted within the project to ensure the final system operates according to its requirements. Initially, requirements are generated from which a high-level architecture is distilled. This architecture is then converted into a hardware specification and low-level design, which is then manufactured. The manufactured hardware is then verified to ensure it operates as designed and firmware and Linux Operating System (OS) drivers are written to provide the features and connectivity required of the system. Finally, integration testing is performed to ensure the unit functions as per its requirements. The BabelFuse System comprises of a single Grand Master unit which is responsible for maintaining the absolute value of the "global" clock. Slave nodes then determine their local clock o.set from that of the Grand Master via synchronisation events which occur multiple times per-second. The mechanism used for synchronising the clocks between the boards wirelessly makes use of specific hardware and a firmware protocol based on elements of the IEEE-1588 Precision Time Protocol (PTP). With the key requirement of the system being submillisecond-accurate clock synchronisation (as a basis for timestamping and camera triggering), automated testing is carried out to monitor the o.sets between each Slave and the Grand Master over time. A common strobe pulse is also sent to each unit for timestamping; the correlation between the timestamps of the di.erent units is used to validate the clock o.set results. Analysis of the automated test results show that the BabelFuse units are almost threemagnitudes more accurate than their requirement; clocks of the Slave and Grand Master units do not di.er by more than three microseconds over a running time of six hours and the mean clock o.set of Slaves to the Grand Master is less-than one microsecond. The common strobe pulse used to verify the clock o.set data yields a positive result with a maximum variation between units of less-than two microseconds and a mean value of less-than one microsecond. The camera triggering functionality is verified by connecting the trigger pulse output of each board to a four-channel digital oscilloscope and setting each unit to output a 100Hz periodic pulse with a common start time. The resulting waveform shows a maximum variation between the rising-edges of the pulses of approximately 39¥ìs, well below its target of 1ms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Endoscopic scoliosis correction plays an important part in the surgical options available for treating adolescent idiopathic scoliosis. However, there is a paucity of literature examining optimum methods of analgesia following this type of surgery. The role of intrapleural analgesia is examined and described. In this study, local anaesthetic administration via an intrapleural catheter was found to be a safe and effective method of analgesia following endoscopic scoliosis correction. Post-operative pain following anterior scoliosis correction can be reduced to ‘mild’ levels by combined analgesia regimes. Surgeons may wish to expand its use into open or minimally invasive anterior scoliosis correction or anterior releases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Adolescent idiopathic scoliosis is a complex three dimensional deformity affecting 2-3% of the general population. Resulting spine deformities include progressive coronal curvature, hypokyphosis, or frank lordosis in the thoracic spine and vertebral rotation in the axial plane with posterior elements turned into the curve concavity. The potential for curve progression is heightened during the adolescent growth spurt. Success of scoliosis deformity correction depends on solid bony fusion between adjacent vertebrae after the intervertebral discs have been surgically cleared and the disc spaces filled with graft material. Problems with bone graft harvest site morbidity as well as limited bone availability have led to the search for bone graft substitutes. Recently, a bioactive and resorbable scaffold fabricated from medical grade polycaprolactone (PCL) has been developed for bone regeneration at load bearing sites. Combined with recombinant human bone morphogenic protein–2 (rhBMP-2), this has been shown to be successful in acting as a bone graft substitute in acting as a bone graft substitute in a porcine lumbar interbody fusion model when compared to autologous bone graft. This in vivo sheep study intends to evaluate the suitability of a custom designed medical grade PCL scaffold in combination with rhBMP-2 as a bone graft substitute in the setting of mini–thoracotomy surgery as a platform for ongoing research to benefit patients with adolescent idiopathic scoliosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Current state of the art robot mapping and navigation systems produce impressive performance under a narrow range of robot platform, sensor and environmental conditions, in contrast to animals such as rats that produce “good enough” maps that enable them to function under an incredible range of situations. In this paper we present a rat-inspired featureless sensor-fusion system that assesses the usefulness of multiple sensor modalities based on their utility and coherence for place recognition during a navigation task, without knowledge as to the type of sensor. We demonstrate the system on a Pioneer robot in indoor and outdoor environments with abrupt lighting changes. Through dynamic weighting of the sensors, the system is able to perform correct place recognition and mapping where the static sensor weighting approach fails.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Adolescent idiopathic scoliosis (AIS) is a deformity of the spine, which may 34 require surgical correction by attaching a rod to the patient’s spine using screws 35 implanted in the vertebral bodies. Surgeons achieve an intra-operative reduction in the 36 deformity by applying compressive forces across the intervertebral disc spaces while 37 they secure the rod to the vertebra. We were interested to understand how the 38 deformity correction is influenced by increasing magnitudes of surgical corrective forces 39 and what tissue level stresses are predicted at the vertebral endplates due to the 40 surgical correction. 41 Methods: Patient-specific finite element models of the osseoligamentous spine and 42 ribcage of eight AIS patients who underwent single rod anterior scoliosis surgery were 43 created using pre-operative computed tomography (CT) scans. The surgically altered 44 spine, including titanium rod and vertebral screws, was simulated. The models were 45 analysed using data for intra-operatively measured compressive forces – three load 46 profiles representing the mean and upper and lower standard deviation of this data 47 were analysed. Data for the clinically observed deformity correction (Cobb angle) were 48 compared with the model-predicted correction and the model results investigated to 49 better understand the influence of increased compressive forces on the biomechanics of 50 the instrumented joints. 51 Results: The predicted corrected Cobb angle for seven of the eight FE models were 52 within the 5° clinical Cobb measurement variability for at least one of the force profiles. 53 The largest portion of overall correction was predicted at or near the apical 54 intervertebral disc for all load profiles. Model predictions for four of the eight patients 55 showed endplate-to-endplate contact was occurring on adjacent endplates of one or 56 more intervertebral disc spaces in the instrumented curve following the surgical loading 57 steps. 58 Conclusion: This study demonstrated there is a direct relationship between intra-59 operative joint compressive forces and the degree of deformity correction achieved. The 60 majority of the deformity correction will occur at or in adjacent spinal levels to the apex 61 of the deformity. This study highlighted the importance of the intervertebral disc space 62 anatomy in governing the coronal plane deformity correction and the limit of this 63 correction will be when bone-to-bone contact of the opposing vertebral endplates 64 occurs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mobile devices and smartphones have become a significant communication channel for everyday life. The sensing capabilities of mobile devices are expanding rapidly, and sensors embedded in these devices are cheaper and more powerful than before. It is evident that mobile devices have become the most suitable candidates to sense contextual information without needing extra tools. However, current research shows only a limited number of sensors are being explored and investigated. As a result, it still needs to be clarified what forms of contextual information extracted from mo- bile sensors are useful. Therefore, this research investigates the context sensing using current mobile sensors, the study follows experimental methods and sensor data is evaluated and synthesised, in order to deduce the value of various sensors and combinations of sensor for the use in context-aware mobile applications. This study aims to develop a context fusion framework that will enhance the context-awareness on mobile applications, as well as exploring innovative techniques for context sensing on smartphone devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The role of inflammatory response after spinal cord injury remains unclear. This thesis was a step forward in studying how promoting the inflammation, by delivery pro-inflammatory growth factors, affects the outcomes of spinal cord injury. A significant functional improvement was observed after treatment and these results suggest an interesting avenue for future clinical treatments and may provide a platform to improve the efficacy of other treatments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, a treatment plan for a spinal lesion, with all beams transmitted though a titanium vertebral reconstruction implant, was used to investigate the potential effect of a high-density implant on a three-dimensional dose distribution for a radiotherapy treatment. The BEAMnrc/DOSXYZnrc and MCDTK Monte Carlo codes were used to simulate the treatment using both a simplified, recltilinear model and a detailed model incorporating the full complexity of the patient anatomy and treatment plan. The resulting Monte Carlo dose distributions showed that the commercial treatment planning system failed to accurately predict both the depletion of dose downstream of the implant and the increase in scattered dose adjacent to the implant. Overall, the dosimetric effect of the implant was underestimated by the commercial treatment planning system and overestimated by the simplified Monte Carlo model. The value of performing detailed Monte Carlo calculations, using the full patient and treatment geometry, was demonstrated.