967 resultados para Alternating direct method
Resumo:
Erosion potential and the effects of tillage can be evaluated from quantitative descriptions of soil surface roughness. The present study therefore aimed to fill the need for a reliable, low-cost and convenient method to measure that parameter. Based on the interpretation of micro-topographic shadows, this new procedure is primarily designed for use in the field after tillage. The principle underlying shadow analysis is the direct relationship between soil surface roughness and the shadows cast by soil structures under fixed sunlight conditions. The results obtained with this method were compared to the statistical indexes used to interpret field readings recorded by a pin meter. The tests were conducted on 4-m2 sandy loam and sandy clay loam plots divided into 1-m2 subplots tilled with three different tools: chisel, tiller and roller. The highly significant correlation between the statistical indexes and shadow analysis results obtained in the laboratory as well as in the field for all the soil?tool combinations proved that both variability (CV) and dispersion (SD) are accommodated by the new method. This procedure simplifies the interpretation of soil surface roughness and shortens the time involved in field operations by a factor ranging from 12 to 20.
Resumo:
We have developed a technique for isolating DNA markers tightly linked to a target region that is based on RLGS, named RLGS spot-bombing (RLGS-SB). RLGS-SB allows us to scan the genome of higher organisms quickly and efficiently to identify loci that are linked to either a target region or gene of interest. The method was initially tested by analyzing a C57BL/6-GusS mouse congenic strain. We identified 33 variant markers out of 10,565 total loci in a 4.2-centimorgan (cM) interval surrounding the Gus locus in 4 days of laboratory work. The validity of RLGS-SB to find DNA markers linked to a target locus was also tested on pooled DNA from segregating backcross progeny by analyzing the spot intensity of already mapped RLGS loci. Finally, we used RLGS-SB to identify DNA markers closely linked to the mouse reeler (rl) locus on chromosome 5 by phenotypic pooling. A total of 31 RLGS loci were identified and mapped to the target region after screening 8856 loci. These 31 loci were mapped within 11.7 cM surrounding rl. The average density of RLGS loci located in the rl region was 0.38 cM. Three loci were closely linked to rl showing a recombination frequency of 0/340, which is < 1 cM from rl. Thus, RLGS-SB provides an efficient and rapid method for the detection and isolation of polymorphic DNA markers linked to a trait or gene of interest.
Resumo:
Mode of access: Internet.
Resumo:
"A compilation of many of the most valuable instruction books of the American school of correspondence."--Forword.
Resumo:
"18 October 1982."
Resumo:
Mode of access: Internet.
Resumo:
Includes index.
Resumo:
Includes index.
Resumo:
Mode of access: Internet.
Resumo:
In this paper, we assess the relative performance of the direct valuation method and industry multiplier models using 41 435 firm-quarter Value Line observations over an 11 year (1990–2000) period. Results from both pricingerror and return-prediction analyses indicate that direct valuation yields lower percentage pricing errors and greater return prediction ability than the forward price to aggregated forecasted earnings multiplier model. However, a simple hybrid combination of these two methods leads to more accurate intrinsic value estimates, compared to either method used in isolation. It would appear that fundamental analysis could benefit from using one approach as a check on the other.
Resumo:
We propose two algorithms involving the relaxation of either the given Dirichlet data (boundary displacements) or the prescribed Neumann data (boundary tractions) on the over-specified boundary in the case of the alternating iterative algorithm of Kozlov et al. [16] applied to Cauchy problems in linear elasticity. A convergence proof of these relaxation methods is given, along with a stopping criterion. The numerical results obtained using these procedures, in conjunction with the boundary element method (BEM), show the numerical stability, convergence, consistency and computational efficiency of the proposed method.
Resumo:
An alternating procedure for solving a Cauchy problem for the stationary Stokes system is presented. A convergence proof of this procedure and numerical results are included.
Resumo:
The aim of this study was to develop a multiplex loop-mediated isothermal amplification (LAMP) method capable of detecting Escherichia coli generally and verocytotoxigenic E. coli (VTEC) specifically in beef and bovine faeces. The LAMP assay developed was highly specific (100%) and able to distinguish between E. coli and VTEC based on the amplification of the phoA, and stx1 and/or stx2 genes, respectively. In the absence of an enrichment step, the limit of detection 50% (LOD50) of the LAMP assay was determined to be 2.83, 3.17 and 2.83-3.17 log CFU/g for E. coli with phoA, stx1 and stx2 genes, respectively, when artificially inoculated minced beef and bovine faeces were tested. The LAMP calibration curves generated with pure cultures, and spiked beef and faeces, suggested that the assay had good quantification capability. Validation of the assay, performed using retail beef and bovine faeces samples, demonstrated good correlation between counts obtained by the LAMP assay and by a conventional culture method, but suggested the possibility of false negative LAMP results for 12.5-14.7% of samples tested. The multiplex LAMP assay developed potentially represents a rapid alternative to culture for monitoring E.coli levels in beef or faeces and it would provide additional information on the presence of VTEC. However, some further optimisation is needed to improve detection sensitivity.
Resumo:
X-ray fluorescence (XRF) is a fast, low-cost, nondestructive, and truly multielement analytical technique. The objectives of this study are to quantify the amount of Na(+) and K(+) in samples of table salt (refined, marine, and light) and to compare three different methodologies of quantification using XRF. A fundamental parameter method revealed difficulties in quantifying accurately lighter elements (Z < 22). A univariate methodology based on peak area calibration is an attractive alternative, even though additional steps of data manipulation might consume some time. Quantifications were performed with good correlations for both Na (r = 0.974) and K (r = 0.992). A partial least-squares (PLS) regression method with five latent variables was very fast. Na(+) quantifications provided calibration errors lower than 16% and a correlation of 0.995. Of great concern was the observation of high Na(+) levels in low-sodium salts. The presented application may be performed in a fast and multielement fashion, in accordance with Green Chemistry specifications.